Display
Touch to display
Run Time,
Outdoor & Slab
Status Field
Operation Field
Touch to turn system
off while away
Temperature
Touch to quickly enter
the View menu
Touch to go to the next setting
Touch to
Melt or Stop
Touch to adjust settings
Operation Field
MELT System is melting snow or ice.
IDLE System is idling.
Status Field
WWSD
CWCO Cold Weather Cut Out. Too cold to melt.
TIMED
WARM Slab is warming up to the melting temperature.
AWAY
Warm Weather Shut Down. The slab is naturally
warm enough to melt snow or ice.
Timed melting operation. System operates until
time has elapsed.
Away scene. No melting until the away scene is
exited.
Home Button
Return to the Home Screen
Press and hold for 3
seconds to access the
Home
Button
ENTER
programming menus.
STRM System is in storm operation.
OFF System is off.
PEND
WAIT
SENSOR
TRACK
Pending. The system has detected water but it is too
cold to operate or the schedule is in Idle or Off.
Zone priority in effect. Zone must wait until higher
priority zone finishes melting.
Tandem 090 sensor.
This zone tracks the melting operation of zone 1.
Symbols
HEAT ON
Heat is turned on.
tekmarNet
Communication is present.
A Watts Water Technologies Company
®
1 of 4
WARNING SYMBOL
Indicates an error is present.
ARROWS
Adjust the displayed setting.
© 2013 654_U - 05/13

Snow Melting Operation
--------------------------------
-------------------------
---------------------------------------------------------------
----------------------------------------
------------------------------------
Snow melting operation can be started manually or automatically depending on which sensors are installed. Automatic
start and stop operation requires a Snow / Ice Sensor 090,
or 094. Automatic start with a timed stop requires a Snow
Sensor 095.
Manual Operation
Touch the Melt key on the control display. The control uses a
timer to operate the snow melting system and shuts off when
the timer has expired.
Press
Melt
Automatic Start and Stop
The system automatically starts as soon as snow or ice is
detected and stops when the slab is dry. A Snow / Ice Sensor 090
or 094 is required for automatic start and stop operation.
--------------------------------
-------------------------
Automatic Start and Timed Stop
The system automatically starts as soon as snow or ice is
detected and stops when the Manual Melt Run Time counter
has elasped. The Manual Melt Run Time setting is adjustable
in the Set Temp menu. A Snow Sensor 095 is required for
automatic start and timed operation.
Snow
Sensor
095
Tracked Start and Stop
The snow melting system can have multiple zones. Zones
without a snow / ice sensor or snow sensor can repeat the
run time of zone 1.
----------------------------------------
------------------
Track Melt Start and Stop
Snow / Ice
Sensor
090 or 094
EconoMelt
When a Snow / Ice Sensor is installed, the control has the
option to EconoMelt. This allows the snow to be mechanically
removed using a plow or shovel and then manually starting
the snow melting system to melt the remaining last thin layer
of snow or ice. The system operates until the sensor is dry.
---------------------------------------------------------------
Zone 1
Snow / Ice
Sensor
Records
Run Time
Scheduled Start and Stop
The snow melting system can start and stop based upon a
programmable schedule. While the schedule is in Event 1
(wake) or 3 (occupied), the control is in melt operation. When
the schedule is in Event 2 (unoccupied) or 4 (sleep) the control
is in idle or off operation.
Zone 2 Zone 3
Slab
Sensor
Repeats
Zone 1 Run
Time + Add
Melt Time
------------------------
Slab
Sensor
Repeats
Zone 1 Run
Time + Add
Melt Time
A Watts Water Technologies Company
Idle Operation
Idle operation pre-heats the slab whenever the slab is below
freezing. This allows the slab to quickly warm up to the
melting temperature in case snow or ice is detected. Idling
requires a large amount of energy and is recommened for
commercial or institutional installations where safety concerns
are paramount.
2 of 4
------------------------------------
© 2013 654_U - 05/13

Storm Operation
---------------------------
If a User Switch has been installed, press the ‘Storm’ button
to pre-heat the slab in the event of a snow fall warning. If no
snow is detected or the system is not manually started during
the pre-set time, the system will shut off. If snow is detected,
the slab temperature will be increased to provide snow melting.
A Snow / Ice Sensor 090 or 094 or a Slab Sensor 072 or 073
is required for Storm operation.
Away Key
This control includes an Away Key to quickly disable the
snow melting system, and when connected to a tekmarNet®
system, can also turn down the heating temperature on all
thermostats and suspend heating the domestic hot water
tank to maximize energy savings. To turn on the Away Key,
go to the Scene menu.
To activate the Away scene, touch “Going Away” on the
screen.
Select PERM (permanent) or a number of days using the
•
or arrow. Range is 1 to 180 days.
Press the home button to accept the setting or leave the
•
screen untouched for several seconds.
“Scene Away” is displayed on the home screen until the
•
number of days expires.
Touch “Cancel Away” to cancel at any time.
•
Press
Storm
Storm
Melt
Away
Programming Menus
Press and hold the Home button for 3 seconds to enter the programming menus. The control returns to the last programming
menu previously used.
Press and
hold for 3
seconds to
access the
programming
menus.
Select a Programming Menu
Touch “NEXT” to advance (clockwise in
•
illustration) to the next menu.
Touch “BACK” to go backwards (counterclock-
•
wise in illustration) through the menus.
•
Touch “ENTER” to enter a menu.
Setting Items
•
Touch or arrow to adjust the setting if
required.
Touch “NEXT ITEM” to advance to the next item
•
within the menu.
•
Touch “BACK ITEM” to go backwards to the previous item within the menu.
•
To return to the parent menu after changing a
setting, press and release the Home button.
•
To return to the Home screen, press and release
the Home button twice or wait 30 seconds to automatically return to the Home screen.
---------------------------
-----------
A Watts Water Technologies Company
3 of 4
© 2013 654_U - 05/13

Programming Menus
---------------------------------------
-----------------------------------
---------------------------------------
-----------------------------------
-------------------------------------
--------------------------------------
------------------------------------
------------------------------------
-------------------------------------
View Menu
Displays current operating temperatures and status information of the system.
Snow Zone - The snow melt zone number on the tekmar-
®
system.
Net
Outdoor - Current outdoor air temperature as measured by
the outdoor sensor.
Slab - Current slab temperature as measured by the control.
Water Sensor - Current status of the water detection sensor.
Heat Relay - Current status of the heat relay.
System Pump Relay - Current status of the system pump relay.
Alert Relay - Current status of the alert relay.
Set Temp Menu
The Set Temp menu items select the operating temperatures
of the snow melt system.
Melting - Select the desired surface temperature of the snow
melt surface when melting. The factory default is 36°F or
2.0°C.
Manual Melt Run Time - Select the amount of running time
when manually starting the system.
Time Menu
The control has a built-in time clock to allow the control to
operate on a schedule. A battery-less backup allows the control
to keep time for up to 4 hours without power. The time clock
supports automatic adjustment for Daylight Saving Time (DST)
once the day, month and year are entered. Use the Time menu
to set the correct time, day, month and year.
---------------------------------------
-----------------------------------
---------------------------------------
Display Menu
Units - Select temperature units in degrees Fahrenheit or
Celsius.
Backlight Options - Select how the display backlight
operates.
•
ON = Always on.
•
ON MELT =
vides a visual indicator to indicate that the snow melting system
is currently melting.
OFF = Always off.
•
Scene Menu
Scenes - Scenes provide system-wide overrides to save
energy. Select whether scenes are not used (none) or if the
away scene is available.
Away Key - If scenes are available, select if the away key is
available or not.
Monitor Menu
Heat Hours - Records the number of running hours since the
item was last reset. Touch the number and then the ENTER
key to reset to zero.
System Pump Hours - Records the system pump running
hours since the item was last reset. Touch the number and
then the ENTER key to reset to zero.
Toolbox Menu
Access - Change the access level on the thermostat.
Software Version and Type Number - Display the software
“SW” and the “TYPE” number.
-------------------------------------
On when melting, off when not melting. This pro-
--------------------------------------
------------------------------------
------------------------------------
Schedule Menu
This control can operate on a programmable schedule. During
Event 1 or 3 the system is in Melt operation. During Event 2
or 4 the system is in Idle or Off operation.
Options include:
Turning off the schedule (OFF)
•
•
Operate a schedule that applies only to the snow melt system
operated by this control (ZONE)
•
The ability to operate one of the four system-wide schedules
as a master (Schedule Master 1 through 4*)
•
Join one of the four system-wide schedules as a member
(Schedule Member 1 though 4*)
*Requires the control to be connected to a tekmarNet® system.
Once the type of schedule has been selected, the control can
support schedules that have either 2 or 4 events per day.
-----------------------------------
Screen Clean
Entering the Screen Clean menu provides 30 seconds to
clean the thermostat and display with a moist cloth. Do not
use solvents to clean the thermostat.
-------------------------------------
More Information
This User Brochure contains standard information on how to make adjustments to an installed product. More detailed information
can be found in this product’s Installation and Operation Manual (654_D) at www.tekmarControls.com
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more
information: www.watts.com/prop65
tekmar Control Systems Ltd., A Watts Water Technologies Company.
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com
Product design, software & literature are Copyright ©2013 by tekmar
Control Systems Ltd.,
A Watts Water Technologies Company
4 of 4
Head Offi ce: 5100 Silver Star Road,
All specifications are subject to change without notice.
Printed in Canada. 654_U - 05/13.