Quick Setup Guide
Snow Melting Control 654
1.
Location
Exterior
Wall
2. Remove Mounting Base
Behind
Door
Interior
Wall
5 feet
1.5 m
Snow Melting
654_Q
02/14
Replaces: 01/14
3. Install Mounting Base
Base
3 1/4”
(83 mm)
4. Switch Settings
LOCK ACCESS LEVEL
The control is locally locked and the access level cannot be changed. Set to Lock
when installation has been completed.
UNLOCK ACCESS LEVEL
Unused
The control is unlocked and the access level may be changed. Go to the Toolbox
menu to change the access level. Set to Unlock during the installation process.
Back of
Control
1058-01
Switch
Settings
Lock
ON
1
Unlock
2
Stud
Gang
Box
Base
or
Stud
Wall
A Watts Water Technologies Company
1
© 2014 654_Q - 02/14
5. Wiring
Transformer 009
L
N
TT–+
Modulating
Boiler
Relay 003
3
4
5
6
Optional
Snow / Ice Sensor
090 or 094
Snow
Sensor 095
Snow
Or And/Or
Sensor
095
Slab Sensor
072 or 073
tN4
Communication
R
C
2
1
8
7
C tN4
Relay 003
3
4
5
6
Brn
Slab
No Power
Brn
Mod
2
1
8
7
tN4Aux Ht R C
Slab
+
Out/
BlkYel Blu Red Sup
Com–
Bret
Supply
Sensor
082
BlkYel Blu Red
Com
Outdoor
Sensor
070
Brn
Slab
BlkYel Blu Red
Com
System
Pump
LNG
115 V (ac)
6. Install the Control
Base
Front
7. User Interface
Status Field
Operation
Field
Touch to turn system
off while away
Touch to
Melt or Stop
Touch to
adjust settings
Home
Button
ENTER
Touch to display
Run Time,
Outdoor & Slab
Temperature
Touch to quickly enter
the View menu
Touch to go to the
next setting
Home Button
Return to the
Home Screen
Press and hold for 3
seconds to access the
programming menus.
A Watts Water Technologies Company
2
© 2014 654_Q - 02/14
8. Critical Settings
The System Menu provides settings on how to configure and operate the mechanical equipment.
Item Field Description
APPLICATION MODE
Select the control application mode.
PWM = Hydronic Pulse Width Modulation.
BOIL = Hydronic boiler heats snow melting
system.
MIX = Hydronic mixing valve or injection
pump heats snow melting system.
ELEC = Electric snow melt.
090 = Tandem Snow/ Ice Detection
Default = PWM
SNOW / ICE SENSOR
Select if a Snow / Ice Sensor 090 or 094, or
Snow Sensor 095 is installed.
Default = 090
SLAB SENSOR
Select if a Slab Sensor 072 or 073 is installed
to measure the slab temperature.
Default = ON
SLAB PROTECTION
Select if the slab should be protected from
large temperature differentials to avoid
cracking the concrete due to high tensile
stress.
Default = ON
Item Field Description
ECONOMELT
EconoMelt allows the user to mechancially
remove snow then manually start the system
to melt the thin snow layer or ice.
Default = OFF
tekmarNet® SYSTEM PUMP
Select if the system pump located on the
tekmarNet® System Control should operate
when the snow melt zone is heating.
Conditions: Application Mode is set to
PWM, Boil or Mix and Boiler Type is set
to CTRL (tN4 control).
Default = ON
AUXILIARY RELAY
Select if the auxiliary relay should function
as system pump or as an alert.
Default = SYS
MAXIMUM MELT TIME
Select to limit the amount of melting run
time.
Default = 3.0 days
OUTDOOR/BOILER RETURN SENSOR
Select if the Out/Bret wiring terminal is
connected to an outdoor sensor or a boiler
return sensor.
Default = OUT
tekmar Control Systems Ltd., A Watts Water Technologies Company.
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com
Product design, software and literature are Copyright ©2014 by
tekmar Control Systems Ltd.,
A Watts Water Technologies Company
Head Offi ce: 5100 Silver Star Road,
3
All specifications are subject to change without notice.
Printed in Canada. 654_Q - 02/14.