Steele Products SP-GG200D User Manual

WARNING! To Reduce The Risk Of Injury, User Must Read And Understand Instruction Manual.
2000W Generator
Topic Page
Battery 15
Operation 17
Installation 23
3ytnarraWdetimiL
5senilediuGytefaS
6snoituacerPlareneG
12ecnanetniaMdnagninaelC,noitcepsnI
Specifications 25
gnitsiLstraPlareneG
WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/ OR VOIDING OF YOUR WARRANTY. DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.
STEELE®
WILL NOT BE LIABLE FOR ANY
62
2
Limited Warranty
Owner s Manual
STEELE®
application (personal, residential or household usage) that all products covered under this warranty are free from defects in material and workmanship for one year from the date of purchase. All products covered by this limited warranty which are used in commercial applications (i.e. income producing) are warranted to be free of defects in material and workmanship for 90 days from the date of original purchase. Products covered under this warranty include air compressors, air tools, service parts, pressure washers and generators.
STEELE®
components which have failed within the warranty period. Service will be scheduled according to the normal work flow and business hours at the service center location, and the availability of replacement parts. All decisions of
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (initial User):
To process a warranty claim on this product, DO NOT return item to the retailer. The product must be evaluated by an Authorized Warranty Service Center. For the location of the nearest Authorized Warranty Service Center contact the retailer or place of purchase.
warrants to the original purchaser who uses the product in a consumer
will repair or replace, at
STEELE®
STEELE®
’s sole option, products or
with regard to this limited warranty shall be
final.
Retain original cash register sales receipt as proof of purchase for warranty to work.
Use reasonable care in the operation and maintenance of the product as described in the Owner’s Manual(s).
Deliver or ship the product to the Authorized Warranty Service Center. Freight costs, if any must be paid by the purchaser.
If the purchaser does not receive satisfactory results form the Authorized Warranty Service Center, the purchaser should contact
STEELE®
.
3
2000W Generator
Limited Warranty (cont d)
THIS WARRANTY DOES NOT COVER:
• Merchandisesoldasreconditioned,usedas rental equipment, or floor or display models.
• Merchandise that has become damaged or inoperative because of ordinary wear, misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, failure to operate the product in accordance with the instructions provided in the Owner’s Manual(s) supplied with the product, improper maintenance, the use of accessories or attachments not recommended by All-Power America, or unauthorized repair or alterations.
• Repairandtransportationcostsofmerchandisedeterminenottobedefective.
• Costs associated with assembly, required oil, adjustments or other installation and start-up costs.
• Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period of use.
• MerchandisesoldbyAll-PowerAmericawhichhasbeenmanufacturedbyandidentifiedasthe product of another company, such as gasoline engines. The product manufac turer’s warranty, if any, will apply.
• ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECTS, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT COVERED BY THIS WARRANTY. Some states do not allow the exclusion, so it may not apply to you.
• IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE.Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,sothe
above limitations may not apply to you.
4
Owner s Manual
Safety Guidelines - Definitions
This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections.
Save These Important Safety Instructions!
Read and understand all of these safety instructions. Be sure to retain them for future use.
WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITYOFPERSONALINJURYORDEATHIF INSTRUCTIONSARENOTFOLLOWED.
CAUTION: CAUTIONS INDICATE A POSSIBILITY OF
EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED.
NOTE: NOTES GIVE HELPFUL INFORMATION
WARNING! IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. WHEN USING AIR TOOLS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THERISKOFPERSONALINJURY.
5
2000W Generator
General Precautions
WARNING!FAILURETOFOLLOWTHESEINSTRUCTIONS CANRESULTIN SEVEREINJURYORDEATH.
DANGER
Carbon Monoxide
Using a generator indoors WILL KILL YOU IN MINUTES.
Carbon Monoxide
Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell the exhaust, you could be breathing CO.
· NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT supply enough fresh air.
· ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.
Gasoline and Oil
This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the warranty. Work in well ventilated area. Keep cigarettes,
flames or sparks away from the work area or where gasoline is stored.
WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF CHILDREN.
• Gasoline fuel and fumes are flammable and potentially explosive. Use proper fuel storage and
handling procedures. Always have multiple ABC class fire extinguishers nearby.
• Keep the generator and surrounding area clean at all times.
• Fuel or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state, or federal codes and regulations. Store oily rags in a covered metal container.
• Never store fuel or other flammable materials near the generator.
6
Owner s Manual
General Precautions (cont’d)
Gasoline and Oil (cont’d)
• Donotsmoke,orallowsparks,flamesorothersourcesofignitionaroundtheengineandfuel
tank. Fuel vapors are explosive.
• Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or vapors.
• Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not
operate the generator with known leaks in the fuel system
• Excessive buildup of unburned fuel gases in the exhaust system can create a potentially
explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or
hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the gases to dissipate before attempting to restart the generator.
• Useonlyenginemanufacturerrecommendedfuelandoil.
Hot Components
WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE PARTS.
7
2000W Generator
General Precautions (cont’d)
Work Area
• Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
• Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes.
• Keepbystanders,children,andvisitorsawaywhileoperating a generator.Providebarriersor shields as needed.
Electrical Safety
• Grounded tools must be plugged into an outlet properly installed and g r o u n d e d i n a c c o r d a n c e w i t h a l l c o d e s a n d o r d i n a n c e s . N e v e r r e m o v e t h e grounding prong or modify the plug in any way. Do not use any adapter plugs.
• Grounding provides a low-resistance path to carry electricity away from the user in the event of an electrical malfunction.
• Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Donotchangethepluginanyway.Doubleinsulationeliminatestheneedforthethree-wire grounded power cord and grounded power supply system.
• Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators.
Thereisanincreasedriskofelectricshockifyourbodyisgrounded.
• Do not expose generator to rain or wet conditions. Water entering a generator will increase the risk of electric shock.
• Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving parts. Replace damaged power cords immediately. Damaged power cords increase the risk of electric shock.
• When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”. These extensioncordsareratedforoutdooruse,andreducetheriskofelectricshock.
8
Owner s Manual
General Precautions (cont’d)
Electrical Safety (cont’d)
• All connections and conduits from the generator to the load must only be installed by trained and
licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.
• The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation.
• Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground.
• Do not touch electrically energized parts of the generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object.
• Connect the generator only to a load or electrical system (110/120 volt) that is compatible with the electrical characteristics and rated capacities of the generator.
• Before servicing equipment powered by the generator, disconnect the equipment from its power input.
• Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked,
cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight.
• Insulate all connections and disconnected wires.
• Guard against electric shock. Prevent body contact with grounded surfaces such as pipes,
radiators, ranges, and refrigerator enclosures.
Personal Safety
• Stay alert. Watch what you are doing, and use common sense when operating a generator. Do not use generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating generators may result in serious personal injury.
• Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
9
2000W Generator
General Precautions (cont’d)
Personal Safety (cont’d)
• Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect
the spark plug wire when not in use.
• Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is
left attached to a rotating part of the generator may result in personal injury.
• Do not overreach. Keep proper footing and balance at all times.
• Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye
goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions.
• Donotforcethegenerator.Usethecorrectgeneratorforyourapplication.Thecorrectgenerator
willdothejobbetterandsaferattherateforwhichitisdesigned.
• Donotusethegeneratorifthepowerswitchdoesnotturnitonoroff.Anygeneratorthatcannot
be controlled with the power switch is dangerous and must be replaced.
Generator Use and Care
Make sure the power switch is in its “OFF” position and disconnect the spark plug wire before making any adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally.
Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users.
Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not use” until repaired.
Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator’s operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators.
Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one generator may become hazardous when used on another generator.
10
Owner s Manual
General Precautions (cont’d)
Servicing
Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact All Power America immediately for a replacement.
Generator service must be performed only qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury.
Heart Pacemakers
WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USING THIS PRODUCT. ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE INTERFERENCE TO OR FAILURE OF THE PACEMAKER.
Installation
• Ensure installation meets all applicable safety, and local and national electrical codes. Have
installation performed by a qualified, licensed electrician and building contractor.
• Allelectricalwork,includingtheearth-groundconnection,shouldbecompletedby a licensed
electrician.
• Any separate fuel storage or generator supply facility must be built or installed in full compliance
with all relevant local, state, and federal regulations.
11
2000W Generator
General Precautions (cont’d)
Installation (cont’d)
• If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It
should not be run outdoors without protection to the generator and wiring conduit.
• Thegeneratorweighs 48 lbs.Twoormorepeopleshouldassistwhenmovingorliftingthis
product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipmenttotheframeofthegenerator
• Before lifting the generator, ensure the lift rigging and supporting structure are in good
condition, and are rated to lift such a load.
• Keep all personnel away from the suspended generator during relocating.
• Thesupporting floor/groundsurfaceshouldbelevelandstrongenoughtosafelyholdtheweight
of the generator. If the floor/grounded surface is not level, strong cross members should be placed under the full length of the generator frame at its low side.
• Fortrailerinstallation,thegeneratorshouldbemountedonthecenterpointofthetrailer,over
the wheels. The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.)
• Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping
moisture within the generator’s area.
Mechanical
• Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and
allow the engine to completely cool before carrying out maintenance.
• Check for damaged parts. Before using the generator, any part that appears damaged should
be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any other condition that may affect proper operation technician.
• The generator is designed with guards for protection from moving parts. In any case, care must
still be taken to protect personnel and equipment from other mechanical hazards when working around the generator.
12
Owner s Manual
General Precautions (cont’d)
Mechanical (cont’d)
• Do not operate the generator with safety guards removed. While the generator is running, do not
attempttoreacharoundthesafetyguardformaintenanceoranyotherreason.
• Keephands,arms,longhair,looseclothing,andjewelryawayfrommovingparts.Beawarethat
whenenginepartsaremovingfasttheycannotbeseenclearly.
• Keep access doors on enclosures closed and locked when access is not required.
• WhenworkingonoraroundthegeneratoralwayswearprotectiveclothingincludingANSI
approved safety gloves, safety eye goggles, and safety hat.
• Do not alter or adjust any part of the generator that is assembled and supplied by the
manufacturer.
• Always follow and complete scheduled engine and generator maintenance.
Chemicals
• Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces.
• Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek
medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, immediately wash with soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention.
Noise
• Prolonged exposure to noise levels above 85 DBA is hazardous to hearing. Always wear ANSI
approvedearprotectionwhenoperatingorworkingaroundthegeneratorwhenitisrunning.
13
2000W Generator
General Precautions (cont’d)
Extension Cord
If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table:
shtgneLdroC@(spmAetalpemaN
full load)
0'-50' 50'-100' 100'-150' 150'-200'
0 - 5
5.1 - 8
8.1 - 12
AWG
16 16 12 12
16 14 10 -
AWG
AWG
14 12 - -
AWG
AWG
AWG
AWG
AWG
AWG
14
Battery
This product does not need a battery.
Owner s Manual
15
Loading...