Sta-Rite GW9500 Installation Manual

0 (0)
Automatic Pool Cleaner
Installation and
User’ s Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Technical Support
Sanford, North Carolina (8 A.M. to 5 P.M.)
Moorpark, California (8 A.M. to 5 P.M.)
Phone: (800) 831-7133
Fax: (800) 284-4151
Web sites: visit www.pentairpool.com and staritepool.com
© 2011 Pentair Water Pool and Spa, Inc. All rights reserved
This document is subject to change without notice
Trademarks and Disclaimers:
Great White® and Pentair Water Pool and Spa® are registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other counties. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
PN789 (Rev C) - 1/24/11
Contents
Important Safety Precautions ..............................................................................ii
Section 1: Overview ............................................................................................1
Preparation of your pool ............................................................................... 2
Cleaner assembly ............................................................................ 2
Hose Assembly ................................................................................ 3
Section 2: Installation ..........................................................................................5
Standard Installation ..................................................................................... 5
Optional Installation...................................................................................... 8
Section 3: Operation............................................................................................ 11
Cleaner Operation and Movement ............................................................... 11
Clicking sound ................................................................................ 11
Movement around the pool ...............................................................11
Picks up “big stuff” ....................................................................................... 11
Fine-tuning valves and connections ............................................................ 12
Valves (pump, skimmer, and main drain) and vacuum adjustments 12
Too much vacuum? ......................................................................... 12
Not enough vacuum? .......................................................................12
In-Line leaf canisters ........................................................................ 13
Skimmer connection ........................................................................ 13
Skimmer vac plates .........................................................................13
Skimmer vac plate vacuum control adjusters .................................. 13
i
Section 4: User Maintenance .............................................................................15
Hose Storage ............................................................................................... 15
Disassembly................................................................................................ 16
Reassembly ................................................................................................ 17
Illustrated Parts List ..................................................................................... 18
Section 5: Troubleshooting ................................................................................19
Great White Installation and User’s Guide
ii
IMPORTANT SAFETY PRECAUTIONS
Important Notice:
Attention Installer: This manual contains important information about the installation, operation and safe use
of this product. This information should be given to the owner and/or operator of this equipment.
WARNINGBefore installing this product, read and follow all warning notices and instructions which
are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.
WARNINGHazardous suction. Can trap and tear hair or body parts. Can cause drowning.
Do not play with cleaner or hose or apply to body . Do not let children use or play with pool cleaner. Stop pump before attempting to clean unit.
CAUTIONOscillator may injure hands or fingers. Stop pump before attempting to clean out
pool cleaner head.
1058 0594
WARNING — Hose can trip or entangle swimmers. Do not allow swimmers in pool while pool cleaner
is operating.
General Installation Information
Pre-installation check list
Before installing the cleaner in a vinyl liner pool:
Check liner closely for signs of deterioration or damage from age, chemicals, pool wall damage, etc. If any damage is found, have a qualified pool professional make all necessary repairs. Also, if there are stones, roots, etc., under the liner, remove them before installing the cleaner.
Before installing the cleaner in a gunite pool or a pool that is partially or completely tiled:
Repair loose tiles and tighten any loose light rings.
Before installing the cleaner, clean your filter system:
Make sure you have cleaned the filter, including backwashing, rinsing, and emptying all baskets. A clean system is necessary for proper cleaner operation and coverage.
Great White Installation and User’s Guide
IMPORTANT SAFETY PRECAUTIONS (continued)
General Installation Information (continued)
Before installing the cleaner, fill the hose with water:
Always make sure the cleaner head is submerged and the hose is full of water before connecting the hose to the filtration system (whether through a skimmer or dedicated wall fitting). Air in the system can damage the pump through dry running and overheating.
Before installing the cleaner, understand cleaner coverage:
The cleaner is designed to rid your pool of debris in approximately 4-6 hours. Less time could be needed, depending on the pool size.
The cleaner was not designed to automatically clean steps or swimouts or to work under a solar cover. It was also not designed to do initial cleanup for a new pool or when opening your pool for the season.
WARNING Suction entrapment, injury, and drowning hazard. If your pool has a dedicated
suction port (“vac port”) for vacuuming or for an automatic pool cleaner, it must be
covered when not in use.
A spring loaded safety cover is included with your cleaner. Install it on the suction port to prevent entrapment and injury.
iii
Great White Installation and User’s Guide
iv
Blank Page
Great White Installation and User’s Guide
Section 1
Overview
Great White Automatic Inground Pool Cleaner
Congratulations on your purchase of the world’ s best pool cleaner! Nothing quite compares to the Great White’ s ability to make dirt disappear. W ith its 15” cleaning path and unique bristle drive, your Great White automatic, inground pool cleaner will deliver fast, complete coverage of your pool.
1
Great White Automatic Inground Pool Cleaner
Model GW9500
Great White Installation and User’s Guide
2
r
Preparation of your pool
Before you assemble and install your Great White automatic pool cleaner , you should make sure that your pool is clean and free of algae. If necessary , make the following preparations before proceeding.
• Chemically balance the pool water
Skimmer Basket
• Brush the pool and let the debris settle
• Hand vacuum the pool thoroughly
• Clean the filter and pump strainer basket (Figure 1)
Cleaner assembly
1. Check parts
Remove Great White and all of its parts from the box and check to make sure that all components were included (Figure 2).
CleanerSwivel Assembly
Handle Adapter
Cleaner
Handle AdapterReducer ConeHose: Twelve 4’ lengthsV acuum RegulatorRegulator CapV acuum Port FittingFlow Gauge
Hose
Twelve
4’ lengths
Vacuum Port Fitting
Figure 1
W
O
L
F
W
M
O
U
L
M
F
I
X
M
U
A
M
M
I
N
I
M
Flow Gauge
Swivel Ass'y
Vacuum Regulator
Pump Straine
Reducer Cone
Regulator Cap
Figure 2
2. Attaching swivel assembly to cleaner head
Installing the swivel assembly is a snap. Just insert it into the cleaner body and give it a quarter turn (Figure 3). If you attach a unidapt handle to the swivel for manual vacuuming, be sure it is the special, floating unidapt handle provided with the cleaner (Replacement Part No. GW9019). Use of a different unidapt handle will hinder the cleaner’s performance.
Swivel Assembly
Figure 3
Great White Installation and User’s Guide
Hose Assembly
Assemble the hose
The unit includes twelve sections of hose, each 4 feet (4’) in length (Figure 4). Do not cut the hose lengths. You will need to connect these 4’ sections of hose to create a combined hose length that is
at least 4’ longer than the distance from your suction source (whether skimmer or dedicated suction line) to the farthest point in the pool (Figure 5). Connect the hoses by twisting and pushing the female ends onto the male ends after wetting the ends in the pool (Figure 6). A
special “leader” hose section is designed to connect to the cleaner’s swivel assembly and therefore has a larger hose cuff than the other hose lengths (Figures 7 and 8). Failure to use this
leader hose section to attach the hose to the cleaner’s swivel assembly
Figure 4
will hinder your cleaner’s performance. If additional hose is needed, use only hoses from your Pentair W ater Pool and Spa dealer (order replacement part No. 41200-0131). Use of another manufacturer’s hose will hinder cleaner coverage.
Hose
Twelve, 4’ lengths
3
Female hose end Male hose end
Figure 6
Hose must equal longest stretch — —
plus at least 4 feet.
Figure 5
Leader Hose
Swivel Assembly
Leader Hose
Connect to Swivel Assembly
Figure 7
Figure 8
Great White Installation and User’s Guide
4
Blank Page
Great White Installation and User’s Guide
Section 2
Installation
This section describes how to install the Great White pool cleaner . Great White is designed to work in a wide variety of swimming pools. Both the standard in-skimmer installation and optional vac port installation are covered below . If your pool configuration is unlike any of the examples, contact your Pentair W ater Pool and Spa dealer for assistance, or call our toll-free Customer Helpline at 1-800-831-7133.
Standard Installation
For pools with one skimmer, using the vacuum regulator
The manufacturer recommends the Standard Inst allation through the pool’s skimmer (Figure 8) The advantage of this installation is its use of the vacuum regulator (Figure 9) to balance the water flow between the skimmer and the Great White pool cleaner . The vacuum regulator can be adjusted to changes in the amount of water flow to provide Great White with the power necessary to ensure proper cleaning performance, and the manufacturer strongly recommends its use for maximum safety and performance.
5
Skimmer
Figure 8
1. Turn the pool pump off
2. Adjust valves for vacuuming
Adjust the pump valves (if your system has valves) to direct all suction to the skimmer . Close the main drain and all suction lines, except the line from the skimmer to which Great White will be connected.
3. Remove the skimmer basket from the skimmer
4. Install vacuum regulator
WARNING! Hazardous suction. Can cause entrapment with severe personal injury or drowning.
Use the vacuum regulator in conjunction with your pool cleaner system at all times. The vacuum regulator has an adjustment knob (Figure 9). If suction is too high, the knob is turned counterclockwise to decrease the suction. If the suction is too low , the knob is turned clockwise to increase the suction.
Vacuum Regulator
Adjustment Knob
Figure 9
Great White Installation and User’s Guide
6
Standard Installation (Continued)
The vacuum regulator must be installed in conjunction with the reducer cone (Figure 10). The reducer cone is required to make most skimmer connections. It will keep the hose and vacuum regulator in place once the filter system is stopped.
Figure 10
T o install the vacuum regulator, insert the vacuum regulator and reducer cone in the skimmer . Attach the end of the hose to the regulator (Figure 11).
Skimmer
Vacuum Regulator
Reducer Cone
To Pump
Figure 11: Vacuum regulator installed in the skimmer with the hose attached
Make sure the vacuum regulator is submerged at all times. If not, the pump will suck air through the vacuum regulator and lose prime. This could damage the pump.
Great White Installation and User’s Guide
Standard Installation (Continued)
5. Check Flow
With the main drain closed, and one end of the hose attached to the regulator installed in the skimmer , insert the flow gauge into the other end of the hose. Keep the hose and flow gauge underwater. Turn on the pump. W ith the pump running, adjust the vacuum regulator (in your skimmer) until the indicator on the flow gauge is between minimum and maximum flow (Figure 12). Remove the flow gauge and proceed to step 6.
Disc Indicator
Figure 12
7
6. Connect Hose to the Cleaner’s Swivel Assembly
Connect the large hose cuff (Figure 13) of the leader hose to the swivel assembly on the cleaner head (Figure 13). Push the cleaner into the pool and let it sink to the bottom (Figure 14).
Large hose cuff of leader hose designed to connect to swivel assembly (See “Hose Assembly” on Page 3)
Figure 13
Figure 14
7. Turn the pool pump on
After completing the installation, turn the pool pump on and allow it to run for a couple of minutes to ensure that all air cycles out of the system.
Great White Installation and User’s Guide
8
Optional Installation
Vac Port Inst allation with Vacuum Regulator in Skimmer
If your pool has a vac port (Figure 15), you can install Great White using the Optional Installation.
V ac Port
Figure 15
1. Turn the pool pump off
2. Adjust valves for vacuuming
Adjust the pump valves (if your system has valves) to direct all suction to the dedicated vacuum line and the skimmer. Close the main drain and all suction lines, except the line from the dedicated vacuum line to which Great White will be connected, and the skimmer where the vacuum regulator will be installed.
3. Install vac port door fitting
WARNING! Suction entrapment, injury, and drowning hazard. If your pool has a dedicated suction port (“vac port”) for vacuuming or for an automatic pool
cleaner, it must be covered when not in use.
A spring loaded safety cover (the “vac port fitting”) is included with this pool cleaner (Figure 16). Install it on the dedicated vacuum line to prevent entrapment and injury . For
Figure 16
details please refer to the V ac Port Instruction sheet included with your vac port fitting. T o install the included vac port fitting:
1. Screw the vac port fitting into the dedicated vacuum line opening.
2. Orient the vac port fitting so the arrow on the door points up.
3. Secure the cover by tightening the allen-screw below the door, into the dedicated vacuum line fitting.
4. Remove the skimmer basket from the skimmer
Great White Installation and User’s Guide
Optional Installation (continued)
5. Install vacuum regulator
WARNING! Hazardous suction. Can cause entrapment with severe personal injury or drowning.
T o install the vacuum regulator, insert the vacuum regulator and reducer cone in the skimmer (Figure 17).
9
Water Level
Vacuum
Regulator
with Regulator
Cap attached
Reducer Cone
Skimmer
Gate valve for vacuum port must be fully open
1900 0405
Attach hose to vac port
Figure 17: Vacuum regulator and reducer cone inserted in skimmer
T o prevent water from flowing through the top of the vacuum regulator, attach the regulator cap to the vacuum regulator (Figure 18). Attach the end of the hose to the vac port fitting installed in the dedicated vacuum line (Figure 17).
Skimmer
Regulator Cap
Vacuum Regulator
Reducer Cone
To Pump
Figure 18: Vacuum regulator installed in the skimmer with the regulator cap attached
Great White Installation and User’s Guide
10
Optional Installation (Continued)
6. Check Flow
With the main drain closed, and one end of the hose attached to the vac port fitting installed in the dedicated vacuum line, insert the flow gauge into the other end of the hose. Keep the hose and flow gauge underwater . Turn on the pump. W ith the pump running, adjust the vacuum regulator (in your skimmer) until the indicator on the flow gauge is between minimum and maximum flow (Figure 19). Remove the flow gauge and proceed to step 7.
Disc Indicator
Figure 19
7. Connect Hose to the Cleaner’s Swivel Assembly
Connect the large hose cuff (Figure 20) of the leader hose to the swivel assembly on the cleaner head. Push the cleaner into the pool and let it sink to the bottom (Figure 21).
Large hose cuff of leader hose designed to connect to swivel assembly (See “Hose Assembly” on Page 3)
Figure 20
Figure 21
8. Turn the pool pump on
After completing the installation, turn the pool pump on and allow it to run for a couple of minutes to ensure that all air cycles out of the system.
Great White Installation and User’s Guide
Section 3
Operation
This section contains information describing the movement and operation of your Great White Cleaner , as well as tips for “fine-tuning” your pool’ s valves and connections to optimize Great White’s cleaning ability .
Cleaner Operation and Movement
Clicking sound
This is the sound of the oscillator moving back and forth in the oscillator chamber. The best speed for it is about 500 oscillations per minute. The vibration created by the oscillator moves the bristles and the cleaner . If the oscillator is running too fast, the cleaner will have a tendency to climb up the pool wall past the waterline, or “walk out of the pool” and suck air. Reduce the speed by adjusting the vacuum regulator in the skimmer.
Movement around the pool
11
Random motion – The cleaner will visit most spots in the pool within a six (6) hour period. It is not specifically programmed, and cannot see the dirt you are seeing. It is a random motion pattern.
The cleaner was designed to spend most of its time in the deep end, where most of the floor and wall area exists. During a six (6) hour period, the cleaner will visit the shallow end a few times.
Rotating motion – The cleaner will rise up on one side and pivot a few times per minute. This is normal and provides the following:
1. Allows leaves that are being pushed or dragged along to be sucked up into the vacuum chamber .
2. Allows the cleaner to:
Change direction Get out of corners Get away from ladders Submerge below pool water level Get off of domed main drain covers
Picks up “big stuff”
The cleaner will pick up some debris so large that it may jam. Simply stop the pump and remove the debris from the oscillator, or the swivel assembly .
Great White Installation and User’s Guide
12
Fine-tuning valves and connections
WARNING! Pool pump suction is hazardous and can cause entrapment with severe personal
injury or drowning. Use vacuum regulator (see instructions below) in pool cleaner system at all times.
NOTICE: Each pool’s hydraulic system and vacuum connections are different. Be sure you have installed
the vacuum regulator before you “fine-tune” the system. This not only regulates vacuum, but also acts as a safety device.
WARNING! Suction entrapment, injury, and drowning hazard. If your pool has a dedicated suction
port (“vac port”) for vacuuming or for an automatic pool cleaner, it must be covered when not in use.
A spring loaded safety cover (the “Vac Port Fitting”) is included with this pool cleaner. Install it on the vac port to prevent entrapment and injury. For details please refer to the Vac Port Fitting instruction sheet included with
your cleaner.
For the novice pool owner for whom pool vacuuming is a new experience, please read all of the following points, installation instructions, and trouble shooting guide carefully .
Please note the following:
“V acuum” and “suction” are two words meaning the same thing.
“Dedicated suction line”, “vac port”, and “vac fitting” are different terms for a hole in the side wall of pool; this hole is connected to the pump suction and is dedicated to vacuuming.
Some pools do not have a vac port. If your pool does have one, please read the “Suction Entrapment” warning above.
For the seasoned pool owner: The automatic pool cleaner connection and vacuum adjustments can be similar to using your manual pool vacuum. Please read on.
Valves (pump, skimmer, and main drain) and vacuum adjustments
Y ou may need to spend some time adjusting the skimmer and main drain valves in order to obtain the best vacuum setting for good cleaner operation. Once you have found the correct valve settings for best operation, we suggest you mark the valves to ensure repeated success.
At first, set valves to give maximum vacuum to the skimmer or vac fitting you have elected to use.
Too much vacuum?
Y ou have too much vacuum if the cleaner climbs up the pool wall past the water line to the point that the cleaner sucks air and the pump loses prime. Frequent loss of prime will damage the pump. T o correct this, adjust the regulator by turning the adjustment knob counterclockwise. This will decrease the suction. If the cleaner still climbs out and sucks air, open the main drain valve slightly .
Great White Installation and User’s Guide
Fine-tuning valves and connections (continued)
Not enough vacuum?
Y ou don’t have enough vacuum if the cleaner moves sluggishly or not at all. Be sure the filter system is clean and the regulator and all valves are adjusted to give you maximum vacuum. If the cleaner is still not moving, your pump may not be strong enough to operate the cleaner. Please refer to “T roubleshooting” on Page 17.
In-Line leaf canisters
If your pool is exposed to large quantities of leaves, we suggest purchasing and installing an in-line leaf canister (part no. R211084K). A leaf canister will provide more debris-loading capacity and also provides a water by-pass when the canister is full. It is very important that the pump not starve for water!
Skimmer connection
For pools that have large quantities of “big stuff” to pick up, we suggest using the bottom of the skimmer connection in conjunction with an in-line leaf canister (part no. R211084K). A leaf canister will provide more debris-loading capacity and also provides a water by-pass when the canister is full. It is very important that the pump not starve for water!
13
Skimmer vac plates
Some pool owners connect the hose to a skimmer vac plate, which allows the skimmer basket to remain in the skimmer . If this method is used, empty the basket frequently. Also make sure that the vacuum regulator provided is completely submerged so that it will not suck air and damage the pump.
Skimmer vac plate vacuum control adjusters
Some pool owners use one of a variety of manufacturer’s skimmer vac plates. Some have a vacuum control adjuster, and some do not. The adjuster could be a screw-type, a spring loaded apparatus, or a dial design. For those vac plates with adjusters, it is important to adjust them when fine tuning the vacuum for the cleaner .
Great White Installation and User’s Guide
14
Blank Page
Great White Installation and User’s Guide
Section 4
User Maintenance
This section describes the service and maintenance of the Great White cleaner .
WARNING! Hazardous suction. S top pump before attempting to clean pool cleaner.
Keep skimmer basket and pump strainer basket clean and free of debris.
If cleaner jams with large debris (leaves, sticks, etc.), try cleaning debris first from bottom of unit. If
this doesn’t clear unit, remove top swivel assembly (turn 1/4 turn) and clear the debris from the top.
Remove the pool cleaner from the pool before super chlorinating (shocking) or chemical balancing.
W ait at least four hours after the chemical procedure before reinstalling the cleaner .
Make sure that the cleaner’s brush bristles don’t become deformed during storage. S tore the unit so
that it doesn’t sit on the bristles and so that nothing compresses them.
Do not coil the hose. Remove the hose from the cleaner when removing the cleaner from the pool.
Store the hose flat and straight.
Periodically examine bristles and vacuum skirt for wear or distortion. Replace if necessary . See
"Reassembly", Page 15.
Don't store the cleaner with the hose connected to the cleaner body or with the hose coiled. T o do
so will cause the hose to take a set or kink over a period of time. When reinstalled in the pool, the hose will tend to stay coiled and will cause the cleaner to malfunction.
If the hose has taken a set, uncoil it as far as possible without damaging it and lay it out in the sun for
several hours to straighten itself. Once it has relaxed and straightened out, store it laid out flat and straight (no coiling).
Make sure the lift brush is retracted during storage. If the lift brush is down during storage and the
cleaner rests on it, the brush bristles will collapse over time and the cleaner will no longer turn during operation as it was designed to do.
15
Hose Storage
Correct: Hose stored correctly –
laid out straight, not connected to cleaner.
Wrong: Storing cleaner with hose connected will damage hose and void the hose warranty.
Great White Installation and User’s Guide
16
2. Slide metal ratchet tab down through cleaner body
1884 0795
Disassembly
1. Remove swivel assembly (Figure 22) from the top of the cleaner by turning it 1/4-turn counterclockwise and pulling straight up on it.
2. Turn cleaner upside down. Remove 4 screws and remove lower body assembly from shroud.
3 . Turn lower body assembly right side up. Unsnap
the 2 clips on the oscillator chamber cap (Figure 23a); lift it off.
4. Pull the long gear shaft straight up (Figure 23a) by the blocks on the ends of the shaft. Hold the seals in the oscillator and the blocks on the shaft. The cam may interfere with the shaft mounting post; if so, turn it slightly on the shaft until it clears the post. The shaft assembly can now be disassembled (Figure 23b).
5. Slide the long gear shaft out of the oscillator (with gears, complete); make sure that you don’t lose the seals out of the oscillator which may fall out at this point (Figure 23b).
5A. Oscillator seals are replaceable. 5B.Ratchet gear set and long shaft are replaceable
as a unit.
Swivel assembly
Figure 22
Ocillator Chamber Cap
Long Gear Shaft
Block
Figure 23a
"Click" at this point
3337 1098
Locked Twist CCW
Clip
Block
Cam
1889 0795
1/4 Turn
Figure 23b
Pull Straight Up
1887 0795
6. Remove the set screw, short gear shaft, and gears (Figure 24); be sure to keep the gears on.
7. With a small screwdriver (such as a jeweler’s screwdriver), a pencil, or a pen point, depress and remove the coil spring from the lift brush mounting post (Figure 25). Replace the brush and the spring if necessary.
8. The metal ratchet tab slides out of its slot sideways; replace it by removing the center brushes and sliding in a new ratchet tab until it is flush with the edge of plastic holder (Figures 26 and 27). Replace the center brushes.
9. The brush ring pops out of the cleaner body for easy replacement.
10. If you need to replace the bumper, turn the shroud and bumper assembly upside down and remove the two screws holding the bumper to the shroud.
Figure 24
1. Slide metal ratchet tab toward end of cleaner body
1885 0795
1886 0795
Figure 25
Great White Installation and User’s Guide
Figure 26
Figure 27
Reassembly
1. Put both white seals in the oscillator; hold them in place.
2. Install the oscillator on the long gear shaft. Install the
ratchet gear on the shaft so that the teeth engage the ratchet on the oscillator. Install the spring, ratchet drum, pinion gear (large gear first), and cam (gear end first) on the shaft (See Figure 28). Hold the gears on the shaft while installing them, and compress the clutch spring to allow assembly to slip into place between the posts (See Figure
28).
3. Install the long gear shaft and end blocks in the cleaning
head with the large arm of the cam down (see Figure 29).
4. Reinstall the short gear shaft, set screw and two gears
(See Figure 30); the small pinion gears and the shaft set screw go on the side toward the end of the cleaner – away from the oscillator box. Make sure that the gears engage the gears on the long gear shaft.
5. Install the oscillator chamber cap and clip it in place.
6. Install the rubber vacuum skirt on the cleaner with the
word ‘OUTSIDE’ showing. Start at the large pin on the back of the cleaner head (see Figure 31) and work around the cleaner. Make sure the skirt is flush against the stop strips on the cleaner head (see Figure 32).
Seals
Figure 28
Oscillator Chamber
Figure 29
Make sure Oscillator is partially inserted in chamber while reinstalling Shaft Assembly
Swing Cam Arm up for Clearance
1895 0795
17
1894 0795
7. Turn the cleaner over. If you removed the bumper and
brush ring, replace them now.
8. Install the lower body assembly in the shroud. Fasten the
cleaning head in place with 4 screws (2 long, 2 short – see Figure 33).
NOTE: Make sure that you do not dislodge the rubber vac skirt while inserting the lower body assembly past the brush
ring.
Not This
This
Figure 32
Center Brush Location
Figure 33
#10-16x1-3/4" Screws
#10-16x1" Screws
Bottom View of Cleaner
1892 0795
1891 0795
Lift Brush Location
Center Brush Location
Start here with large button when installing vacuum skirt.
Figure 31
Figure 30
'Outside' will show (facing out) when skirt is correctly installed.
OUTSIDE
1893 0795
1890 0795
Rubber vacuum skirt
Great White Installation and User’s Guide
18
R
Illustrated Parts List
3
18
9
17
3
3
16
19
15
1
1896 0795
8
9
10 11
11A
8
3
12
13
14
Optional Accessories
Vacpole
2
2A
3
4
5
6
7
Key
No.
Description Part No.
1 Swivel Assembly GW9012 2 Bumper GW9502
2A Bumper Insert Kit (Set of 4) GW9520
3 Screw Kit (4 short, 2 long) GW9504 4 Shroud GW9501 5 Brush Ring GW9505 6 Oscillator Chamber Cap GW9506 7 Cam Kit (2 & 3 Leg Cams) GW9507 8 Idler Gear Kit (Incl. 3 Gears) GW9509
9 Block Kit (Incl. 2 Blocks) GW9512 10 Long Gear Shaft (Stainless Steel) GW9513 11 Set Screw #4 Self Tapping##
11A Shaft Kit, Stainless Steel (includes Set Screw) GW9536
12 Lower Body* GW9535 13 Lift Brush GW9517 14 Vacuum Skirt GW9508 15 Lift Brush Spring GW9522 16 Ratchet Tab (Stainless Steel) GW9523 17 Oscillator Seal Kit (Incl. 2 Seals) GW9004 18 Oscillator Assembly Kit (Incl. Key #17)
(Ratchet Assembly not sold separately)
19 Center Brush Kit (Set of 2) GW9013
Hose Kit, 12 sections, each 4 ft in length 41200-0131
Vacuum Regulator 41200-0200
Vacuum Regulator Cap 41200-0211
Reducer Cone GW9015
Unidapt Handle GW9019
Vac Port Fitting GW9530
Flow gauge 41200-0210
Not Illustrated * Includes Key Nos. 6, 11A, 13, 15, 16, two idler gears and 2-arm cam
## Not available separately
1897 0405
GW9503
Great White Installation and User’s Guide
Loading...