Single Zone Expander
(RP128EZ01)
The RISCO RP128EZ01 is a Single Zone Expander that enables to connect any detector to RISCO system
BUS. Using the BUS connection you can ease your installation by connecting any detector in parallel
connections from any point along the wiring route. In addition you can define any detector with one of
the following zone terminations supported by the panel: NO, NC, EOL, DEOL, TEOL.
The following instructions explain how to connect to the RP128EZ01 the ProSYS.
Notes:
1. Up to 32 Single Zone Expanders can be installed on the ProSYS main BUS.
2. Up to 128 Single Zone Expanders can be assigned to the ProSYS using the BUS Zone Expander.
The following instructions explain how to connect a detector to the ProSYS BUS using the RP128EZ01.
Installation
1. Set the RP128EZ01 ID number (1-32) using DIP switches 1-5.
SW1 (1 - 5): ID switches. Defines the Single BUS Zone Expander ID number
SW1 - 6: Not used
ID DIP - 1 DIP - 2 DIP - 3 DIP – 4 DIP - 5 ID DIP - 1 DIP - 2 DIP - 3 DIP - 4 DIP - 5
1 Off Off Off Off Off 17 Off Off Off Off On
2 On Off Off Off Off 18 On Off Off Off On
3 Off On Off Off Off 19 Off On Off Off On
4 On On Off Off Off 20 On On Off Off On
5 Off Off On Off Off 21 Off Off On Off On
6 On Off On Off Off 22 On Off On Off On
7 Off On On Off Off 23 Off On On Off On
8 On On On Off Off 24 On On On Off On
9 Off Off Off On Off 25 Off Off Off On On
10 On Off Off On Off 26 On Off Off On On
11 Off On Off On Off 27 Off On Off On On
12 On On Off On Off 28 On On Off On On
13 Off Off On On Off 29 Off Off On On On
14 On Off On On Off 30 On Off On On On
15 Off On On On Off 31 Off On On On On
16 On On On On Off 32 On On On On On
2. Wire the RP128EZ01 BUS wires Red, Black (COM), Yellow(BUS) and Green (BUS) to the
ProSYS BUS.
Notes:
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring from the
ProSYS BZ1 to the ProSYS panel or to the BUS Zone Expander.
Wiring RP128EZ01 to the Main BUS
-1-

Wiring RP128EZ01 to BUS Zones Expanders
Notes:
When connecting RP128EZ01 to a BUS Zone Expander wire the RP128EZ01 wires to the relevant BUS zone
expander's terminals marked as TO DEVICE.
3. Wire the RP128EZ01 zone wires, Black and White, to the detector's terminals according to the
required termination.
Notes:
The Black and White wires are equivalent to zone input terminals in the ProSYS.
4.7K
4.7K
-2-