PACE MTS 200 SC, MTS 200 SA, MTS 300, MTS 350 Service Manual

0 (0)

Operation and Maintenance Manual for MTS Rework Systems

 

P/N 5050-0520, Rev B

 

 

Voltage

Part Number

MTS 200 SC System

115 VAC

8007-0414

MTS 200 SC System

230 VAC

8007-0415

MTS 200 SA System

115 VAC

8007-0412

MTS 200 SA System

230 VAC

8007-0413

MTS 300 System

115 VAC

8007-0418-B

MTS 300 System

230 VAC

8007-0419-B

MTS 350 System

115 VAC

8007-0416-B

MTS 350 System

230 VAC

8007-0417-B

(MTS 200 Shown with optional TD-100 and SX-80 Handpieces)

 

MTS Systems Operation Manual

Table of Contents

 

Introduction ..............................................................................................................

3

Applicable Regulations ............................................................................................

3

Specifications ...........................................................................................................

3

Environmental Requirements...................................................................................

3

Electrical Specification .............................................................................................

4

Parts Identification....................................................................................................

4

Safety .......................................................................................................................

5

System Set-Up .........................................................................................................

5

Mounting Options ........................................................................................

5

System Power-Up .......................................................................................

5

Handpieces ..............................................................................................................

6

Handpiece Tip & Tool Stands .....................................................................

6

Adjusting the Angle of the Cubby................................................................

6

Handpiece Connection................................................................................

6

Operation of MTS Systems......................................................................................

6

Vacuum Pump Operation.........................................................................................

7

Handpiece Vacuum/Pressure ..................................................................................

8

Accessories & Replacement Parts...........................................................................

8

Corrective Maintenance ...........................................................................................

9

Handpieces .................................................................................................

9

Power Source..............................................................................................

9

Packing Contents .....................................................................................................

9

Replacement Power Modules ..................................................................................

9

Service .....................................................................................................................

9

PACE WORLDWIDE LIMITED WARRANTY STATEMENT....................................

10

Contact Information..................................................................................................

11

©2004 PACE Inc., Annapolis Junction, Maryland

Page 2 of 11

All Rights Reserved

 

MTS Systems Operation Manual

General Information

Introduction

The MTS family of rework systems offer the greatest level of flexibility for your operations. PACE offers 10 different handpieces that can be used with the MTS systems. MTS systems feature HEATWISE performance control technology. The key to HEATWISE is PACE’s POWERMODULES. Power Modules control the performance level of the attached handpiece(s) and a wide range of Power Modules are available. Power Modules are clearly visible from a distance so you can tell what performance level operators are using for quick and easy process verification and by restricting access to POWERMODULES, you can protect your process by locking operators into using the performance level you specify. The MTS 200 is available in a self contained version as well as a shop air version. The MTS 200 provides 2 handpiece channels that are active simultaneously. One channel can power any of PACE’s Heater Cartridge (HC) handpieces and the other can power any of PACE’s Fixed Heater (FH) Handpieces. See chart below. The MTS 300/350 provides 3 handpiece channels that are simultaneously active. The MTS 300 features 2 HC channels and one FH channel, the MTS 350 features 1 HC channel and 2 FH channels. The system also comes standard with AutoSetback and Auto-Off functions to preserve tip life.

Applicable Regulations

MTS systems are available in either 115 VAC or 230 VAC versions, which incorporate a highly responsive, closed loop control system providing up to 150 Watts of total output power. The 230 VAC version system bears the CE Conformity Marking, which assures the user that it conforms to EMC 89/336/EEC.

The 115 VAC version systems conform to FCC Emission Control Standard, Title 47, Subpart B, Class A. This standard is designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

Specifications

Specification

MTS 200

 

MTS 300/350

Power

97-127 VAC 50/60 Hz, 200 W Max

 

97-127 VAC 50/60 Hz, 200 W Max

Requirements

or

 

or

 

197-253 VAC 50/60 Hz, 200 W Max

 

197-253 VAC 50/60 Hz, 200 W Max

Dimensions

184mm H x 107mm W x 122mm D

 

184mm H x 107mm W x 122mm D

 

(7.25” H x 4.2” W x 4.8” D)

 

(7.25” H x 4.2” W x 4.8” D)

Weight

3.8 Kgs (8.3 lbs)

 

 

Tip to Ground

< 2

Ohms

Resistance

 

 

 

Temperature

Within +/- 5 °C (9 °F), idle tip temperature

Stability

 

 

 

Abs. Temp.

 

N/A

Accuracy

 

 

 

Performance

260 °C - 454 °C (500 °F – 850 °F)

Level Range

Available Power Module Performance Levels: 5, 5.5, 6, 6.5, 7, 7.5, 8, & 8.5

Environmental Requirements

Ambient Operating Temperature: 0 ºC to 50 ºC (32 ºF to 120 ºF) Storage Temperature: -20 ºC to 75 ºC (-4 ºF to 170 ºF)

95% Humidity, non-condensing max.

©2004 PACE Inc., Annapolis Junction, Maryland

Page 3 of 11

All Rights Reserved

 

PACE MTS 200 SC, MTS 200 SA, MTS 300, MTS 350 Service Manual

MTS Systems Operation Manual

Electrical Specifications

MTS 200 1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max Fuse: 2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System

MTS 300 1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max Fuse: 2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System

MTS-350 1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max Fuse: 2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System

Parts Identification

Power Module Ports

Power Switch

Setback/Auto-

Off Switches

Earth Ground Receptacle

LED Indicators

Power Receptacles

Controllable Pressure

Port

MTS 200 Shown Auto Snap-Vac Port

AC Power Receptacle/Fuse

Holder

©2004 PACE Inc., Annapolis Junction, Maryland