© 2016 Mindray Confidential
DC-40
Scanning with
Exceptional Capability
© 2016 Mindray Confidential
• Enhanced confidence
• Exceptional capability
• Increased efficiency
• Ergonomic design
DC-40
© 2016 Mindray Confidential
Enhanced confidence
Image optimization technology
Wide range transducers offer the best
balanced performance
•PSH
•iBeam
•iClear
•Up to 15
•High density
•High frequency
•Bi-plane…
© 2016 Mindray Confidential
Phase Shift Harmonic Imaging(PSH)
5 10 15 20
-40
-30
-20
-10
0
Frequency (MHz)
Magnitude (dB)
Fundamental
Harmonic
0
0 10 20 30 40
-40
-30
-20
-10
0
Frequency (MHz)
Magnitude (dB)
(d)
Harmonic
Fundamental
• Purified harmonic imaging for better contrast resolution
• High S/N ratio to get better noise suppression
Enhanced
confidence
Exceptional
capability
Increased
efficiency
Ergonomic
design
PSH off PSH on
© 2016 Mindray Confidential
iBeam
• Combine multiple angle-steered images into one, no frame rate drop
• Better contrast resolution
• Less shadow for more information
iBeam on
Enhanced
confidence
Exceptional
capability
Increased
efficiency
Ergonomic
design
© 2016 Mindray Confidential
iClear
• Detect different structures then separate them into 3 categories:
Edge: Sharpen it and make it more continuous
Uniform tissue: Smooth it
No echo area: Clean the noise
• Better contrast resolution
• Clearer and sharper tissue border definition
Enhanced
confidence
Exceptional
capability
Increased
efficiency
Ergonomic
design
iClear off iClear on
© 2016 Mindray Confidential
Wide range transducers
Enhanced
confidence
Exceptional
capability
Increased
efficiency
Ergonomic
design
• Total 15 transducers
• 192 elements high density linear
probe
• 1.3-16 MHz wideband frequency
Convex
Volume
Endo-
cavity
Pedoff
Sector
3C5A
6C2
7L4A
L12-3E
L14-6NE
L14-6
L7-3
7L5
V11-3
V10-4B
CB10-4E
P4-2
P7-3
D7-2E
CW5s
Linear
© 2016 Mindray Confidential
• Enhanced confidence
• Exceptional capability
• Increased efficiency
• Ergonomic design
DC-40
© 2016 Mindray Confidential
General imaging
Exceptional capability
Natural Touch Elastography:
higher stiffness sensitivity; Good stability
and reproducibility
UWN Contrast Imaging: for
better visualization of tiny vessel
perfusion
iScape: show whole anatomical
structures
Auto IMT: for cardiovascular risk
assessment
Smart Bladder:auto measurement of
bladder volume
3D/4D: rich rendering modes
iLive: revolutionary technology for amazing
realistic view of fetus
iPage: display volume data with multiple parallel
2D images
Smart OB: auto measure of most frequently
used items
Smart NT: auto measure of NT
IVF package
TDI & TDI QA: for myocardial movement
and synchronization evaluation
Free Xros M: provide more anatomical
precise observation
Free Xros CM: evaluate myocardial motion,
determine myocardial synchronization
Auto LV: simple measurement procedure for left
ventricle
OB/GYN
Cardiology
© 2016 Mindray Confidential
Use different color to code different strain values, displaying the tissue stiffness for tumor
evaluation
Elastography of Thyroid
Natural Touch Elastography
*Available on Thyroid, Breast and MSK modes of 7L4A, L12-3E and L14-6NE
** The Elastography feature is designed for Imaging, will not support quantitative analysis
Enhanced
confidence
Exceptional
capability
Increased
efficiency
Ergonomic
design
• Stress bar indicators make you scan much
easier
• Support B+E dual display mode
• Excellent reproducibility with consistence
• Stiffness sensitive, and less user dependent