Lg Lan096hv, Lan126hv, Lan186hv, Lan246hv, Lau246hv Installation Guide

0 (0)

website http://www.lgservice.com

LG

LG

Room Air Conditioner

INSTALLATION MANUAL

ESPAÑOL FRANÇAIS ENGLISH

IMPORTANT

Please read this instruction manual completely before installing the product.

When the power cord is damaged, replacement should be performed by authorized personnel only.

Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

Room Air Conditioner Installation Manual

TABLE OF CONTENTS

Installation

Required Parts

Requirements

Safety Precautions............................

4

Introduction........................................

7

Symbols used in this manual..........

7

Features ...........................................

7

Installation ..........................................

8

Installation parts...............................

8

Installation tools ...............................

8

Installation map................................

9

Selecting the best location ...........

10

Piping length and elevation...........

11

Fixing installation plate..................

12

Drilling a hole in the wall ...............

12

Flaring work ...................................

13

Connecting the piping ..................

14

Connecting the cables ..................

20

Checking the drainage ..................

23

Forming the piping.........................

24

Air purging......................................

25

Test running ...................................

27

Installation guide at the seaside ...

29

Four type "A" screws & plastic anchors

Connecting cable

Installation guide map

Pipes: Gas side

Liquid side

Insulation materials

Additional drain pipe

[Outer diameter......15.5mm(0.61in)]

Two type "B" screws

Required Tools

Level gauge

Screw driver

Electric drill

Hole core drill [ø70mm(2.76in)]

Horizontal meter

Flaring tool set

Specified torque wrenches 1.8kg.m, 4.2kg.m, 5.5kg.m, 6.6kg.m

(different depending on model No.)

Spanner ........................Half union

A glass of water

Screw driver

Hexagonal wrench(4mm)

Gas-leak detector

Vacuum pump

Gauge manifold

Owner's manual

Thermometer

Remote control holder

2 Room Air Conditioner

Wall Mounted Mini-Split System

Single Zone

INSTALLATION INSTRUCTIONS

IMPORTANT!

 

Please read this instruction

installing the product.

This air conditioning system meets strict

. As the installer or service person,

it is an important part of your job to install or

operates safely and efficiently.

WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

CAUTION: Improper installation, adjustment,

can void the warranty.

The weight of the condensing

proper handling procedures when lifting

or moving to avoid personal injury

with sharp or pointed edges.

Safety Precautions

 

• Always wear safety eye wear

installing equipment.

• Never assume electrical power

with meter and equipment.

• Keep hands out of fan areas

to equipment.

• R-410A causes frostbite burns.

 

• R-410A is toxic when burned.

 

NOTE TO INSTALLING DEALER: The

Warranty are to be given to the owner

or

the indoor Furnace/Air Handler Unit.

WARNING

When wiring:

Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When transporting:

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.

When installing...

... in a wall: Make sure the wall is strong enough to hold the unit's weight.

It may be necessary to construct a strong wood or metal frame to provide added support.

... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to wall and floors.

... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When connecting refrigerant tubing

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Check carefully for leaks before starting the test run.

When servicing

Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

ENGLISH

Installation Manual 3

Safety Precautions

Safety Precautions

or other people and property damage, the following instructions

the air conditioner.

specified here as they include important items related to safety. instruction will cause harm or damage. The seriousness is

.

indicates the possibility of death or serious injury.

indicates the possibility of injury or damage to properties only.

used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Always perform grounding.

Don’t use a power cord, a

 

 

plug or a loose socket which

 

 

is damaged.

• Otherwise, it may cause

• Otherwise, it may cause a fire

electrical shock.

or electrical shock.

Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

If the electrical part cover of the indoor unit and the service

Always install an air leakage breaker and a dedicated switching board.

No installation may cause a fire and electrical shock.

For installation of the product, always contact the service center or a professional installation agency.

Otherwise, it may cause a fire, electrical shock, explosion or injury.

Do not keep or use flammable gases or combustibles near the air conditioner.

Otherwise, it may cause a fire or the failure of product.

Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

• It may cause injury or an accident.

Do not disassemble or repair the product randomly.

• It will cause a fire or electrical shock.

4 Room Air Conditioner

 

Safety Precautions

 

 

Do not install the product at a place that there

Use caution when unpacking and installing.

is concern of falling down.

 

• Otherwise, it may result in personal injury.

• Sharp edges may cause injury.

Operation

Do not share the outlet with other appliances.

It will cause an electric shock or a fire due to heat

Take care so that the power cord may not be pulled during operation.

Otherwise, it may cause a fire or electrical shock.

Do not use the damaged power cord.

Otherwise, it may cause a fire or electrical shock.

Unplug the unit if strange sounds, smell, or smoke comes from it.

Otherwise, it may cause electrical shock

Do not modify or extend the power cord randomly.

Otherwise, it may cause a fire or electrical shock.

Keep the flames away.

Otherwise, it may cause a fire.

Do not use the near the heating

Otherwise, it and electrical

Hold the plug when taking it

It may cause and damage.

shock.

Do not step on the indoor/outdoor unit and

Do not place a heavy object on the power

do not put anything on it.

cord.

• It may cause an injury through dropping of the

• Otherwise, it may cause a fire or electrical

unit or falling down.

shock.

When the product is submerged into water,

Take care so that children may not step on

always contact the service center.

the outdoor unit.

• Otherwise, it may cause a fire or electrical

• Otherwise, children may be seriously injured

shock.

due to falling down.

ENGLISH

Installation Manual 5

Safety Precautions

Installation

Install the drain hose to ensure that drain can be securely done.

• Otherwise, it may cause water leakage.

Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.

Otherwise, it may cause dispute with the neighbors.

Always inspect gas leakage after the installation and repair of product.

• Otherwise, it may cause the failure of product.

Keep level parallel in installing the product.

Otherwise, it may cause vibration or water leakage.

Operation

Avoid excessive cooling and perform ventilation sometimes.

• Otherwise, it may do harm to your health.

Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.

The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles.

Do not place obstacles around the flow inlet or outlet.

• Otherwise, it may damage your properties.

Otherwise, it may cause the failure of appliance or an accident.

6 Room Air Conditioner

Introduction

Introduction

SymbolsusedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

ENGLISH

Air Inlet

Plasma Filter

Air Filter

Front Panel

Signal Receptor

Air Intake Vents

Connecting

 

Wires

Air Outlet Vents

Drain Hose

Base Plate

Installation Manual 7

Lg Lan096hv, Lan126hv, Lan186hv, Lan246hv, Lau246hv Installation Guide

Installation

Installation

Read carefully, and then follow step by step.

InstallationParts

Type 1

Installation plate

Type 2

Installation plate

Type "B" screw

Type "B" screw

Type "A" screw (6 EA)

Type "A" screw (8 EA)

Remote control holder

Remote control holder

InstallationTools

Figure

Name

Figure

Name

 

Screw driver

 

Ohmmeter

 

Electric drill

 

Hexagonal wrench

 

Measuring tape, Knife

 

Ammeter

 

Hole core drill

 

Gas-leak detector

 

Spanner

 

Thermometer,

 

 

Horizontal meter

 

 

 

 

Torque wrench

 

Flaring tool set

8 Room Air Conditioner

Installation

InstallationMap

NOTICE

Installation parts you should purchase.

 

Installation plate

 

Sleeve

 

Bushing-Sleeve

 

Putty(Gum Type Sealer)

 

Bend the pipe as closely

 

on the wall as possible,

 

but be careful that it

 

doesn't break.

Air Discarge

 

Vertical Air deflector

 

Operation Indication Lamps/

Vinyl tape (Wide)

Signal Receptor

• Apply after carrying out a

 

Forced Operation Button

drainage test.

 

• To carry out the drainage

Saddle

test, remove the air filters

and pour water into the heat

 

exchanger.

ENGLISH

Air Inlet Vents

Air Outlet Vents

Base Plate

Gas side piping (Optional Parts)

Liquid side piping (Optional Parts)

Additional drain pipe

Vinyl tape (Narrow) Drain Hose

Connecting cable (Optional Parts)

Installation Manual 9

Installation

SelectthebestLocation

Indoor unit

1.Do not have any heat or steam near the unit.

2.Select a place where there are no obstacles in front of the unit.

3.Make sure that condensation drainage can be conveniently routed away.

4.Do not install near a doorway.

5.Ensure that the interval between a wall and the left (or right) of the unit is more than 10cm(3.9in). The unit should be installed as high as possible on the wall, allowing a minimum of 20cm(7.9in) from ceiling.

More than

 

10cm(3.9in)

than

 

 

.9in)

 

More than

 

10cm(3.9in)

2

 

6.Use a metal detector or metal scanner to locate studs to prevent unnecessary damage to the wall.

Outdoor unit

1.If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

2.Ensure that the space around the back and sides is more than 30cm(11.8in). The front of the unit should have more than 70cm(27.6in) of space.

3.Do not place animals and plants in the path of the warm air.

4.Take the weight of the air conditioner into account and select a place where noise and vibration are minimum.

5.Select a place where the warm air and noise from the air conditioner do not disturb neighbors.

More than 60cm(23.6in)

More than More than 30cm(11.8in) 30cm(11.8in)

More than

More than

70cm(27.6in)

60cm(23.6in)