Lg Arnu073tjc2, Arnu093tjc2, Arnu123tjc2 Installation Guide

0 (0)

LG

System

Indoor Unit (2 Series)

INSTALLATION MANUAL

Type: Ceiling Cassette - 1Way

IMPORTANT

Please read this installation manual completely before installing the product.

Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

ESPAÑOL FRANÇAIS ENGLISH

IMPORTANT!

Please read this instruction sheet completely before installing the product.

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

CAUTION: Improper installation, adjustment, alteration, service or maintenance can void the warranty. The weight of the condensing unit requires caution and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.

Safety Precautions

Always wear safety eye wear and work gloves when installing equipment.

Never assume electrical power is disconnected. Check with meter and equipment.

Keep hands out of fan areas when power is connected to equipment.

R-410A causes frostbite burns.

R-410A is toxic when burned.

NOTE TO INSTALLING DEALER: The Owners Instructions and Warranty are to be given to the owner or prominently displayed near the indoor Furnace/Air Handler Unit.

Special warnings

When wiring:

Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When transporting:

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.

When installing...

... in a wall: Make sure the wall is strong enough to hold the unit's weight.

It may be necessary to construct a strong wood or metal frame to provide added support.

... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to wall and floors.

... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When connecting refrigerant tubing

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Check carefully for leaks before starting the test run.

When servicing

Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

2 Indoor Unit

Ceiling Cassette - 1Way Type Indoor Unit Installation Manual

TABLE OF CONTENTS

Installation Requirements

Installation Parts ....................

4

Safety Precautions.................

5

Installation

 

Selection of the best location 8

Ceiling dimension and hang-

ing bolt location ......................

9

Wiring Connection...............

10

Installation of Decoration

 

Panel ....................................

11

Drain Piping .........................

12

Installation of Wired Remote

Controller..............................

14

Optional Operation of

 

Wired Remote Controller.....

16

Required Parts

Required Tools

Installation guide map

Four type "A" screws & plastic anchors

Connecting cable

Pipes: Gas side

Liquid side

(Refer to Product Data)

Insulation materials

Additional drain pipe

Level gauge

Screw driver

Electric drill

Hole core drill

Horizontal meter

Flaring tool set

Specified torque wrenches (different depending on model No.)

Spanner .......Half union

Hexagonal wrench

Gas-leak detector

Vacuum pump

Gauge manifold

Owner's manual

Thermometer

ENGLISH

Installation Manual 3

Installation Parts

Installation Parts

Anti-bacteria filter

Air Outlet

Air Intake

Wired Remote

Controller

Name

Drain hose

Clamp metal

Washer for

Plastic band

Insulation for

Conduit

(Other)

hanging backet

fitting

mounting plate

 

 

 

 

 

Quantity

1 EA

2 EA

8 EA

4 EA

1 SET

1 EA

• Paper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pattern for

 

 

 

 

 

 

 

installation

 

 

 

 

 

 

 

• Owner's

Shape

 

 

 

 

 

 

manual

 

 

 

 

for gas pipe

 

• Installation

 

 

 

 

 

 

 

manual

 

 

 

 

 

for liquid pipe

 

 

4 Indoor Unit

Lg Arnu073tjc2, Arnu093tjc2, Arnu123tjc2 Installation Guide

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Be sure to read before installing the air conditioner.

Be sure to observe the cautions specified here as they include important items related to safety.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

■ Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

• There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

Do not disassemble or repair the product. There is risk of fire or electric shock.

Always ground the product.

• There is risk of fire or electric shock.

ENGLISH

Install the panel and the cover

Always install a dedicated cir-

of control box securely.

cuit and breaker.

• There is risk of fire or electric shock.

• Improper wiring or installation may

 

cause fire or electric shock.

Use the correctly rated breaker or fuse.

• There is risk of fire or electric shock.

Installation Manual 5

Safety Precautions

Do not modify or extend the power cable.

• There is risk of fire or electric shock.

For installation, always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

Moisture may condense and wet or damage furniture.

Do not install the product on a defective installation stand.

Be cautious when unpacking and installing the product.

Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.

Be sure the installation area does not deteriorate with age.

• It may cause injury, accident, or

• If the base collapses, the air condi-

damage to the product.

tioner could fall with it, causing prop-

 

erty damage, product failure, and

 

personal injury.

Do not store or use flammable gas or combustibles near the product.

• There is risk of fire or failure of product.

Gasolin

6 Indoor Unit

Loading...
+ 11 hidden pages