1. Specification

 

Indoor unit type

 

Ceilling Cassette - 4way

 

 

 

 

 

 

Model

 

AMNW12GTRA0[LMCN125HV]

AMNW18GTQA0[LMCN185HV]

Decoration Panel Name

 

PT-UQC

PT-UQC

Power Supply

 

Ø / V / Hz

1/ 208~230/ 60

1/ 208~230/ 60

 

 

 

 

 

Capacity(*)

 

Btu/h class

12,000

18,000

 

 

 

 

 

Current

Running Current

A

0.25

0.25

 

 

 

 

 

Fan

Motor Type

 

BLDC

BLDC

 

 

 

 

 

 

Fan Type

 

Turbo Fan

Turbo Fan

 

 

 

 

 

 

Motor Output(W) x No. of Unit

43 x 1

43 x 1

 

 

 

 

 

 

Air Flow Rate

CMM

9.5/ 8/ 7

13/ 12/ 11

 

 

 

 

 

 

(H / M / L)

CFM

335/282/247

459/424/388

 

 

 

 

 

 

External Static Pressure

mmAq

-

-

 

 

 

 

 

 

Capacitor

µF / Vac

-

-

 

 

 

 

 

 

Drive

 

Direct Drive

Direct Drive

 

 

 

 

 

Coil

Row x Column x FPI

 

2R x 8C x 18

2R x 10C x 18

 

 

 

 

 

Dimensions

Body

mm(inch)

570 x 214 x 570 ( 22 7/16 x 8 7/16 x 22 7/16)

570 x 256 x 570 ( 22 7/16 x 10 x 22 7/16)

 

 

 

 

 

(W x H x D)

Decorative Panel

mm(inch)

700 x 30 x 700 (27 6/19 x 1 3/16 x 27 6/19)

700 x 30 x 700 (27 6/19 x 1 3/16 x 27 6/19)

 

 

 

 

 

Net Weight

Body

kg (lbs)

14 (30.9)

15 (33.1)

 

 

 

 

 

 

Decorative Panel

kg (lbs)

3 (6.6)

3 (6.6)

 

 

 

 

 

Air Filter

 

 

Long life filter

Long life filter

 

 

 

 

 

Sound Level (H / M / L)

dB(A)+3

38/ 35/ 32

38/ 37/ 34

 

 

 

 

 

Piping

Liquid

mm (inch)

6.35 (1/4)

6.35 (1/4)

 

 

 

 

 

Connections

Gas

mm (inch)

9.52 (3/8)

12.7 (1/2)

 

 

 

 

 

 

Drain(OD/ID)

mm(inch)

32 / 25(1.26/0.984)

32 / 25(1.26/0.984)

 

 

 

 

 

Dehumidification Rate

l/h

2

2

 

 

 

 

 

Safety Devices

 

 

Fuse, thermal protector for fan motor

Fuse, thermal protector for fan motor

 

 

 

 

 

Temperature Sensor

 

 

Thermistor

Thermistor

 

 

 

 

 

Referigerant

 

 

R410A

R410A

 

 

 

 

 

Referigerant Control

 

 

EEV(in Outdoor unit)

EEV(in Outdoor unit)

 

 

 

 

 

Transmission Interunit Cable

No. x AWG

4X18(Including Earth)

4X18(Including Earth)

 

 

 

 

 

Note:

1.Capacities are based on the following conditions:

Cooling: - Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F)

-Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F)

Heating: - Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

-Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.)

-Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.The specification may be subject to change without prior notice for purpose of improvement.

4.For more Capacity(*),refer to the combination table

Conversion Formula

kW = Btu/h class X 0.0002931

cfm = CMM x 35.3

Copyright ©2009 LG Electronics. Inc. All right reserved.

- 2 -

Only for training and service purposes

LGE Internal Use Only

 

2. FunctionTable

Category

Function

AMNW12GTRA0

AMNW18GTQA0

[LMCN125HV]

[LMCN185HV]

 

 

 

 

 

 

 

Air supply outlet

4

4

 

 

 

 

 

Airflow direction control(left & right)

X

X

 

 

 

 

 

Airflow direction control(up & down)

Auto

Auto

 

 

 

 

 

Auto swing(left & right)

X

X

 

 

 

 

Air flow

Auto swing(up & down)

O

O

 

 

 

Airflow steps(fan / cool / heat)

4/5/4

4/5/4

 

 

Chaos swing

X

X

 

Chaos wind(auto wind)

O

O

 

Jet cool(Power wind)

O

O

 

Swirl wind

O

O

 

Deodorizing filter

X

X

Air Purifier

Plasma air purifier

Option

Option

 

Prefilter(washable / anti-fungus)

O

O

 

Drain pump

O

O

Installation

E.S.P. control

-

-

Electric heater(operation)

X

X

 

 

High ceiling operation

O

O

 

Hot start

O

O

Reliability

Self diagnosis

O

O

 

Soft dry operation

O

O

 

Auto changeover

X

X

 

Auto cleaning

X

X

 

Auto operation(artificial intelligence)

O

O

 

Auto restart operation

O

O

 

Child lock

O

O

Convenience

Energy-Saving Cooling Mode

X

X

Forced operation

O

O

 

 

Group control

O

O

 

Sleep mode

O

O

 

Timer(on/off)

O

O

 

Timer(weekly)

O

O

 

Two thermistor control

O

O

 

Wide wired remote controller

Accessory (PQRCUSA0)

Accessory (PQRCUSA0)

 

Deluxe wired remote controller

-

-

Individual

Simple wired remote controller

X

X

Simple wired remote controller(for hotel use)

Accessory (PQRCFCS0C)

Accessory (PQRCFCS0C)

Control

Wireless remote controller(simple)

X

X

 

 

Wireless LCD remote control

X

X

 

Wireless LCD remote control(Ez)

O

O

 

General central controller (Non LGAP)

X

X

CAC

Dry contact

Accessory (PQDSB)

Accessory (PQDSB)

Central control(LGAP)

X

X

Network Function

PDI(power distribution indicator)

X

X

 

 

PI 485

X

X

Special

CTIE

X

X

Function Kit

Zone control

-

-

 

 

 

 

Others

Thermistor

-

-

 

 

 

 

Note :

O : Applied, X : Not applied, - : No relation

*Option : Model name & price are different according to options, and assembled in factory with main unit.

*Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.

Copyright ©2009 LG Electronics. Inc. All right reserved.

- 3 -

Only for training and service purposes

LGE Internal Use Only

 

Loading...
+ 6 hidden pages