LG AHNW166A0, AHUW166A0, AHUW126A0, AHUW146A0, AHNW146A0 Manual

4 (1)

LG

LG

Air-to-Water Heat Pump

Owner's Manual

Models : AH Series

Dear Owner

Thank you for installing LG Air-to-Water Heat Pump. Your best choice guarantees you a great performance and service to make your life comfortable & pleasant.

FRANÇAIS ENGLISH

IMPORTANT

Please read this owner's manual carefully and thoroughly before installing and operating your Air-to-Water Heat Pump.

Please retain this owner's manual for future reference after reading it thoroughly.

Air-to-Water Heat Pump Owner’s Manual

TABLE OF CONTENTS

A. Safety Precautions.........................

3

B. Product Introduction......................

6

C. Owner's instruction........................

8

D. Using Thermostat.........................

33

E. Maintenance and Service ............

37

F. Disposal Requirements................

39

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Installer's Name

Purchased Date

Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your AWHP properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your product.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

AWHP is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with AWHP.

When the power cable is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

Installation work must be performed in accordance

2 Air-to-Water Heat Pump Owner’s Manual

Safety Precaution

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage.

 

WARNING

Always ground the product.

There is a risk of electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself.

There is risk of fire or electric shock.

Use the correctly rated breaker or fuse.

There is risk of fire or electric shock.

Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age.

It may cause product to fall.

Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.

There is risk of fire or electric shock .

Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire.

There is risk of fire or electric shock.

Do not modify or extend the power cable. If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced.

There is risk of fire or electric shock.

Never install the outdoor unit on a moving base or a place from where it can fall down.

The falling outdoor unit can cause damage or injury or even death of a person.

Do not use a multi outlet. Always use this appliance on a dedicated circuit and breaker.

Otherwise it can cause electric shock or fire.

Install the panel and the cover of control box securely.

There is risk of fire or electric shock due to dust , water etc.

For installation, removal or reinstall , always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

When the product is soaked (flooded or submerged) in water , contact an Authorized Service Center for repair before using it again.

There is risk of fire or electric shock.

Be sure to check the refrigerant to be used. Please read the label on the product.

Incorrect refrigerant can prevent the normal operation of the unit.

Do not place a heater or other heating appliances near the power cable.

There is risk of fire and electric shock.

Don't use a power cord, a plug or a loose socket which is damaged.

Otherwise it may cause a fire or electrical shock.

Do not allow water to run into electric parts. Install the unit away from water sources.

There is risk of fire, failure of the product, or electric shock.

Do not touch , operate, or repair the product with wet hands.

There is risk of electric shock or fire.

Do not store or use or even allow flammable gas or combustibles near the product.

There is risk of fire.

ENGLISH

Owner’s Manual 3

Safety Precaution

Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.

Improper or loose connections can cause heat generation or fire.

In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work.

An charged capacitor can cause electrical shock.

Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or service and then tear away and throw away the plastic packaging bags.

Children may play with them and cause injury.

When installing the unit, use the installation kit provided with the product.

Make sure to check that the power device is not dirty, loose or broken and then Turn on the power.

Dirty, loose or broken power device can cause electric shock or fire.

Be sure to use only those parts which are listed in the service parts list. Never attempt to modify the equipment.

• Otherwise the unit may fall and cause severe

• The use of inappropriate parts can cause an

injury.

electrical shock, excessive heat generation

 

or fire.

Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.

Oxygen deficiency could occur and hence harm your health.

Ventilate the product room from time to time when operating it together with a stove, or heating element etc.

Oxygen deficiency can occur and hence harm your health.

Take care to ensure that power cable could not be pulled out or damaged during operation.

There is risk of fire or electric shock.

Do not open the front cover or grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product failure.

Turn the main power off when cleaning or repairing the product.

There is risk of electric shock.

Do not place ANYTHING on the power cable.

There is risk of fire or electric shock.

4 Air-to-Water Heat Pump Owner’s Manual

Safety Precaution

CAUTION

Two or more people must lift and transport the product.

Avoid personal injury.

Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product.

Always check for gas (refrigerant) leakage after installation or repair of product.

• It may cause a problem for your neighbors

• Low refrigerant levels may cause failure of

and hence dispute.

product.

Do not block the inlet or outlet of air flow.

It may cause product failure.

Do not insert hands or other objects through the air inlet or outlet while the product is operating.

There are sharp and moving parts that could cause personal injury.

Do not tilt the unit when removing or uninstalling it.

The condensed water inside can spill .

Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc .

There is risk of fire, electric shock, or damage to the plastic parts of the product.

Be cautious when unpacking and installing the product.

Sharp edges could cause injury.

Do not mix air or gas other than the specified refrigerant used in the system .

If air enters the refrigerant system, an excessively high pressure results, causing equipment damage or injury.

Keep level even when installing the product.

To avoid vibration or noise.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer AWHP, not a precision refrigeration system.

There is risk of damage or loss of property.

Do not step on or put anyting on the product. (outdoor units)

There is risk of personal injury and failure of product.

If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.

The refrigernat gas can cause frostbite (cold burn)

If the refrigerant gas leaks during the installation, ventilate the area immediately.

Otherwise it can be harmfull for your health.

Dismantling the unit, treatment of the

Do not expose your skin or kids or

Use a firm stool or ladder when cleaning,

refrigerant oil and eventual parts should

plants to the cool or hot air draft.

maintaining or repairing the product at

be done in accordance with local and

 

an height.

national standards.

 

 

 

• This could harm to your health.

• Be careful and avoid personal injury.

ENGLISH

Owner’s Manual 5

LG AHNW166A0, AHUW166A0, AHUW126A0, AHUW146A0, AHNW146A0 Manual

Product Introduction

Product Introduction

TypicalInstallationScene

1

3

 

 

2

Water

Water

Inlet

Outlet

4

 

5

Indoor unit

Outdoor unit

Refrigerant pipe and connecting cable

Water pipe

5. Ground wire to ground outdoor unit to prevent electrical shocks.

*The shape of products can be chaged according to the model capacity and type.

6 Air-to-Water Heat Pump Owner’s Manual

Control Panel

 

 

1

 

 

2

8

 

 

 

3

9

 

4

10

 

5

11

 

12

 

6

 

7

13

1.

Display panel

9. Function setting button

2.

Change temperature button

10. Temperature setting mode

3.

Silent mode On/Off button

button

 

4.

Operation mode selection button

11. Temperature view mode button

 

5.

Water heating Enable/Disable

12. Programming button

 

 

button

13. Set/Clear button

6.

ESC button

 

7.

Direction button

 

 

(Up, Down, Left, Right)

 

8.

Power button

 

Some functions may not be operated and displayed depending on the model.

Owner's instruction

Owner's instruction

MonitoringInformation

AUXILIARY SOLAR THERMAL PUMP

This icon indicates that auxiliary solar thermal pump is active.

NOTE : As installation of auxiliary solar thermal pump is not compulsory but recommendation according to field condition, this icon can be seen although no auxiliary solar thermal pump is installed.

Water Pump

This icon indicates that the water pump inside the indoor unit is active.

Sanitary Water Tank heater

This icon indicates that sanitary water tank electric heater which is located inside sanitary water tank is active.

The icon is not used when sanitary water tank is not installed.

Electric Heater STEP ONE

Electric Heater STEP TWO

These icons indicate that the backup electric heater which is located inside the indoor unit is operating.

8 Air-to-Water Heat Pump Owner’s Manual

Owner's instruction

MonitoringInformation

ENGLISH

NO FUNCTION

Child Lock

Outdoor

This icon indicates that the outdoor unit is active.

Disinfection

This icon indicates disinfecting operation is ongoing in sanitary water tank.

Maintain lowest temperature

The purpose of this mode is maintaining the temperature to prevent damage by freezing of water pipe.

Defrosting

This icon indicates that the defrost mode is active.

In space heating operation or sanitary water tank heating operation, freezing of the outdoor heat exchanger may be occured due to low outdoor temperature and humidity. If this risk occurs, the product goes into defrost operation. It reverses the cycle and takes heat from the indoor system to prevent freezing of the outdoor system. This mode is automatically operating.

Owner’s Manual 9

Owner's instruction

MonitoringInformation

Heavy trouble

This icon indicates that heavy trouble is occurred.

Slight trouble

This icon indicates that slight trouble is occurred.

Thermostat

This icon indicates connection with thermostat.

Central Controller

This icon indicates that the product is controlled by the central controller.

10 Air-to-Water Heat Pump Owner’s Manual

Owner's

Mode Change

Turn on the product and select operation mode.

1 Press Power Button to turn on product.

2 Press OPER MODE Button to each operation mode.

: Cooling operation

: Heating operation

: Weather dependent operation

Operation Mode

Cooling Operation - The product yields cool water to use in under floor cooling or FCU cooling.

Heating Operation - The product yields hot water to use in under floor heating or FCU heating.

Weather dependent Heating Operation - In this mode, heating setpoint is automatically determined

by pre-defined temperature profile. For more detail, please refer description on Function Code 24 and 25.

You can set the proper temperature each mode.

Note

: Decrease 1°C or 2°F per one time pressing

: Increase 1°C or 2°F per one time pressing

We can change the temperature range of each mode on installation setting mode. Please refer Function Code 11 to 15.

Room Temperature setting is available when Remote Room Air Sensor (sold separately) is installed. Please refer Function Code 03.

Loading...
+ 28 hidden pages