OPTIFLUX 6000
Warnings and symbols used
DANGER!
This information refers to the immediate danger when working with electricity.
DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.
SAFETY INSTRUCTIONS 1
HANDLING
• This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
iRESULT
RESULT
RESULTRESULT
This symbol refers to all important consequences of the previous actions.
Safety instructions for the operator
CAUTION!
Installation, assembly, start-up and maintenance may only be performed by appropriately
trained personnel. The regional occupational health and safety directives must always be
observed.
LEGAL NOTICE!
The responsibility as to the suitability and intended use of this device rests solely with the user.
The supplier assumes no responsibility in the event of improper use by the customer. Improper
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of
Sale" apply which form the basis of the purchase contract.
INFORMATION!
•
Further information can be found on the supplied CD-ROM in the manual, on the data sheet,
in special manuals, certificates and on the manufacturer's website.
•
If you need to return the device to the manufacturer or supplier, please fill out the form
contained on the CD-ROM and send it with the device. Unfortunately, the manufacturer
cannot repair or inspect the device without the completed form.
www.krohne.com07/2013 - 4002945701 - QS OPTIFLUX 6000 R05 en
3
2 INSTALLATION
2.1 Scope of delivery
INFORMATION!
Inspect the cartons carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
OPTIFLUX 6000
Figure 2-1: Scope of delivery
1 Ordered flowmeter
2 Product documentation
3 Factory calibration report
4 CD-ROM with product documentation
5 Grounding rings (optional)
6 Signal cable (remote version only)
4
www.krohne.com07/2013 - 4002945701 - QS OPTIFLUX 6000 R05 en
OPTIFLUX 6000
2.2 Device description
Your measuring device is supplied ready for operation. The factory settings for the operating
data have been made in accordance with your order specifications.
The following versions are available:
• Compact version (the signal converter is mounted directly on the measuring sensor)
• Remote version (electrical connection to the measuring sensor via field current and signal
cable)
INFORMATION!
This flow sensor can be used as a remote version or as a compact version. All versions are
covered by this document, allthough you will see the remote version in most pictures.
INSTALLATION 2
Figure 2-2: Available versions
1 Remote version
2 Compact version with IFC 300 signal converter
3 Compact version with IFC 100 (0°) signal converter
4 Compact version with IFC 100 (45°) signal converter
5 Compact version with IFC 050 (10°) signal converter
www.krohne.com07/2013 - 4002945701 - QS OPTIFLUX 6000 R05 en
5
2 INSTALLATION
2.3 Nameplates
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.
1 Name and address of the manufacturer
2 Type designation of the flowmeter and CE sign with number(s) of notified body / bodies
3 Calibration data
4 PED data
OPTIFLUX 6000
2.4 Storage
• Store the device in a dry and dust-free location.