GE AEH05, AEH08*, AES05 Owner’s Manual & Installation Instructions

0 (0)
<![if ! IE]>

<![endif]>Air Conditioners

<![if ! IE]>

<![endif]>Room

ge.com

Safety Instructions . . . . . . . . . . . . .2, 3

Operating Instructions

Control Knob Models . . . . . . . . . . .6, 7

Touch Pad Models . . . . . . . . . . . . . .4, 5

Care and Cleaning

Air Filter . . . . . . . . . . . . . . . . . . . . . . . .7

Outdoor Coils . . . . . . . . . . . . . . . . . . . .7

Installation Instructions . . . . . . .8–11

Troubleshooting Tips . . . . . . . . . . . .12

Normal Operating Sounds . . . . . . . .12

Consumer Support

Consumer Support . . . . . . .Back Cover Ownership Registration for

Customers in Canada only . . . . . .13, 14 Warranty for Customers

in Canada . . . . . . . . . . . . . . . . . . . . . .16 Warranty for Customers

in the U.S.A. . . . . . . . . . . . . . . . . . . . .15

*ENERGY STAR® labeled product

As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the side of the air conditioner.

In Canada, contact us at:

www.GEAppliances.ca

Owner’s Manual and

Installation Instructions

AEH05

AEH06*

AEH08*

AES05

Climatiseur

Manuel d’utilisation et instructions d’installation

La section française commence à la page 17

Acondicionador

de aire

Manual del propietario y instrucciones de instalación

La sección en español empieza en la página 33

49-7604 12-08 JR

<![if ! IE]>

<![endif]>Safety Instructions

<![if ! IE]>

<![endif]>Operating

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Care and Cleaning

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Consumer Support

<![if ! IE]>

<![endif]>Troubleshooting

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn the unit OFF and unplug your air conditioner before cleaning.

GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip

or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

ge.com

WARNING!

USE OF EXTENSION CORDS—115-Volt models only

Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord.

However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14-gauge, 3-wire grounding-type appliance extension cord having a grounding-type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.

CAUTION:

DO NOT use an extension cord with any of the 230/208 volt models.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

3

<![if ! IE]>

<![endif]>Instructions Safety

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Operating

 

<![if ! IE]>

<![endif]>Cleaning and Care

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Troubleshooting

<![if ! IE]>

<![endif]>Support Consumer

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Safety Instructions

 

 

<![if ! IE]>

<![endif]>Operating

<![if ! IE]>

<![endif]>Instructions

 

<![if ! IE]>

<![endif]>Care and Cleaning

 

 

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Consumer Support

<![if ! IE]>

<![endif]>Troubleshooting

About the controls on the air conditioner—models with touch pads.

Features and appearance will vary.

Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Light indicates the unit

is in the temperature or

The display always shows the room delay time Set mode. temperature except when setting the

Set temperature or the Delay timer.

Light indicates the delay timer is set.

Air Conditioner Controls

Delay 1–24hr

Delay timer

 

 

Delay

 

 

 

Decrease

M

 

 

 

ode

o

Mode select

 

Aut

 

 

 

 

 

-

F

 

n

an

 

a

 

+

Fan speed

F

 

Temp

 

 

Decrease

 

 

 

Temperature

 

 

Power

set Increase

 

 

 

and Decrease

 

 

 

Remote Control

Delay timer Increase

Auto Fan on/off

Fan speed Increase

Unit power on/off

Controls

Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Energy Saver modes. The Set light will turn on while setting.

NOTE: The display will change to show the room temperature after settings have been made. To recall the Set temperature, press the

Temp Increase or Decrease pads.

Temp Increase /Decrease Pads

Use to set temperature when in Cool or Energy Saver mode. The Set light will turn on while setting.

Delay Timer Increase (+) /Decrease (–)

Pads

Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control will set the delay time when using the Delay 1–24hr timer (). The Set light will turn on while setting.

Fan Speed Pads

Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease pads to set the fan speeds to Low, Med or High. Use the Auto pad to turn Auto fan on.

Mode Pad

Use to set the air conditioner to Cool, Energy Saver or Fan Only mode.

Delay Pads

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay 1–24hr pad on the unit or

thepad on the remote control. Each touch of the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control will set the timer in 1-hour intervals. The Set light will turn on while setting.

To review the remaining time on the Delay 1–24hr timer, press the Delay 1–24hr pad on the unit or thepad on the remote control. Use the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the remote control to set a new time if desired.

To cancel the timer, press the Delay 1–24hr pad until the light on the Delay 1–24hr pad goes off.

4

ge.com

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 20 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

Make sure batteries are fresh and installed correctly as indicated on the remote control.

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase / Decrease pads to set the desired temperature between 64°F and 86°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the Cool mode and

High or Med fan with a middle set temperature.

For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.

For Quieter and Nighttime Cooling—Select the

Cool mode and Low fan with a middle set temperature.

Energy Saver Mode

Controls the fan.

 

ON—The fan will cycle on and off with the

OFF—The fan runs all the time, while the

compressor. This results in wider variations of room

compressor cycles on and off.

temperature and humidity. Normally used when the

 

room is unoccupied. NOTE: The fan may continue to run

 

for a short time after the compressor cycles off.

 

 

 

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan

NOTE: Auto Fan Speed cannot be used when in the

speed to provide air circulation and filtering

Fan Only Mode.

without cooling. Since fan-only settings do not

 

provide cooling, a Set temperature cannot be

 

entered. The room temperature will appear

 

in the display.

 

 

 

Auto Fan Speed

Set to Auto fan speed for the fan speed to

NOTE: Auto Fan Speed cannot be used when in the

automatically set to the speed needed to provide

Fan Only Mode.

optimum comfort settings with the set temperature.

 

If the room needs more cooling, the fan speed

 

will automatically increase. If the room needs less

 

cooling, the fan speed will automatically decrease.

 

 

 

Power Outage Recovery Feature

In the case of a power outage or interruption, the

feature was set, it will resume countdown. You may

 

unit will automatically restart in the settings last

need to set a new time if desired.

5

 

 

used after the power is restored. If the Delay 1–24hr

<![if ! IE]>

<![endif]>Instructions Safety

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Operating

 

<![if ! IE]>

<![endif]>Cleaning and Care

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Troubleshooting

<![if ! IE]>

<![endif]>Support Consumer

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Safety Instructions

 

 

<![if ! IE]>

<![endif]>Operating

<![if ! IE]>

<![endif]>Instructions

 

<![if ! IE]>

<![endif]>Care and Cleaning

 

 

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Consumer Support

<![if ! IE]>

<![endif]>Troubleshooting

About the controls on the air conditioner—models with control knobs.

Features and appearance will vary.

MODE

OFF

Coolest

TEMP

High

 

High

 

7

1

Cool

Fan

Med

Low

6

2

Cool

Fan

 

 

Low

 

5

3

Cool

 

 

4

MODE CONTROL

TEMPERATURE CONTROL

Controls (on some models)

Mode Control

High Cool, Med Cool and Low Cool provide cooling with different fan speeds.

Fan settings provide air circulation and filtering without cooling.

NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least

3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint.

For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob.

For Quieter and Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint.

TEMP Control

The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

Controls (on some models)

MODE

OFF

High

High

ON

Fan

Cool

Med

Low

Cool

Fan

Low

 

Cool

 

ON/OFF Control

Turns air conditioner on and off.

NOTE: If the air conditioner is off and is then turned on while set in a Cool mode, it will take approximately 3 minutes for the compressor to start and cooling to begin.

6

ge.com

Additional important information.

Air Direction

Use the lever to adjust the air direction left and right only.

 

Appearance may vary.

Care and cleaning of the air conditioner.

Grille and Case

 

Turn the air conditioner off and remove the plug

To clean, use water and a mild detergent. Do not

from the wall outlet before cleaning.

use bleach or abrasives.

Air Filter

 

The air filter behind the front grille should be

 

checked and cleaned at least every 30 days or

 

more often if necessary.

 

To remove:

Push on one side of the filter edge and pull it out the other side.

Clean the filter with warm, soapy water. Rinse and

let the filter dry before replacing it. Do not clean Appearance may vary. the filter in a dishwasher.

CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Batteries in the Remote Control

1

2

3

Remove the battery cover by sliding it according to the arrow direction.

Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.

Reattach the cover by sliding it back into position.

NOTES:

Use 2 “AAA” (1.5 volt) alkaline batteries. Do not use rechargeable batteries.

Remove the batteries from the remote control if the system is not going to be used for a long time.

7

<![if ! IE]>

<![endif]>Instructions Safety

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Operating

<![if ! IE]>

<![endif]>Cleaning and Care

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Troubleshooting

<![if ! IE]>

<![endif]>Support Consumer

<![if ! IE]>

<![endif]>Tips

Installation

Air Conditioner

Instructions

 

Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: ge.com

In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these

instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

Some models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Some models require 230/208-volt AC, protected with a time-delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

TOOLS YOU WILL NEED

Phillips-head screwdriver

Flat-blade screwdriver

Pencil

Ruler or tape measure

Level

Scissors or knife

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or

if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

8

Installation Instructions

PARTS INCLUDED

 

 

Window

(Appearance may vary)

 

 

 

 

 

sash seal

Top mounting rail

 

 

 

 

Foam top

 

 

 

window gasket

 

 

 

 

 

Right

 

 

 

accordion

 

Left

 

panel

Air

 

 

accordion

 

 

conditioner

 

 

panel

 

 

 

 

 

 

 

Top mounting rail

 

 

 

seal strip

Type A (6)

Type B (3)

Type C (5)

Window locking

 

 

 

bracket (1)

 

9

 

 

Sill Vinyl frame
1/2″ higher
than vinyl frame (on some windows)

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard doublehung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

Follow the dimensions in the table and illustration for your model.

Models

A

B

 

 

 

AEH05, AES05

13″ min.

24 1/2″–38 1/8″

 

 

 

AEH06, AEH08

13 5/8″ min.

24 1/2″–38 1/8″

 

 

 

A

B

(With accordion panels)

2 STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the sill.

WOOD PIECES WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the vinyl frame.

Attach securely with nails or screws provided by the installer.

Wood

1/2″ higher

than storm window frame

Storm window frame

10

3ATTACH THE TOP MOUNTING RAIL SEAL STRIP

Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail, along the front edge.

Top mounting rail

Remove backing from seal strip

FRONT VIEW

Top mounting rail

 

 

 

 

 

 

 

 

 

 

 

 

Seal strip

4 PREPARE THE AIR CONDITIONER

AInstall the top mounting rail with 3 Type B screws from the outside of the case.

Top mounting rail

Bottom mounting rail

BSlide the left and right accordion panels into the top and bottom mounting rails.

Top right

Top left

Installation Instructions

4PREPARE THE AIR CONDITIONER (cont.)

CAttach the accordion panels to the case using 3 Type A screws on each side.

Top mounting rail

Accordion panel

Type A screws

BACK

Bottom mounting rail

5 PREPARE THE WINDOW

Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.

6INSTALL THE AIR CONDITIONER IN THE WINDOW

APlace the air conditioner on the sill with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail.

It should be level or slightly tilted to the outside. Use a level; about a 1/3 bubble will be the correct case slant to the outside.

or

or

 

Type C screws

BExtend the left and right accordion panels to the vertical window sashes and attach, through the holes in the panels, with 4 Type C screws, as appropriate.

7INSTALL SUPPORT BRACKET AND FOAM TOP WINDOW GASKET

A

CAUTION:

 

 

To prevent broken glass

Vinyl

 

or damage to windows,

 

 

on vinyl or other

 

 

similarly constructed

 

 

windows, attach the

 

 

support bracket to the

 

 

window side jam.

 

 

Attach the support

Wood

 

bracket with one

 

 

Type C screw.

 

BCut the foam top window gasket to the window width.

C Stuff the foam between the glass and the window to

prevent air and

insects from getting into the room.

NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

11

<![if ! IE]>

<![endif]>Safety Instructions

 

 

<![if ! IE]>

<![endif]>Operating

<![if ! IE]>

<![endif]>Instructions

 

<![if ! IE]>

<![endif]>Care and Cleaning

 

 

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Tips

<![if ! IE]>

<![endif]>Consumer Support

<![if ! IE]>

<![endif]>Troubleshooting

Troubleshooting Tips.

Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed

does not start

 

is unplugged.

completely into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure.

The unit will automatically restart in the settings last

 

 

 

used after the power is restored.

 

 

 

There is a protective time delay (approximately

 

 

 

3 minutes) to prevent tripping of the compressor

 

 

 

overload. For this reason, the unit may not start

 

 

 

normal cooling for 3 minutes after it is turned

 

 

 

back on.

 

 

 

 

 

 

The current interrupter

Press the RESET button located on the power cord plug.

 

 

device is tripped.

If the RESET button will not stay engaged, discontinue

 

 

 

use of the air conditioner and contact a qualified

 

 

 

service technician.

 

 

 

 

Air conditioner does

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

On models with touch pads: In the Cool mode, press the

 

 

not be set correctly.

Decrease pad.

 

 

 

• On models with control knobs, turn the temperature

 

 

 

knob to a higher number.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

See the Care and Cleaning section.

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on, you need

 

 

 

to allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace registers and cold air returns.

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

On models with control knobs, set the mode control at

freezing up

 

and stops the air conditioner

High Fan or High Cool with the Temp at 1 or 2.

 

 

from cooling the room.

• On models with touch pads, set the controls at High Fan

 

 

 

or High Cool and set the thermostat to a higher

 

 

 

temperature.

 

 

 

 

The remote control

 

The batteries are inserted

Check the position of the batteries. They should be

is not working

 

incorrectly.

inserted in the opposite (+) and (–) direction.

 

 

 

 

 

 

The batteries may be dead.

Replace the batteries.

 

 

 

 

Water drips outside

 

Hot, humid weather.

This is normal.

 

 

 

 

Water drips indoors

 

The air conditioner is not

For proper water disposal, make sure the air conditioner

 

 

tilted to the outside.

slants slightly from the case front to the rear.

 

 

 

 

Water collects in

 

Moisture removed from air

This is normal for a short period in areas with little

base pan

 

and drains into base pan.

humidity; normal for a longer period in very humid areas.

 

 

 

 

 

 

 

 

Normal Operating Sounds

 

You may hear a pinging noise caused by water

Water will collect in the base pan during

 

being picked up and thrown against the

high humidity or on rainy days. The water

 

condenser on rainy days or when the humidity

may overflow and drip from the outdoor side

 

is high. This design feature helps remove

of the unit.

 

moisture and improve efficiency.

The fan may run even when the compressor

 

 

12

You may hear the thermostat click when the

does not.

compressor cycles on and off.

 

Please place in envelope and mail to:

Veuillez mettre dans une enveloppe et envoyez à :

OWNERSHIP REGISTRATION

P.O. BOX 1780

MISSISSAUGA, ONTARIO

L4Y 4G1

(FOR CANADIAN CONSUMERS ONLY)

13

GE AEH05, AEH08*, AES05 Owner’s Manual & Installation Instructions

14

GE Air Conditioner—One-Year Limited Warranty. (For customers in the U.S.A.)

Staple your receipt here.

Proof of the original purchase date is needed to make a warranty claim.

For The Period Of:

We Will Replace:

One Year

Replacement unit for any product which fails due to a defect in materials or workmanship.

From the date of the

The replacement unit is warranted for the remainder of your product’s original one-year

original purchase

warranty period.

In Order to Make a Warranty Claim:

Properly pack your unit. We recommend using the

Include in the package a copy of the sales receipt or other

original carton and packing materials.

evidence of date of original purchase. Also print your

Return the product to the retail location where it

name and address and a description of the defect.

 

was purchased.

 

What Is Not Covered:

Customer instruction. This owner’s manual provides information regarding operating instructions and user controls.

Improper installation, delivery or maintenance. If you have an installation problem, or if the air conditioner is of improper cooling capacity, contact your dealer or installer. You are responsible for providing adequate electrical, plumbing and other connecting facilities.

Failure of the product resulting from modifications to the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance.

Replacement of house fuses or resetting of circuit breakers.

Failure due to corrosion on models not corrosionprotected.

Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.

Incidental or consequential damage caused by possible defects with this air conditioner.

Damage caused after delivery.

EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product replacement as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Exclusion of implied warranties: Except where prohibited or restricted by law, there are no warranties, whether express, oral or statutory which extend beyond the description on the face hereof, including specifically the implied warranties of merchantability or fitness for a particular purpose.

Warrantor: General Electric Company. Louisville, KY 40225

15

<![if ! IE]>

<![endif]>Instructions Safety

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Operating

 

<![if ! IE]>

<![endif]>Cleaning and Care

 

 

<![if ! IE]>

<![endif]>Instructions

<![if ! IE]>

<![endif]>Installation

<![if ! IE]>

<![endif]>Troubleshooting

<![if ! IE]>

<![endif]>Support Consumer

<![if ! IE]>

<![endif]>Tips

Loading...
+ 33 hidden pages