GE AC Servo Motor αis, AC Servo Motor αi, AC Spindle Motor αi, AC Servo Amplifier αi Maintenance Manual

0 (0)

GE Fanuc Automation

Computer Numerical Control Products

AC Servo Motor αis Series

AC Servo Motor αi Series

AC Spindle Motor αi Series

AC Servo Amplifier αi Series

Maintenance Manual

GFZ-65285EN/03

March 2003

GFL-001

Warnings, Cautions, and Notes as Used in this Publication

Warning

Warning notices are used in this publication to emphasize that hazardous voltages, currents, temperatures, or other conditions that could cause personal injury exist in this equipment or may be associated with its use.

In situations where inattention could cause either personal injury or damage to equipment, a Warning notice is used.

Caution

Caution notices are used where equipment might be damaged if care is not taken.

Note

Notes merely call attention to information that is especially significant to understanding and operating the equipment.

This document is based on information available at the time of its publication. While efforts have been made to be accurate, the information contained herein does not purport to cover all details or variations in hardware or software, nor to provide for every possible contingency in connection with installation, operation, or maintenance. Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.

GE Fanuc Automation makes no representation or warranty, expressed, implied, or statutory with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or usefulness of the information contained herein. No warranties of merchantability or fitness for purpose shall apply.

©Copyright 2003 GE Fanuc Automation North America, Inc.

All Rights Reserved.

B-65285EN/03

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

The "Safety Precautions" section describes the safety precautions relating to the use of FANUC servo motors, spindle motors, and servo amplifiers (power supply modules, servo amplifier modules, and spindle amplifier modules). Users of any servo motor or amplifier model are requested to read the "Safety Precautions" carefully before using the servo motor or amplifier.

The users are also requested to read an applicable specification manual carefully and understand each function of the motor or amplifier for correct use.

The users are basically forbidden to do any behavior or action not mentioned in the "Safety Precautions." They are invited to ask FANUC previously about what behavior or action is prohibited.

 

Contents

 

1.1 DEFINITION OF WARNING, CAUTION, AND NOTE

.........s-2

1.2 FANUC AC SERVO MOTOR αis/αi series

 

FANUC AC SPINDLE MOTOR αi series................................

s-3

1.2.1Warning

...........................................................................

s-3

1.2.2Caution

...........................................................................

s-6

1.2.3Note

...........................................................................

s-7

1.3 FANUC SERVO AMPLIFIER αi series ...................................

s-9

1.3.1Warnings and Cautions Relating to Mounting ..................

s-9

1.3.1.1

Warning.............................................................

s-9

1.3.1.2

Caution ............................................................

s -11

1.3.1.3

Note .................................................................

s-13

1.3.2Warnings and Cautions Relating to a Pilot Run..............

s-14

1.3.2.1

Warning...........................................................

s -14

1.3.2.2

Caution ............................................................

s -15

1.3.3Warnings and Cautions Relating to Maintenance ...........

s -16

1.3.3.1

Warning...........................................................

s -16

1.3.4.2

Caution ............................................................

s -18

1.3.4.3

Note .................................................................

s-19

s-1

GE AC Servo Motor αis, AC Servo Motor αi, AC Spindle Motor αi, AC Servo Amplifier αi Maintenance Manual

SAFETY PRECAUTIONS

B-65285EN/03

1.1 DEFINITION OF WARNING, CAUTION, AND NOTE

This manual includes safety precautions for protecting the user and preventing damage to the machine. Precautions are classified into Warning and Caution according to their bearing on safety. Also, supplementary information is described as a Note. Read the Warning, Caution, and Note thoroughly before attempting to use the machine.

WARNING

Applied when there is a danger of the user being injured or when there is a damage of both the user being injured and the equipment being damaged if the approved procedure is not observed.

CAUTION

Applied when there is a danger of the equipment being damaged, if the approved procedure is not observed.

NOTE

The Note is used to indicate supplementary information other than Warning and Caution.

* Read this manual carefully, and store it in a safe place.

s-2

B-65285EN/03

SAFETY PRECAUTIONS

1.2 FANUC AC SERVO MOTOR αis/αi series FANUC AC SPINDLE MOTOR αi series

1.2.1 Warning

WARNING

-Be safely dressed when handling a motor.

Wear safety shoes or gloves when handling a motor as you may get hurt on any edge or protrusion on it or electric shocks.

-Use a crane or lift to move a motor from one place to another.

A motor is heavy. If you lift the motor by hand, you may get a backache, or you may be seriously injured when you drop the motor. A suitable crane or lift must be used to move the motor. (For the weight of motors, refer to their respective specification manuals.)

When moving a motor using a crane or lift, use a hanging bolt if the motor has a corresponding tapped hole, or textile rope if it has no tapped hole.

If a motor is attached with a machine or any other heavy stuff, do not use a hanging bolt to move the motor as the hanging bolt and/or motor may get broken.

-Before starting to connect a motor to electric wires, make sure they are isolated from an electric power source.

A failure to observe this caution is vary dangerous because you may get electric shocks.

-Be sure to secure power wires.

If operation is performed with a terminal loose, the terminal block may become abnormally hot, possibly causing a fire. Also, the terminal may become disconnected, causing a ground fault or short-circuit, and possibly giving you electric shocks. See the section in this manual that gives the tightening torque for attaching power wires and short-bars to the terminal block.

-Be sure to ground a motor frame.

To avoid electric shocks, be sure to connect the grounding terminal in the terminal box to the grounding terminal of the machine.

-Do not ground a motor power wire terminal or short-circuit it to another power wire terminal.

A failure to observe this caution may cause electric shocks or a burned wiring.

(*)Some motors require a special connection such as a winding changeover. Refer to their respective motor specification manuals for details.

s-3

SAFETY PRECAUTIONS

B-65285EN/03

WARNING

-Do not supply the power to the motor while any terminal is exposed.

A failure to observe this caution is very dangerous because you may get electric shocks if your body or any conductive stuff touches an exposed terminal.

-Do not bring any dangerous stuff near a motor.

Motors are connected to a power line, and may get hot. If a flammable is placed near a motor, it may be ignited, catch fire, or explode.

-Do not get close to a rotary section of a motor when it is rotating.

You may get your clothes or fingers caught in a rotary section, and may be injured. Before starting a motor, ensure that there is no stuff that can fly away (such as a key) on the motor.

-Do not touch a motor with a wet hand.

A failure to observe this caution is vary dangerous because you may get electric shocks.

-Before touching a motor, shut off the power to it.

Even if a motor is not rotating, there may be a voltage across the terminals of the motor.

Especially before touching a power supply connection, take sufficient precautions.

Otherwise you may get electric shocks.

-Do not touch any terminal of a motor for a while (at least 5 minutes) after the power to the motor is shut off.

High voltage remains across power line terminals of a motor for a while after the power to the motor is shut off. So, do not touch any terminal or connect it to any other equipment. Otherwise, you may get electric shocks or the motor and/or equipment may get damaged.

-To drive a motor, use a specified amplifier and parameters.

Driving a motor with other than the specified combinations of an amplifier and parameters may cause the motor to perform an unexpected operation; for example, the motor may get out of control, or produce excessively high torque. This may result in the motor or machine being damaged. Also, an object such as a workpiece or tool may fly off due to excessive rotation, possibly causing injury.

s-4

B-65285EN/03

SAFETY PRECAUTIONS

-Do not touch a regenerative discharge unit for a while (at least 30 minutes) after the power to the motor is shut off.

A regenerative discharge unit may get hot when the motor is running.

Do not touch the regenerative discharge unit before it gets cool enough. Otherwise, you may get burned.

-Do not touch a motor when it is running or immediately after it stops.

A motor may get hot when it is running. Do not touch the motor before it gets cool enough. Otherwise, you may get burned.

-Ensure that motors and related components are mounted securely.

If a motor or its component slips out of place or comes off when the motor is running, it is very dangerous.

-Be careful not get your hair or cloths caught in a fan.

Be careful especially for a fan used to generate an inward air flow. Be careful also for a fan even when the motor is stopped, because it continues to rotate while the amplifier is turned on.

-When designing and assembling a machine tool, make it compliant with EN60204-1.

To ensure the safety of the machine tool and satisfy European standards, when designing and assembling a machine tool, make it compliant with EN60204-1. For details of the machine tool, refer to its specification manual.

s-5

SAFETY PRECAUTIONS

B-65285EN/03

1.2.2 Caution

CAUTION

-FANUC motors are designed for use with machines. Do not use them for any other purpose.

If a FANUC motor is used for an unintended purpose, it may cause an unexpected symptom or trouble. If you want to use a motor for an unintended purpose, previously consult with FANUC.

-Ensure that a base or frame on which a motor is mounted is strong enough.

Motors are heavy. If a base or frame on which a motor is mounted is not strong enough, it is impossible to achieve the required precision.

-Be sure to connect motor cables correctly.

An incorrect connection of a cable cause abnormal heat generation, equipment malfunction, or failure. Always use a cable with an appropriate current carrying capacity (or thickness). For how to connect cables to motors, refer to their respective specification manuals.

-Ensure that motors are cooled if they are those that require forcible cooling.

If a motor that requires forcible cooling is not cooled normally, it may cause a failure or trouble. For a fan-cooled motor, ensure that it is not clogged or blocked with dust and dirt. For a liquid-cooled motor, ensure that the amount of the liquid is appropriate and that the liquid piping is not clogged.

For both types, perform regular cleaning and inspection.

-When attaching a component having inertia, such as a pulley, to a motor, ensure that any imbalance between the motor and component is minimized.

If there is a large imbalance, the motor may vibrates abnormally, resulting in the motor being broken.

-Be sure to attach a key to a motor with a keyed shaft.

If a motor with a keyed shaft runs with no key attached, it may impair torque transmission or cause imbalance, resulting in the motor being broken.

s-6

B-65285EN/03

SAFETY PRECAUTIONS

1.2.3 Note

NOTE

-Do not step or sit on a motor.

If you step or sit on a motor, it may get deformed or broken. Do not put a motor on another unless they are in packages.

-When storing a motor, put it in a dry (non-condensing) place at room temperature (0 to 40°C).

If a motor is stored in a humid or hot place, its components may get damaged or deteriorated. In addition, keep a motor in such a position that its shaft is held horizontal and its terminal box is at the top.

-Do not remove a nameplate from a motor.

If a nameplate comes off, be careful not to lose it. If the nameplate is lost, the motor becomes unidentifiable, resulting in maintenance becoming impossible.

For a nameplate for a built-in spindle motor, keep the nameplate with the spindle.

-Do not apply shocks to a motor or cause scratches to it.

If a motor is subjected to shocks or is scratched, its components may be adversely affected, resulting in normal operation being impaired. Be very careful when handling plastic portions, sensors, and windings, because they are very liable to break. Especially, avoid lifting a motor by pulling its plastic portion, winding, or power cable.

-Do not conduct dielectric strength or insulation test for a sensor.

Such a test can damage elements in the sensor.

-When testing the winding or insulation resistance of a motor, satisfy the conditions stipulated in IEC60034.

Testing a motor under a condition severer than those specified in IEC34 may damage the motor.

-Do not disassemble a motor.

Disassembling a motor may cause a failure or trouble in it.

If disassembly is in need because of maintenance or repair, please contact a service representative of FANUC.

-Do not modify a motor.

Do not modify a motor unless directed by FANUC. Modifying a motor may cause a failure or trouble in it.

s-7

SAFETY PRECAUTIONS

B-65285EN/03

NOTE

-Use a motor under an appropriate environmental condition.

Using a motor in an adverse environment may cause a failure or trouble in it.

Refer to their respective specification manuals for details of the operating and environmental conditions for motors.

-Do not apply a commercial power source voltage directly to a motor.

Applying a commercial power source voltage directly to a motor may result in its windings being burned. Be sure to use a specified amplifier for supplying voltage to the motor.

-For a motor with a terminal box, make a conduit hole for the terminal box in a specified position.

When making a conduit hole, be careful not to break or damage unspecified portions.

Refer to an applicable specification manual.

-Before using a motor, measure its winding and insulation resistances, and make sure they are normal.

Especially for a motor that has been stored for a prolonged period of time, conduct these checks. A motor may deteriorate depending on the condition under which it is stored or the time during which it is stored. For the winding resistances of motors, refer to their respective specification manuals, or ask FANUC. For insulation resistances, see the following table.

-To use a motor as long as possible, perform periodic maintenance and inspection for it, and check its winding and insulation resistances.

Note that extremely severe inspections (such as dielectric strength tests) of a motor may damage its windings. For the winding resistances of motors, refer to their respective specification manuals, or ask FANUC. For insulation resistances, see the following table.

MOTOR INSULATION RESISTANCE MEASUREMENT

Measure an insulation resistance between each winding and motor frame using an insulation resistance meter (500 VDC). Judge the measurements according to the following table.

Insulation resistance

Judgment

100MΩ or higher

Acceptable

10 to 100 MΩ

The winding has begun deteriorating. There is no

 

problem with the performance at present. Be sure

 

to perform periodic inspection.

1 to 10 MΩ

The winding has considerably deteriorated.

 

Special care is in need. Be sure to perform

 

periodic inspection.

Lower than 1 MΩ

Unacceptable. Replace the motor.

s-8

B-65285EN/03

SAFETY PRECAUTIONS

1.3 FANUC SERVO AMPLIFIER αi series

1.3.1 Warnings and Cautions Relating to Mounting

1.3.1.1Warning

WARNING

-Check the specification code of the amplifier.

Check that the delivered amplifier is as originally ordered.

-Mount a ground fault interrupter.

To guard against fire and electric shock, fit the factory power supply or machine with a ground fault interrupter (designed for use with an inverter).

-Securely ground the amplifier.

Securely connect the ground terminal and metal frame of the amplifier and motor to a common ground plate of the power magnetics cabinet.

-Be aware of the weight of the amplifier and other components.

Control motor amplifiers and AC reactors are heavy. When transporting them or mounting them in the cabinet, therefore, be careful not to injured yourself or damage the equipment. Be particularly carefull not to jam your fingers between the cabinet and amplifier.

-Never ground or short-circuit either the power supply lines or power lines.

Protect the lines from any stress such as bending. Handle the ends appropriately.

-Ensure that the power supply lines, power lines, and signal lines are securely connected.

A loose screw, loose connection, or the like will cause a motor malfunction or overheating, or a ground fault.

Be extremely careful with power supply lines, motor power lines, and DC link connections through which a large amount of current passes, because a loose screw (or poor contact in a connector or poor connection between a connector terminal and a cable) may cause a fire.

-Insulate all exposed parts that are charged.

s-9

SAFETY PRECAUTIONS

B-65285EN/03

WARNING

-Never touch the regenerative discharge resistor or radiator directly.

The surface of the radiator and regenerative discharge unit become extremely hot. Never touch them directly. An appropriate structure should also be considered.

-Close the amplifier cover after completing the wiring.

Leaving the cover open presents a danger of electric shock.

-Do not disassemble the amplifier.

-Ensure that the cables used for the power supply lines and power lines are of the appropriate diameter and temperature ratings.

-Do not apply an excessively large force to plastic parts.

If a plastic section breaks, it may cause internal damage, thus interfering with normal operation. The edge of a broken section is likely to be sharp and, therefore, presents a risk of injury.

s-10

B-65285EN/03

SAFETY PRECAUTIONS

1.3.1.2Caution

CAUTION

-Do not step or sit on the amplifier.

Also, do not stack unpacked amplifiers on top of each other.

-Use the amplifier in an appropriate environment.

See the allowable ambient temperatures and other requirements, given in the corresponding descriptions.

-Protect the amplifier from corrosive or conductive mist or drops of water.

Use a filter if necessary.

-Protect the amplifier from impact.

Do not place anything on the amplifier.

-Connect the power supply lines and power lines to the appropriate terminals and connectors.

-Connect the signal lines to the appropriate connectors.

-Do not block the air inlet to the radiator.

A deposit of coolant, oil mist, or chips on the air inlet will result in a reduction in the cooling efficiency. In some cases, the required efficiency cannot be achieved. The deposit may also lead to a reduction in the useful life of the semiconductors. Especially, when outside air is drawn in, mount filters on both the air inlet and outlet. These filters must be replaced regularly.

So, an easy-to-replace type of filter should be used.

-Before connecting the power supply wiring, check the supply voltage.

Check that the supply voltage is within the range specified in this manual, then connect the power supply lines.

-Ensure that the combination of motor and amplifier is appropriate.

-Ensure that valid parameters are specified.

Specifying an invalid parameter for the combination of motor and amplifier may not only prevent normal operation of the motor but also result in damage to the amplifier.

-Ensure that the amplifier and peripheral equipment are securely connected.

Check that the magnetic contactor, circuit breaker, and other devices mounted outside the amplifier are securely connected to each other and that those devices are securely connected to the amplifier.

s-11

SAFETY PRECAUTIONS

B-65285EN/03

CAUTION

-Check that the amplifier is securely mounted in the power magnetics cabinet.

If any clearance is left between the power magnetics cabinet and the surface on which the amplifier is mounted, dust entering the gap may build up and prevent the normal operation of the amplifier.

-Apply appropriate countermeasures against noise.

Adequate countermeasures against noise are required to maintain normal operation of the amplifier. For example, signal lines must be routed away from power supply lines and power lines.

s-12

B-65285EN/03

SAFETY PRECAUTIONS

1.3.1.3Note

NOTE

-Keep the nameplate clearly visible.

-Keep the legend on the nameplate clearly visible.

-After unpacking the amplifier, carefully check for any damage.

-Mount the amplifier in a location where it can be easily accessed periodic inspection and daily maintenance.

-Leave sufficient space around the machine to enable maintenance to be performed easily.

Do not place any heavy objects such that they would interfere with the opening of the doors.

-Keep the parameter table and spare parts at hand.

Also, keep the specifications at hand. These items must be stored in a location where they can be retrieved immediately.

-Provide adequate shielding.

A cable to be shielded must be securely connected to the ground plate, using a cable clamp or the like.

s-13

SAFETY PRECAUTIONS

B-65285EN/03

1.3.2 Warnings and Cautions Relating to a Pilot Run

1.3.2.1Warning

WARNING

-Before turning on the power, check that the cables connected to the power magnetics cabinet and amplifier, as well as the power lines and power supply lines, are securely connected. Also, check that no lines are slack.

A loose screw, loose connection, or the like will cause a motor malfunction or overheating, or a ground fault. Be extremely careful with power supply lines, motor power lines, and DC link connections through which a large amount of current passes, because a loose screw (or poor contact in a connector or poor connection between a connector terminal and a cable) may cause a fire.

-Before turning on the power, ensure that the power magnetics cabinet is securely grounded.

-Before turning on the power, check that the door of the power magnetics cabinet and all other doors are closed.

Ensure that the door of the power magnetics cabinet containing the amplifier, and all other doors, are securely closed. During operation, all doors must be closed and locked.

-Apply extreme caution if the door of the power magnetics cabinet or another door must be opened.

Only a person trained in the maintenance of the corresponding machine or equipment should open the door, and only after shutting off the power supply to the power magnetics cabinet (by opening both the input circuit breaker of the power magnetics cabinet and the factory switch used to supply power to the cabinet). If the machine must be operated with the door open to enable adjustment or for some other purpose, the operator must keep his or her hands and tools well away from any dangerous voltages. Such work must be done only by a person trained in the maintenance of the machine or equipment.

-When operating the machine for the first time, check that the machine operates as instructed.

To check whether the machine operates as instructed, first specify a small value for the motor, then increase the value gradually. If the motor operates abnormally, perform an emergency stop immediately.

-After turning on the power, check the operation of the emergency stop circuit.

Press the emergency stop button to check that the motor stops immediately, and that the power being supplied to the amplifier is shut off by the magnetic contactor.

s-14

B-65285EN/03

SAFETY PRECAUTIONS

-Before opening a door or protective cover of a machine to enable adjustment of the machine, first place the machine in the emergency stop state and check that the motor has stopped.

s-15

SAFETY PRECAUTIONS

B-65285EN/03

1.3.2.2Caution

CAUTION

-Note whether an alarm status relative to the amplifier is displayed at power-up or during operation.

If an alarm is displayed, take appropriate action as explained in the maintenance manual. If the work to be done requires that the door of the power magnetics cabinet be left open, the work must be carried out by a person trained in the maintenance of the machine or equipment. Note that if some alarms are forcibly reset to enable operation to continue, the amplifier may be damaged. Take appropriate action according to the contents of the alarm.

-Before operating the motor for the first time, mount and adjust the position and speed sensors.

Following the instructions given in the maintenance manual, adjust the position and speed sensors for the spindle so that an appropriate waveform is obtained.

If the sensors are not properly adjusted, the motor may not rotate normally or the spindle may fail to stop as desired.

-If the motor makes any abnormal noise or vibration while operating, stop it immediately.

Note that if operation is continued in spite of there being some abnormal noise or vibration, the amplifier may be damaged. Take appropriate corrective action, then resume operation.

-Observe the ambient temperature and output rating requirements.

The continuous output rating or continuous operation period of some amplifiers may fall as the ambient temperature increases. If the amplifier is used continuously with an excessive load applied, the amplifier may be damaged.

-Unless otherwise specified, do not insert or remove any connector while the power is turned on. Otherwise, the amplifier may fail.

s-16

B-65285EN/03

SAFETY PRECAUTIONS

1.3.3 Warnings and Cautions Relating to Maintenance

1.3.3.1Warning

WARNING

-Read the maintenance manual carefully and ensure that you are totally familiar with its contents.

The maintenance manual describes daily maintenance and the procedures to be followed in the event of an alarm being issued. The operator must be familiar with these descriptions.

-Notes on replacing a fuse or PC board

1)Before starting the replacement work, ensure that the circuit breaker protecting the power magnetics cabinet is open.

2)Check that the red LED that indicates that charging is in progress is not lit.

The position of the charging LED on each model of amplifier is given in this manual. While the LED is lit, hazardous voltages are present inside the unit, and thus there is a danger of electric shock.

3)Some PC board components become extremely hot. Be careful not to touch these components.

4)Ensure that a fuse having an appropriate rating is used.

5)Check the specification code of a PC board to be replaced. If a modification drawing number is indicated, contact FANUC before replacing the PC board.

Also, before and after replacing a PC board, check its pin settings.

6)After replacing the fuse, ensure that the screws are firmly tightened. For a socket-type fuse, ensure that the fuse is inserted correctly.

7)After replacing the PC board, ensure that it is securely connected.

8)Ensure that all power lines, power supply lines, and connectors are securely connected.

-Take care not to lose any screws.

When removing the case or PC board, take care not to lose any screws. If a screw is lost inside the nit and the power is turned on, the machine may be damaged.

s-17

SAFETY PRECAUTIONS

B-65285EN/03

WARNING

-Notes on replacing the battery of the absolute pulse coder

Replace the battery only while the power is on. If the battery is replaced while the power is turned off, the stored absolute positioning data will be lost. Some series servo amplifier modules have batteries in their servo amplifiers. To replace the battery of any of those models, observe the following procedure: Open the door of the power magnetics cabinet; Leave the control power of the power supply module on; Place the machine in the emergency stop state so that the power being input to the amplifier is shut off; Then, replace the battery. Replacement work should be done only by a person who is trained in the related maintenance and safety requirements. The power magnetics cabinet in which the servo amplifier is mounted has a high-voltage section. This section presents a severe risk of electric shock.

-Check the number of any alarm.

If the machine stops upon an alarm being issued, check the alarm number. Some alarms indicate that a component must be replaced. If the power is reconnected without first replacing the failed component, another component may be damaged, making it difficult to locate the original cause of the alarm.

-Before resetting an alarm, ensure that the original cause of the alarm has been removed.

-Contact FANUC whenever a question relating to maintenance arises.

-Notes on removing the amplifier

Before removing the amplifier, first ensure that the power is shut off. Be careful not to jam your fingers between the power magnetics cabinet and amplifier.

s-18

B-65285EN/03

SAFETY PRECAUTIONS

1.3.3.2Caution

CAUTION

-Ensure that all required components are mounted.

When replacing a component or PC board, check that all components, including the snubber capacitor, are correctly mounted. If the snubber capacitor is not mounted, for example, the IPM will be damaged.

-Tighten all screws firmly.

-Check the specification code of the fuse, PC board, and other components.

When replacing a fuse or PC board, first check the specification code of the fuse or PC board, then mount it in the correct position. The machine will not operate normally if a fuse or PC board having other than the correct specification code is mounted, or if a fuse or PC board is mounted in the wrong position.

-Mount the correct cover.

The cover on the front of the amplifier carries a label indicating a specification code. When mounting a previously removed front cover, take care to mount it on the unit from which it was removed.

-Notes on cleaning the heat sink and fan

1)A dirty heat sink or fan results in reduced semiconductor cooling efficiency, which degrades reliability. Periodic cleaning is necessary.

2)Using compressed air for cleaning scatters the dust. A deposit of conductive dust on the amplifier or peripheral equipment will result in a failure.

3)To clean the heat sink, do so only after turning the power off and ensuring that the heat sink has cooled to room temperature. The heat sink becomes extremely hot, such that touching it during operation or immediately after power-off is likely to cause a burn. Be extremely careful when touching the heat sink.

s-19

SAFETY PRECAUTIONS

B-65285EN/03

1.3.3.3Note

NOTE

-Ensure that the battery connector is correctly inserted.

If the power is shut off while the battery connector is not connected correctly, the absolute position data for the machine will be lost.

-Store the manuals in a safe place.

The manuals should be stored in a location where they can be accessed immediately it so required during maintenance work.

-Notes on contacting FANUC

Inform FANUC of the details of an alarm and the specification code of the amplifier so that any components required for maintenance can be quickly secured, and any other necessary action can be taken without delay.

s-20

B-65285EN/03

PREFACE

PREFACE

Organization of this manual

Series 15i

Series 16i, 18i, 21i, 0i, PMi

This manual describes information necessary to maintain FANUC servo amplifier αi series products, such as a power supply module, servo amplifier module, and spindle amplifier module and FANUC servo motor αis/αi series and FANUC spindle motor αi series products.

Part I explains the start-up procedure, and part II focuses on troubleshooting.

Part III explains the maintenance for servo motor and spindle motor.

The abbreviations listed below are used in this manual.

Product name

Abbreviations

FANUC Series 15i

FS15i

FANUC Series 16i

FS16i

FANUC Series 18i

FS18i

FANUC Series 21i

FS21i

FANUC Series 0i

FS0i

FANUC Power Mate i-D

PMi

FANUC Power Mate i-H

 

Power Supply Module

PSM

Servo Amplifier Module

SVM

Spindle Amplifier Module

SPM

*In this manual, the parameter numbers of servo parameters are sometimes indicated without CNC product names as follows:

Servo parameter function name or bit

No. 1877 (FS15i)

 

Overload protection coefficient (OVC1)

No. 2062 (FS16i)

 

 

*The manuals shown below provide information related to this manual. This manual may refer you to these manuals.

FANUC SERVO AMPLIFIER αi series Descriptions B-65282EN FANUC AC SERVO MOTOR αis/αi series Descriptions B-65262EN FANUC AC SPINDLE MOTOR αi series Descriptions B-65272EN FANUC AC SERVO MOTOR αis/αi series Parameter Manual

B-65270EN FANUC AC SPINDLE MOTOR αi series Parameter Manual

B-65280EN

p-1

B-65285EN/03

TABLE OF CONTENTS

TABLE OF CONTENTS

SAFETY PRECAUTIONS..........................................................................

s-1

PREFACE

..................................................................................................

 

p-1

I. START-UP PROCEDURE

 

1

OVERVIEW ............................................................................................

 

3

2

CONFIGURATIONS ...............................................................................

4

 

2.1 ......................................................................................

CONFIGURATIONS

5

 

2.2 ................................................................................

MAJOR COMPONENTS

7

 

............................................................................................

2.2.1

Power Supply Modules

7

 

........................................................................................

2.2.2

Servo Amplifier Modules

8

 

.....................................................................................

2.2.3

Spindle Amplifier Modules

9

3

START ....................................................................-UP PROCEDURE

11

 

3.1 ....................................................

START - UP PROCEDURE (OVERVIEW)

12

 

3.2 ......................................................................

CONNECTING THE POWER

13

 

.................................................

3.2.1 Checking the Voltage and Capacity of the Power

13

 

............................................................................

3.2.2 Connecting a Protective Ground

14

 

.........

3.2.3 Selecting the Ground Fault Interrupter That Matches the Leakage Current

14

 

3.3 ........................................................

INITIALIZING SERVO PARAMETERS

15

4 CONFIRMATION ..............................................OF THE OPERATION

16

 

4.1 ........................................................................

POWER SUPPLY MODULE

17

 

.....................................................................................

4.1.1 Checking the Status LEDs

18

 

.......................................................

4.1.2 Check Terminal on the Printed - circuit Board

19

 

...........................................................

4.1.3 The PIL LED (Power ON Indicator) Is Off

21

 

........................

4.1.4 Checking Method when Magnetic Contactor Is not Switched On

22

 

4.2 ....................................................................

SERVO AMPLIFIER MODULE

23

 

............................................................................

4.2.1 Checking the STATUS Display

24

 

................................................

4.2.2 VRDY - OFF Alarm Indicated on the CNC Screen

25

 

...................................................................

4.2.3 Method for Observing Motor Current

26

 

4.3 .................................................................

SPINDLE AMPLIFIER MODULE

29

 

...................................................................................................

4.3.1

STATUS Display

30

 

....................................................................................

4.3.2

Troubleshooting at Startup

31

 

...........................................................

 

4.3.2.1 The PIL LED (power-on indicator) is off

31

 

.......................................................

 

4.3.2.2 The STATUS display is blinking with "--."

32

c-1

TABLE OF CONTENTS

 

B-65285EN/03

 

 

4.3.2.3 The motor does not turn . ....................................................................................

33

 

 

4.3.2.4 A specified speed cannot be obtained . ...............................................................

33

 

 

4.3.2.5 When cutting is not performed, the spindle vibrates, making noise . ..................

34

 

 

4.3.2.6 An overshoot or hunting occurs . ........................................................................

34

 

 

4.3.2.7 Cutting power weakens or acceleration/deceleration slows down ......................

35

 

4.3.3 Status Error Indication Function ...........................................................................

36

 

4.3.4 Checking the Feedback Signal Waveform ............................................................

39

 

 

Mi, MZi, and BZi sensors ..................................................................................

40

 

 

α position coder S ..............................................................................................

41

 

4.3.5

Spindle Check Board .............................................................................................

42

 

 

4.3.5.1 Spindle check board specifications ....................................................................

42

 

 

Check board connection.....................................................................................

42

 

 

4.3.5.3 Check terminal output signals ............................................................................

44

 

4.3.6 Observing Data Using the Spindle Check Board ..................................................

46

 

 

Overview............................................................................................................

46

 

 

Major characteristics ..........................................................................................

46

 

 

Observation method ...........................................................................................

46

 

 

4.3.6.4 Specifying data to be monitored .........................................................................

47

 

 

4.3.6.5 Address descriptions and initial values (SPM) ...................................................

48

 

 

4.3.6.6 Principles in outputting the internal data of the serial spindle ............................

49

 

 

Data numbers .....................................................................................................

53

 

 

4.3.6.8 Example of observing data .................................................................................

56

 

4.3.7 Checking Parameters Using the Spindle Check Board..........................................

57

 

 

Overview............................................................................................................

57

 

 

Checking parameters ..........................................................................................

57

 

4.3.8 Observing Data Using the SERVO GUIDE ..........................................................

58

 

 

Overview............................................................................................................

58

 

 

4.3.8.2 Usable series and editions ..................................................................................

58

 

 

4.3.8.3 List of spindle data that can be observed using the SERVO GUIDE .................

58

 

 

4.3.8.4 About the spindle control and spindle status signals ..........................................

59

 

 

4.3.8.5 Example of observing data .................................................................................

60

5 PERIODIC MAINTENANCE OF SERVO AMPLIFIER..........................

61

5.1

BATTERY FOR THE ABSOLUTE PULSECODER......................................

62

5.2

PERIODIC MAINTENANCE OF SERVO AMPLIFIER .................................

69

II. TROUBLESHOOTING

 

1 OVERVIEW

 

75

2 ALARM NUMBERS ..............................AND BRIEF DESCRIPTIONS

76

2.1

FOR Series ............................................................................................15i

 

77

 

2.1.1 ...........................................................................................................

Servo Alarm

77

c-2

B-65285EN/03

 

 

TABLE OF CONTENTS

 

2.1.2

Spindle Alarm........................................................................................................

79

2.2

FOR Series 16i, 18i, 20i, 21i, 0i, AND Power Mate i...................................

81

 

2.2.1

Servo Alarm...........................................................................................................

81

 

2.2.2

Spindle Alarm........................................................................................................

83

3 TROUBLESHOOTING AND ACTION ..................................................

85

3.1

POWER SUPPLY MODULE (PSM, PSMR) ................................................

86

 

3.1.1

Alarm Code 1 (PSM).............................................................................................

86

 

3.1.2

Alarm Code 2 (PSM, PSMR) ................................................................................

87

 

3.1.3

Alarm Code 3 (PSM).............................................................................................

87

 

3.1.4

Alarm Code 4 (PSM, PSMR) ................................................................................

87

 

3.1.5

Alarm Code 5 (PSM, PSMR) ................................................................................

88

 

3.1.6

Alarm Code 6 (PSM, PSMR) ................................................................................

88

 

3.1.7

Alarm Code 7 (PSM, PSMR) ................................................................................

88

 

3.1.8

Alarm Code 8 (PSMR) ..........................................................................................

89

 

3.1.9

Alarm Code A (PSM) ............................................................................................

89

 

3.1.10

Alarm Code E (PSM, PSMR)................................................................................

89

 

3.1.11

Alarm Code H (PSMR) .........................................................................................

90

3.2

SERVO AMPLIFIER MODULE ....................................................................

91

 

3.2.1

Alarm Code 1.........................................................................................................

93

 

3.2.2

Alarm Code 2.........................................................................................................

93

 

3.2.3

Alarm Code 5.........................................................................................................

93

 

3.2.4

Alarm Code 6.........................................................................................................

94

 

3.2.5

Alarm Code F ........................................................................................................

94

 

3.2.6

Alarm Code P ........................................................................................................

94

 

3.2.7

Alarm Code 8.........................................................................................................

95

 

3.2.8

Alarm Codes 8., 9., and A. ....................................................................................

96

 

3.2.9

Alarm Codes 8., 9., and A. ....................................................................................

96

 

3.2.10

Alarm Codes b, c, and d ........................................................................................

97

 

3.2.11

Alarm Code "-" Blinking .......................................................................................

98

 

3.2.12

Alarm Code U........................................................................................................

99

 

3.2.13

Alarm Code L ......................................................................................................

100

3.3

SERVO SOFTWARE.................................................................................

101

 

3.3.1

Servo Adjustment Screen ....................................................................................

101

 

3.3.2

Diagnosis Screen .................................................................................................

103

 

3.3.3

Overload Alarm (Soft Thermal, OVC)................................................................

104

 

3.3.4

Feedback Disconnected Alarm............................................................................

105

 

3.3.5

Overheat Alarm ...................................................................................................

106

 

 

c-3

 

TABLE OF CONTENTS

B-65285EN/03

 

3.3.6

Invalid Servo Parameter Setting Alarm...............................................................

106

 

3.3.7

Alarms Related to Pulsecoder and Separate Serial Detector...............................

107

 

3.3.8

Other Alarms .......................................................................................................

110

3.4

SPINDLE AMPLIFIER MODULE ...............................................................

112

 

3.4.1

Alarm Code 01.....................................................................................................

112

 

3.4.2

Alarm Code 02.....................................................................................................

113

 

3.4.3

Alarm Code 03.....................................................................................................

114

 

3.4.4

Alarm Code 06.....................................................................................................

114

 

3.4.5

Alarm Code 07.....................................................................................................

115

 

3.4.6

Alarm Code 09.....................................................................................................

116

 

3.4.7

Alarm Code 12.....................................................................................................

117

 

3.4.8

Alarm Code 15.....................................................................................................

118

 

3.4.9

Alarm Code 18.....................................................................................................

118

 

3.4.10

Alarm Codes 19 and 20 .......................................................................................

118

 

3.4.11

Alarm Code 21.....................................................................................................

119

 

3.4.12

Alarm Code 24.....................................................................................................

119

 

3.4.13

Alarm Code 27.....................................................................................................

120

 

3.4.14

Alarm Code 29.....................................................................................................

121

 

3.4.15

Alarm Code 31.....................................................................................................

122

 

3.4.16

Alarm Code 32.....................................................................................................

122

 

3.4.17

Alarm Code 34.....................................................................................................

122

 

3.4.18

Alarm Code 36.....................................................................................................

123

 

3.4.19

Alarm Code 37.....................................................................................................

123

 

3.4.20

Alarm Code 41.....................................................................................................

124

 

3.4.21

Alarm Code 42.....................................................................................................

124

 

3.4.22

Alarm Code 46.....................................................................................................

124

 

3.4.23

Alarm Code 47.....................................................................................................

125

 

3.4.24

Alarm Code 50.....................................................................................................

125

 

3.4.25

Alarm Codes 52 and 53 .......................................................................................

126

 

3.4.26

Alarm Code 54.....................................................................................................

126

 

3.4.27

Alarm Code 55.....................................................................................................

126

 

3.4.28

Alarm Code 56.....................................................................................................

126

 

3.4.29

Alarm Code 66.....................................................................................................

127

 

3.4.30

Alarm Code 69.....................................................................................................

127

 

3.4.31

Alarm Code 70.....................................................................................................

127

 

3.4.32

Alarm Code 71.....................................................................................................

127

 

3.4.33

Alarm Code 72.....................................................................................................

127

 

 

c-4

 

B-65285EN/03

 

 

TABLE OF CONTENTS

 

3.4.34

Alarm Code 73.....................................................................................................

128

 

3.4.35

Alarm Code 74.....................................................................................................

128

 

3.4.36

Alarm Code 75.....................................................................................................

128

 

3.4.37

Alarm Code 76.....................................................................................................

129

 

3.4.38

Alarm Code 77.....................................................................................................

129

 

3.4.39

Alarm Code 78.....................................................................................................

129

 

3.4.40

Alarm Code 79.....................................................................................................

129

 

3.4.41

Alarm Code 81.....................................................................................................

130

 

3.4.42

Alarm Code 82.....................................................................................................

131

 

3.4.43

Alarm Code 83.....................................................................................................

131

 

3.4.44

Alarm Code 84.....................................................................................................

132

 

3.4.45

Alarm Code 85.....................................................................................................

132

 

3.4.46

Alarm Code 86.....................................................................................................

132

 

3.4.47

Alarm Code 87.....................................................................................................

132

 

3.4.48

Alarm Code 88.....................................................................................................

132

 

3.4.49

Alarm Codes A, A1, and A2................................................................................

132

 

3.4.50

Alarm Code b0.....................................................................................................

133

 

3.4.51

Alarm Codes C0,C1, and C2 ...............................................................................

133

 

3.4.52

Alarm Code C3....................................................................................................

133

 

3.4.53

Other Alarms .......................................................................................................

134

3.5

αCi SERIES SPINDLE AMPLIFIER MODULE ..........................................

135

 

3.5.1

Alarm Code 12.....................................................................................................

135

 

3.5.2

Alarm Code 35.....................................................................................................

136

4 HOW TO REPLACE THE FUSES AND PRINTED CIRCUIT

 

BOARDS ............................................................................................

 

 

137

4.1

HOW TO REPLACE THE FUSES AND PRINTED CIRCUIT BOARDS ....

138

 

4.1.1

Ordering Number of Printed Circuit Board.........................................................

139

 

4.1.2

Fuse Locations.....................................................................................................

140

 

 

4.1.2.1

PSM ..............................................................................................................

140

 

 

4.1.2.2

SVM ..............................................................................................................

141

 

 

4.1.2.3

SPM ..............................................................................................................

142

4.2

HOW TO REPLACE THE FAN MOTOR....................................................

143

4.2.1Internal-Fan Motor Replacement Procedure Common to 60, 90, and 150 mm

 

Wide Units...........................................................................................................

143

4.2.2

External-Fan Motor Replacement Procedure for 60 and 90 mm Wide Units .....

144

4.2.3

External-Fan Motor Replacement Procedure for 150 mm Wide Unit.................

145

4.2.4

External-Fan Motor Replacement Procedure for 300 mm Wide Unit.................

146

 

c-5

 

TABLE OF CONTENTS B-65285EN/03

III. MOTOR MAINTENANCE

 

1 SERVO MOTOR MAINTENANCE......................................................

149

1.1

RECEIVING AND KEEPING AC SERVO MOTORS .................................

150

1.2

DAILY INSPECTION OF AC SERVO MOTORS .......................................

151

1.3

PERIODIC INSPECTION OF AC SERVO MOTORS ................................

153

1.4

REPLACING THE PULSECODER ............................................................

156

1.5

SPECIFICATION NUMBERS OF REPLACEMENT PARTS......................

158

2 SPINDLE MOTOR MAINTENANCE...................................................

159

2.1

PREVENTIVE MAINTENANCE .................................................................

160

2.2

MAINTENANCE PARTS............................................................................

163

2.3

ALLOWABLE RADIAL LOAD ....................................................................

167

c-6

Loading...
+ 176 hidden pages