GE AEY05LVW2, AEY05LVW1, AEY05LVL1, AET05LXW1, AET05LXQ1 Owner’s Manual

...
0 (0)

GEAppliances.com

Air Conditioners

Room

. . . . . .Safety Instructions

. . . . . .

. 2, 3

 

Owner’s Manual and

Recycle Information

 

3

 

. . . . . . .

 

Installation Instructions

 

 

 

 

Operating Instructions

 

 

 

 

 

 

 

 

AET05

Controls . . . . . . . . . . . . . . . . . . . .

. . . . . . .

4–6

 

Care and Cleaning

 

 

 

AEY05

 

 

 

 

 

Air Filter . . . . . . . . . . . . . . . . . . . .

. . . . . . .

. . . 7

 

 

 

Outdoor Coils . . . . . . . . . . . . . . .

. . . . . . .

. . . 7

 

 

 

Installation Instructions. . . . . .

8-11

 

 

 

Acondicionador

Troubleshooting Tips . . .

. . . . . . .

. .12

Normal Operating Sounds . . .

. . . . . . .

. .12

 

de aire

Consumer Support

 

 

 

Consumer Support . . . . . . . . . .

Back Cover

 

 

 

 

Manual del propietario

Warranty . . . . . . . . . . . . . . . . . . .

. . . . . . .

. .13

 

 

 

 

 

y instrucciones de

 

 

 

 

instalación

La sección en español empieza en la página 14

Write the model and serial numbers here:

Model # _________________________

Serial # __________________________

Find these numbers on a label on the side of the air conditioner.

49-7741 11-14 GE

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Replace immediately all electric service

cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length

or at either the plug or connector end.

Turn the unit OFF and unplug your air conditioner before cleaning.

GE does not support any servicing of the air conditioner. We strongly recommend that you do not attempt to service the air conditioner yourself.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity

of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

These R410A air conditioning systems require contractors and technicians to

use tools, equipment and safety standards approved for use with this refrigerant.

DO NOT use equipment certified for R22 refrigerant only.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded

3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

GEAppliances.com

WARNING!

USE OF EXTENSION CORDS

RISK OF FIRE. Could cause serious injury or death.

DO NOT use an extension cord with this Window Air Conditioner.

DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

RECYCLING INFORMATION

For appliance recycling information please visit www. geappliances.com/recycling.

3

GE AEY05LVW2, AEY05LVW1, AEY05LVL1, AET05LXW1, AET05LXQ1 Owner’s Manual

About the controls on the air conditioner.

Features and appearance will vary.

MODE CONTROL

TEMPERATURE CONTROL

Controls

Mode Control

High Cool and Low Cool provide cooling with different fan speeds.

Fan settings provide air circulation and filtering without cooling.

NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least

3 minutes before switching back to a cool setting.

Cooling Descriptions

)RU 1RUPDO &RROLQJ³Select High Cool or Low Cool with the TEMPERATURE control at midpoint.

For Maximum Cooling³6HOHFW High Cool with the TEMPERATURE control at the highest number available on your knob.

For Quieter and Nighttime Cooling³6HOHFW Low Cool with the TEMPERATURE control at midpoint.

TEMP Control

The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer.

4

GEAppliances.com

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Air Direction

Use the lever to adjust the air direction left and right only.

5

Loading...