PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°

CONTROL SETTING

Type A with Run / Start Capacitor

65°F (18°C) Ambient

 

 

90°F (32°C) Ambient

 

 

 

 

 

 

 

 

 

 

Operating Time

 

90 to 100%

 

 

100%

 

 

 

 

 

 

 

 

 

 

Freezer Temperature

 

-5° to 2°F

 

 

 

-1° to 3°F

 

(-20° to -17°C)

 

 

 

(-18° to -16°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerator Temperature

34° to 39°F

 

 

 

34° to 39°F

(1° to 4°C)

 

 

 

(1° to 4°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Side Pressure

 

-2 to 6 psig

 

 

 

-2 to 6 psig

 

(-14 to 41 kPa)

 

 

 

(-14 to 41 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Side Pressure

 

85 to 105 psig

 

 

 

120 to 135 psig

(last 1/3 cycle)

 

(586 to 724 kPa)

 

 

 

(827 to 931 kPa)

 

 

 

 

 

 

 

 

 

Wattage (last 1/3 cycle)

30 to 50

 

 

 

50 to 70

 

 

 

 

 

 

 

 

 

 

 

Amps (running)

 

 

.4 to .8

 

 

 

.7 to .9

 

 

 

 

 

 

 

 

 

 

Base Voltage

 

115 vac (127 vac max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEFROST SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal Cutout

 

Heater

Defrost Thermistor

 

 

 

 

 

 

 

 

 

 

Termination

Cabinet Size:

 

 

 

 

 

 

 

 

 

 

 

 

Cut-in

 

Cut-out

 

Watts

 

Ohms

Cut-out

 

 

 

 

 

 

 

 

 

 

 

27’ & 28’ SD,

 

Freezer

110°F

 

135°F

 

500

 

26.5

48°F

22’ CD

 

 

(43.3°C)

 

(57.2°C)

 

 

 

 

(8°C)

 

 

Fresh Food

110°F

 

135°F

 

70

 

188.9

68°F

 

 

Ice Maker

(43.3°C)

 

(57.2°C)

 

 

 

 

(20°C)

 

 

 

 

 

 

 

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER FAN MOTOR

 

 

 

 

 

 

 

 

 

 

Watts

 

RPM

 

 

 

Amps

 

 

 

 

 

 

 

 

 

3.1

 

1100 CW

 

 

 

0.03 Running

 

Opposite Shaft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FREEZER ICE MAKER SPECIFICATIONS

 

 

 

 

 

 

 

 

Electrical

 

115 vac (127 vac max)

 

 

 

 

 

 

 

 

Thermostat

 

Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)

 

 

 

 

 

 

 

 

 

 

 

Heater Voltage

 

115 vac

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE

 

 

POWER

 

 

 

 

 

NEUTRAL

 

 

 

ICE MAKER

 

 

 

 

 

 

 

 

BLK

 

BRN

 

 

 

 

 

 

.LT

 

 

 

 

 

 

 

MAKER ICE

BLUE

P-3

THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CUT-OUT

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

BLK

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOLD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICE MAKER

 

 

SWITCH NO

 

LT. BLUE

 

 

P-4

 

 

 

RED

 

THERMOSTAT

 

 

WATER

 

 

NC

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

NO

RED

 

 

 

 

 

 

 

 

 

BLK

 

 

BLU

 

 

 

 

 

 

 

 

NC

 

VALVE

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

MOLD HEATER

 

 

 

SHUTOFF

 

 

 

 

165 WATTS

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

GRN / YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

YELLOW

 

P-1

 

 

 

 

C

 

 

 

 

 

 

 

 

 

P-2

 

 

MOLD

MOUNTING

 

WATER FILL

 

 

 

 

 

 

 

 

 

 

 

 

PLATE

 

SWITCH

 

 

 

 

 

 

 

ICE MAKER

 

 

 

 

 

 

 

CAUTION

Allelectricalpartsandwiringmustbeshieldedfromtorchflame.DONOTallowtorchtotouchinsulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.

FREEZER ICE MAKER INFORMATION

(Where Applicable)

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle.

Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.

Water Fill

Adjustment

Motor

Gear

T

U

R

N Mounting

Plate

Screws

Mounting

Plate

Screw

Timing

Gear

SERVICE DATA SHEET

A06589001

ICE & WATER - AUTOMATIC DEFROST

BOTTOM FREEZER - R134a

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

 

ERROR CODES

 

 

SPECIAL MODES

 

 

 

 

 

 

 

 

 

Display

Interpretation

Mode

Display

Activate

Deactivate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FZ

FF

 

 

FZ

FF

(press for up to 10 sec. simultaneously)

 

 

 

 

 

 

 

 

--

OP

Open FF

Manual Defrost

d

F

+ and -

Same to deactivate

 

 

Cavity Thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

OP

--

Open FZ

Demo / Showroom

77

77

^ and -

Unplug to deactivate

 

 

Cavity Thermistor

 

 

 

 

 

--

SH

Shorted FF

Sabbath

Sb

Sb

v and +

Same to deactivate

 

 

Cavity Thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

SH

--

Shorted FZ

System Diagnostic

No FF or FZ display,

^ and v

Press and hold +

 

 

Cavity Thermistor

 

all UI LEDs on

 

to deactivate

SY

CF

UI to Main Board

Current Air Temps

FZ Temp

FF Temp

v and + and

Automatically

 

 

communication

 

 

 

Water

after 10 sec

 

 

failure; on start up

 

 

 

 

 

 

 

 

 

 

 

 

 

SY

CE

UI to Main Board

FFIM Diagnostic

Numerical display of

^ and +

Press and hold +

 

 

communication

 

first test

 

to deactivate

 

 

error; after a period

 

 

 

 

 

 

 

in operation

 

 

 

 

 

 

 

 

 

 

 

 

 

SY

EF

Freezer Evaporator

Notes:

 

 

 

 

 

 

Fan Failure

•Always check for pin back-outs, pinched or damaged wires before replacing components.

 

 

 

•Determine whether failure is caused by the component, main control board or wiring.

dl

SP

Ice Chute Door is

Contact TID before replacing main control board.

 

 

 

open; check for

 

 

 

•Refer to Service Manual for additional information.

 

 

 

obstruction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRESH FOOD ICE MAKER DIAGNOSTIC MODE

Activate: Press ^ and + temperature pads for up to 10 sec. simultaneously.

Press + or - to move forward or backward through tests.

Deactivate: Press + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.

NOTE: Silence alarm.

 

Test

To activate test

Passing Result

 

 

 

 

52C

Ice Maker Thermistor

Activates

FZ display shows temperature sensed by Ice Maker Thermistor.

 

 

automatically

“OP” if open; “SH” if short

 

 

 

 

55C

Water Valve

Press set

Remove ice tray to collect water into a measuring container to measure water

 

 

 

fill. If collecting water into ice tray, first perform test 63C to empty ice tray.

57C

Evaporator Fan (FFIM)

Press set

“On” on FZ display when fan activated, “OFF” when deactivated.

 

 

 

 

 

Ice Level Sensor

Activates

Remove ice bucket.

 

 

automatically

Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.

58C

 

 

Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.

 

 

 

This test runs continuously until another test is selected.

 

 

 

 

63C

Twist Tray

Press set

Remove ice bucket.

 

 

 

FZ display shows “1” and “GOOD”.

 

 

 

 

FRESH FOOD ICE MAKER FILL TIME ADJUSTMENT MODE

NOTE: First consider water filter condition before adjusting fill time.

Activate: Press and hold the Water and Crush pads for up to 10 seconds.

Press + or - to adjust between the 3 fill settings.

Deactivate: Exits automatically after 10 seconds, or press any button other than + or -.

 

Display

Description

 

 

 

FZ

 

FF

 

 

 

 

 

 

 

 

Min Fill Time (default)

 

 

 

 

IC

 

=

Mid Fill Time

 

 

 

 

 

 

=

Max Fill Time

 

 

 

 

 

 

SYSTEM DIAGNOSTIC MODE

Activate:

Press ^ and v for up to 10 sec. simultaneously. Press + to advance through tests.

Deactivate:

Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.

 

 

Note: Silence alarm.

 

• Tests marked with “*” may

not be applicable to this unit and will not be displayed in System Diagnostic Mode.

• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.

• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.

• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.

 

Test

To activate test:

Passing result

--

First Screen

--

All LEDs on UI illuminated, except digit displays.

--

Second Screen

--

All segments of UI digit displays illuminated.

--

Third Screen

--

Blank UI display, no LEDs illuminated.

28

Dispenser Paddle

Press disp. paddle

“On” on UI when depressed; “off” when released

46

Humidity Sensor

Activates automatically

“OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater

 

 

 

System: “HI” - heater should be on. “Lo” - heater should be off. %RH is

 

 

 

displayed when humidity is between “Lo” and “HI” values; heater could

 

 

 

be on or off.

47

Dispenser Pocket Heater

Press set

Heater on when “on’ off when “off”.

2

Freezer

Press set

Freezer defrost heater on when “on”; off when “off”. Evaporator thermis-

 

Defrost Heater

 

tor temperature is flashed. Watch for temp increase with the heater on. It

 

 

 

may take a few minutes for the evaporator to heat up.

8

Water Valve

Press set

FF door must be closed. Be prepared to collect water at dispenser.

 

(Dispenser)

 

Water dispenses when “on”; stops when “off”

10

Auger Motor

Press set

FF door must be closed. Motor running when “on”; motor stopped when “off”

11

Cube/Crush Solenoid

Press set

FF door must be closed. Do not leave solenoid in activated state.

 

 

 

Solenoid activated when “on”; deactivated when “off”.

12

Condenser Fan

Press set

Fan running when “on”; stopped when “off”

43

Mullion Anticonden-

Press set

Flip mullion heater on when “on”; off when “off”

 

sation Heater

 

 

38

VCC Compressor

Press set

Compressor running when “on”; off when “off”

13

FF Lights

Press set

FF lights on when “on”; off when “off”

15

Freezer

Press set

Press to toggle between “off”, “LO” and “HI”. A current sensor reading is

 

Evaporator Fan

 

flashed (units are not mA). OFF reading should be around 2. “LO” speed

 

 

 

reading should settle down to around 9. “HI” speed reading should settle

 

 

 

down above 40.

20

FZ Lights

Press set

FZ lights on when “on”, off when “off”

22

Damper

Press set

Perform test 15 and set fan to “HI”. Then check for air flow when open

 

 

 

“OP”; and no air leaks when closed “CL”

36

Ice Chute Door

Depress ice chute door

“OP” on UI when manually opened; “CL” when closed . Or using “power

 

 

or press set

on-off”, motor drive door open “OP” or closed “CL”

23

FF Door

Open/Close FF door

“CL” on UI when door closed; “OP” when open

24

FZ Door

Open/Close FZ door

“CL” on UI when door closed; “OP” when open

26

Ice Maker

Activates automatically

Heater is turned on automatically. The ice maker evaporator thermistor

 

Defrost Heater

 

temperature is flashed. Watch for temp increase with the heater on. It

 

 

 

may take a few minutes for the evaporator to heat up.

29

FF Thermistor

Activates automatically

UI shows temperature sensed by FF thermistor; pass if within 10°F of tempera-

 

 

 

ture measured with gauge at FF thermistor location. “OP” if open; “SH” if short

30

FZ Thermistor

Activates automatically

UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature

 

 

 

measured with gauge at FZ thermistor location.“OP” if open; “SH” if short

33

Ambient Thermistor

Activates automatically

UI shows temperature sensed at main board; pass if within +20°F/-10°F of tem-

 

@ Main Board

 

perature measured with gauge at main board location. “OP” if open; “SH” if short

34

Ambient Thermistor

Activates automatically

UI shows temperature sensed at UI; Pass if within +20˚F/-10˚F of tem-

 

@ UI

 

perature measure with gauge at UI location. “OP” if open; “SH” if short.

39

Freezer Evaporator

Activates automatically

UI shows temperature sensed by freezer evaporator thermistor; pass if

 

Thermistor

 

within 10°F of temperature measured with gauge at evaporator thermistor

 

 

 

location.“OP” if open; “SH” if short

45

Ice Maker Mold

Activates automatically

UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of tem-

 

Thermistor

 

perature measured with gauge at ice maker mold. “OP” if open; “SH” if short

68

Ice Maker

Activates automatically

UI shows temperature sensed by evaporator thermistor; pass if within

 

Evaporator Thermistor

 

10°F of temperature measured with gauge at evaporator thermistor loca-

 

 

 

tion. “OP¯” if open; “SH¯” if short

0-

Firmware

Press set

Displays digit sequence; record

 

Parameters

 

 

1-

Main Board

Press set

Displays digit sequence; record

 

Firmware

 

 

3-

UI Firmware

Press set

Displays digit sequence; record

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

VCC COMPRESSOR MOTOR RESISTANCE CHECK

Check resistance between terminals 1 and 2, 2 and 3, 3 and 1.

If all resistances are equal, compressor is operative.

Loading...