UNVENTED (VENT-FREE) GAS
COMPACT CLASSIC HEARTH® FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL
Shown with optional cabinet mantel/hearth base accessory.
REMOTE-READY MODELS:
VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRA
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
—Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
—WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
—Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 6 of this manual.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
TABLE OF CONTENTS
Safety Information ............................................... |
3 |
Cleaning and Maintenance |
............................... |
26 |
Product Identification .......................................... |
4 |
Wiring Diagram ................................................. |
|
27 |
Optional Remote Control Accessories ................ |
5 |
Troubleshooting ................................................ |
|
28 |
Local Codes ........................................................ |
5 |
Specifications .................................................... |
|
32 |
Product Features ................................................ |
5 |
Replacement Parts ........................................... |
|
33 |
Unpacking ........................................................... |
5 |
Service Hints ..................................................... |
|
33 |
Assembly ............................................................ |
5 |
Technical Service .............................................. |
|
33 |
Air For Combustion and Ventilation .................... |
6 |
Illustrated Parts Breakdown .......and Parts List |
34 |
|
Installation ........................................................... |
9 |
Accessories ....................................................... |
|
36 |
Operating Fireplace .......................................... |
22 |
Warranty Information .......................... |
Back Cover |
|
Inspecting Burners ............................................ |
25 |
|
|
|
2 |
www.desatech.com |
113110-01A |
SAFETY INFORMATION
WARNING:Thisproductcontains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/ LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
WARNING: Any change to this fireplace or its controls can be dangerous.
WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approvedforusewiththisfireplace.
WARNING: Do not allow fans toblowdirectlyintothefireplace. Avoidanydraftsthatalterburner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Fireplace front and screen become very hot when running heater. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carefully supervise young children when they are in the room with fireplace. When using the hand-held remote accessory keep selector switch in the OFF positiontopreventchildrenfrom turning on burners with remote.
You must operate this fireplace withthefireplacescreeninplace. Make sure fireplace screen is closed before running fireplace.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
113110-01A |
www.desatech.com |
3 |
SAFETY INFORMATION
Continued
1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3.If you smell gas
•shut off gas supply
•do not try to light any appliance
•do not touch any electrical switch; do not use any phone in your building
•immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
•if you cannot reach your gas supplier, call the fire department
4.This fireplace shall not be installed in a bathroom or bedroom.
5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.
6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.
7.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.
8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 26.
9.Before using furniture polish, wax, carpet cleaner, or similar products, turn fireplace off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
10.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 6 through 8. If fireplace keeps shutting off, see Troubleshooting, pages 28 through 31.
11.Do not run fireplace
•where flammable liquids or vapors are used or stored.
•under dusty conditions.
12.Do not use this fireplace to cook food or burn paper or other objects.
13.Never place any objects in the fireplace or on logs.
14.Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water.
15.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.
17.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).
18.Topreventperformanceproblems,donotusepropane/LP fuel tank of less than 100 lbs. capacity.
19.Provide adequate clearances around air openings.
PRODUCT
IDENTIFICATION
Fireplace |
Screen |
Cabinet |
|
Logs
Selector
Switch Remote
(Optional) Ignitor Control Control
Button Knob
(Optional)
Figure 1 - Vent-Free Compact Classic
Hearth® Fireplace
4 |
www.desatech.com |
113110-01A |
OPTIONAL REMOTE CONTROL ACCESSORIES
There are four optional remote controls that can be purchased separately:
•wall switch
•hand-held ON/OFF remote
•wall thermostat
•hand-held thermostat remote See Accessories, pages 36 and 37.
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
SAFETY PILOT
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.
UNPACKING
1.Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time.
2.Remove all protective packaging applied to fireplace for shipment.
3.Make sure your fireplace includes one hardware packet.
4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.
ASSEMBLY
WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive temperatures on fireplace surfaces.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury.
ASSEMBLING FIREPLACE
Tools Required:
•Phillips screwdriver
•5/16" hex wrench
•slotted screwdriver
•scissors
1.Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove. Set screen aside until installation has been completed.
2.Cut two plastic straps to remove the log from the firebox cavity.
3.An optional blower is available. See Accessories, pages 36 and 37. Install optional blower now. Follow installation instructions provided with blower or (see page 14).
Shoulder
Screw
Burner Support
With Log
Locator Tabs
Screen
Branch
Support
Figure 2 - Removing Screen
113110-01A |
www.desatech.com |
5 |
ASSEMBLY |
AIR FOR COMBUSTION |
Continued |
AND VENTILATION |
4.Locate four black phillips sheet metal screws from the hardware packet.
5.Rotate hood as shown in Figure 3. Make sure hood tabs point toward fireplace.
6.Insert hood tabs between baffle and louvers (see Figure 3).
7.Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 3).
8.Align screw holes on hood with screw holes on firebox top.
9.Insert screws as shown in Figure 3. Tighten screws firmly.
Hood Tabs
Hood Louver
Hood Tab
Baffle
Sheet Metal
Screws
Firebox Top
Figure 3 - Assembling Hood
WARNING: This fireplace shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
6 |
www.desatech.com |
113110-01A |
AIR FOR COMBUSTION AND VENTILATION
Continued
Unusually tight construction is defined as construction where:
a.walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and
b.weather stripping has been added on openable windows and doors and
c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of these three criteria, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the three criteria above,proceed to Determining FreshAir Flow For Fireplace Location, below.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
*Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu. ft. (volume of space)
Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
__________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)
Example: 1792 cu. ft. (volume of space) x 20 = 35,840 (maximum Btu/Hr the space can support)
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace |
_________ Btu/Hr |
Gas water heater* |
_________ Btu/Hr |
Gas furnace |
_________ Btu/Hr |
Vented gas heater |
_________ Btu/Hr |
Gas fireplace logs |
_________ Btu/Hr |
Other gas appliances* |
+ ________ Btu/Hr |
Total |
= ________ Btu/Hr |
* Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors.
Example: |
|
|
Gas water heater |
30,000 |
Btu/Hr |
Vent-free fireplace |
10,000 |
Btu/Hr |
Total |
40,000 |
Btu/Hr |
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
________ |
Btu/Hr (maximum the space can support) |
________ |
Btu/Hr (actual amount of Btu/Hr used) |
Example: 35,840 Btu/Hr (maximum the space can support)
40,000 Btu/Hr (actual amount of Btu/Hr used)
113110-01A |
www.desatech.com |
7 |
AIR FOR COMBUSTION AND VENTILATION
Continued
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.
B.Vent room directly to the outdoors. See Ventilation Air From Outdoors.
C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING: If the area in which the fireplace may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3 or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see option 3, Figure 4). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
|
12" |
|
Ventilation Grills |
Ventilation |
Into Adjoining Room, |
Option 2 |
|
Grills |
Or |
into Adjoining |
Remove |
Room, |
Door into |
Option 1 |
Adjoining |
|
Room, |
|
Option 3 |
|
12" |
Figure 4 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent.
|
Outlet |
Ventilated |
|
Attic |
|
|
Air |
|
|
|
|
Outlet |
|
|
Air |
|
To Attic |
|
|
|
|
|
To |
|
|
Crawl |
Inlet |
|
Space |
|
|
|
Air |
|
|
|
Inlet Air |
Ventilated |
|
Crawl Space |
|
|
|
Figure 5 - Ventilation Air from Outdoors
8 |
www.desatech.com |
113110-01A |
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulatetheheatthroughoutthe house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified service person must install fireplace. Follow all local codes.
WARNING: Never install the fireplace
•in a bathroom or bedroom
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace
•as a fireplace insert
•in high traffic areas
•in windy or drafty areas
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces next to fireplace. Installingfireplacenexttovinylorcloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
IMPORTANT: Vent-free fireplaces add moisture to the air.Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 6 through 8.
Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear,sides,ortopofyourfireplace,exceptwherestandoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.
Note: When installing fireplace directly on carpeting, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.
Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 10).
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
WARNING: This appliance is equipped for (natural or propane/LP) gas. Field conversion is not permitted.
INSTALLATION ITEMS
Before installing fireplace, make sure you have the items listed below.
•external regulator (supplied by installer, for propane/LP units only)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection*
•ground joint union
•sediment trap
•tee joint
•pipe wrench
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 36 and 37.
Note: If desired, purchase a four-sided trim kit for built-in installations. See Accessories, pages 36 and 37.
113110-01A |
www.desatech.com |
9 |
INSTALLATION
Continued
FIREPLACE CLEARANCES
WARNING: Maintain the minimum clearances shown in Figure 6. If you can, provide greater clearances from floor, ceiling, and joining wall.
If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an CSA approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, pages 36 and 37).
If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation to secure your fireplace into the wall.
CAUTION: If you install the fireplace in a home garage
•fireplacepilotandburnermust be at least 18 inches above floor.
•locate fireplace where moving vehicle will not hit it.
For convenience and efficiency, install fireplace
•where there is easy access for operation, inspection, and service
•in coldest part of room
An optional blower kit is available from your dealer. See Accessories, pages 36 and 37. If planning to use blower, follow instructions provided with blower for power source.
Example |
* |
*Minimum 16 inches from Side Wall
Figure 6 - Minimum Clearance for Combustible to Wall
Minimum Clearances For Side
Combustible Material, Side Wall, and
Ceiling
A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 6).
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches.
C.For mantel clearances, see Figure 10 on page 12.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
Top |
Left and |
Bottom |
|
Right Sides |
and Rear |
36" |
6" |
0" |
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional trim kit accessory is available (see Accessories, pages 36 and 37). Trim will extend past sides of fireplace approximately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 10, page 12. Follow the instructions below to install the fireplace in this manner.
|
Actual |
Framing |
|
|
|
Height |
26" |
26 7/8" |
Front Width |
26 3/4" |
26 7/8" |
Depth |
9 1/2" |
10 1/2" |
Bottom |
3/4" |
3/4" |
|
|
|
1.Frame in rough opening. Use dimensions shown in Figure 7, page 11 for the rough opening. If installing in a corner, use dimensions shown in Figure 8 for the rough opening. The height is 26 7/8" which is the same as the wall opening above.
10 |
www.desatech.com |
113110-01A |
INSTALLATION
Continued
2.If installing GA3450T blower accessory, do so at this time. Follow instructions included with blower accessory.
Note: If not installing blower accessory, you may wish to run electrical wiring to your fireplace for future blower installation (see Accessories, pages 36 and 37). Use only approved three-wire electrical wiring.
Note: A qualified installer should make all electrical connections.
WARNING: If pre-wiring, do not connect wiring to any electrical source at this time.
Install fireplace electrical outlet and connect wiring to outlet before connecting to electrical source. The fireplace electrical outlet is included with the GA3450T blower accessory.
Only use the fireplace electrical outlet supplied with the GA3450T blower accessory.
3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping.
10 1/2"
267/8"
3/4" Off
The Floor
267/8" Minimum
Figure 7 - Rough Opening for Installing in Wall
365/8"
257/8"
267/8" 513/4"
Figure 8 - Rough Opening for Installing in Corner
4.If you have not assembled firebox, follow instructions beginning on page 5.
5.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
6.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, pages 17 and 18.
7.Bend four nailing flanges on outer casing with pliers (see Figure 9).
8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.
9.Check all gas connections for leaks. See
Checking Gas Connections, page 18.
10.If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim accessory for attaching trim.
IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top edge of the firebox. Combustible materials should never overlap the firebox front facing.
WARNING: Do not allow any combustible materials to overlap the firebox front facing.
IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots.
Wall Studs
Nails or |
Nailing |
Wood |
Flanges |
Screws |
|
Figure 9 - Attaching Fireplace to Wall Studs
113110-01A |
www.desatech.com |
11 |
INSTALLATION
Continued
WARNING:Donotallownoncombustible materials to cover any necessary openings like louvered slots.
WARNING: Never modify or cover the louvered slots on the front of the firebox.
WARNING:Useonlynoncombustiblemortaroradhesiveswhen overlapping the front facing with noncombustible facing material.
Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Wallsandmantelsabovethefireboxmaybecomehottothetouch. If installed properly, these temperatures meet the requirement ofthenationalproductstandard. Follow all minimum clearances shown in this manual.
Mantel Shelf
Note: |
10" |
|
8" |
||
All vertical |
||
measurements |
6" |
|
are from top of |
||
2 1/2" |
||
fireplace |
opening to bottom of mantel shelf. All measurements are in inches.
13" |
16" |
19" |
21" |
Side of
Firebox
Figure 10 - Minimum Mantel Clearances
for Built-In Installation
NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:
•raise the mantel to an acceptable height
•remove the mantel
OPTIONAL MANTEL INSTALLATION
Note: Refer to instructions provided with the mantel for assembly instructions. Refer to the following instructions for system installation. Refer to instructions on page 5 for fireplace assembly. Blower accessory should be installed if it is being used (see Installing Optional Blower Accessory GA3450T, pages 13 through 15).
1.Unscrew four screws that attach top louver to fireplace. Remove louver from fireplace and set aside (see Figure 11).
2.Place base assembly next to wall at installation location.
3.Place fireplace on wood base (see Figure 12, page 13).
4.Place mantel around fireplace on base (see Figure 12, page 13).
5.Assemble perimeter trim kit. See Assembling Perimeter Trim, page 13.
6.Firmly snap perimeter trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12, page 13).
7.Align perimeter trim kit for flush fit around opening.
8.Center mantel left to right on base making sure mantel is flush against wall.
9.Use two 3" wood screws provided and attach base of fireplace to wooden mantel base (see Figure 12, page 13).
10.Remove perimeter trim kit and mantel. Be careful not to damage wall or mantel.
Upper
Louver
Assembly
Figure 11 - Removing Top Louver
12 |
www.desatech.com |
113110-01A |