Operating modes
This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking.
If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.
Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.
Circulating-air mode:
An activated carbon filter must be fitted
for this operating mode (see Filters and maintenance).
The complete installation set and
replacement filters can be obtained from specialist outlets.
The corresponding accessory numbers can be found at the end of these operating instructions.
The extractor-hood fan extracts the
kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen.
The grease filter absorbs the grease
particles in the kitchen vapours.
The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous substances in the cooking vapours.
Light / fan switches Filter drawer
Description of appliance
Operating instructions:
Operating modes
Exhaust-air mode:
The extractor-hood fan extracts the
kitchen vapours and conveys them through the grease filter into the atmosphere.
The grease filter absorbs the solid
particles in the kitchen vapours.
The kitchen is kept almost free of grease
and odours.
D
If the extractor hood is operated in
exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel
heater, instantaneous water heater, boiler),
ensure that there is an adequate air supply which the heater requires for
combustion. Safe operation is possible provided that the
partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar).
17
Before using for the first time
Important notes:
The Instructions for Use apply to several
versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.
This extractor hood complies with all
relevant safety regulations. Repairs should be carried out by
qualified technicians only.
Improper repairs may put the user at considerable risk.
Do not flambé food directly under the
extractor hood.
Risk of grease filter catching fire due
! to flames.
Restrictions apply to the use of the
extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).
Gas hobs / gas cookers
Always use gas hobs in a proper and
safe manner.
Important:
The flames from the gas hob must always be covered by pots or pans.
The intense heat generated by the gas flames could cause damage to the
! extractor hood.
Before using your appliance for the first
time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance.
Please retain the operating and
installation instructions for a subsequent owner.
Do not use the appliance if damaged.The appliance is not intended for use
by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.
The appliance may be connected to
the mains by a qualified technician only.
Dispose of packaging materials
properly (see Installation instructions).
Light bulbs must always be fitted when
the extractor hood is in use.
Defective bulbs should be replaced
immediately to prevent the remaining bulbs from overloading.
Never operate the extractor hood
without a grease filter.
Overheated fat or oil can easily catch
fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.
18
Operating the extractor hood
Cooking vapours are best eliminated
by:
Switching on the extractor hood when you start cooking.
Only switching off the extractor hood
a few minutes after you have finished cooking.
Fan on / off
Light on / off
Intensive setting
Fan settings
Fan on / off
Intensive setting Reset button with
saturation display for grease filter
Fan settings
Light on / off
Switching off:
The extractor hood can be switched off in various ways.
Switch-off 1:
Sliding switch to 0 – switch off fans.
Switch-off 2:
Push in filter drawer to stop. (Sliding switch remains as selected).
To switch on the extractor again, just pull out the filter unit. The extractor hood will start at the most recent fan setting.
Light:
The light can be switched on at any time even when the appliance is off or the filter drawer is inserted.
Switching on:
Take hold of filter drawer handle and pull out the drawer.
Select the required fan setting.
Faults
If you have any queries or the appliance is faulty, please call customer service
(see list of customer service units).
Please give the following details when you call:
Product no. (E-Nr.) Serial no. (FD)
Enter the numbers in the above box. The numbers can be found on the rating plate inside the extractor hood following removal of the filter screen.
19
4. Clean the filters.
5. Insert the clean filters back into the hood.
6. Cancel the in the display.
Press the button.
Grease filters:
Metal-mesh filters are used to trap the grease particles in the cooking vapours.
The filter mats are made from non­combustible metal.
Caution:
As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired.
Important:
Clean the metal-mesh grease filters at regular intervals to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting.
If used in normal mode (daily 1 to 2 hours), the metal-mesh grease filter must be cleaned 1x a month.
Saturation indicator:
When the grease filter is saturated, the indicator starts flashing. You should now change the grease filter if you have not already done so.
Ensure that the grease filters are cleaned at regular intervals (approx. 1 month).
Cleaning the metal-mesh grease filters:
The filters can be cleaned in a
dishwasher. However, they may become slightly discoloured.
Important:
Do not wash highly saturated metal­mesh grease filters with other utensils.
If cleaning the filters by hand, soak them in
a hot soap solution. Then brush the filters, rinse thoroughly and leave to drain.
Filters and maintenance
Removing and inserting the metal-mesh grease filters:
Warning: The halogen bulbs must be
switched off and cool.
1. Pull the filter drawer all the way out.
2. Depress both catches at the front of the
grease filter and remove the grease filter.
3. Depress the catches at the rear of the grease filter and remove the grease filter.