PoE Edge Switch
Use this economical 6-port 10/100 switch, which has four 802.3af compliant PoE PSE ports for PoE devices.
Radio Interference Regulations
Federal Communications Commission and Industry Canada Radio Frequency Interference Statements
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
724-746-5500 | blackbox.com
Page 3
NOM Statement
Instrucciones de Seguridad (Normas Oficiales Mexicanas Electrical Safety Statement)
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato electric sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
Page 4
724-746-5500 | blackbox.com
NOM Statement
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada.
724-746-5500 | blackbox.com
Page 5
Trademarks Used in this Manual
Trademarks Used in this Manual
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.
Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Any other trademarks mentioned in this manual are acknowledged to be
the property of the trademark owners.
We‘re here to help! If you have any questions about your application
or our products, contact Black Box Tech Support at 724-746-5500
or go to blackbox.com and click on “Talk to Black Box.”
You’ll be live with one of our technical experts in less than 30 seconds.
Page 6
724-746-5500 | blackbox.com
Table of Contents
Table of Contents
1. SPECIFICATIONS .......................................................................... 9
1.1 Technical Specifications ........................................................ 9
1.2 Ordering Information ............................................................ 14
2. INTRODUCTION .......................................................................... 19
2.1 Inspecting the Package and Product ................................... 19
2.2 Product description .............................................................. 20
2.3 Frame Buffering and Latency .............................................. 23
2.4 Features and Benefits ......................................................... 26
3. INSTALLATION ............................................................................ 29
3.1 Locating the Edge Switch Unit ............................................. 29
3.2 LE1505-RACK for Rack Mounting of LPH240A .................. 32
3.3 LH1505P-RACK for Rack Mounting .................................... 33
3.4 DIN-Rail mounting option .................................................... 34
3.5 Power Requirement for LPH240A (48V) Edge Switch ........ 35
3.6 Powering the LPH240A with –48VDC power input .............. 36
3.7 LPH240A Series, DC-powered, -48VDC Installation ........... 37
3.8 Connecting Ethernet Media ................................................. 38
3.8.1 Connecting Twisted Pair ............................................ 39
3.8.2 Connecting Fiber Optic ST-type, “twist-lock” ............. 40
3.8.3 Connecting Fiber Optic SC-type, "Snap-In" ............... 41
3.8.4 Connecting Single-Mode Fiber Optic ......................... 41
3.8.5 Power Budget Calculations, Fiber Media .................. 42
3.8.6 Connections to NICs .................................................. 43
4.
OPERATION ................................................................................ 44
4.1 Dual-Speed Functionality, and Switching ............................ 44
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing ... 46
4.3 Dual LEDs, Front-panel and side-panel .............................. 47
4.4 Hardware operated Alarm Contact ...................................... 48
724-746-5500 | blackbox.com
Page 7
Table of Contents
5. TROUBLESHOOTING ................................................................. 50
5.1 Before Calling for Assistance .............................................. 51
5.2 When Calling for Assistance ................................................ 52
5.3 Return Material Authorization (RMA) Procedure ................. 53
5.4 Shipping and Packaging Information ................................... 54
APPENDIX A: WARRANTY INFORMATION ......................................... 55
Page 8
724-746-5500 | blackbox.com
Chapter 1: Specifications
1. SPECIFICATIONS
1.1 Technical Specifications
Ports Performance
When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps
Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T PoE: IEEE 802.3af Auto-sensing for speed: IEEE 802.3u
Packet-Processing Betw een Domains Filter and Forward Rate from 100Mbps ports: 148,800 pps max
Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward, non-blocking
Auto-learning: 2K address table Address buffer age-out time: 300 sec. Packet buffers memory: 128KB, dynamically shared on all domains Latency (not including packet time):
100 to 10 Mbps: 5μs 10 to 100Mbps: 15μs
Path Delay Value: 50 BT on all ports
LLL(Link-Loss-Learn): Factory default is activated on port 1 and 2 (allow to flush the internal address buffer, and qualify to use with S-
Ring and RSTP for faster recovery in ring topology)
724-746-5500 | blackbox.com
Page 9
Chapter 1: Specifications
Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode) - 412 m (1350 ft) 100BASE-FX, full-duplex: (multi-mode) - 2 km (6562 ft) 100BASE-FX, half-duplex: (single-mode) - 412 m (1350 ft) 100BASE-FX, full-duplex: (single-mode) - 20 km (65,620 ft)
Operating Environment LPH240A-H: -13ºF to 140ºF ( -25ºC to 60ºC)
Long term per agency tests (UL)
-40ºF to 185ºF (-40ºC to 85ºC) Short term per IEC Type tests. LPH240A-P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).
-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Storage Temperature
,
All models: -40ºF to 185ºF (-40ºC to 85ºC)
Cold Start
:
LPH240A-H to -20ºC LPH240A-P to -40ºC
Ambient Relative Humidity
Page 10
724-746-5500 | blackbox.com
: 5% to 95% (non-condensing)
Chapter 1: Specifications
Altitude (All models): -200 to 5000ft. (-60 – 15,000 m) Conformal Coating (optional) for humidity protection Note: H and P models are designed for NEBS compliance, including
vibration, shock and altitude.
Packaging:
Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit:
3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm)
Weight: all models: 9.5 oz. (285g); Cooling Method
:
Convection on the office model. The Hardened (H) factory floor and Extreme (P) temperature uncontrolled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling.
ALARM RELAY Terminal Block, H and P models only, two screw terminals:
Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
Mean Time Between Failure (MTBF): over 15 years, Telcordia (Bellcore) Method
724-746-5500 | blackbox.com
Page 11
Chapter 1: Specifications
Direct DC POWER SUPPLY: built-in terminal block for +, -, ground
-48V DC internal (range 46 to 60V DC),+ , -, ground.
Total power input required: for PoE ports, 66 Watts max. OR 1.4A @48VDC Power Consumption: Typical 3.5 watts, 4 watts max. (All six copper ports) Power Consumption: Typical 7 watts, 8.5 watts max. (4 PoE+ 2 non-PoE fiber port)
AC POWER SUPPLY
( using an external power adapter):
LPH240A-X-XX-48 models have an (8-15)VDC, 2.5-mm center +ve jack.
Option for 12VDC jack for wall mount, only be used to power the LPH240A unit, when no PoE devices are attached, act as non-PoE switch.
AC POWER SUPPLY
(using internal IEC320 connection)
LPH240A-X-XX models have an standard worldwide AC (100-250 VAC)
power input via IEC320, male recessed, UL listed and surge protected connector.
Port Connectors
:
RJ-45 Ports: supports 100BASE-TX and 10BASE-T with auto-cross
(MDIX). They are shielded 8-pin female connectors for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable. Fiber optic port: supports 100Base-FX with a choice of multimode SC, ST or singlemode SC connectors. (By default factory settings is at “Full” duplex on fiber ports).
Page 12
724-746-5500 | blackbox.com
Chapter 1: Specifications
LED Indicators (Front)
POWER: Steady ON when power applied 10/100: Steady ON for 100Mbps; OFF for 10 Mbps (copper ports only) LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates port is transmitting / receiving (ACT). F/H: Steady ON for full-duplex, OFF for half-duplex (Fiber port only)
Mounting options
Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4)
Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A
IEC 61850 EMC and Operating Conditions Class C Power Substations IEEE 1613 Env. Standard for Electrical Power Substations NEBS L3 and ETSI compliant including vibration, shock and altitude NEMA TS-2 and TEES for traffic control equipment
Warranty: Three years, return to factory Made in USA
724-746-5500 | blackbox.com
Page 13
Chapter 1: Specifications
1.2 Ordering Information
MODEL DESCRIPTION
LPH240A-H-48 6 port Hardened-rated PoE (802.3af) Power
sourcing Edge switch, four RJ-45 (PoE) + two RJ-45 port (non-PoE), 48VDC terminal block for power input. LPH240A-H-SC-48 6 port Hardened-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + one Multimode SC port (non-PoE), one RJ45 (non­ PoE), 48VDC terminal block for power input. LPH240A-H-SSC-48 Same as above, except a Singlemode SC replaces the Multimode SC port. LPH240A-H-ST-48 Same as above, except a Multimode ST replaces the SC port LPH240A-H-2SC-48 6 port Hardened-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + two Multimode SC port (non-PoE), 48VDC terminal block for power input. LPH240A-H-2SSC-48 Same as above, except a Singlemode SC replaces the Multimode SC port. LPH240A-H-2ST-48 Same as above, except a Multimode ST replaces the SC port.
Page 14
724-746-5500 | blackbox.com
Chapter 1: Specifications
Ordering Information con’t
MODEL DESCRIPTION
LPH240A-P-48 6 port Extreme-rated PoE (802.3af) Power
sourcing Edge switch, four RJ-45 (PoE) + two RJ-45 ports (non-PoE), 48VDC terminal block for power input. LPH240A-P-SC-48 6 port Extreme-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + one Multimode SC port (non-PoE), one RJ-45 (non­ PoE), 48VDC terminal block for power input. LPH240A-P-SSC-48 Same as above, except a Single-mode SC replaces the Multimode SC port. LPH240A-P-ST-48 Same as above, except a Multimode ST replaces the SC port LPH240A-P-2SC-48 6 port Extreme-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + two Multimode SC port (non-PoE), 48VDC terminal block for power input. LPH240A-P-2SSC-48 Same as above, except a Single-mode SC replaces the Multimode SC port. LPH240A-P-2ST-48 Same as above, except a Multimode ST replaces the SC port.
724-746-5500 | blackbox.com
Page 15
Chapter 1: Specifications
Ordering Information con’t
MODEL DESCRIPTION
LPH240A-H 6 port Hardened-rated PoE (802.3af) Power
sourcing Edge switch, four RJ-45 (PoE) + two RJ-45 ports (non-PoE), AC IEC320 connector for power input. LPH240A-H-SC 6 port Hardened-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + one Multimode SC port (non-PoE), one RJ45 (non­ PoE), AC IEC320 connector for power input. LPH240A-H-SSC Same as above, except a Single-mode SC replaces the Multimode SC port. LPH240A-H-ST Same as above, except a Multimode ST replaces the SC port LPH240A-H-2SC 6 port Hardened-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + two Multimode SC port (non-PoE), AC IEC320 connector for power input. LPH240A-H-2SSC Same as above, except a Single-mode SC replaces the Multimode SC port. LPH240A-H-2ST Same as above, except a Multimode ST replaces the SC port.
Page 16
724-746-5500 | blackbox.com
Chapter 1: Specifications
Ordering Information con’t
MODEL DESCRIPTION
LPH240A-P 6 port Extreme-rated PoE (802.3af) Power
sourcing Edge switch, four RJ-45 (PoE) + two RJ45 port (non-PoE), AC IEC320 connector for power input. LPH240A-P-SC 6 port Extreme-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + one Multimode SC port (non-PoE), one RJ45 (non­ PoE), AC IEC320 connector for power input. LPH240A-P-SSC Same as above, except a Singlemode SC replaces the Multimode SC port. LPH240A-P-ST Same as above, except a Multimode ST replaces the SC port. LPH240A-P-2SC 6 port Extreme-rated PoE (802.3af) Power sourcing Edge switch, four RJ-45 (PoE) + two Multimode SC port (non-PoE), AC IEC320 connector for power input. LPH240A-P-2SSC Same as above, except a Singlemode SC replaces the Multimode SC port.
LPH240A-P-2ST Same as above, except a Multimode ST replaces the SC port.
724-746-5500 | blackbox.com
Page 17
Loading...
+ 39 hidden pages