1.2.2 Operator’s obligation to exercise diligence 4
1.3 Description of safety symbols 4
2 Product Description 5
2.1 Product Overview 5
2.2 Connections 6
2.2.1 Power Supply 6
2.2.2 Data Connections 7
2.3 LED-Diagnosis 8
3 Installation 9
3.1 Transport and Unpacking 9
3.1.1 Transport 9
3.1.2 Unpacking 9
3.2 Mounting/ Demounting 10
3.3 Connecting devices 11
3.3.1 Connecting cables 11
4 Operation 12
4.1 Maintenance 12
4.1.1 Cleaning 12
4.1.2 Maintenance 12
4.2 Shutting down 12
4.2.1 Disposal 12
5 Dimensions 13
6 Technical Data 14
CU8005-0000 1
Page 4
Table of contents
7 Appendix 15
7.1 Beckhoff Support and Service 15
7.1.1 Beckhoff branches and partner companies Beckhoff Support 15
7.1.2 Beckhoff company headquarters 15
7.2 Approvals for USA and Canada 16
7.3 FCC Approval for USA 16
7.4 FCC Approval for Canada 16
2CU8005-0000
Page 5
Foreword
1 Foreword
1.1 Notes on the Documentation
This description is only intended for the use of trained specialists in control and automation engineering
who are familiar with the applicable national standards. It is essential that the following notes and
explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products describe d satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.
1.1.1 Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under
development. For that reason the documentation is not in every case checked for consistency with
performance data, standards or other characteristics. In the event that it contains technical or editorial
errors, we retain the right to make alterations at any time and without warning. No claims for the
modification of products that have already been supplied may be made on the basis of the data, diagrams
and descriptions in this documentation.
1.1.2 Trademarks
Beckhoff®, TwinCAT®, EtherCAT®, Safety over EtherCAT®, TwinSAFE® and XFC® are registered
trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.
Beckhoff Automation GmbH.
The reproduction, distribution and utilization of this document as well as the communication of its contents
to others without express authorization are prohibited. Offenders will be held liable for the payment of
damages. All rights reserved in the event of the grant of a patent, utility model or design.
1.1.4 Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply.
CU8005-0000 3
Page 6
Foreword
1.2 Safety instructions
1.2.1 State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the
application. Modifications to hardware or software configurations other than those described in the
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH.
1.2.2 Operator’s obligation to exercise diligence
The operator must ensure that
the product is only used as intended (see chapter Product Description)
the product is in a sound condition and in working order during operation (see chapter
Maintenance)
the product is operated, maintained and repaired only by suitably qualified and authorized
personnel
the personnel is instructed regularly about relevant occupational safety and environmental
protection aspects, and is familiar with the operating manual and in particular the safety notes
contained herein
the operation manual is in good condition and complete, and always available for reference at the
location of the product
none of the safety and warning notes attached to product are removed, and that all notes remain
legible.
1.3 Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to
the associated safety instructions.
Acute risk of injury!
DANGER
WARNING
CAUTION
Attention
If you do not adhere the safety advise adjoining this symbol, there is immediate
danger to life and health of individuals!
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is danger to life and
health of individuals!
Hazard to individuals!
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to
individuals!
Hazard to devices and environment
If you do not adhere the notice adjoining this symbol, there is obvious hazard to
materials and environment.
Note or pointer
Note
4CU8005-0000
This symbol indicates information that contributes to better understanding.
Page 7
Product Description
2 Product Description
2.1 Product Overview
The CU8005-0000 Beckhoff USB hub offers 4 USB downstream ports (type A). It can be used universally
in automation and office applications. The hub meets the special requirements of industri al applications
through several outstanding features:
User-friendly installation via integrated top-hat rail adapter
24 V
Delivers up to 1 A supply current from each USB downstream port
480 Mbit, 12 Mbit, and 1.5 Mbit support for compatibility to all USB standards
Compact industrial design
Clear quick diagnostic by separate LEDs for each USB port.
supply voltage – the standard in industrial environments
DC
CU8005-0000 5
Page 8
Product Description
2.2 Connections
2.2.1 Power Supply
The USB hub CU8005-0000 requires a 24 V
supply for it’s operation. The connection is made by
DC
means of the terminal X10, labeled 24 V. This supply feeds the hub electronics and, over the USB
downstream ports, the connected USB devices (5 V
). It is protected against polarity reversal.
DC
UL Requirements
Attention
To meet the UL requirements, the device must not be connected to unlimited power
sources!
Pin Assignment Power Supply Connector
Pin Assignment
1 GND
2 0 V
3 +24 V DC
6CU8005-0000
Page 9
Product Description
2.2.2 Data Connections
There are two kind of connectors: USB Port type B and USB type A (input). The pins are described
below:
USB Typ B Port (X20) (standard cable)
Pin Assignment
1 VCC
2 Data -
3 Data +
4 GND
Shield Shield
USB Typ A Port (X31, X32, X33, X34) (standard cable)
Pin Assignment
1 VCC
2 Data 3 Data +
4 GND
shield Shield
CU8005-0000 7
Page 10
Product Description
2.3 LED-Diagnostic
LED Allocation State Meaning
off no supply voltage P10 Power supply
control
P31 USB Port 1
P32 USB Port 2
P33 USB Port 3
P34 USB Port 4
shining green 5 V
shining green the total current of all 4 downstream ports is less than 2.5 A P11 Current
shining red the total current of all 4 downstream ports is bigger than 2.5 A
off port not operational
shining green port fully operational
blinking green software attention
shining red Error condition e.g. overcurrent (port current > 1 A or short circuit)
blinking red hardware attention
off port not operational
shining green port fully operational
blinking green software attention
shining red Error condition e.g. overcurrent (port current > 1 A or short circuit)
blinking red hardware attention
off port not operational
shining green port fully operational
blinking green software attention
shining red Error condition e.g. overcurrent (port current > 1 A or short circuit)
blinking red hardware attention
off port not operational
shining green port fully operational
blinking green software attention
shining red Error condition e.g. overcurrent (port current > 1 A or short circuit)
blinking red hardware attention
for downstream ports is provided
DC
8CU8005-0000
Page 11
Installation
3 Installation
3.1 Transport and Unpacking
The specified storage conditions must be observed (see chapter Technical Data).
3.1.1 Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts.
During transport, the unit should therefore be protected from excessive mechanical stress. Therefore,
please use the original packaging.
Danger of damage to the unit
Attention
Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation
occur, a delay time of approximately 12 hours must be allowed before the unit is switched on.
If the device is transported in cold weather or is exposed to extreme variations in
temperature, make sure that moisture (condensation) does not form on or inside the
device.
3.1.2 Unpacking
Proceed as follows to unpack the unit:
1. Remove packaging
2. Do not discard the original packaging. Keep it for future relocation
3. Check the delivery for completeness by comparing it with your order
4. Please keep the associated paperwork. It contains important information for handling the unit
5. Check the contents for visible shipping damage.
If you notice any shipping damage or inconsistencies between the contents and your order, you should
notify Beckhoff Service.
CU8005-0000 9
Page 12
Installation
3.2 Mounting/ Demounting
The USB hub CU8005-0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022:
To release the CU8005-0000 from the mounting rail:
1. first pull the lug at the bottom of the hub downwards by using a screw driver (1)
2. then pull the hub from the mounting rail (2).
10CU8005-0000
Page 13
Installation
3.3 Connecting devices
The power supply plug must be withdrawn
Attention
3.3.1 Connecting cables
The connections are documented in the section Product Description.
When connecting the cables to the CU8005-0000, proceed according to the following seq uence:
Switch off all the devices that are to be connected
Please read the documentation for the external devices prior to connecting them!
During thunderstorms, plug connector must neither be inserted nor removed!
When disconnecting a plug connector, always handle it at the plug. Do not pull the
cable!
Disconnect all the devices that are to be connected from the power supply
Connect all the cables between the CU8005-0000 and the devices that are to be connected
Reconnect all devices to the power supply.
3.3.1.1 Mounting power supply connector
The connector for the power supply has a clamp. It will be installed with a screwdriver:
2. 1. 3.4.
1. Insert screwdriver into the left hole
2. Plug bared cable into right hole
3. Remove screwdriver
4. The Cable is installed.
CU8005-0000 11
Page 14
Operation
4 Operation
4.1 Maintenance
Please also refer to chapter Safety instructions.
4.1.1 Cleaning
Disconnect power supply
DANGER
The device can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials,
thinners, scouring material or hard objects that could cause scratches.
4.1.2 Maintenance
Switch off the device and all connected devices, and disconnect the device from the
power supply.
The CU8005-0000 USB hub is maintenance-free.
4.2 Shutting down
4.2.1 Disposal
Observe national electronics scrap regulations
Note
In order to dispose of the device, it must be removed and fully dismantled:
Housing components (polycarbonate, polyamide (PA6.6)) are suitable for plastic recycling
Metal parts can be sent for metal recycling
Electronic parts such as disk drives and circuit boards must be disposed of in accordance with
national electronics scrap regulations.
Observe the national electronics scrap regulations when disposing of the device.
12CU8005-0000
Page 15
Dimensions
5 Dimensions
The product is characterized by small overall installed size. With a height of 100 mm, the module
dimensions exactly match those of the Beckhoff Bus Terminals. Together with the lowered connector
surfaces, this means that it can be used in a standard terminal box with a height of 120 mm
.
CU8005-0000 13
Page 16
Technical Data
6 Technical Data
Product name CU8005-0000
Number of USB type B ports (upstream) 1
Number of USB type A ports (downstream) 4
Supported standard USB 2.0
Supported baud rates 480 Mbit, 12 Mbit, 1.5 Mbit
Output current per port up to 1.0 A (at 5 V)
Status display via LEDs
USB wiring length maximum 5 meters
Power supply
Current consumption from 24 V open circuit operation: 80 mA
Dimensions (w x h x d) app. 34 mm x 100 mm x 86 mm
Weight app. 120 g
Permissible ambient temperature -0°C to +55°C (operation)
Permissible relative humidity 5% to 95%, no condensation
EMC resistance burst / ESD EN 60000-6-2 / EN 60000-6-4
Vibration / Shock resistance EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29
Assembly on 35 mm mounting rail conforms to EN 50022
Installation position any
Protection class IP20
Approvals CE, UL
24 V
To meet the UL requirements use 4 A fuse or class 2
power supply!
if connected with host: 110 mA
maximum: 1 A (with USB devices connected)
(with power supply terminal and lug for mounting rail
release)
-25°C to +70°C (transport/ storage)
(-25% / +50%), protected against polarity reversal.
DC
14CU8005-0000
Page 17
Appendix
7 Appendix
7.1 Beckhoff Support and Service
Beckhoff and their partners around the world offer comprehensive support and service, making available
fast and competent assistance with all questions related to Beckhoff products and system solutions.
7.1.1 Beckhoff branches and partner companies Beckhoff Support
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff
products!
The contact addresses for your country can be found in the list of Beckhoff branches and partner
companies: www.beckhoff.com
Support offers you comprehensive technical assistance, helping you not only with the application of
individual Beckhoff products, but also with other, wide-ranging services:
world-wide support
design, programming and commissioning of complex automation systems
and extensive training program for Beckhoff system components
FCC: Federal Communications Commission Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Technical modifications
Note
Technical modifications to the device may cause the loss of the FCC approval.
7.4 FCC Approval for Canada
FCC: Canadian Notice
This equipment does not exceed the Class A limits for radiated emissions as described in the Radio
Interference Regulations of the Canadian Department of Communications.
16CU8005-0000
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.