Beckhoff C5240 Installation Manual

Installation and Operating instructions for
C5240 | 19-inch slide-in Industrial PC
Version: 2.0 Date: 2020-04-02
Table of contents
C5240 1
Table of contents
1 Foreword 4
1.1 Notes on the Documentation 4
1.1.1 Liability Conditions 4
1.1.2 Trademarks 4
1.1.3 Patent Pending 4
1.1.4 Copyright 4
1.1.5 State at Delivery 4
1.1.6 Delivery conditions 4
1.2 Description of safety symbols 5
1.3 Basic safety measures 6
1.4 Operator’s obligation to exercise diligence 7
1.4.1 National regulations 7
1.4.2 Procedure in the event of a fault 7
1.4.3 Operator requirements 7
2 Product Description 8
2.1 Product overview 8
2.2 Appropriate Use 9
2.3 Opening the Housing 9
2.4 Access to the battery 11
2.5 Changing the filter mat 12
2.6 Interfaces from C5240 13
2.6.1 PS/2 connections (X103, X104) 13
2.6.2 USB interfaces USB1 – USB4 (X108, X109, X110, X111) 13
2.6.3 Network connection LAN1, LAN2 (X112, X113) 13
2.6.4 DVI (Digital Visual Interface) (X114, X115) 13
2.6.5 Serial interface COM1 (X116) 13
2.6.6 DisplayPort (X117) 13
2.6.7 Sound-On-Board (X120, X121, X122) 13
2.6.8 Additional plug-in cards (optional) 13
2.7 USB interfaces and Control Elements 14
2.7.1 USB interfaces (X212, X213) 14
2.7.2 ATX Push-button 14
2.7.3 Reset-button 14
2.7.4 Status LEDs 14
3 Installation 15
3.1 Transport and Unpacking 15
Table of contents
2 C5240
3.1.1 Transport 15
3.1.2 Unpacking 15
3.2 Installation of the PC in the control cabinet 16
3.2.1 Preparation of the control cabinet 16
3.3 Power supply of the Industrial PC 17
3.3.1 Current carrying capacity of the 100-240 V power supply unit 17
3.3.2 Mains Socket 17
3.3.3 Power cords Europe 17
3.3.4 Power cords USA / Canada 17
3.4 Power Supply with 24 VDC power supply unit (optional) 18
3.4.1 Beckhoff power supply technology 18
3.4.2 Current carrying capacity of the 24 V power supply unit 19
3.4.3 Pin assignment of the connectors 19
3.4.4 Fitting the Cables 20
3.4.5 Connecting Power Supply 21
3.4.6 Wiring diagram 22
3.5 Connecting the Industrial PC 23
3.5.1 Connecting cables 23
3.5.2 Check voltage rating and connect. 23
4 Operating Instructions 24
4.1 Switching the Industrial PC on and off 24
4.1.1 Switch on 24
4.1.2 Shutting down and switching off 24
4.1.3 First switching on and driver installation 24
4.2 Servicing and maintenance 25
4.2.1 Cleaning of the Industrial PC 25
4.2.2 Maintenance 25
4.2.3 Replacing the Battery on the Motherboard 25
4.3 Emergency procedures 25
4.4 Shutting down 25
4.4.1 Disposal 25
5 Troubleshooting 26 6 Assembly dimensions 27 7 Technical Data 29 8 Appendix 30
8.1 Beckhoff Support and Service 30
8.1.1 Beckhoff branches and partner companies 30
8.1.2 Beckhoff company headquarters 30
Table of contents
C5240 3
8.2 Approvals for USA and Canada 31
8.3 FCC Approvals for the United States of America 31
8.4 FCC Approval for Canada 31
Foreword
4 C5240
1 Foreword
1.1 Notes on the Documentation
This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
1.1.1 Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard.
1.1.2 Trademarks
Beckhoff®, TwinCAT®, EtherCAT®, Safety over EtherCAT®, TwinSAFE® and XFC® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
1.1.3 Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries. The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.
1.1.4 Copyright
©
Beckhoff Automation GmbH & Co.KG. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
1.1.5 State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG.
1.1.6 Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co.KG apply.
Foreword
C5240 5
1.2 Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
DANGER
Acute risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals!
WARNING
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is danger to life and health of individuals!
CAUTION
Hazard to individuals!
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to individuals!
Attention
Hazard to devices and environment
If you do not adhere the notice adjoining this symbol, there is obvious hazard to materials and environment.
Note
Note or pointer
This symbol indicates information that contributes to better understanding.
Foreword
6 C5240
1.3 Basic safety measures
Before the Industrial PC is switched off, software that is running must be properly closed. Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the
Industrial PC on and off.
Warning
Switch off all parts of the equipment, then uncouple the fieldbus
Before opening the housing, and whenever the Industrial PC is not being used for control purposes (such as during functional checks after a repair), all parts of the equipment must first be switched off, after which the Industrial PC is to be disconnected from the equipment.
Pulling out the fieldbus connection plug uncouples the PC (optional). Items of equipment that have been switched off must be secured against being switched on again.
The Industrial PC’s power supply unit must be supplied with 100V
AC
– 240 VAC. Optional a 24 VDC power
supply unit with UPS is available.
DANGER
Do not open the power supply unit while voltage is applied!
The supply voltage must be switched off before the power supply unit housing is opened.
Warning
Do not exchange any parts when under power
When components are being fitted or removed, the supply voltage must be switched off.
Fitting work on the Industrial PC can result in damage:
if metal objects such as screws or tools fall onto operating circuit boards.
if connecting cables internal to the PC are removed or inserted during
operation.
if plug-in cards are removed or inserted when the PC is switched on.
Foreword
C5240 7
1.4 Operator’s obligation to exercise diligence
The operator must ensure that
the product is only used as intended (see chapter Product Description)
the product is in a sound condition and in working order during operation
the product is operated, maintained and repaired only by suitably qualified and authorized
personnel
the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein
the operation manual is in good condition and complete, and always available for reference at the location of the product
Attention
Only trained persons may open the Industrial PC housing
The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC.
1.4.1 National regulations
Depending on the type of machine and plant in which the Industrial PC is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator. These regulations cover, amongst other things, the intervals between inspections of the controller. The operator must initiate such inspections in good time.
1.4.2 Procedure in the event of a fault
In the event of faults at the Industrial PC, the list in the section Troubleshooting can be used to determine the measures to be taken.
1.4.3 Operator requirements
Anyone who uses the Industrial PC must have read these operating instructions and must be familiar with all the functions of the software installed on the Industrial PC to which he has access.
Product Description
8 C5240
2 Product Description
2.1 Product overview
C5240 | 19-inch slide-in Industrial PC
The C5240 Industrial PC expands the C52xx Industrial PC series by a version with four height units and seven PCI and PCIe plug-in card slots in 24 V DC or 110…230 V AC versions. The basic configuration includes three 5¼-inch drive bays behind the front flap. As an option, three additional 5¼-inch drive bays are available ex-factory. It is designed for installation in a 19-inch rack and is equipped with components of the highest performance class according to the ATX standard.
A Beckhoff industrial motherboard is used with Intel® Celeron®, Pentium®, Core™ i3, i5 or i7 fourth, sixth or seventh generation processors. The seventh generation requires a Windows 10 64-bit operating system. With the fourth and sixth generation, Windows 7 32-bit or 64-bit can be used besides Windows 10.
The C5240 is ideally suited for use in machine and plant engineering, for example with TwinCAT automation software.
The Industrial PC offers the following benefits:
7-slot slide-in housing ATX for 19-inch racks, 4 rack units
all slots for full-length plug-in cards
lockable front flap
card holders
protection class: front side IP50, back side IP20
operating temperature 0…55 °C.
Product Description
C5240 9
2.2 Appropriate Use
The C5240 Industrial PC has been designed as a rack mount PC for fitting into 19-inch racks used in machine and plant engineering applications.
Danger
Risk of explosion!
The Industrial PC must not be used where there is a risk of explosion.
2.3 Opening the Housing
Attention
Only trained persons may open the Industrial PC housing!
Before opening the PC housing, the power plug must be drawn.
Opening the front flap
In order to gain access to the power pushbutton and to the drives, open the flap on the front with the key provided for the purpose (see photo above).
Opening the housing
In order to open the PC housing, remove the 2 fastening screws on top of the housing cover (see arrows) using a cross-head screwdriver. Push the cover backwards and then lift it up to get access to the hard drive, processor, memory, plug-in cards and battery.
Product Description
10 C5240
Removing the card holder
Remove the 6 fastening screws of the card holder (see arrows) using a cross-head screwdriver. The holder can then be lifted up.
View of the open PC
The standard ATX Motherboard (1) with six slots for plug-in cards (2) is located under the housing cover. The power supply unit (3) and the hard drive (4) are easily accessible. The connections to the outside are located at the rear of the housing (5) and behind the front flap.
5
3 1
2
4
Product Description
C5240 11
2.4 Access to the battery
Removing the cover allows access to the battery.
WARNING
Danger of Explosion!
The battery is a CR2032 type (nominal voltage: 3.0 V) from e.g. Panasonic or Sanyo. Replace battery only with the identical type or an alternative type recommended by the manufacturer. Notice correct polarity!
Polarität der Batterie:
WARNING
Handling of Lithium Batteries
Lithium Batteries should not be recharged, exposed to fire, opened and they should be protected against sunlight and moisture.
-
+
Product Description
12 C5240
2.5 Changing the filter mat
If the Industrial PC is used in an environment where the air is particularly dirty, the fan's filter mat should be examined at regular intervals to see how dirty it is, and should be exchanged, if necessary, for an original Beckhoff filter mat.
Order number
Description
C9900-Z326
Filter mat for C5240 with three 5¼-inch slots, 5 per pack
C9900-Z327
Filter mat for C5240 with six 5¼-inch slots, 5 per pack
Front view with filter cover
Access to the filter mat is obtained behind the front flap. This must be opened with its key. After removing the two cross-head screws (2) the filter cover (1) can be removed.
Front view with fan and filter mat
After the mat (3) has been changed the filter is refitted in the reverse sequence.
2 1 3 1 2
Product Description
C5240 13
2.6 Interfaces from C5240
2.6.1 PS/2 connections (X103, X104)
The upper PS/2 connector (X104) allows a PS/2 mouse to be used, while a PC keyboard can be connected to the lower PS/2 connector (X103).
2.6.2 USB interfaces USB1 – USB4 (X108, X109, X110, X111)
The four USB interfaces (X108 – X111) are used to connect peripheral devices with USB connections. USB3.0 standard is supported.
Two more USB interfaces (X212 – X213) are located behind the front flap. USB2.0 standard is supported.
2.6.3 Network connection LAN1, LAN2 (X112, X113)
The RJ-45 connectors (X112, X113) allow the PC to be connected to a 100/1000BASE-T Local Area Network (LAN).
2.6.4 DVI (Digital Visual Interface) (X114, X115)
The DVI connectors (X114, X115) are used for transferring the video signal. DVI-D standard is supported.
2.6.5 Serial interface COM1 (X116)
The basic version of the Industrial PC has one serial interfaces COM1 (X116), using the type RS 232, which is brought to a 9 pin SUB-D plug connector.
2.6.6 DisplayPort (X117)
The DisplayPort (X117) is used for transferring the video signal.
2.6.7 Sound-On-Board (X120, X121, X122)
The Industrial PC has an on-board-interface with the following connectors: Line In (X122), Line Out (X121) and Microphone jack (X120).
2.6.8 Additional plug-in cards (optional)
There is a type plate on the top of the Industrial PC which provides information about the hardware configuration of the Industrial PC at the time it was supplied.
Product Description
14 C5240
2.7 USB interfaces and Control Elements
Two additional USB interfaces and the control elements are located behind a flap at the front side of the Industrial PC. After unlocking the flap with the key, it can be folded down. You now have access to the control elements:
Interfaces and Control Elements behind the front flap
2.7.1 USB interfaces (X212, X213)
The two USB interfaces (X212 – X213) are used to connect peripheral devices with USB connections. USB2.0 standard is supported.
2.7.2 ATX Push-button
The Industrial PC is switched on via the push-button (ATX) (Power on).
2.7.3 Reset-button
The reset-button enables re-booting the Industrial PC.
2.7.4 Status LEDs
The LED HDD is illuminated at HDD access.
The LED PWR is illuminated when power is on.
The LED FB is a multi-color LED and shows the status of fieldbus and TwinCAT:
Color LED FB
Description
red
TwinCAT STOP
blue
TwinCAT CONFIG
blue/ red blinking
TwinCAT CONFIG with Bus Error
green
TwinCAT RUN
green/ red blinking
TwinCAT RUN with Bus Error
X212
Status LEDs
Reset­button
ATX­button
X213
Installation
C5240 15
3 Installation
3.1 Transport and Unpacking
The specified storage conditions must be observed (see chapter Technical Data).
3.1.1 Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts. During transport, the Industrial PC should be protected from excessive mechanical stress. Therefore, please use the original packaging.
Attention
Danger of damage to the unit
If the device is transported in cold weather or is exposed to extreme variations in temperature, make sure that moisture (condensation) does not form on or inside the device.
Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation occur, a delay time of approximately 12 hours must be allowed before the unit is switched on.
3.1.2 Unpacking
Proceed as follows to unpack the unit:
1. Remove packaging.
2. Do not discard the original packaging. Keep it for future relocation.
3. Check the delivery for completeness by comparing it with your order.
4. Please keep the associated paperwork. It contains important information for handling the unit.
5. Check the contents for visible shipping damage.
6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service.
Installation
16 C5240
3.2 Installation of the PC in the control cabinet
The C5240 Industrial PC has been designed as a rack mount PC for fitting into 19-inch racks used in machine and plant engineering applications.
The ambient conditions specified for operation must be observed (see chapter Technical Data).
3.2.1 Preparation of the control cabinet
Four holes for the fixing bolts have to be provided in the control cabinet according to the dimensions of the PC (see chapter Assembly dimensions).
Note
Circulation of air
When the unit is installed in an enclosure, adequate space for ventilation and for opening the PC must be provided.
The clearance above and below the housing must be at least 5 cm in order to ensure adequate ventilation of the PC.
Attention
Avoid extreme environmental conditions
Extreme environmental conditions should be avoided as far as possible. Protect the PC from dust, moisture and heat.
The ventilation slots of the PC must not be covered.
Installation
C5240 17
3.3 Power supply of the Industrial PC
The Industrial PC is fitted with a 100-240 V/ 3 A max., 50-60 Hz full range power supply unit (with the option of an uninterruptible power supply UPS).
3.3.1 Current carrying capacity of the 100-240 V power supply unit
Output voltages from the 100-240 V power supply unit
Current loading maximum
+3.3 V
21.0 A
+5 V stand by
2.5 A
+5 V
15.0 A
+12 V1
11.0 A
+12 V2
8.0 A
-12 V
0.3 A
3.3.2 Mains Socket
A mains socket is located at the rear of the PC housing in order to connect the power supply.
Socket at the PC housing
3.3.3 Power cords Europe
In the area Europe you use the provided cable with inlet connector for non-heating apparatus to connect the Industrial-PC to the power supply:
3.3.4 Power cords USA / Canada
In the area USA / Canada the power supply cable must show the following specifications according to the supply voltage:
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V, 10 A, Type SJT or Type
SVT; one end terminates in NEMA 5-15P/-20P grounding-type attachment plug, other end in
appliance coupler. Minimum temperature rating of supply cables should be 80 °C. or Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V, 10 A, Type SJT or Type
SVT; one end terminates in NEMA 6-15P/-20P grounding-type attachment plug, other end in
appliance coupler. Minimum temperature rating of supply cables should be 80 °C.
Installation
18 C5240
3.4 Power Supply with 24 VDC power supply unit (optional)
Note
Uninterruptible power supply (UPS)
When the Industrial PC is provided with a power supply unit with integrated UPS (order option) you can realize an uninterruptible power supply (UPS) using the battery pack C9900-U330 or C9900-U332.
WARNING
Danger of Explosion!
Danger of Explosion if using other battery packs!
3.4.1 Beckhoff power supply technology
Schematic diagram of power supply unit wirings
Industrial PCs equipped with a UPS are in actual use frequently switched off by simply turning off the supply voltage. In this case the PC shuts down via the battery. However, over time this reduces the service life of the battery.
The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
In addition to the main switch this innovative solution uses an ON/OFF switch for the machine. Basically, the main switch remains switched on and provides the power supply for the PC during shutdown. Via the PC ON-input of the power supply the PC gets the command to shut down the operating system.
Once the PC has shut down, the PC power supply unit sets the Power Status-output (P-S) to 0, what indicates that the process is complete and that the main voltage can be switched off. This can be done manually via a signal lamp connection or via a contactor. With this solution the main switch generally only has to be switched off if the control cabinet has to be opened. The battery will only be used in the event of a power failure.
In order to maintain a screen display for the Industrial PC in the event of a power failure, the power supply unit is equipped with a UPS output 27 V / 1.4 A (max. 2.5 A from 2016 and later), for connecting a
Installation
C5240 19
Control Panel with a display dimension up to 19 inches. This enables a power failure to be visualized and displayed to the user. Once the PC has shut down, the UPS output is switched off.
For a detailed functional description please refer to section Connecting Power Supply.
3.4.2 Current carrying capacity of the 24 V power supply unit
Output voltages from the 24 V power supply unit
Current loading maximum
+3.3 V
12.0 A
+5 V stand by
1.5 A
+5 V
14.0 A
-5 V
0.3 A
+12
12.0 A
-12 V
0.5 A
3.4.3 Pin assignment of the connectors
Two 5-pin plug connectors with CAGE CLAMP connection are installed at the PC housing in order to connect the 24 VDC power supply and the external components.
Pin assignment power supply
Pin assignment for connecting the power supply and the battery pack (optional)
X101
Pin
Function
1
+
24 VDC Power Supply
2
-
3
4
+
Battery Pack (with UPS only)
5
-
5 4 3 2 1
Installation
20 C5240
Pin assignment external wiring
Pin assignment for connecting the power switch
X102
3.4.4 Fitting the Cables
Fit the cables for the power supply of the Industrial PC, the connection of the battery pack as well as the connection of the power-switch in accordance with the wiring diagram, using the included material for assembling the connectors.
Materials for assembly of the connector
Female plug connector 5-pole
Strain relief housing
Fitting the connector
The connector is specified for 16 A and can lift conductive cross-sections until 1.5 mm2.
The plug is fitted to the cable as follows:
1. Strip insulation from the cable ends (insulation length 8 – 9 mm).
2. Push the conductors into their mountings, simply by pushing them in as indicated on the pin
assignment label.
3. Push the lower part of the strain relief housing onto the top of the female plug connector until it
snaps into place.
4. Relieve the strain on the supply cable by fixing it in place with the cable clamp and fixing screws.
5. Fix the upper part of the strain relief housing by snapping it onto the lower part.
Pin
Function
1
Power-Status
2
PC-ON
3
24VDC Power Supply +pole
1 2 3
Installation
C5240 21
3.4.5 Connecting Power Supply
The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customized components for shutting down the PC.
Cable Cross Sections
For the connection of the power supply, wiring with a cable-cross-section of 1.5 mm2 must be used. With bigger distances between voltage source and PC, you take the voltage drop as a function of the
cable-cross-section as well as voltage fluctuations of your distribution voltage into account, so that is secured that the voltage doesn't fall under 22 V at the power supply.
Attention
Insert fuse
The power supply must be protected with maximum 16 A.
Configuration for shutting down the PC The connections for shutting down the Industrial PCs are established via the PC_ON input and the Power
Status output.
PC_ON and Power Status functions
If the PC_ON input is connected to 24 V via a switch, the PC shuts down according to the rules. The PC_ON signal is inverted, i.e. the PC shuts down if the 24 V connection is live.
If the PC_ON input is NOT connected by the user, the PC can be booted in the familiar way by connecting the supply voltage and shut down via the battery by switching off the supply voltage.
Attention
Service life of the rechargeable battery
This procedure significantly reduces the service life of the rechargeable battery and should therefore not be used.
Once the PC has shut down, the Power Status output is switched from 24 V to 0 V. Via this output a signal lamp can be connected or a contactor for de-energizing the whole system. The maximum load for the Power Status output is 0.5 A and a suitable fuse should be provided.
UPS output
In order to maintain a screen display for the PC in the event of a power failure, the power supply unit is equipped with a UPS output for connecting a Control Panel. The maximum load for the output is 1.4 A (max. 2.5 A from 2016 and later).
UPS output function
The 24 V DC connection at the UPS output is live even after a power failure. The maximum load is 1.4 A (max. 2.5 A from 2016 and later).
Once the PC has been de-energized via the UPS software, the UPS output is switched to 0 V. Any connected panel is thus switched off, and total discharge of the rechargeable battery is prevented.
Installation
22 C5240
3.4.6 Wiring diagram
Wiring according to the wiring diagram (the circuit of PC_ON and Power-Status is symbolical):
Wiring diagram external switch and power supply
Note
Connection of the Battery Pack and UPS Output
Connection of the Battery Pack and UPS Output only in combination with integrated UPS (order option).
Installation
C5240 23
3.5 Connecting the Industrial PC
Attention
The mains plug must be disconnected
The power supply plug must be withdrawn! Please read the documentation for the external devices prior to connecting them! During thunderstorms, plug connector must neither be inserted nor removed! When disconnecting a plug connector, always handle it at the plug. Do not pull the cable!
3.5.1 Connecting cables
The connections are located at the top side of the Industrial PC and are documented in the Product
Description chapter.
When connecting the cables to the Industrial PC, proceed according to the following sequence:
Switch off all the devices that are to be connected.
Disconnect all the devices that are to be connected from the power supply.
Connect all the cables between the Industrial PC and to the devices that are to be connected.
Connect all data transfer cables (if present) to the appropriate plug-in receptacles of the data/
telecommunication networks.
Reconnect all devices to the power supply.
3.5.2 Check voltage rating and connect.
When fitted with 100-240 VAC 50/60 Hz power supply:
1. Check that the mains voltage is correct.
2. Insert the provided power supply cable into the Industrial PC's power supply socket. Then connect it to a power socket with a grounded earth connection.
When fitted with the (optional) 24 VDC power supply unit:
1. Check that the external power supply is providing the correct voltage.
2. Insert the power supply cable that you have assembled into the Industrial PC's power supply socket. Then connect it to your external 24 V power supply.
Attention
Use same type of rechargeable battery
If a 24 V UPS is installed, the same type of rechargeable battery must be used.
Operating Instructions
24 C5240
4 Operating Instructions
4.1 Switching the Industrial PC on and off
4.1.1 Switch on
The Industrial PC has its own mains switch. The Industrial PC will start when the main switch switched on.
4.1.2 Shutting down and switching off
When the plant is switched off, or when it is disconnected from its power supply, the Industrial PC will be switched off.
Control software such as is typically used on Industrial PCs permits various users to be given different rights. A user who may not close software may also not switch the Industrial PC off, since data can be lost from the hard disk by switching off while software is running.
Attention
First shut down, then switch off the PC
If the Industrial PC is switched off as the software is writing a file to the memory drive, the file will be destroyed. Control software typically writes something to the memory drive every few seconds, so that the probability of causing damage by switching off while the software is running is very high.
Attention
Switch off power supply
When you have shut down the Industrial PC, you have to switch off power supply for at least 10 seconds before rebooting the system.
After resetting power supply the PC will start booting automatically.
4.1.3 First switching on and driver installation
When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will be started. In this case, all the required drivers for any additional, optional hardware components ordered with the PC will already have been installed.
If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices.
Operating Instructions
C5240 25
4.2 Servicing and maintenance
4.2.1 Cleaning of the Industrial PC
DANGER
Disconnect power supply
Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply.
The device can be cleaned with a soft, damp cleaning cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
4.2.2 Maintenance
The Industrial PC is maintenance-free.
4.2.3 Replacing the Battery on the Motherboard
A used battery on the motherboard has to be replaced. See also chapter Access to the battery.
WARNING
Danger of Explosion!
The battery is a CR2032 type (nominal voltage: 3.0 V) from e.g. Panasonic or Sanyo. Replace battery only with the identical type or an alternative type recommended by the manufacturer. Notice correct polarity!
WARNING
Handling of Lithium Batteries
Lithium Batteries should not be recharged, exposed to fire, opened and they should be protected against sunlight and moisture.
The used battery must be disposed of in accordance with national electronics scrap regulations.
4.3 Emergency procedures
In case of fire, the Industrial PC should be extinguished with powder or nitrogen.
4.4 Shutting down
4.4.1 Disposal
Note
Observe national electronics scrap regulations
Observe the national electronics scrap regulations when disposing of the device.
In order to dispose of the device, it must be removed and fully dismantled:
Housing components (polycarbonate, polyamide (PA6.6)) are suitable for plastic recycling
Metal parts can be sent for metal recycling
Electronic parts such as disk drives and circuit boards must be disposed of in accordance with
national electronics scrap regulations.
Troubleshooting
26 C5240
5 Troubleshooting
Fault
Cause
Procedure
Nothing happens after the Industrial PC has been switched on
No power supply to the Industrial PC
Other cause
Check power supply cable
Call Beckhoff Service
The Industrial PC does not boot fully
CD in drive
Setup settings are incorrect Other cause
Remove CD and press any key
Check the setup settings Call Beckhoff Service
Computer boots, software starts, but control does not operate correctly
Cause of the fault is either in the software or in parts of the plant outside the Industrial PC
Call the manufacturer of the machine or the software Memory device access error
Faulty device
Call Beckhoff Service
The Industrial PC functions only partially or only part of the time, e.g. no or dark picture, but disk drive responds when switching on
Defective components in the Industrial PC
Call Beckhoff Service
Assembly dimensions
C5240 27
6 Assembly dimensions
Industrial PC C5240
Attention
Notice mounting orientation
The assembly of the unit must take place with the orientation diagrammed here.
All dimensions in mm.
Side view
Top view
Front view
Assembly dimensions
28 C5240
Attention
Notice mounting orientation
The assembly of the unit must take place with the orientation diagrammed here.
All dimensions in mm.
With guide rail Maedler Accuride 2907
Top view
Side view
Technical Data
C5240 29
7 Technical Data
Danger
Risk of explosion!
Do not use the Industrial PC in areas of explosive hazard!
Product description
C5240
Dimensions (B x H x T)
482 x 177 x 511 mm (with handles)
Weight
17.0 kg (basic configuration)
Supply voltage
100 V
AC
- 240 VAC, 50 - 60 Hz
24 VDC power supply (optional)
22 - 30 VDC
Power consumption
C5240-0010: 70 W for the basic version
Interfaces
2 x PS/2 2 x DVI-D 1 x DisplayPort 2 x RJ-45 Ethernet 100/1000 BASE-T 4 x USB 2.0 2 x USB 3.0 1 x RS232 D-Sub-9
Protection class
IP50
Shock resistance (Sinusoidal vibration)
EN 60068-2-6: 10 to 58 Hz: 0.035 mm 58 to 500 Hz: 0.5 G (~ 5 m/ s2)
Shock resistance (during reading of CD-ROM)
EN 60068-2-6: 10 to 58 Hz: 0.019 mm 58 to 500 Hz: 0.25 G (~ 2.5 m/ s2)
Shock resistance (Shock)
EN 60068-2-27: 5 G (~ 50 m/ s2), duration: 30 ms
Shock resistance (during reading of CD-ROM)
EN 60068-2-27: 5 G (~ 50 m/ s2), duration: 11 ms EMC compatibility
Resistance to interference conforms to EN 61000-6-2
EMC compatibility
Emission of interference conforms to EN 61000-6-4
Permissible ambient temperature
0°C to +55°C (operation)
-20°C to +65°C (transport/ storage)
Permissible relative humidity
to 95%, no condensation
Transport and storage
The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. Suitable packaging of the Industrial PC can improve the resistance to impact during transport.
Certifications
CE
Appendix
30 C5240
8 Appendix
8.1 Beckhoff Support and Service
Beckhoff and their partners around the world offer comprehensive support and service, making available fast and competent assistance with all questions related to Beckhoff products and system solutions.
8.1.1 Beckhoff branches and partner companies
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com. You will also find further documentation for Beckhoff components there.
8.1.2 Beckhoff company headquarters
Beckhoff Automation GmbH & Co. KG Huelshorstweg 20 33415 Verl Germany
Phone: + 49 (0) 5246/963-0 Fax: + 49 (0) 5246/963-198 E-mail: info@beckhoff.de Web: http://www.beckhoff.de/
Beckhoff Support
Support offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with other, wide-ranging services:
world-wide support
design, programming and commissioning of complex automation systems
and extensive training program for Beckhoff system components
Hotline: + 49 (0) 5246/963-157 Fax: + 49 (0) 5246/963-9157 E-mail: support@beckhoff.com
Beckhoff Service
The Beckhoff Service Center supports you in all matters of after-sales service:
on-site service
repair service
spare parts service
hotline service
Hotline: + 49 (0) 5246/963-460 Fax: + 49 (0) 5246/963-479 E-mail: service@beckhoff.com
If servicing is required, please quote the project number of your product.
Appendix
C5240 31
8.2 Approvals for USA and Canada
8.3 FCC Approvals for the United States of America
FCC: Federal Communications Commission Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note
Technical modifications
Technological changes to the device may cause the loss of the FCC approval.
8.4 FCC Approval for Canada
FCC: Canadian Notice
This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications.