2 Product Description 8
2.1 Product overview 8
2.2 Appropriate Use 9
2.3 Opening the Housing 9
2.4 Access to the battery 11
2.5 Changing the filter mat 12
2.6 Interfaces from C5240 13
2.6.1 PS/2 connections (X103, X104) 13
2.6.2 USB interfaces USB1 – USB4 (X108, X109, X110, X111) 13
2.6.3 Network connection LAN1, LAN2 (X112, X113) 13
2.6.4 DVI (Digital Visual Interface) (X114, X115) 13
2.6.5 Serial interface COM1 (X116) 13
2.6.6 DisplayPort (X117) 13
2.6.7 Sound-On-Board (X120, X121, X122) 13
2.6.8 Additional plug-in cards (optional) 13
2.7 USB interfaces and Control Elements 14
2.7.1 USB interfaces (X212, X213) 14
2.7.2 ATX Push-button 14
2.7.3 Reset-button 14
2.7.4 Status LEDs 14
3 Installation 15
3.1 Transport and Unpacking 15
Table of contents
2 C5240
3.1.1 Transport 15
3.1.2 Unpacking 15
3.2 Installation of the PC in the control cabinet 16
3.2.1 Preparation of the control cabinet 16
3.3 Power supply of the Industrial PC 17
3.3.1 Current carrying capacity of the 100-240 V power supply unit 17
3.3.2 Mains Socket 17
3.3.3 Power cords Europe 17
3.3.4 Power cords USA / Canada 17
3.4 Power Supply with 24 VDC power supply unit (optional) 18
3.4.1 Beckhoff power supply technology 18
3.4.2 Current carrying capacity of the 24 V power supply unit 19
3.4.3 Pin assignment of the connectors 19
3.4.4 Fitting the Cables 20
3.4.5 Connecting Power Supply 21
3.4.6 Wiring diagram 22
3.5 Connecting the Industrial PC 23
3.5.1 Connecting cables 23
3.5.2 Check voltage rating and connect. 23
4 Operating Instructions 24
4.1 Switching the Industrial PC on and off 24
4.1.1 Switch on 24
4.1.2 Shutting down and switching off 24
4.1.3 First switching on and driver installation 24
4.2 Servicing and maintenance 25
4.2.1 Cleaning of the Industrial PC 25
4.2.2 Maintenance 25
4.2.3 Replacing the Battery on the Motherboard 25
4.3 Emergency procedures 25
4.4 Shutting down 25
4.4.1 Disposal 25
5 Troubleshooting 26 6 Assembly dimensions 27 7 Technical Data 29 8 Appendix 30
8.1 Beckhoff Support and Service 30
8.1.1 Beckhoff branches and partner companies 30
8.1.2 Beckhoff company headquarters 30
Table of contents
C5240 3
8.2 Approvals for USA and Canada 31
8.3 FCC Approvals for the United States of America 31
8.4 FCC Approval for Canada 31
Foreword
4 C5240
1 Foreword
1.1 Notes on the Documentation
This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
1.1.1 Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard.
1.1.2 Trademarks
Beckhoff®, TwinCAT®, EtherCAT®, Safety over EtherCAT®, TwinSAFE® and XFC® are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
1.1.3 Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries. The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.
1.1.4 Copyright
©
Beckhoff Automation GmbH & Co.KG. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
1.1.5 State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG.
1.1.6 Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co.KG apply.
Foreword
C5240 5
1.2 Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
DANGER
Acute risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals!
WARNING
Risk of injury!
If you do not adhere the safety advise adjoining this symbol, there is danger to life and health of individuals!
CAUTION
Hazard to individuals!
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to individuals!
Attention
Hazard to devices and environment
If you do not adhere the notice adjoining this symbol, there is obvious hazard to materials and environment.
Note
Note or pointer
This symbol indicates information that contributes to better understanding.
Foreword
6 C5240
1.3 Basic safety measures
Before the Industrial PC is switched off, software that is running must be properly closed. Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the
Industrial PC on and off.
Warning
Switch off all parts of the equipment, then uncouple the fieldbus
Before opening the housing, and whenever the Industrial PC is not being used for control purposes (such as during functional checks after a repair), all parts of the equipment must first be switched off, after which the Industrial PC is to be disconnected from the equipment.
Pulling out the fieldbus connection plug uncouples the PC (optional). Items of equipment that have been switched off must be secured against being switched on again.
The Industrial PC’s power supply unit must be supplied with 100V
AC
– 240 VAC. Optional a 24 VDC power
supply unit with UPS is available.
DANGER
Do not open the power supply unit while voltage is applied!
The supply voltage must be switched off before the power supply unit housing is opened.
Warning
Do not exchange any parts when under power
When components are being fitted or removed, the supply voltage must be switched off.
Fitting work on the Industrial PC can result in damage:
if metal objects such as screws or tools fall onto operating circuit boards.
if connecting cables internal to the PC are removed or inserted during
operation.
if plug-in cards are removed or inserted when the PC is switched on.
Foreword
C5240 7
1.4 Operator’s obligation to exercise diligence
The operator must ensure that
the product is only used as intended (see chapter Product Description)
the product is in a sound condition and in working order during operation
the product is operated, maintained and repaired only by suitably qualified and authorized
personnel
the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein
the operation manual is in good condition and complete, and always available for reference at the location of the product
Attention
Only trained persons may open the Industrial PC housing
The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC.
1.4.1 National regulations
Depending on the type of machine and plant in which the Industrial PC is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator. These regulations cover, amongst other things, the intervals between inspections of the controller. The operator must initiate such inspections in good time.
1.4.2 Procedure in the event of a fault
In the event of faults at the Industrial PC, the list in the section Troubleshooting can be used to determine the measures to be taken.
1.4.3 Operator requirements
Anyone who uses the Industrial PC must have read these operating instructions and must be familiar with all the functions of the software installed on the Industrial PC to which he has access.
Product Description
8 C5240
2 Product Description
2.1 Product overview
C5240 | 19-inch slide-in Industrial PC
The C5240 Industrial PC expands the C52xx Industrial PC series by a version with four height units and seven PCI and PCIe plug-in card slots in 24 V DC or 110…230 V AC versions. The basic configuration includes three 5¼-inch drive bays behind the front flap. As an option, three additional 5¼-inch drive bays are available ex-factory. It is designed for installation in a 19-inch rack and is equipped with components of the highest performance class according to the ATX standard.
A Beckhoff industrial motherboard is used with Intel® Celeron®, Pentium®, Core™ i3, i5 or i7 fourth, sixth or seventh generation processors. The seventh generation requires a Windows 10 64-bit operating system. With the fourth and sixth generation, Windows 7 32-bit or 64-bit can be used besides Windows 10.
The C5240 is ideally suited for use in machine and plant engineering, for example with TwinCAT automation software.
The Industrial PC offers the following benefits:
7-slot slide-in housing ATX for 19-inch racks, 4 rack units
all slots for full-length plug-in cards
lockable front flap
card holders
protection class: front side IP50, back side IP20
operating temperature 0…55 °C.