AEG-Electrolux EXS18GC6WI, EXS18GC6WE, EXS18GC4WE, EXS24GC4WI, EXS24GC4WE User Manual

...
0 (0)

user manual

Split Type Room Air Conditioner

Table of Contents

Congratulations ....................................................................

2

Safety Precautions ...............................................................

3

Product´s Description ...........................................................

5

Indoor Unit Display ...............................................................

6

Remote Control.....................................................................

6

Remote Control Description .................................................

7

Remote Control Display Indicators .......................................

9

First Use ...............................................................................

10

How to use the Remote Control............................................

10

How to use the Indoor Unit ...................................................

15

Emergency Operation ..........................................................

16

Optimal Operation ................................................................

16

Cleaning and Maintenance ..................................................

17

Operation Tips ......................................................................

19

Troubleshooting ...................................................................

20

Important Reminder

Keep the remote control where its signal can reach the receiver of the indoor unit.

When operate the air conditioner, make sure the remote control is pointing to the signal receiver of the indoor unit.

When the remote control sends out a signal, the symbol

will blink for about 1 second on the display of the remote control.

The indoor unit will acknowledge the signal with a beep when it receives the signal from the remote control.

Please press the button of the remote control and resend the signal if you did not hear a beep from the indoor unit.

1

Congratulations

Congratulations and thank you for choosing Electrolux split-type air conditioner. We are sure you will find your new air conditioner a pleasure to use.

Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions.

To avoid the risks that are always present when you use an electrical appliance, it is important that the air conditioner is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards.

We recommend that you keep this instruction booklet for future reference and pass it on to any future owners.

After unpacking the air conditioner please check it is not damaged. If in doubt, do not use the

air conditioner but contact your local Electrolux authrised service centre.

environmental tip

Information on disposal for users

Most of the packing materials are recyclable.

Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers.

If you wish to discard this air conditioner, please contact your local authorities and ask for the correct method of disposal.

caution

The air conditioner is not intended for use by young children or infirmed persons without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

Contact an authorised installer for installation of this air conditioner.

Contact an authorised service technician for repair or maintenance of this unit.

If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.

Installation work must be performed in accordance with the national wiring Standards by authorised personnel only.

Conditions of use

This appliance is intended to be used in household and similar applications such as:

Staff kitchen areas in shops, offices and other working environments.

Farm houses.

By clients in hotels, motels, and other residential type environments.

Bed and breakfast type environments.

Important notes

Contact an authorised installer for installation of this unit.

Contact an authorised service technician for repair or maintenance of this unit.

The socket oultet required to supply power must be connected and commissioned by a licenced contractor.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge,

unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Young children should be supervised to ensure that they do not play with the air conditioner.

If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.

Installation work must be performed in accordance with the national wiring

standards and the electricity suppliers service rules by authorised personnel only.

If the unit is to be moved to another location or disposed of, only a suitably qualified person is permitted to undertake such work.

Take care not to catch fingers on the fan blade when adjusting vertical louvers.

This air conditioner uses R22 or R410a refrigerant (Confirm before installation).

2

Safety precautions

Inside this manual you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips on page 20-21. If you review the chart of troubleshooting tips first, you may not need to call for service.

Meanings of symbols used in this manual are shown below:

caution

This indicates information concerning your personal safetyand how to avoid damaging the appliance.

tips and information

This symbol indicates tips and information about use of the appliance.

environmental tip

This symbol indicates tips and information about economical and ecological use of the appliance.

This symbol indicates never to do this.

Always do this.

Important notes:

1Do not operate unit with horizontal louvre inclosed position.

2Do not operate unit without the air filter.

warning

If you notice an unusal situation, such as a burning smell, please switch off the power to the air conditioner and contact an Electrolux service agent. If this abnormal status continues the air conditioner may be damaged or even cause electric shock or fire.

Do not operate the air conditioner with wet hands. This may cause electric shock.

Do not damage or cut off the power cord or other wires. If this occurs, please have it repaired or replaced by an accredited technician

Do not connect this air conditioner to a multi outlet powerboard.

Please switch off the power supply to the air conditioner if it is not to be used for an extended period. Otherwise, it will accumulate dust and may cause a fire.

Before cleaning the air conditioner, please disconnect the power supply in order to eliminate the possibility of electric shock.

The power supply should be matched with the air conditioner according to the installation manual. Air conditioners provided with a supply cord should be

connected directly to a power outlet with a suitable safety switch. Air conditioners that are hard wired must be connected to a suitable safety circuit breaker according to the installation manual.

Please ensure that the power supply to the air conditioner is stable and meets the requirements set out in the installation manual.

Always ensure the product is installed with appropriate earthing.

For safety, be sure to turn off the circuit breaker before performing any maintenance or cleaning or when the product is not used for an extended period of time. Accumulated dust may cause fire or electric shock.

3

Safety precautions caution

Select the most appropriate temperature. It can save electricity.

Do not keep windows and doors open for a long time during operation. It will result in insufficient performance.

Do not block the air inlet or outlet.

It will result in insufficient performance and cause malfunctions.

Keep combustible materials away from the units at least 1m. It may cause fire.

Do not step on the top of the outdoor unit or place heavy things on it.

It may cause damage or injury.

Do not attempt to repair the air conditioner by yourself. Incorrect repairs may cause electric shock or fire. Please contact your local authorised service centre.

Do not insert your hands or objects into the air inlet or outlet. It may cause injury.

Do not expose animals or plants directly to the air flow.

Do not use the unit for any other purpose, such as preserving food or drying clothes.

Do not splash water on the air conditioner. It may cause electric shock or malfunction.

Prior to Operation

1Contact an installation qualified for installation.

2Plug in the power plug properly.

3Do not use a damaged or non-standard power cord.

4Do not share the same outlet with other appliances.

5Do not use an extension cord.

6Do not start/stop operation by plugging / unplugging the power cord.

Usage

Exposure to direct airflow from the air conditioner for an extended period of time could be hazardous to your health.

Do not expose people, pets or plants to the direct airflow for an extended period.

Cleaning and maintenance

1When cleaning the unit, first make sure that the power and circuit breaker are turned off.

2Do not touch the metal parts of the unit when removing the filters. Injuries can occur when handling sharp metal edges.

3Do not use water to clean inside the air conditioner. Exposure to water may lead to possible electric shock.

Service

For repair and maintenance, contact your authorised service dealer.

4

AEG-Electrolux EXS18GC6WI, EXS18GC6WE, EXS18GC4WE, EXS24GC4WI, EXS24GC4WE User Manual

Product Description

Indoor Unit

2

Air inlet

1

 

13

3

4

5 Air Outlet 6

7

8

Outdoor Unit

9

Air inlet (rear)

Air inlet (side)

11

12

 

Mode

Light

Fan

Turbo

Healthy

Timer-On

 

Temp

Timer-Off

 

Clock

Swing

I feel

Eco

10 14

Air Outlet

15

Front panel

Digital display

Healthy air filter (behind the dust filter)

Pre-dust filter

Horizontal air louvers

Vertical air louvers

Cold plasma generator (if applicable) Manual control button

Remote control Remote control holder

Refrigerant pipe (if applicable) Drain hose (if applicable) Power cable (if applicable) Mounting plate

Connecting cable (if applicable)

Note: The above drawings are for explanation purpose only. Your air conditioner may be slightly different.

The actual shape shall prevail.

5

Indoor Unit Display

Signal receiver

I Feel indicator

It lights when I Feel function is activated.

Turbo indicator

Illuminates during Turbo operation.

Eco (Economy) indicator

Illuminates when ECO function is in operation.

Temperature indicator

Displays the temperature settings when the air conditioner is in operation.

Timer indicator

The indicator illuminates when Timer is set ON and/or OFF.

Swing indicator

It lights when the Swing function is activated.

Remote Control

How to use the Remote Control

Point the remote control to the signal receiver of indoor unit.

Make sure there is no obstacle that may interfere with the signal.

Location of the remote control

8m

 

Mode

Light

Fan

Turbo

Healthy

Timer-On

 

Temp

Timer-Off

 

Clock

Swing

I feel

Eco

• Keep the remote control where its signal can reach the receiver of the indoor unit (a maximum distance of 8m is allowed).

• When you select the timer operation, the remote control automatically transmits a signal to the indoor unit at the specified time.

If you keep the remote control in a position that hinders proper signal transmission, a time lag of up to 15 minutes may occur.

When the remote control sends out a signal, the

symbol will blink for about 1 second on the display. The indoor unit will acknowledge the signal with a beep when it receives an effective signal.

caution

The air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the indoor unit.

Prevent any liquid from falling into the remote control. Do not expose the remote control to direct sunlight or heat.

If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.

If other electrical appliances react to the remote control, either move these appliances or consult your local dealer.

Battery installation/replacement

Slide the battery compartment cover off and insert two new alkaline dry batteries

(2x AAA1.5Volt). Make sure that the polarity of

(+) or (-) is installed correctly.

Slide the battery compartment cover back on

tips and information

When changing batteries, do not use old or varied ones, otherwise, it may cause problems with the remote control.

If the remote control is not used for a long time, remove the batteries as old batteries may leak or corrode and damage the remote control.

The battery life during normal use is about six months.

If the remote control does not operate normally, please remove and refit the batteries. If abnormal operation continues, replace with new batteries.

6

Remote Control Description

Models with Cold-Plasma function

 

 

 

 

 

 

 

 

 

0RGH

/LJKW

 

 

 

 

 

+HDOWK\

 

 

)DQ

7XUER

 

 

 

 

 

 

7LPHU 2Q

 

7HPS

 

 

 

 

 

 

 

7LPHU 2II

 

&ORFN

 

 

 

 

 

 

 

 

 

 

6ZLQJ

, IHHO

(FR

 

 

 

 

 

 

 

 

 

 

ON/OFF Button

Press this button to turn the air conditioner ON or OFF.

Mode Button

By pressing this button, AUTO, DEHUMIDIFY, FAN, COOL, and HEAT (COOL only model has no HEAT feature) mode can be selected progressively.

AUTO mode is default while power on. Under AUTO mode, the initial value is 23°C;

Under HEAT mode, the initial value is 28°C; Under other modes, the initial value is 25°C.

AUTO

DEHUMIDIFY

FAN

COOL

HEAT

Light Button

Press this button to switch the indicating lights of the indoor unit ON or OFF.

The normal condition at start up is ON.

Fan Button

By pressing this button, Auto, Low, Medium and High speed can be progressively selected.

When the unit is turned on, Auto fan speed is the default.

In DEHUMIDIFY mode, the fan speed is fixed at

Low speed.

Turbo Button

Press this button in COOL or HEAT mode to put the fan into the high speed Turbo mode and the air conditoner will work at maximum power.

Press again to cancel this function.

Healthy Button

Press this button to turn the Cold-Plasma function ON or OFF.

+ X-Fan Buttons

Press the Turbo button and Healthy button at the same time (for 3 seconds), the X-FAN function will be activated. After the unit is turned off the indoor fan will continue operation for 10 minutes to dry the indoor unit prevent from bacteria and mildew growing.

Timer On Button

Press this button to set the start time.

Timer Off Button

Press this button to set the stop time.

Swing Button:

Press this button, the louver will swing up and down automatically. Press again to cancel it and the louver will stay at its last position.

I Feel Button:

Press this button, the remote control will send the temperature information to the indoor unit every 2 minutes. The unit will operate to reach the set temperature at the location of remote control. Presss again to cancel this function.

Control Button:

Forward Backward

Press the button to increase the temperature setting.

Press the button to decrease the temperature setting.

In Timer On/Off or Clock functions, use these buttons to set the clock or timer adjustment.

Clock Button:

Press this button and the Clock symbol will blink. You can press Control buttons and to set the time you want.

Temp (Temperature) Button

Press this button to change the remote control display of the set temperature to the room temperature.

Eco (Economy) Button

Press this button to start the Eco operation. This is ideal for the users to use while sleeping. Press again to cancel the function.

7

Loading...
+ 16 hidden pages