Auto-Drain Rain Gauge: RG333

Publication Number 39140712 01-566
- 1 -
Global Water
800-876-1172 globalw.com
Congratulations on your purchase of the Global Water RG333 Auto-Drain Rain Gauge. This instrument has been quality tested and approved for providing accurate and reliable rain gauge measurements. We are confident that you will find the RG333 to be a valuable asset for your application. Should you require assistance, our technical staff will be happy to help.

Table of Contents

I. Checklist Page 3 II. Inspection III. Auto-Drain Rain Gauge Installation IV. Auto-Drain Rain Gauge Set Up and Use V. Maintenance VI. Troubleshooting VII. Warranty
* Copyright Global Water Instrumentatio n, I nc. 2012
6
3
4
4
4
5
- 2 -

I. RG333 Checklist

a. Auto-Drain Rain Gauge b. RG333 Manual c. 2 AA batteries (inside rain gauge)

II. Inspection

a. Your RG333 unit was carefully inspected and certified by our Quality
Assurance Team before shipping. If any signific ant damage has occurred during shipping, please not ify Global Water Instrumentation, Inc. and file a claim with the carrier inv olv ed.
Use the checklist to ensure that you hav e r ec eived every thing needed to operate the RG333.
.
Global Water
800-876-1172 globalw.com
- 3 -
Global Water
800-876-1172 globalw.com

III. Auto-Drain Rain Gauge Installation

a. The Auto-Drain Rain Gauge requires a clear an unobstructed
mounting location to obtain accurate r ainfall readings. There are two holes drilled through the backing plate t hat may be used to mount the Rain Gauge to a post.

IV. Auto-Drain Rain Gauge Set Up and Use

a. The Hours knob can be used to change how often the rain gauge
empties. Set the knob to your specific applicat ion. (Usually 24 hours)
b. The Functions knob has 3 settings:
1. Off: When not in use
2. Drain: Manually Empty
3. Auto: Drains per the Hours settings
c. Once the Hours and Function knobs hav e been set, verify the RG333
is mounted vertically, and there is no obst r uc tion above the opening.

V. Maintenance

a. The funnel and Auto-Drain Rain Gauge mechanism should be cleaned
periodically. An accumulation of dirt , bugs, etc. in the Auto-Drain Rain Gauge funnel will adversely affec t t he r eadings . If necessary use a bristle brush and flush with fresh water.
b. Replace the unit’s batteries annually. The Rain Gauge comes with two
AA size alkaline batteries. To access t he batteries, unscrew the Phillips head screw, located at the bot tom of the unit. Remove cover and replace batteries.
WARNING: Removing the batteries will reset the Rain G auge’s A uto function.
- 4 -

VI. Trouble Shooting

Issue: Rain Gauge not op er a ti ng correctly
a. Repeat set up procedure. b. Check battery voltage. Other issues
c. Call us for tech support: 800-876-1172 or ( 979) 690-5560 (many
problems can be solved over the phone). Fax: (979) 690-0440 or Email: globalw@globalw.com.
Be prepared to describe the problem you are experiencing including specific details of the application and installation and any additional pertinent information.
d. In the event that the equipment needs to be returned to the factory for
any reason, please call to obtain a RMA # (Return Material Authorization). Do not return items without a RMA # displayed on the outside of the package.
Clean and decontaminate the RG 333 w hen necessar y . Include a written statement describing the problems. Send the package with shipping prepaid to our factory address. Insure
your shipment, as the warranty does not c ov er damage incur r ed dur ing transit.
e. When calling for tech support, please have the following information
ready;
1. Model #.
2. Unit serial number.
3. P.O.# the equipment was purchased on.
4. Our sales number or the invoice number.
5. Repair instructions and/or specific problems relating to the product.
Global Water
800-876-1172 globalw.com
- 5 -

VII. Warranty

a. Global Water Instrumentation, Inc. warrants that its produc ts are free
from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory. Global Water’s obligations under this w ar r anty are limited to, at Global Water’s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall Global Water ’s liability exceed the products original purchase price. This w ar r anty does not apply to any equipment that has been repaired or altered, ex c ept by Global Water Instrumentation, Inc., or which has been s ubjec t to misuse, negligence or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warr anty of merchantability.
b. The warranty begins on the date of your invoice.
Global Water
800-876-1172 globalw.com
- 6 -