For the owner and heating engineer
Operating and Installation Manual
VRT 360f
Room temperature thermostat
VRT 360f
GB
Contents |
|
|
|
|
Inhaltsverzeichnis |
|
|
Setting the operating modes |
9 |
|
4.1 |
|||
|
|
4.2 |
Setting the current day and |
|
Notes on the documentation . . . . . . |
4 |
|
time ................................................... |
12 |
Storage of the documents.................... |
4 |
4.3 |
Setting timer programmes .......... |
13 |
Symbols used........................................... |
4 |
4.4 |
Setting the room temperature ... |
16 |
|
|
4.5 |
Setting the hot water |
|
Safety . . . . . . . . . . . . . . . . . . . . . . . . . |
5 |
|
temperature .................................... |
18 |
|
|
4.6 |
Activating special functions........ |
19 |
Operating manual. . . . . . . . . . . . . . . . |
6 |
4.7 |
Info level........................................... |
22 |
|
|
4.8 |
Changing the battery.................... |
23 |
1 Overview of the equipment . . . . . |
6 |
|
|
|
|
|
5 |
Manufacturer’s warranty and |
|
2 Overview of the display . . . . . . . |
7 |
|
liability . . . . . . . . . . . . . . . . . . . . |
25 |
3 Description of the appliance . . . |
8 |
6 |
Recycling and disposal. . . . . . . . |
25 |
4 Operation. . . . . . . . . . . . . . . . . . . |
8 |
|
|
|
2 |
|
|
Operating and installation manual VRT 360f |
Installation instructions . . . . . . . . . .27
7Notes on the installation and
|
operation . . . . . . . . . . . . . . . . . . . |
27 |
7.1 |
CE label............................................. |
27 |
7.2 |
Intended use.................................... |
28 |
8Safety instructions and regulati-
|
ons . . . . . . . . . . . . . . . . . . . . . . . . |
29 |
8.1 |
Safety instructions ........................ |
29 |
8.2 |
Regulations...................................... |
30 |
9 |
Installation . . . . . . . . . . . . . . . . . |
31 |
9.1 |
Place of installation....................... |
31 |
9.2 |
Fitting the receiver........................ |
31 |
9.3 |
Mounting the room temperature |
|
|
thermostat....................................... |
33 |
|
|
Contents |
10 |
Electrical installation. . . . |
. . . . .35 |
10.1 |
Connecting the receiver............... |
35 |
11 |
Start-up. . . . . . . . . . . . . . . |
. . . . .36 |
11.1 |
Installer level................................... |
37 |
11.2 |
Service/diagnostics level.............. |
41 |
11.3 |
Handing over the appliance to |
|
|
the owner......................................... |
43 |
12 |
Troubleshooting . . . . . . . . |
. . . . .44 |
13 |
Technical data. . . . . . . . . . |
. . . . .45 |
14 |
Vaillant Service . . . . . . . . |
. . . . .46 |
Operating and installation manual |
VRT 360f |
GB |
3 |
|
|
|
|
Notes on the documentation
Notes on the documentation
The following information is intended to help you throughout the entire documentation.
Other documents apply in combination with this installation and operation manual.
We accept no liability for any damage caused by failure to observe these instructions.
Storage of the documents
Please pass on this operating and installation manual to the owner of the system in order for him/her to store it so that it is available whenever it is required.
Symbols used
Please observe the safety instructions in this manual for the installation of the appliance.
Danger!
Immediate risk of serious injury or death
Caution!
Potentially dangerous situation for the product and environment.
4 |
Operating and installation manual VRT 360f |
|
Notes on the documentation, safety |
|
Safety |
Note! |
|
Useful information and |
|
instructions. |
The room temperature thermostat must |
|
be installed by a suitably qualified |
• Symbol for a necessary task |
heating engineer, who is responsible for |
|
adhering to the existing standards and |
|
regulations. |
|
We accept no liability for any damage |
|
caused by failure to observe these |
|
instructions. |
Operating and installation manual |
VRT 360f |
GB |
5 |
|
|
|
|
1 Overview of the device
Operating manual
1Overview of the equipment
1 |
2 |
Abb. 1.1 Overview of equipment
6
Key
1Display
2 Dial (turn and click)
IInfo button
F Special functions button
P Programming key/installer level
Operating manual |
VRT 360f |
Overview of the display 2
2Overview of the display
11 |
1 |
|
|
||
10 |
2 |
|
9 |
3 |
|
4 |
||
|
||
8 |
5 |
|
|
||
7 |
|
|
|
6 |
Fig. 2.1 Overview of the display
Key
1Installer level and Service/Diagnosis level (Chapter 11.1)
2 Info level (see 4.7)
3 Hot water symbol
4 Circulation pump symbol
5 Heating circuit symbol
6 Time/temperature display
7 Days of the week
8 Actual temperature
9 Operating modes (see 4.1)
10Special functions (see 4.6)
11Setting timer programmes (see 4.3)
Operating manual |
VRT 360f |
GB 7
3 Device description, 4 Operation
3Description of the appliance
The VRT 360f is a programmable room temperature thermostat with weekly programme for heating, hot water and circulation pump for connection to Vaillant heating equipment with eBus. The connection between the room temperature thermostat and the heating unit is by radio link.
The VRT 360f enables you to specify the room temperature using heating programs. In addition, you can select special functions such as the party function, and control the timed
8
operation of a boiler and a circulation pump.
4Operation
The operating principle is based on the three buttons and an dial (Vaillant "turn and click“ operating concept).
The display normally shows the current operating mode (e.g. ), or, if activated, the special function and the current room temperature, the day of the week, the time and the symbol for heating, hot water and/or the circulation pump, depending on which is requested.
Operating manual |
VRT 360f |
Operation 4
4.1 Setting the operating modes
Table 4.1 provides you with an overview of the operating modes you can select. The selected operating mode affects the timer programmes both for heating and for hot water and the circulation pump.
•When the room temperature thermostat is in normal display mode. press the dial once – the symbol for the selected mode flashes in the display.
•Turn the dial until the desired operating mode appears on the
display.
The display switches back to normal mode after five seconds.
Operating manual |
VRT 360f |
GB 9
4 Operation
Symbol |
Meaning |
|
|
|
|
|
|
|
|
|
Heating |
Hot water |
|
|
|
|
|
|
|
|
Automatic: |
The operation of the hot water |
|
|
|
The operation of the heating circuit changes between |
storage cylinder/circulation |
|
|
|
the operation modes Heating and Energy Saving |
pump changes between |
|
|
|
. The heating circuit symbol is displayed if a heating |
heating/ON and OFF |
|
|
|
requirement is detected. |
depending upon the time |
|
|
|
Heating: |
programme set on the room |
|
|
|
The heating circuit is operated according to the |
temperature thermostat. |
|
|
|
room temperature, regardless of the programme set |
The hot water symbol and the |
|
|
|
on the room temperature thermostat. The heating |
circulation pump symbol are |
|
|
|
circuit symbol is displayed if a heating requirement is |
displayed if the time window |
|
|
|
detected. |
is active. |
|
|
|
Energy Saving: |
|
|
|
|
The heating circuit is operated according to the |
|
|
|
|
energy saving temperature "ECO“, regardless of the |
|
|
|
|
programme set on the room temperature thermostat. |
|
|
|
|
The heating circuit symbol is displayed if a heating |
|
|
|
|
requirement is detected. |
|
|
|
|
|
|
|
|
Table 4.1 Operating modes |
|
|
|
|
10 |
|
Operating manual |
VRT 360f |
|
|
Operation 4 |
|
|
|
Symbol |
Meaning |
|
|
|
|
|
Heating |
Hot water |
|
|
|
|
Off: |
The boiler is not heated up, regardless of |
|
The heating circuit is off, provided that |
the set timer programme. The circulation |
|
the frost protection function (if the room |
pump is switched off. The hot water |
|
temperature is below 5°C) |
and circulation pump symbols are not |
|
is not activated. |
displayed. |
|
If the frost protection function is activated, |
|
|
the heating circuit symbol is displayed. |
|
Table 4.1 Operating modes (contd.) |
|
Operating manual |
VRT 360f |
GB 11
4 Operation
4.2Setting the current day and • Press the dial. The hours start flashing.
time
To set the current time and day of the week with the display in normal mode, you must perform the following steps:
•Press the dial until a day of the week starts flashing.
•Turn the dial until you see the current day of the week.
MO = Monday TU = Tuesday WE = Wednesday TH = Thursday FR = Friday
SA = Saturday SU = Sunday
•Turn the dial until you see the current hour.
•Press the dial. The minutes start flashing.
•Turn the dial until you see the current
minute.
The display switches back to normal mode after five seconds.
If the calendar is activated on the installer level (see 11.1), you can set the day, month and year in the same way after you set the time. This allows automatic switching from winter to summer time.
12 |
Operating manual |
VRT 360f |
Operation 4
4.3 Setting timer programmes |
Table 4.2 Default heating, hot water and |
||||
circulation pump programmes |
|||||
The room temperature thermostat is |
|||||
|
|||||
equipped with a basic program (see table |
|
||||
4.2). |
|
|
|
You can adapt the default programmes |
|
|
|
|
|
to suit your needs. There are six steps to |
|
Time |
Current day |
Start |
End |
setting the times you want. |
|
window |
/ Block of |
time |
time |
1. Press the programming button P |
|
|
days |
|
|
||
|
|
|
2.Select the timer programme (heating, |
||
|
|
|
|
||
H1 |
M0-FR |
6:00 |
22:00 |
||
hot water or circulation pump) |
|||||
H2 |
— |
— |
— |
||
3.Select the time window |
|||||
H3 |
— |
— |
— |
||
4.Select the current day or week block |
|||||
H1 |
SA |
7:30 |
23:30 |
||
|
|
|
|
5.Set the start time. |
|
H2 |
— |
— |
— |
||
|
|
|
|
6.Set the end time. |
|
H3 |
— |
— |
— |
||
|
|
|
|
|
|
H1 |
SU |
7:30 |
22:00 |
|
|
|
|
|
|
|
|
H2 |
— |
— |
— |
|
|
|
|
|
|
|
|
H3 |
— |
— |
— |
|
|
|
|
|
|
|
Operating manual |
VRT 360f |
GB 13
4 Operation |
|
|
|
|
|
|
|
|
|
You can define three time windows for |
|
Display |
Required steps |
|
each day. |
|
|
|
Press the programming |
|
|
|
||
When you press the P button the display |
|
|
|
button P. The cursor (black |
|
|
|
triangle) marks the value |
|
returns to basic mode. |
|
|
|
|
|
|
|
which can be changed ( ), |
|
The table below illustrates the individual |
|
|
|
which also flashes. |
steps again, using the example of the hot |
|
|
|
Turn the dial until the tap |
|
|
|
||
water timer programme. If you want to |
|
|
|
symbol appears. |
|
|
|
|
|
change the timer programme for heating |
|
|
|
|
|
|
|
Press the dial. The cursor |
|
|
|
|
||
or the circulation pump, after pressing |
|
|
|
|
|
|
|
marks the adjustable value |
|
the programming button P, select the |
|
|
|
(H1), which also flashes. |
corresponding symbol (heating circuit or |
|
|
|
Select the desired time |
circulation pump) and continue as shown |
|
|
|
window by turning the dial. |
|
|
|
Settings: H1, H2, H3 |
|
|
|
|
||
in the example. |
|
|
|
|
|
|
|
|
|
|
|
|
|
14 |
Operating manual |
VRT 360f |
|
Display |
Required steps |
|||
|
|
|
|
|
|
|
|
|
|
|
Press the dial. The cursor |
|
|
|
|
|
|
|
|
|
|
|
marks the week block |
|
|
|
|
|
display, which also flashes. |
|
|
|
|
|
Select a block programme |
|
|
|
|
|
or a single day of the week |
|
|
|
|
|
by turning the dial. |
|
|
|
|
|
|
|
|
|
|
|
Settings: |
|
|
|
|
|
MO - SU |
|
|
|
|
|
MO - FR |
|
|
|
|
|
SA - SU |
|
|
|
|
|
MO = Monday |
|
|
|
|
|
TU = Tuesday |
|
|
|
|
|
WE = Wednesday |
|
|
|
|
|
TH = Thursday |
|
|
|
|
|
FR = Friday |
|
|
|
|
|
SA = Saturday |
|
|
|
|
|
SU = Sunday |
|
|
|
|
|
|
|
|
|
Operation 4 |
|
|
|
|
|
Display |
Required steps |
|
|
|
|
|
|
|
|
Press the dial. The cursor |
|
|
|
|
|
|
|
marks the start time and the |
|
|
|
hour display flashes. |
|
|
|
Select the start time by |
|
|
|
turning the dial. Press |
|
|
|
the dial again to set the |
|
|
|
|
|
|
|
minutes. |
|
|
|
|
|
|
|
Press the dial. The cursor |
|
|
|
|
|
|
|
marks the end time and the |
|
|
|
hour display flashes. |
|
|
|
Select the end time by |
|
|
|
turning the dial. Press |
|
|
|
the dial again to set the |
|
|
|
|
|
|
|
minutes. |
|
|
|
|
Table 4.3 Setting time windows