Vaillant VRT 360f Operation Manual

0 (0)
Vaillant VRT 360f Operation Manual

For the owner and heating engineer

Operating and Installation Manual

VRT 360f

Room temperature thermostat

VRT 360f

GB

Contents

 

 

 

 

Inhaltsverzeichnis

 

 

Setting the operating modes

9

 

4.1

 

 

4.2

Setting the current day and

 

Notes on the documentation . . . . . .

4

 

time ...................................................

12

Storage of the documents....................

4

4.3

Setting timer programmes ..........

13

Symbols used...........................................

4

4.4

Setting the room temperature ...

16

 

 

4.5

Setting the hot water

 

Safety . . . . . . . . . . . . . . . . . . . . . . . . .

5

 

temperature ....................................

18

 

 

4.6

Activating special functions........

19

Operating manual. . . . . . . . . . . . . . . .

6

4.7

Info level...........................................

22

 

 

4.8

Changing the battery....................

23

1 Overview of the equipment . . . . .

6

 

 

 

 

 

5

Manufacturer’s warranty and

 

2 Overview of the display . . . . . . .

7

 

liability . . . . . . . . . . . . . . . . . . . .

25

3 Description of the appliance . . .

8

6

Recycling and disposal. . . . . . . .

25

4 Operation. . . . . . . . . . . . . . . . . . .

8

 

 

 

2

 

 

Operating and installation manual VRT 360f

Installation instructions . . . . . . . . . .27

7Notes on the installation and

 

operation . . . . . . . . . . . . . . . . . . .

27

7.1

CE label.............................................

27

7.2

Intended use....................................

28

8Safety instructions and regulati-

 

ons . . . . . . . . . . . . . . . . . . . . . . . .

29

8.1

Safety instructions ........................

29

8.2

Regulations......................................

30

9

Installation . . . . . . . . . . . . . . . . .

31

9.1

Place of installation.......................

31

9.2

Fitting the receiver........................

31

9.3

Mounting the room temperature

 

 

thermostat.......................................

33

 

 

Contents

10

Electrical installation. . . .

. . . . .35

10.1

Connecting the receiver...............

35

11

Start-up. . . . . . . . . . . . . . .

. . . . .36

11.1

Installer level...................................

37

11.2

Service/diagnostics level..............

41

11.3

Handing over the appliance to

 

the owner.........................................

43

12

Troubleshooting . . . . . . . .

. . . . .44

13

Technical data. . . . . . . . . .

. . . . .45

14

Vaillant Service . . . . . . . .

. . . . .46

Operating and installation manual

VRT 360f

GB

3

 

 

 

 

Notes on the documentation

Notes on the documentation

The following information is intended to help you throughout the entire documentation.

Other documents apply in combination with this installation and operation manual.

We accept no liability for any damage caused by failure to observe these instructions.

Storage of the documents

Please pass on this operating and installation manual to the owner of the system in order for him/her to store it so that it is available whenever it is required.

Symbols used

Please observe the safety instructions in this manual for the installation of the appliance.

Danger!

Immediate risk of serious injury or death

Caution!

Potentially dangerous situation for the product and environment.

4

Operating and installation manual VRT 360f

 

Notes on the documentation, safety

 

Safety

Note!

Useful information and

 

instructions.

The room temperature thermostat must

 

be installed by a suitably qualified

• Symbol for a necessary task

heating engineer, who is responsible for

 

adhering to the existing standards and

 

regulations.

 

We accept no liability for any damage

 

caused by failure to observe these

 

instructions.

Operating and installation manual

VRT 360f

GB

5

 

 

 

 

1 Overview of the device

Operating manual

1Overview of the equipment

1

2

Abb. 1.1 Overview of equipment

6

Key

1Display

2 Dial (turn and click)

IInfo button

F Special functions button

P Programming key/installer level

Operating manual

VRT 360f

Overview of the display 2

2Overview of the display

11

1

 

10

2

9

3

4

 

8

5

 

7

 

 

6

Fig. 2.1 Overview of the display

Key

1Installer level and Service/Diagnosis level (Chapter 11.1)

2 Info level (see 4.7)

3 Hot water symbol

4 Circulation pump symbol

5 Heating circuit symbol

6 Time/temperature display

7 Days of the week

8 Actual temperature

9 Operating modes (see 4.1)

10Special functions (see 4.6)

11Setting timer programmes (see 4.3)

Operating manual

VRT 360f

GB 7

3 Device description, 4 Operation

3Description of the appliance

The VRT 360f is a programmable room temperature thermostat with weekly programme for heating, hot water and circulation pump for connection to Vaillant heating equipment with eBus. The connection between the room temperature thermostat and the heating unit is by radio link.

The VRT 360f enables you to specify the room temperature using heating programs. In addition, you can select special functions such as the party function, and control the timed

8

operation of a boiler and a circulation pump.

4Operation

The operating principle is based on the three buttons and an dial (Vaillant "turn and click“ operating concept).

The display normally shows the current operating mode (e.g. ), or, if activated, the special function and the current room temperature, the day of the week, the time and the symbol for heating, hot water and/or the circulation pump, depending on which is requested.

Operating manual

VRT 360f

Operation 4

4.1 Setting the operating modes

Table 4.1 provides you with an overview of the operating modes you can select. The selected operating mode affects the timer programmes both for heating and for hot water and the circulation pump.

When the room temperature thermostat is in normal display mode. press the dial once – the symbol for the selected mode flashes in the display.

Turn the dial until the desired operating mode appears on the

display.

The display switches back to normal mode after five seconds.

Operating manual

VRT 360f

GB 9

4 Operation

Symbol

Meaning

 

 

 

 

 

 

 

 

 

Heating

Hot water

 

 

 

 

 

 

 

 

Automatic:

The operation of the hot water

 

 

 

The operation of the heating circuit changes between

storage cylinder/circulation

 

 

 

the operation modes Heating and Energy Saving

pump changes between

 

 

 

. The heating circuit symbol is displayed if a heating

heating/ON and OFF

 

 

 

requirement is detected.

depending upon the time

 

 

 

Heating:

programme set on the room

 

 

 

The heating circuit is operated according to the

temperature thermostat.

 

 

 

room temperature, regardless of the programme set

The hot water symbol and the

 

 

 

on the room temperature thermostat. The heating

circulation pump symbol are

 

 

 

circuit symbol is displayed if a heating requirement is

displayed if the time window

 

 

 

detected.

is active.

 

 

 

Energy Saving:

 

 

 

 

The heating circuit is operated according to the

 

 

 

 

energy saving temperature "ECO“, regardless of the

 

 

 

 

programme set on the room temperature thermostat.

 

 

 

 

The heating circuit symbol is displayed if a heating

 

 

 

 

requirement is detected.

 

 

 

 

 

 

 

 

Table 4.1 Operating modes

 

 

 

10

 

Operating manual

VRT 360f

 

 

Operation 4

 

 

 

Symbol

Meaning

 

 

 

 

 

Heating

Hot water

 

 

 

 

Off:

The boiler is not heated up, regardless of

 

The heating circuit is off, provided that

the set timer programme. The circulation

 

the frost protection function (if the room

pump is switched off. The hot water

 

temperature is below 5°C)

and circulation pump symbols are not

 

is not activated.

displayed.

 

If the frost protection function is activated,

 

 

the heating circuit symbol is displayed.

 

Table 4.1 Operating modes (contd.)

 

Operating manual

VRT 360f

GB 11

4 Operation

4.2Setting the current day and • Press the dial. The hours start flashing.

time

To set the current time and day of the week with the display in normal mode, you must perform the following steps:

Press the dial until a day of the week starts flashing.

Turn the dial until you see the current day of the week.

MO = Monday TU = Tuesday WE = Wednesday TH = Thursday FR = Friday

SA = Saturday SU = Sunday

Turn the dial until you see the current hour.

Press the dial. The minutes start flashing.

Turn the dial until you see the current

minute.

The display switches back to normal mode after five seconds.

If the calendar is activated on the installer level (see 11.1), you can set the day, month and year in the same way after you set the time. This allows automatic switching from winter to summer time.

12

Operating manual

VRT 360f

Operation 4

4.3 Setting timer programmes

Table 4.2 Default heating, hot water and

circulation pump programmes

The room temperature thermostat is

 

equipped with a basic program (see table

 

4.2).

 

 

 

You can adapt the default programmes

 

 

 

 

to suit your needs. There are six steps to

Time

Current day

Start

End

setting the times you want.

window

/ Block of

time

time

1. Press the programming button P

 

days

 

 

 

 

 

2.Select the timer programme (heating,

 

 

 

 

H1

M0-FR

6:00

22:00

hot water or circulation pump)

H2

3.Select the time window

H3

4.Select the current day or week block

H1

SA

7:30

23:30

 

 

 

 

5.Set the start time.

H2

 

 

 

 

6.Set the end time.

H3

 

 

 

 

 

H1

SU

7:30

22:00

 

 

 

 

 

 

H2

 

 

 

 

 

 

H3

 

 

 

 

 

 

Operating manual

VRT 360f

GB 13

4 Operation

 

 

 

 

 

 

 

 

 

You can define three time windows for

 

Display

Required steps

each day.

 

 

 

Press the programming

 

 

 

When you press the P button the display

 

 

 

button P. The cursor (black

 

 

 

triangle) marks the value

returns to basic mode.

 

 

 

 

 

 

which can be changed ( ),

The table below illustrates the individual

 

 

 

which also flashes.

steps again, using the example of the hot

 

 

 

Turn the dial until the tap

 

 

 

water timer programme. If you want to

 

 

 

symbol appears.

 

 

 

 

change the timer programme for heating

 

 

 

 

 

 

 

Press the dial. The cursor

 

 

 

or the circulation pump, after pressing

 

 

 

 

 

 

marks the adjustable value

the programming button P, select the

 

 

 

(H1), which also flashes.

corresponding symbol (heating circuit or

 

 

 

Select the desired time

circulation pump) and continue as shown

 

 

 

window by turning the dial.

 

 

 

Settings: H1, H2, H3

 

 

 

in the example.

 

 

 

 

 

 

 

 

 

 

 

14

Operating manual

VRT 360f

 

Display

Required steps

 

 

 

 

 

 

 

 

 

 

 

Press the dial. The cursor

 

 

 

 

 

 

 

 

 

 

marks the week block

 

 

 

 

 

display, which also flashes.

 

 

 

 

 

Select a block programme

 

 

 

 

 

or a single day of the week

 

 

 

 

 

by turning the dial.

 

 

 

 

 

 

 

 

 

 

Settings:

 

 

 

 

 

MO - SU

 

 

 

 

 

MO - FR

 

 

 

 

 

SA - SU

 

 

 

 

 

MO = Monday

 

 

 

 

 

TU = Tuesday

 

 

 

 

 

WE = Wednesday

 

 

 

 

 

TH = Thursday

 

 

 

 

 

FR = Friday

 

 

 

 

 

SA = Saturday

 

 

 

 

 

SU = Sunday

 

 

 

 

 

 

 

 

 

Operation 4

 

 

 

 

 

Display

Required steps

 

 

 

 

 

 

 

Press the dial. The cursor

 

 

 

 

 

 

marks the start time and the

 

 

 

hour display flashes.

 

 

 

Select the start time by

 

 

 

turning the dial. Press

 

 

 

the dial again to set the

 

 

 

 

 

 

minutes.

 

 

 

 

 

 

 

Press the dial. The cursor

 

 

 

 

 

 

marks the end time and the

 

 

 

hour display flashes.

 

 

 

Select the end time by

 

 

 

turning the dial. Press

 

 

 

the dial again to set the

 

 

 

 

 

 

minutes.

 

 

 

 

Table 4.3 Setting time windows

Operating manual

VRT 360f

GB 15

Loading...
+ 33 hidden pages