Sirona C2+ Quick user manual

AMALG
DESINF
S
0
A
RPM
6196369.fm Seite 1 Montag, 5. November 2007 4:55 16
Overview image
5
3
SAN
10
8
109
21
3
11
1010
Dear Customer,
You can use these brief operating instructions to quickly find the most important control procedures and functions of your dental treatment center.
However, they do not describe all of its functions. Therefore, they cannot replace the full operating instructions of your dental treatment center with its many important descriptions and warnings.
Care and cleaning of the treatment center are described thoroughly in the doc­ument entitled "Care and Cleaning by the Practice Team". A quick overview of the required measures is provided in a document entitled "Care and Cleaning Plan for Treatment Centers".
+
Your C2
Team
1
ON
Unit main switch
During power-up, the treatment center automati­cally performs a self-test.
OFF
ª After 20 seconds, the “READY“ reading
appears on the display.
6
7
S
0
1
2
L
102104
+
C2
40
100
30
75
SS
00
20
50
11
Mode
10
22
+
25
25
A/B
0.2
rpmx1000
1
1012
18
101
106
2
Position 1 Position 2 Position 3 Position 4 Position 5 Position 6
SPRAYVIT L Motor Motor Motor Highspeed
3
Position 1 Position 2 Pos it io n 3 Po sition 4
Mini L.E.D. SPRAYVIT L Suction handpiece Saliva ejector
3. Suction hose
DE instrument positions
handpiece
Highspeed handpiece
Highspeed
handpiece
on the side of the dentist element
Camera
Highspeed handpiece
SIROSONIC L
Mini L.E.D. Mini L.E.D.
AE instrument positions
SIROSONIC L
SIROTOM
Camera
10
4 7
1
A
RPM
2
Mode
1 Display for indicating unit status
1
AMALG
DESINFAB
RPM
+
AMALG appears when the amalgam rotor needs to be replaced.
DESINF starts flashing when DENTOSEPT P must be refilled.
40
100
30
75
20
50
3 4 5
10
25
0.2
rpm x 1000
1
A/B
A appears when user A is selected. B appears when user B is selected.
2 Mode key
2
Mode key with +/– keys for programming basic settings.
You can go on to the next basic setting dialog by repeatedly pressing the Mode key.
You can also use the functions directly once they have been selected:
Intensity of the instrument lights Intensity of the operation light Tumbler filling time Cuspidor flushing time
3 Main functions – dark blue keys
3
Quick setting keys for instrument intensity and
40
30
20
10
0.2
rpm x 1000
10040100
speed for:
Electric motors Ultrasonic scalers
75
HF electrosurgery
If you press a key for less than 0.5 s, the value indi-
50
cated next to that key appears on the display).
To set intermediate values, keep the key pressed
25
longer than 0.5 s.
1
+/ keys to set the following
A
INSTR. LIGHT
4 Additional functions – light blue keys
4
Control panel, dentist element Control panel, assistant element
You cannot switch users after picking up an instrument.
X-ray image viewer ON/OFF
Also WHITE SCREEN activation for video option
Composite key ON/OFF
for SIROLUX operation light, reduced light intensity < composite materials
SIROLUX operation light ON/OFF
for normal light intensity > 24,000 lux
Pressing this key for a while displays the light intensity settings dialog: OPERATING LIGHT
Tumbler filling
Pressing this key for a while displays the settings dialog: CUP FILL TIMER
Cuspidor flushing
Pressing this key for a while displays the settings dialog: BOWL FLUSH TIMER
Freely selectable function
e.g. call key, always functions as a button (con­nected by the service engineer)
Freely selectable function
The function can be preset as a button or switch in the Mode dialog.
(Connected by the service engineer)
for manual chair settings:
Move headrest out/in
Tilt headrest backward or forward.
Tilt backrest backward or forward.
Height adjustment down/up
In addition to the previously described functions, the keys of the dentist element also have functions in connection with the video option. They are described in section .
8,000 lux for processing
12
11
SS
%
SS
00
22
A/B
If the cursor is in the intensity setting block, the intensity can also be set by moving the cursor back and forth with the foot switch.
Spray ON/OFF
on burr drives
Chip blower
on burr drives
Counterclockwise rotation
for electric motor
Instrument light ON/OFF
Pressing this key for a while displays the light intensity settings dialog.
Mouth rinsing position chair program
with last position memory function
Programmable cuspidor flushing and/or tumbler filling.
Chair program 0
Entry/exit position (freely programmable)
Chair programs 1 and 2
(freely programmable)
The four program keys are also used for reprogramming the chair programs.
Preselection of user A or B
All instruments must be in place.
A
OPERATING LIGHT
A
CUP FILL TIMER
A
BOWL FLUSH TIMER
5
5 Chair functions – gray keys
6 Additional functions of the control panel video keys
6
%
5
6
Programming chair positions
The four factory-set programs can be changed individually by users A and B (observe the dis-
SS
11
00
22
play).
Programs 1 and 2 Entry/exit program 0 Mouth rinsing program S
¾ You can move the chair to the desired treat-
ment position by pressing the corresponding chair function key.
¾ To have the SIROLUX FANTASTIC opera-
tion light switch on or remain off when the chair reaches the programmed treatment position, you must switch the lamp ON or OFF now. This setting is then also pro­grammed.
¾ Now move the dentist element to the desired
treatment position by hand.
¾ To save the program settings, press the
desired program key for approx. 3 seconds.
ª An acoustic signal sounds and the LED in
the corresponding key lights up.
Saving instrument functions
The factory-set instrument programs can be changed individually by user A and user B.
¾ Select the corresponding user, i.e. A or B,
pick up an instrument and set it according to your wishes.
40
100
A/B
Example for electric motor:
40,000 rpm CW rotation with cooling spray with instrument light
¾ To save the settings, press key A/B for a
while (approx. 3 s).
ª An audible signal sounds. These settings
are then activated whenever the instrument is picked up.
2
SAN
1
S
1
3
0
2
L
2
1 Main functions – dark blue keys
1
Mouth rinsing position chair program
SS
00
11
2 Additional functions – light blue keys
2
22
SAN
L
3
3 Chair functions – gray keys
With memory function of last treatment position
Chair program 0
Entry/exit position (freely programmable)
Chair programs 1 and 2
(freely programmable)
The four program keys are also used for repro­gramming the chair programs.
Tumbler filling
ON/OFF
Cuspidor flushing
ON/OFF
X-ray image viewer ON/OFF
Also WHITE SCREEN activation for SIVISION
Sanitation of the treatment center
This key can be used to start the treatment center sanitation program.
Freely selectable function
The function can be preset as a button or switch in the Mode dialog.
Light ON/OFF
With SPRAYVIT picked up:
Instrument light
With SPRAYVIT in holder:
Operation light
Manual adjustment of headrest
Moving the headrest out/in
Quick Reference
Guide
S
0
S
0
.
6196369.fm Seite 2 Montag, 5. November 2007 4:55 16
4-way foot control
Positioning the patient
Backrest
Lever to the left: Backrest to the rear
Lever to the right: Backrest to the front
Height adjustment
Lever up: Chair moves up
Lever down: Chair moves down
Suction via 4-way foot control
When the large spray aspirator is removed from its holder, the suction current can be switched on and off with the 4-way foot control.
This function must be preselected in the mode dialog "SUCTION WITH CFS".
9
4-way control of headrest
Positioning the patient with the switches on the
motorized head rest
Moving the headrest in/out
Upper 4-way control up: Headrest moves out
Upper 4-way control down: Headrest moves in
Tilting the headrest
Upper 4-way control to the left: Headrest tilts back
Upper 4-way control to the right: Headrest tilts forward
Backrest
Lower 4-way control to the left: Backrest tilts to the rear
Lower 4-way control to the right: Backrest tilts forward
Height adjustment
Lower 4-way control down: Chair moves down
Lower 4-way control up: Chair moves up
1
0
Foot pedal
Activating the instrument
9 An instrument is removed.
¾ Step on the foot pedal.
ª The instrument starts running.
ª If appropriate, intensity control relative to
Travel on the track (toward the user)
9 All instruments are in place.
¾ Step on the foot pedal.
ª The dentist element moves toward the opera-
4-way foot control plate
Cursor control
9 The cursor control is activated (see Mode
C
B
A
¾ Shift 4-way foot control plate.
D
ª Cursor navigation along the marked path and
Dentist element travel (away from the user)
9 Cursor control switched off.
¾ Move 4-way foot control plate in direction B.
ª The dentist element moves away from the
Left button
Programmed movement to mouth rising position S
9 All instruments are in place.
¾ Press left key.
ª Programmed movment of chair to mouth rins-
Spray ON/OFF
9 An instrument is removed.
¾ Press left key.
ª Toggle between spray ON and spray OFF,
Foot switch for C
pedal movement (if “speed controller foot switch” has been preset under Mode).
tor as long as the foot switch is actuated.
dialog).
Cursor directions
A: forward – cursor up B: back – cursor down C: to the left – cursor to the left D: to the right – cursor to the right
triggering of the corresponding key function.
operator as long as the 4-way foot control is actuated.
ing position S or the last treatment position (depending on starting situation).
or SIVISION function.
+
Right button
Programmed movement to position 0
9 All instruments are in place.
¾ Press right key.
ª Programmed movement of the chair to entry/
Activating the chip blower
9 An instrument is removed.
¾ Press right key.
ª Chip blower active for duration of actuation,
11
Keys and LEDs
1 3 2
Operating mode displays
4 5 6 2
0 510
0 12.5
0 510 15 20
Mini L.E.D.
1 ON/OFF switch 2 Function button 3 Status control lamp
The Mini L.E.D. has three different modes. To select the desired menu, press function key 2.
4 Quick curing mode
Sec
5 Pulse curing mode
Sec.
6 “Soft start” mode
Sec.
exit position 0.
or SIVISION function.
green Normal operation
red, flashing Overheat protection
The Mini L.E.D. operates at full power for 10 seconds
The Mini L.E.D. runs at full power in the "Pulse" mode
12
Cameras
III III
2
1
1
Operating modes
VIDEO mode
A
VIDEOCAM VIDEO MODE
PC mode
A
VIDEOCAM PC MODE
A/B
Second monitor
function without
camera
SIROCAM 3
1 Slide switch for presetting the focusing range
before inserting the camera in the oral cavity.
Pos. I Detail exposure Pos. II Overview exposure Pos. III Whole-face exposure
2 Camera key for controlling different video
functions.
SIROCAM C
In the LIVE IMAGE mode, you can toggle between the close and far ranges by pressing button (1).
Button released – close range 5 – 15 mm
Key held down – far range 15 mm and more
The camera image is directly displayed on the SIVISION monitor. The quad image memory of the camera is activated.
If the camera is the active instrument, “VIDEOCAM” and the operating mode "VIDEO MODE" appear on the display.
The camera image is first processed on the PC and then the image generated on the PC is dis­played on the SIVISION monitor.
The proper use of the PC mode is described in detail in the unit operating instructions. The config­uration procedure is described in the instructions "PC Software Installation Manual", REF 59 11 719 (on CD).
PC mode<>VIDEO mode selection
9 with the camera removed
¾ press key A/D on the control panel.
All of the video functions that are activated by pressing the control panel keys can also be trig-
i
gered via the foot switch with the cursor functions.
The monitor integrated in the treatment center is used as a primary or secondary video display unit for the externally connected PC. Its factory set­tings and configuration procedure are described in the instructions "PC Software Installation Manual", REF 59 11 719 (on CD).
Patient communication system
40
100
2
30
75
20
0.2
rpmx1000
50
10
25
1
A/B
2
Grasping the camera ergonomically
The risk of blurred exposures can be reduced con­siderably by using a finger resting on the patient's chin as a "makeshift camera stand".
i
1 Displaying images, saving and deleting in the
1
Video mode
Display of still images
The camera can save 4 consecutive still images (identified with I, II, III and IIII).
A 5th view shows a QUAD IMAGE in which these 4 still images are tiled on the screen.
Saving still images in the video camera
9 The cursor is located in the Instrument key
block.
A/B
¾ Remove the camera (live image). ¾ Step on the foot pedal (still image I). ¾ Step on the foot pedal again (live image). ¾ Step on the foot pedal (still image I is
overwritten) etc.
To save still images II to IIII, switch to the next image memory location (see "Switching to the next image") and repeat the procedure.
Switching to the next image
9 with instruments in place or camera picked up ¾ Press the "Spray ON/OFF" key or ¾ Actuate the left foot switch key. ¾ In the SINGLE IMAGE mode, to switch to
the next memory location.
ª In the QUAD IMAGE mode, to switch to
memory location I, II, III or IIII for image selection.
SS1100
1
128
22
2
2 White screen/black screen
pбкзе~=aЙен~д=pулнЙгл=dгДe obc=SN=VS=PSV c~Дкбвлнк~ллЙ=PNI=SQSOR=_ЙелЬЙбгI=dЙкг~еу
Communication
Switching to the next image with the cursor
9 With the camera removed.
9 The cursor is in the chair programs key
block, level 1.
¾ 4-way foot control plate forward.
ª Switches through images:
STILL IMAGE I, STILL IMAGE II, STILL IMAGE III, STILL IMAGE IIII, QUAD IMAGE,
STILL IMAGE I, STILL IMAGE II.......
Toggling between QUAD IMAGE and SINGLE IMAGE
9 With instruments in place or camera
picked up.
¾ Actuate "Chip Blower" key or
¾ Actuate right left foot switch key.
ª Toggle between QUAD IMAGE and SINGLE
IMAGE.
ª When you switch to a SINGLE IMAGE, the
image previously selected in the QUAD
IMAGE is displayed.
Clearing the memory
9 Only with the camera removed and active!
¾ Actuate the "CCW rotation" key.
ª Clears all camera image memory locations.
The LIVE IMAGE mode for image I appears.
White screen
Switches WHITE SCREEN ON or OFF on the SIVISION monitor.
Black screen
100
Toggles between any view and a BLACK SCREEN. The previous view reappears when you
press this key again.
+
C2
Quick Reference Guide