Measuring methods are based on IHF and IEC standard 268-3
Measurements conditions,unless otherwise noted :
Output resistive load = (6) ohms / Both channel driven
Tone Direct ON , Other SW's : OFF
Nominal input level : 5mV for MM, 0.5mV for MC, 500mV for general purpose inputs
Power figures should be kept minimum 10min. between 15 and 35
Terminator : 100ohm for MC, 1kohm for MM and general purpose inputs
Filter : IHF-A filter R/O = Rated Output
Power supply : 120V/60Hz (A), 230V/50Hz (D/E/RDS), 220V/50Hz (C), 220V/60Hz (K)
FRONT AMP SECTION
* SUB-WOOFER SPKR : NO * SPKR LEVEL : ALL 0dB
* SPK SIZE : LLLN * EXT. IN * TONE OFF
INPUT FREQ. REMARK UNIT LIMIT L/R
NOMINAL
L/R
INPUT SENSITIVITY EXT. IN 1kHz R/O mV 280±30 280±50
TOTAL HARMONIC DISTORTION EXT. IN 40Hz R/O-3dB %
0.08 0.12
(STEREO IN) 1kHz
%
0.08 0.12
20KHz
%
0.12 0.2
CONTINUOUS AVERAGE POWER EXT. IN 40Hz (6)ohms W 95 90
at 0.2% THD 1kHz
W 100 95
(STEREO IN) 20KHz
W95 90
S/N RATIO, INPUT SHORT EXT. IN 1kHz R/O dB
90 85
IHF-A FILTER
FREQUENCY RESPONSE( -3dB ) EXT. IN 1W / 1kHz Ref. Hz~kHz 10~55 10~50
CENTER AMP SECTION
* SUB-WOOFER SPKR : NO * SPKR LEVEL : ALL 0dB
* SPK SIZE : LLLN * EXT. IN * TONE OFF
INPUT FREQ. REMARK UNIT LIMIT L/R
NOMINAL
L/R
INPUT SENSITIVITY EXT. IN 1kHz R/O mV 280±30 280±50
TOTAL HARMONIC DISTORTION EXT. IN 40Hz R/O-3dB %
0.08 0.12
1kHz
%
0.08 0.12
20KHz
%
0.12 0.2
CONTINUOUS AVERAGE POWER EXT. IN 40Hz (6)ohms W 95 90
at 0.2% THD 1kHz
W 100 95
20KHz
W95 90
S/N RATIO, INPUT SHORT EXT. IN 1kHz R/O dB
90 85
IHF-A FILTER
FREQUENCY RESPONSE( -3dB ) EXT. IN 1W / 1kHz Ref. Hz~kHz 10~55 10~50
SURROUND AMP SECTION
* SUB-WOOFER SPKR : NO * SPKR LEVEL : ALL 0dB
* SPK SIZE : LLLN * EXT. IN * TONE OFF
INPUT FREQ. REMARK UNIT LIMIT L/R
NOMINAL
L/R
INPUT SENSITIVITY EXT. IN 1kHz R/O mV 280±30 280±50
1
DESCRIPTION
DESCRIPTION
DESCRIPTIONNo.
2
3
4
5
No.
1
SPECIFICATIONS
1
2
3
5
No.
4