![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg1.png)
Drive Technologie \ Drive Automation \ System Integration \ Services
Operating Instructions
MOVIDRIVE
®
B, MOVIDRIVE
®
compact, MOVIDRIVE
®
A
Information regarding UL
Ausgabe 02/2010 16917219 / EN
![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg2.png)
SEW-EURODRIVE—Driving the world
![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg3.png)
Content
Content
1MOVIDRIVE® B .................................................................................................... 4
1.1 Information regarding UL ............................................................................ 4
1.2 Wiring diagram for basic unit ...................................................................... 7
2MOVIDRIVE
2.1 Information Regarding UL......................................................................... 10
2.2 Wiring diagram for basic unit .................................................................... 12
3MOVIDRIVE
3.1 Information Regarding UL......................................................................... 14
3.2 Wiring diagram for basic unit .................................................................... 16
®
compact ...................................................................................... 10
®
A .................................................................................................. 14
Operating Instructions – MOVIDRIVE® MDX60B/61B
3
![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg4.png)
1
MOVIDRIVE® B
Information regarding UL
1MOVIDRIVE® B
1.1 Information regarding UL
1.1.1 Field wiring power terminals
• Use 60/75 °C copper wire only – Models with suffix 0003 to 0300.
Use 75 °C copper wire only – Models with suffix 0370 to 2500.
• Tighten terminals to in-lbs (Nm) as follows:
Series Frame size in-lbs Nm
MOVIDRIVE
®
B 0XS, 0S, 0L 5 0.6
1, 2S 5 0.6
2131.5
3313.5
4, 5 120 14
6 180 20
7 620 70
1.1.2 Short-circuit current rating
• Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes:
– MOVIDRIVE
Max. voltage is limited to 500 V.
– MOVIDRIVE
Max. voltage is limited to 240 V.
®
B models with suffix 0005 to 2500 (400 V units only).
®
B models with suffix 0015 to 0300 (230 V units only).
4
Operating Instructions – MOVIDRIVE® MDX60B/61B
![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg5.png)
1.1.3 Branch circuit protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
For maximum fuse rating see tables below.
AC 400/500 V
units
MOVIDRIVE®
MDX60B/61B...5_3
0005/0008/0011/0014 AC 200,000 A AC 500 V AC 15 A / 600 V
0015/0022/0030/0040 AC 200,000 A AC 500 V AC 35 A / 600 V
0055/0075 AC 200,000 A AC 500 V AC 60 A / 600 V
0110 AC 200,000 A AC 500 V AC 110 A / 600 V
0150/0220 AC 200,000 A AC 500 V AC 175 A / 600 V
0300 AC 200,000 A AC 500 V AC 225 A / 600 V
0370/0450 AC 200,000 A AC 500 V AC 350 A / 600 V
0550/0750 AC 200,000 A AC 500 V AC 500 A / 600 V
0900 AC 200,000 A AC 500 V AC 250 A / 600 V
1100 AC 200,000 A AC 500 V AC 300 A / 600 V
1320 AC 200,000 A AC 500 V AC 400 A / 600 V
1600 AC 200,000 A AC 500 V AC 400 A / 600 V
2000 AC 200,000 A AC 500 V AC 500 A / 600 V
2500 AC 200,000 A AC 500 V AC 600 A / 600 V
Information regarding UL
Max. supply short circuit current
MOVIDRIVE® B
Max. supply voltage Max. fuse rating
1
AC 230 V units
MOVIDRIVE®
MDX61B...2_3
0015/0022/0037 AC 200,000 A AC 240 V AC 30 A / 250 V
0055/0075 AC 200,000 A AC 240 V AC 110 A / 250 V
0110 AC 200,000 A AC 240 V AC 175 A / 250 V
0150 AC 200,000 A AC 240 V AC 225 A / 250 V
0220/0300 AC 200,000 A AC 240 V AC 350 A / 250 V
Max. supply short circuit current
Max. supply voltage Max. fuse rating
Operating Instructions – MOVIDRIVE® MDX60B/61B
5
![](/html/2f/2fc3/2fc377e82598c3064e48302d0dc71823f1097681d21d1762ade17e7df62a9338/bg6.png)
1
1.1.4 Motor Overload Protection
1.1.5 Ambient temperature
MOVIDRIVE® B
Information regarding UL
The units are provided with motor overload protection with a trip current adjusted to
150% of the rated motor current.
The units are suitable for an ambient temperature of 40 °C, max. 60 °C with derated output current.
To determine output current rating at higher than 40 °C, the output current should be derated 2.5 % per °C between 40 °C and 50 °C, and 3 % per °C between 50 °C and 60 °C.
INFORMATION
• An external DC 24 V voltage supply has to be limited to a max. voltage
• UL certification does not apply to operation in voltage supply systems with a
U
= DC 30 V and max. current I
max
non-grounded star point (IT systems).
max
= 8 A.