RKMB
Parts List 25-November-2015
This parts list is current as of the above revision date.
See http://www.rheempartslists.net/92-42800-RKMB.pdf for the current revision.
Package Gas-Electric - Commercial
Table of Contents
Model Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3
Parts Numbers
Panels - Miscellaneous 090-150 (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4
Panels - Miscellaneous 090-150 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5
Panels - Miscellaneous 180-240 (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
Panels - Miscellaneous 180-240 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
Electrical Group (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8
Electrical Group (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9
Electrical Group (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10
Fan Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Coil Parts 090-150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Coil Parts 180-240. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13
Blower Group 090-150 (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14
Blower Group 090-150 (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15
Blower Group 180-240. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16
Compressor Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 17
Heat Exchanger-Burner Group 090-150 15-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18
Heat Exchanger-Burner Group 180 25-35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19
Heat Exchanger-Burner Group 240 30-40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
Gas Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 22
Orifice Selection Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 23
Drawings/Photographs
Exploded View 090-150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 24
Exploded View 180 240. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25
Filter Rack Assembly 090-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
Coil Assembly 090-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
Control Board Assembly 090-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 27
Blower Assembly 090-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 27
Heat Exchanger Assembly 090-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 28
Heat Exchanger Assembly 180 240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
Control Board Assembly 180 240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
Coil Assembly 180 240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
Blower Assembly 180 240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 30
Evaporator Coil Assembly 090-120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31
Evaporator Coil Assembly 0150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31
Evaporator Coil Assembly 180-240. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 32
Notes/Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 33
25-November-2015
92-42800-RKMB
Page 2 of 33
|
|
|
|
|
|
|
MODEL NUMBER EXPLANATION |
|
|
|
|
|
|
|||||
|
|
|
R |
K |
M |
B |
- |
A |
0 |
9 |
0 |
C |
L |
1 |
5 |
E |
|
|
|
|
|
1 |
2 |
3 |
4 |
|
5 |
|
6 |
|
7 |
8 |
|
9 |
10 |
|
|
|
|
1 |
TRADENAME |
|
|
|
|
|
|
7 |
ELECTRICAL DESIGNATION |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
C = 208-230/3/60 |
|
|
|
|
||
|
|
2 |
K - ROOFTOP COMMERCIAL |
|
|
|
|
D = 460/3/60 |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
N = 380-415/3/50 |
|
|
|
|
||
|
|
3 |
EFFICIENCY DESIGNATION |
|
|
|
|
P = 200-220/3/50 |
|
|
|
|
||||||
|
|
|
K = Standard Efficiency (10 SEER) |
|
|
|
|
Y = 575/3/60 |
|
|
|
|
|
|||||
|
|
|
M = High Efficiency (12 SEER) |
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
8 |
DRIVE PACKAGE |
|
|
|
|
||
|
|
4 |
DESIGN SERIES |
|
|
|
|
|
|
L = Belt Drive |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
M = Belt Drive - High Static |
|
|
|
|||
|
|
5 |
TECHNICAL VARIATIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
9 |
HEATING CAPACITY - (MBH) |
|
|
||||
|
|
6 |
COOLING CAPACITY (BTU/HR) |
|
|
|
|
12 = 120,000 |
|
29 = 290,000 |
|
|
||||||
|
|
|
090 = 90,000 |
|
180 = 180,000 |
|
|
|
|
15 = 150,000 |
|
30 = 300,000 |
|
|
||||
|
|
|
102 = 102,000 |
|
240 = 240,000 |
|
|
|
|
18 = 180,000 |
|
33 = 330,000 |
|
|
||||
|
|
|
120 = 120,000 |
|
|
|
|
|
|
|
21 = 210,000 |
|
35 = 350,000 |
|
|
|||
|
|
|
150 = 150,000 |
|
|
|
|
|
|
|
22 = 225,000 |
|
40 = 400,000 |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
25 = 252,000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
IGNITION SYSTEM |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
E = Electric |
|
|
|
|
|
|
|
|
|
|
|
|
|
SERIAL NUMBER EXPLANATION |
|
|
|
|
|
|
|||||
1 Z |
A |
1 |
2 |
3 |
4 |
A |
A |
A |
F |
2 |
6 |
9 |
9 |
9 |
9 |
9 |
9 |
9 |
1 |
2 |
|
|
3 |
|
4 |
5 |
6 |
7 |
|
|
8 |
|
|
|
9 |
|
|
|
|
1 |
GAS CODE |
|
|
|
|
|
|
6 |
TECHNOLOGY VARIATIONS |
|
|
|
||||
|
|
2 |
COMPRESSOR IDENTIFICATION NO. |
|
|
7 |
PRODUCTION LOCATION |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
F = Fort Smith, AR |
|
|
|
|
||
|
|
3 |
IGNITION DEVICE |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
8 |
DATE CODE |
|
|
|
|
|
|
|
|
4 |
INDUCER BLOWER |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
9 |
PRODUCTION NUMBER |
|
|
|
|||
|
|
5 |
HEAT EXCHANGER |
|
|
|
|
|
|
|
|
|
|
|
|
25-November-2015
92-42800-RKMB
Page 3 of 33
|
MODEL |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
|
|
COOLING CAPACITY |
090/102 |
120/150 |
|
|
|
|
|
|
PANELS, MISCELLANEOUS PARTS |
|
|
BASE RAILS: |
|
|
A |
Front |
AE-90575-03 |
AE-90575-03 |
B |
Right |
AE-90576-03 |
AE-90576-03 |
C |
Rear |
AE-90575-04 |
AE-90575-04 |
D |
Left |
AE-90576-04 |
AE-90576-04 |
|
BASE PANS: |
|
|
E |
Outdoor Coil Base Pan |
AS-90577-03 |
AS-90577-05 |
F |
Indoor Coil Base Pan |
AS-90577-02 |
AS-90577-02 |
|
INSIDE CABINET PANEL/PIECES: |
|
|
G |
Entry Plate |
AE-90614-02 |
AE-90614-02 |
H |
Entry Plate |
AE-90614-01 |
AE-90614-01 |
J |
Heat Compartment Side |
AE-90598-03 |
AE-90598-03 |
K |
Blower Deck |
AS-90592-02 |
AS-90592-02 |
L |
Wireway |
AE-90718-02 |
AE-90718-02 |
M |
Condenser Bulkhead |
AS-90609-03 |
AS-90609-06 |
N |
Tube Support Right Angle |
AE-90600-02 |
AE-90600-02 |
P |
Tube Support Left Angle |
AE-90600-01 |
AE-90600-01 |
R |
Limit Cover |
AS-59152-01 |
AS-59152-01 |
|
MODEL |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
|
|
COOLING CAPACITY |
090/102 |
120/150 |
|
|
|
|
|
|
PANELS - FRONT |
|
|
FRONT: |
|
|
1 |
Control Box / Filter Access Panel |
AS-90678-02 |
AS-90678-02 |
2 |
Hinge |
64-42546-03 |
64-42546-03 |
3 |
Hinge |
64-42546-04 |
64-42546-04 |
4 |
Left - Front Panel |
AS-90620-07 |
AS-90620-07 |
5 |
Control Box Cover |
AE-90713-02 |
AE-90713-02 |
6 |
Control Mounting Plate |
AE-90712-02 |
AE-90712-02 |
7 |
Low Voltage Shield |
AE-90742-02 |
AE-90742-02 |
8 |
Control Box Back |
AS-90601-02 |
AS-90601-02 |
9 |
Bracket |
AE-90779-02 |
AE-90779-02 |
10 |
Inlet Flue Hood (2) |
AE-90745-01 |
AE-90745-01 |
11 |
Flue Hood |
AS-90637-02 |
AS-90637-02 |
12a |
Gas Furnace Access Panel |
AS-90715-02 |
AS-90715-02 |
12b |
Hinge |
64-42546-04 |
64-42546-04 |
12c |
Hinge |
64-42546-03 |
64-42546-03 |
13 |
Gas Pipe Support Plate |
AS-90774-01 |
AS-90774-01 |
14 |
Blower Access Panel |
AS-90622-02 |
AS-90622-02 |
15 |
Right - Front Panel |
AS-90620-06 |
AS-90620-06 |
16 |
Heat Exchanger Mounting Frame |
AS-90754-01 |
AS-90754-01 |
17 |
Condenser Coil Access Panel-Front |
AE-90631-03 |
AE-90631-04 |
18 |
Front Corner Post |
AE-90701-02 |
AE-90701-02 |
25-November-2015
92-42800-RKMB
Page 4 of 33
|
MODEL |
RKMB |
RKMB |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
A |
A |
|
|
COOLING CAPACITY |
090 |
102 |
120 |
150 |
|
|
|
|
|
|
|
|
PANELS - RIGHT, REAR AND LEFT SIDES |
|
|
|
|
RIGHT: |
|
|
|
|
19 |
Air Stop |
AE-90760-01 |
N/A |
AE-90760-01 |
N/A |
20 |
Louvered Panel |
AS-90789-01 |
AS-90789-01 |
AS-90789-01 |
AS-90789-01 |
|
REAR: |
|
|
|
|
21 |
Rear Corner Post |
AE-90702-03 |
AE-90702-03 |
AE-90702-03 |
AE-90702-03 |
22 |
Condenser Coil Access Panel - Rear |
AE-90631-03 |
AE-90631-03 |
AE-90631-03 |
AS-90683-04 |
23 |
Rear Panel |
AS-90618-02 |
AS-90618-02 |
AS-90618-02 |
AS-90618-02 |
24 |
Supply Cover |
AS-90626-02 |
AS-90626-02 |
AS-90626-02 |
AS-90626-02 |
25 |
Return Cover |
AS-90628-02 |
AS-90628-02 |
AS-90628-02 |
AS-90628-02 |
|
LEFT: |
|
|
|
|
26 |
Upper Left Panel |
AS-90624-03 |
AS-90624-03 |
AS-90624-03 |
AS-90624-03 |
27 |
Lower Left Panel |
AS-90624-04 |
AS-90624-04 |
AS-90624-04 |
AS-90624-04 |
28 |
Left Corner Panel |
AS-90755-02 |
AS-90755-02 |
AS-90755-02 |
AS-90755-02 |
29 |
Receptacle Plate-Inside Panel |
AE-90756-02 |
AE-90756-02 |
AE-90756-02 |
AE-90756-02 |
30 |
Disconnect Plate-Install Panel |
AE-90756-03 |
AE-90756-03 |
AE-90756-03 |
AE-90756-03 |
31 |
Button Plug (2) |
45-22980-06 |
45-22980-06 |
45-22980-06 |
45-22980-06 |
32 |
Button Plug |
45-22980-05 |
45-22980-05 |
45-22980-05 |
45-22980-05 |
|
TOP: |
|
|
|
|
33 |
Top Panel |
AS-90616-02 |
AS-90616-02 |
AS-90616-02 |
AS-90616-02 |
34 |
Condenser Top Panel |
AS-90703-02 |
AS-90703-02 |
AS-90703-02 |
AS-90703-02 |
35 |
Venturi (2) |
AE-90632-01 |
AE-90632-01 |
AE-90632-01 |
AE-90632-01 |
36 |
Wire Grille (2) |
95-42507-01 |
95-42507-01 |
95-42507-01 |
95-42507-01 |
25-November-2015
92-42800-RKMB
Page 5 of 33
|
MODEL |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
|
|
COOLING CAPACITY |
180 |
240 |
|
|
|
|
|
PANELS, MISCELLANEOUS PARTS - BASE RAILS, INSIDE CABINET |
|
|
|
BASE RAILS: |
|
|
A |
Front |
AS-90827-01 |
AS-90827-01 |
B |
Right |
AE-90576-03 |
AE-90576-03 |
C |
Rear |
AS-90827-01 |
AS-90827-01 |
D |
Left |
AE-90576-04 |
AE-90576-04 |
|
BASE PANS: |
|
|
E |
Outdoor Base Pan |
AS-90577-06 |
AS-90577-06 |
F |
Indoor Coil Base Pan - Return Air |
AS-90578-04 |
AS-90578-04 |
G |
Indoor Coil Base Pan - Supply Air |
AS-90578-03 |
AS-90578-03 |
|
INSIDE CABINET PANEL/ PIECES: |
|
|
H |
Entry Plate (2) |
AE-90614-01 |
AE-90614-01 |
J |
Heat Compartment Side |
AE-90598-03 |
AE-90598-03 |
K |
Blower Deck |
AS-90592-05 |
AS-90592-05 |
L |
Wireway |
AE-90718-03 |
AE-90718-03 |
M |
Condenser Bulkhead |
AS-90609-08 |
AS-90609-08 |
N |
Tube Support Right Angle (2) |
AE-90600-02 |
AE-90600-02 |
R |
Limit Cover |
AS-59152-01 |
AS-59152-01 |
S |
Air Stop - Outdoor CoilFront |
AE-90706-08 |
AE-90706-08 |
T |
Air Stop - Outdoor CoilRear |
AE-90706-07 |
AE-90706-07 |
U |
Coil Mounting Angle (2) |
AE-90706-05 |
AE-90706-05 |
W |
Outdoor Coil Divider Panel |
AE-90735-03 |
AE-90735-03 |
X |
Coil Support Brace |
AE-90706-01 |
AE-90706-01 |
Y |
Condenser CoilAir Stop Rear |
AE-90753-04 |
AE-90753-04 |
Z |
Condenser CoilAir Stop Front |
AE-90753-03 |
AE-90753-03 |
|
MODEL |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
|
|
COOLING CAPACITY |
180 |
240 |
|
|
|
|
|
PANELS, MISCELLANEOUS PARTS - FRONT AND RIGHT SIDES |
|
|
1 |
Control Box / Filter Access Panel |
AS-90678-03 |
AS-90678-03 |
2 |
Hinge |
64-42546-03 |
64-42546-03 |
3 |
Hinge |
64-42546-04 |
64-42546-04 |
4 |
Left - Front Panel |
AS-90620-11 |
AS-90620-11 |
5 |
Control Box Cover |
AE-90713-03 |
AE-90713-03 |
6 |
Control Mounting Plate |
AE-90712-03 |
AE-90712-03 |
7 |
Low Voltage Shield |
AE-90742-04 |
AE-90742-04 |
8 |
Control Box Back |
AS-90601-03 |
AS-90601-03 |
9 |
Bracket |
AE-90779-02 |
AE-90779-02 |
10 |
Inlet Flue Hood (4) |
AE-90745-01 |
AE-90745-01 |
11 |
Flue Hood (2) |
AS-90637-02 |
AS-90637-02 |
12a |
Gas Furnace Access Panel |
|
|
12b |
Hinge (2) |
64-42546-03 |
64-42546-03 |
12c |
Hinge (2) |
64-42546-04 |
64-42546-04 |
13 |
Gas Pipe Support Plate |
AS-90774-03 |
AS-90774-03 |
14 |
Blower Access Panel |
AS-90622-03 |
AS-90622-03 |
15 |
Right - Front Panel |
AS-90620-10 |
AS-90620-10 |
16 |
Heat Exchanger Mounting Frame |
AS-90754-03 |
AS-90754-03 |
17 |
Louvered Panel - Large |
AE-90726-06 |
AE-90726-06 |
18 |
Louvered Panel - Small |
AE-90726-07 |
AE-90726-07 |
19 |
Front/ Rear Post - Middle |
AE-90732-03 |
AE-90732-03 |
20 |
Condenser Access Panel |
AE-90734-05 |
AE-90734-05 |
21 |
Front/ Rear Corner Post |
AE-90701-03 |
AE-90701-03 |
25-November-2015
92-42800-RKMB
Page 6 of 33
|
MODEL |
RKMB |
RKMB |
No. Notes TECHNICAL VARIATIONS |
A |
A |
|
|
COOLING CAPACITY |
180 |
240 |
|
|
|
|
|
|
PANELS - TOP, REAR AND LEFT SIDES |
|
|
REAR: |
|
|
17 |
Louvered Panel - Large |
AE-90726-06 |
AE-90726-06 |
18 |
Louvered Panel - Small |
AE-90726-07 |
AE-90726-07 |
19 |
Front/ Rear Post - Middle |
AE-90732-03 |
AE-90732-03 |
21 |
Front/ Rear Corner Post |
AE-90701-03 |
AE-90701-03 |
22 |
Right Rear Panel |
AS-90618-04 |
AS-90618-04 |
23 |
Left Rear Panel |
AS-90618-03 |
AS-90618-03 |
24 |
Supply Cover |
AS-90628-03 |
AS-90628-03 |
25 |
Return Cover |
AS-90628-03 |
AS-90628-03 |
|
LEFT: |
|
|
26 |
Upper Left Panel |
AS-90624-06 |
AS-90624-06 |
27 |
Lower Left Panel |
AS-90624-04 |
AS-90624-04 |
28 |
Left Corner Panel |
AS-90755-03 |
AS-90755-03 |
|
Bracket (2) |
AE-90779-01 |
AE-90779-01 |
|
Gasket for receptacle plate |
68-42514-08 |
68-42514-08 |
|
Gasket for disconnect plate |
68-42514-09 |
68-42514-09 |
29 |
Plate - Install inside Panel - Receptacle |
AE-90756-02 |
AE-90756-02 |
30 |
Plate - Install inside Panel - Disconnect |
AE-90756-03 |
AE-90756-03 |
|
TOP: |
|
|
31 |
Outdoor Top Front Panel |
AE-90633-06 |
AE-90633-06 |
32 |
Outdoor Top Rear Panel |
AE-90633-05 |
AE-90633-05 |
33 |
Outdoor Top Support |
AE-90704-04 |
AE-90704-04 |
34 |
Top Panel |
AS-90616-03 |
AS-90616-03 |
35 |
Venturi (4) |
AE-90632-01 |
AE-90632-01 |
36 |
Wire Grille (4) |
95-42507-01 |
95-42507-01 |
25-November-2015
92-42800-RKMB
Page 7 of 33
|
|
MODEL |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
|
|
|
COOLING CAPACITY |
090-150 |
090-150 |
090-150 |
|
|
ELECTRICAL DESIGNATION |
C/P |
D/N |
Y |
|
|
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
|
|
CONTROL BOX COMPONENTS: |
|
|
|
6 |
Stk |
Control Box Mounting Panel |
AE-90712-02 |
AE-90712-02 |
AE-90712-02 |
56 |
|
Integrated Furnace Control (IFC) |
|
See Gas Controls |
|
57 |
Stk |
Transformer (Before F2301) |
46-42515-01 |
46-42515-01 |
46-42515-01 |
57 |
Stk |
Transformer (After F2301) |
46-42515-01 |
46-42515-02 |
46-42515-01 |
58 |
|
Double Row Terminal Block |
45-42548-02 |
45-42548-02 |
45-42548-02 |
59 |
Stk |
Blower Contactor |
42-25103-02 |
42-25103-02 |
42-25103-02 |
60 |
|
Run Capacitor |
|
See Fan Group |
|
Note: Low Voltage Terminal Block - 7 terminal block pieces are used in this application. The replacement 45-40361-66 is a kit that includes 13 terminal block pieces and 1 end piece. Order the amount of kits based on the replacement needed.
61 |
|
Low Voltage Terminal Block |
45-40361-66 |
45-40361-66 |
45-40361-66 |
62 |
Stk |
Compressor Contactor (2) |
42-25103-01 |
42-25103-01 |
42-25103-01 |
63 |
Stk |
Step Down Transformer (2) (Before F2301) |
N/A |
46-23585-01 |
46-23585-01 |
63 |
Stk |
Step Down Transformer (2) (After F2301) |
N/A |
N/A |
46-23585-01 |
|
|
Induced Draft Relay (2) (After F2301) |
N/A |
42-19736-04 |
N/A |
|
|
MODEL |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
|
|
|
COOLING CAPACITY |
180/240 |
180/240 |
180/240 |
|
|
ELECTRICAL DESIGNATION |
C |
D |
Y |
|
|
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
56 |
|
Integrated Furnace Control Board - Label IFC |
|
See Gas Controls |
|
62a |
Stk |
Compressor Contactor - Label CC 1 |
42-42139-08 |
42-42139-08 |
42-42139-08 |
62b |
Stk |
Compressor Contactor - Label CC 2 |
42-42139-08 |
42-42139-08 |
42-42139-08 |
62c |
Stk |
Compressor Contactor - Label CC 3 |
42-42139-08 |
42-42139-08 |
42-42139-08 |
62d |
Stk |
Compressor Contactor - Label CC 4 |
42-42139-08 |
42-42139-08 |
42-42139-08 |
60a |
|
Run Capacitor - Label RC 1 |
|
See Fan Group |
|
60b |
|
Run Capacitor - Label RC 2 |
|
See Fan Group |
|
60c |
|
Run Capacitor - Label RC 3 |
|
See Fan Group |
|
60d |
|
Run Capacitor - Label RC 4 |
|
See Fan Group |
|
38 |
|
Terminal Block - Label TB 1 |
45-21134-04 |
45-21134-04 |
45-21134-04 |
Note: Low Voltage Terminal Block - 7 terminal block pieces are used in this application. The replacement 45-40361-66 is a kit that includes 13 terminal block pieces and 1 end piece. Order the amount of kits based on the replacement needed.
61 |
|
Low Voltage Terminal Block - Label TB 2 |
45-40361-66 |
45-40361-66 |
45-40361-66 |
58a |
|
Double Row Terminal Block - Label TB 4 |
45-42548-02 |
45-42548-02 |
45-42548-02 |
58b |
|
Double Row Terminal Block - Label TB 5 |
45-42548-02 |
45-42548-02 |
45-42548-02 |
Note: The following date code changes are related to the change in the Induced Draft Blower Motor |
|
|
|
||
|
|
Unit date code on or before F1901 |
|
|
|
57 |
Stk |
Transformer - Label CT |
46-42515-04 |
46-42515-04 |
46-42515-04 |
63a |
|
Transformer - Label PT 1 |
N/A |
46-23585-01 |
46-23585-01 |
63b |
|
Transformer - Label PT 2 |
N/A |
46-23585-01 |
46-23585-01 |
63c |
|
Transformer - Label PT 3 |
N/A |
46-23585-01 |
46-23585-01 |
63d |
|
Transformer - Label PT 4 |
N/A |
46-23585-01 |
46-23585-01 |
59 |
Stk |
Blower Contactor - Label BC |
42-25103-02 |
42-22641-03 |
42-25103-02 |
|
|
Unit date code after F1901 |
|
|
|
57 |
Stk |
Transformer - label CT |
46-42515-04 |
46-42515-05 |
46-42515-04 |
63a |
|
Transformer - Label PT 1 |
N/A |
N/A |
46-23585-01 |
63b |
|
Transformer - Label PT 2 |
N/A |
N/A |
46-23585-01 |
63c |
|
Transformer - Label PT 3 |
N/A |
N/A |
46-23585-01 |
63d |
|
Transformer - Label PT 4 |
N/A |
N/A |
46-23585-01 |
|
|
Induced Draft Relay - Label IDR 1 |
N/A |
42-19736-04 |
N/A |
|
|
Induced Draft Relay - Label IDR 2 |
N/A |
42-19736-04 |
N/A |
|
|
Terminal Block - Label TB 3 |
N/A |
45-42548-02 |
N/A |
59 |
Stk |
Blower Contactor - Label BC |
42-25103-02 |
42-25103-01 |
42-25103-02 |
25-November-2015
92-42800-RKMB
Page 8 of 33
|
MODEL |
RKMB |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
A |
|
COOLING CAPACITY |
090 |
102 |
120 |
150 |
|
ELECTRICAL DESIGNATION |
C/P |
C/P |
C/P |
C/P |
|
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
|
|
Wiring Harness - 12 Pin from IFC (15E) |
45-42522-23 |
45-42522-23 |
45-42522-23 |
45-42522-23 |
|
Wiring Harness - 12 Pin from IFC (22E, 25E) |
45-42522-11 |
45-42522-11 |
45-42522-11 |
45-42522-11 |
|
Wiring Harness - Outdoor Fan 1 |
45-42522-12 |
45-42522-12 |
45-42522-12 |
45-42522-26 |
|
Wiring Harness - Outdoor Fan 2 |
45-42522-14 |
45-42522-14 |
45-42522-14 |
45-42522-28 |
|
Wiring Harness - Draft Inducer |
45-42522-19 |
45-42522-19 |
45-42522-19 |
45-42522-30 |
|
Wiring Harness - Economizer |
45-42522-20 |
45-42522-20 |
45-42522-20 |
45-42522-20 |
|
Bypass Plug - Economizer (12 Pin) |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
|
Wiring Harness - Compressor 1 |
45-42522-21 |
45-42522-21 |
45-42522-03 |
Call for availability |
|
Wiring Harness - Compressor 2 |
45-42522-22 |
45-42522-22 |
45-42522-15 |
Call for availability |
|
MODEL |
RKMB |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
A |
|
COOLING CAPACITY |
090 |
102 |
120 |
150 |
|
ELECTRICAL DESIGNATION |
D/N |
D/N |
D/N |
D/N |
|
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
|
|
Wiring Harness - 12 Pin from IFC (15E) |
45-42522-23 |
45-42522-23 |
45-42522-23 |
45-42522-23 |
|
Wiring Harness - 12 Pin from IFC (22E, 25E) |
45-42522-11 |
45-42522-11 |
45-42522-11 |
45-42522-11 |
|
Wiring Harness - Outdoor Fan 1 |
45-42522-12 |
45-42522-12 |
45-42522-12 |
45-42522-26 |
|
Wiring Harness - Outdoor Fan 2 |
45-42522-14 |
45-42522-14 |
45-42522-14 |
45-42522-28 |
|
Wiring Harness - Draft Inducer |
45-42522-19 |
45-42522-19 |
45-42522-19 |
45-42522-30 |
|
Wiring Harness - Economizer |
45-42522-20 |
45-42522-20 |
45-42522-20 |
45-42522-20 |
|
Bypass Plug - Economizer (12 Pin) |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
|
Wiring Harness - Compressor 1 |
45-42522-21 |
45-42522-21 |
45-42522-21 |
Call for availability |
|
Wiring Harness - Compressor 2 |
45-42522-22 |
45-42522-22 |
45-42522-22 |
Call for availability |
|
MODEL |
RKMB |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
A |
|
COOLING CAPACITY |
090 |
102 |
120 |
150 |
|
ELECTRICAL DESIGNATION |
Y |
Y |
Y |
Y |
|
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
|
|
Wiring Harness - 12 Pin from IFC (15E) |
45-42522-23 |
45-42522-23 |
45-42522-23 |
45-42522-23 |
|
Wiring Harness - 12 Pin from IFC (22E, 25E) |
45-42522-11 |
45-42522-11 |
45-42522-11 |
45-42522-11 |
|
Wiring Harness - Outdoor Fan 1 |
45-42522-12 |
45-42522-12 |
45-42522-12 |
45-42522-26 |
|
Wiring Harness - Outdoor Fan 2 |
45-42522-14 |
45-42522-14 |
45-42522-14 |
45-42522-28 |
|
Wiring Harness - Draft Inducer |
45-42522-19 |
45-42522-19 |
45-42522-19 |
45-42522-30 |
|
Wiring Harness - Economizer |
45-42522-20 |
45-42522-20 |
45-42522-20 |
45-42522-20 |
|
Bypass Plug - Economizer (12 Pin) |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
|
Wiring Harness - Compressor 1 |
45-42522-21 |
45-42522-21 |
45-42522-21 |
Call for availability |
|
Wiring Harness - Compressor 2 |
45-42522-22 |
45-42522-22 |
45-42522-22 |
Call for availability |
25-November-2015
92-42800-RKMB
Page 9 of 33
|
MODEL |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
|
COOLING CAPACITY |
180 |
180 |
180 |
|
ELECTRICAL DESIGNATION |
C |
D |
Y |
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
4 |
Wiring Harness - 12 Pin from IFC (See Note 4) |
45-42522-44 |
45-42522-44 |
45-42522-44 |
|
Wiring Harness - Outdoor Fan 1 |
45-42522-33 |
45-42522-33 |
45-42522-33 |
|
Wiring Harness - Outdoor Fan 2 |
45-42522-34 |
45-42522-34 |
45-42522-34 |
|
Wiring Harness - Outdoor Fan 3 |
45-42522-35 |
45-42522-35 |
45-42522-35 |
|
Wiring Harness - Outdoor Fan 4 |
45-42522-36 |
45-42522-36 |
45-42522-36 |
|
Wiring Harness - Draft Inducer (30E, 35E) |
45-42522-38 |
45-42522-38 |
45-42522-38 |
|
Bypass Plug - Economizer (12 Pin) |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
|
MODEL |
RKMB |
RKMB |
RKMB |
No. Notes |
TECHNICAL VARIATION |
A |
A |
A |
|
COOLING CAPACITY |
240 |
240 |
240 |
|
ELECTRICAL DESIGNATION |
C |
D |
Y |
|
|
|
|
|
|
|
ELECTRIC GROUP |
|
|
4 |
Wiring Harness - 12 Pin from IFC (See Note 4) |
45-42522-44 |
45-42522-44 |
45-42522-44 |
|
Wiring Harness - Outdoor Fan 1 |
45-42522-33 |
45-42522-33 |
45-42522-33 |
|
Wiring Harness - Outdoor Fan 2 |
45-42522-34 |
45-42522-34 |
45-42522-34 |
|
Wiring Harness - Outdoor Fan 3 |
45-42522-35 |
45-42522-35 |
45-42522-35 |
|
Wiring Harness - Outdoor Fan 4 |
45-42522-36 |
45-42522-36 |
45-42522-36 |
|
Wiring Harness - Draft Inducer (30E) |
45-42522-38 |
45-42522-38 |
45-42522-38 |
|
Bypass Plug - Economizer (12 Pin) |
AS-61997-55 |
AS-61997-55 |
AS-61997-55 |
25-November-2015
92-42800-RKMB
Page 10 of 33