Gas Furnaces
Air
R96V Series
Rheem Prestige Series™ Communicating Two Stage Variable Speed Multi position Gas Furnaces
R96VSeries
96% A.F.U.E.†
Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW]
All Models except R96VA085
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
•96% residential gas furnace CSA certified
•4 way multi-poise design
•Two stages of operation to save energy and maintain optimal comfort level.
•Variable speed blower motor technology provides ultimate humidity control, quieter sound levels, and year round energy savings.
•EcoNet™ enabled HVAC Product
•PlusOne™ Diagnostics 7-Segment LED all units
•PlusOne™ Ignition System – DSI for reliability and longevity
•PlusOne™ Water Management System with patented Blocked Drain Sensor
•Heat exchanger is removable for improved serviceability. Aluminized steel primary and stainless steel secondary construction provide maximum corrosion resistance and thermal fatigue reliability.
•Low profile “34 inch” cabinet ideal for space constrained installations.
•Blower Shelf design – serviceable in all furnace orientations
•Pre marked hoses – insures proper system drainage
•Vent with 2" or 3" PVC
•Replaceable Collector box
•Hemmed edges on cabinet and doors
•Quarter turn fasteners for tool less access
•Integrated control boards feature dip switches for easy system set up
•Self priming condensate trap
•Solid bottom included
•Compatible with single or two stage thermostats. For optimal performance a two stage thermostat is recommended.
FORM NO. G11-540 REV. 4
Table of Contents
Air
R96V Series
TABLE OF CONTENTS |
|
Standard & Optional Equipment ...................................................................... |
3 |
Physical Data & Specifications ........................................................................ |
4 |
Model Number Identification ............................................................................ |
5 |
Dimensional Data............................................................................................ |
6 |
Blower Performance Data ................................................................................ |
7 |
Accessories.................................................................................................... |
8 |
Limited Warranty ............................................................................................ |
9 |
2
REMOTE
SENSOR
PRIMARY AND SECONDARY
HEAT EXCHANGER
IN-SHOT BURNERS
PRESSURE SWITCHES
ECM MOTOR
CONTROL BOARD
STANDARD EQUIPMENT
Completely assembled and wired; blocked drain sensor, 7 segment LED and marked hoses; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; 2 stage induced draft; pressure switches; redundant 2 stage main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and selftest diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; transformer; direct drive, variable speed electrically commutated blower motor (ECM). Solid bottom. (Please note: a thermostat is not included as standard equipment.)
Standard & Optional Equipment
Air
R96V Series
DIRECT SPARK IGNITION &
REMOTE SENSOR
GAS VALVE AND MANIFOLD
DRAFT
INDUCER
BLOCKED DRAIN
SENSOR
OPTIONAL EQUIPMENT
Side and bottom filter racks; return air cabinet for all sizes.
NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas.
All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
3
Physical Data & Specifications
Air
R96V Series
Physical Data and Specifications—Upflow Models
U.S. and Canadian Models
MODEL NUMBERS |
R96VA0402317MSA |
R96VA0602317MSA |
R96VA0702317MSA |
R96VA0852521MSB |
R96VA1002521MSA |
R96VA1152524MSA |
||||
HIGH FIRE INPUT BTU/HR [kW] |
42,000 [12.31] |
56,000 |
[16.41] |
70,000 |
[20.50] |
84,000 [24.61] |
98,000 |
[28.72] |
112,000 [32.82] |
|
LOW FIRE INPUT |
29,400 [8.61] |
39,200 |
[11.49] |
49,000 |
[14.36] |
58,800 [17.23] |
68,600 |
[20.11] |
78,400 [23.00] |
|
HEATING CAPACITY BTU/HR [kW] |
40,320 [11.82] |
53,760 |
[15.75] |
67,200 |
[19.68] |
80,640 [23.63] |
94,080 |
[27.57] |
107,520 [31.51] |
|
HIGH ALTITUDE OUTPUT |
36,288 [10.64] |
48,384 |
[14.18] |
60,480 |
[17.72] |
72,756 [21.27] |
84,672 |
[24.81] |
96,768 [28.36] |
|
10% DERATE [kW] |
||||||||||
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
||||
BLOWER (D x W) |
11 x 7 |
11 x 8 |
11 x 8 |
11 x 10 |
11 x 10 |
11 x 11 |
||||
[mm] |
[279 x 178] |
[279 x 203] |
[279 x 203] |
[279 x 254] |
[279 x 254] |
[279 x 279] |
||||
MOTOR H.P. [W]– |
1/2 [373] E.C.M. |
1/2 [373] E.C.M. |
1/2 [373] E.C.M. |
3/4 [559] E.C.M. |
3/4 [559] E.C.M. |
3/4 [559] E.C.M. |
||||
TYPE |
||||||||||
|
|
|
|
|
|
|
|
|
||
MOTOR FULL LOAD AMPS |
8.9 |
8.9 |
8.9 |
10.8 |
10.8 |
10.8 |
||||
MINIMUM EXT. STATIC PRESSURE |
.18 [.045] |
.20 [.050] |
.23 [.057] |
.28 [.070] |
.28 [.070] |
.28 [.070] |
||||
(IN. W.C.) [kPa] |
||||||||||
|
|
|
|
|
|
|
|
|
||
MAXIMUM EXT. STATIC PRESSURE |
1.0 [0.249] |
1.0 [0.249] |
1.0 [0.249] |
1.0 [0.249] |
1.0 [0.249] |
1.0 [0.249] |
||||
(IN. W.C.) [kPa] |
||||||||||
|
|
|
|
|
|
|
|
|
||
HEATING CFM @ .2" [.049 kPa] |
1050 [496] |
1025 |
[484] |
1015 |
[479] |
1470 [694] |
1710 |
[807] |
1450 [684] |
|
W.C. E.S.P. [L/s] |
||||||||||
|
|
|
|
|
|
|
|
|
||
COOLING CFM @ .5" [.124 kPa] |
1050 [496] |
1050 |
[496] |
1050 |
[496] |
1750 [826] |
1750 |
[826] |
1750 [826] |
|
W.C. E.S.P. [L/s] |
||||||||||
|
|
|
|
|
|
|
|
|
||
TEMPERATURE RISE-HIGH FIRE |
20 - 50 |
30 - 60 |
40 - 70 |
30 - 60 |
40 - 70 |
45 - 75 |
||||
RANGE IN DEGREES °F [°C] |
[11 - 28] |
[17 - 33] |
[22 - 39] |
[17 - 33] |
[22 - 39] |
[25 - 42] |
||||
TEMPERATURE RISE-LOW FIRE |
15 - 45 |
20 - 50 |
30 - 60 |
20 - 50 |
30 - 60 |
35 - 63 |
||||
RANGE IN DEGREES °F [°C] |
[8 - 25] |
[11 - 28] |
[17 - 33] |
[11 - 28] |
[17 - 33] |
[19 - 36] |
||||
APPROX. SHIPPING WEIGHT |
128 [58] |
128 |
[58] |
132 |
[60] |
147.5 [67] |
152 |
[69] |
165 [75] |
|
(LBS.) [kg] |
||||||||||
|
|
|
|
|
|
|
|
|
||
AFUE |
96.00% |
96.00% |
96.00% |
96.00% |
96.00% |
96.00% |
NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T.Installation instructions for high altitude derate.
Canadian installations only.
In accordance with D.O.E. test procedures. *S=Standard Models
NOTE: Standard model complies with California low nox requirements.
[ ] Designates Metric Conversions
4