Gas Fireplaces
P40 Gas Fireplace
P40 Direct Vent Gas Fireplace
Model |
P40-NG1 |
P40-LP1 |
Fuel Type |
Natural Gas |
Propane |
|
|
|
Minimum Supply Pressure |
5” W.C. (1.25 kPa) |
12” W.C. (3.00 kPa) |
|
|
|
Manifold Pressure - High |
3.5” W.C. (0.87 kPa) |
10” W.C. (2.49 kPa) |
|
|
|
Manifold Pressure - Low |
1.6” W.C. (0.39 kPa) |
3.6” W.C. (0.89 kPa) |
|
|
|
Orifi ce Size - Front Burner |
#44 DMS |
#55 DMS |
|
|
|
Orifi ce Size - Rear Burner |
#35 DMS |
#53 DMS |
|
|
|
Minimum Input |
13,000 BTU/h (3.81 kW) |
12,000 BTU/h (3.51 kW) |
|
|
|
Maximum Input |
45,000 BTU/h (13.19 kW) |
43,000 BTU/h (12.60 kW) |
|
|
|
Vent Sizing |
5” Inner / 8” Outer |
5” Inner / 8” Outer |
|
|
|
Approved Venting Systems
Flex Vent Systems: |
FPI AstroCap™ Flex Vent |
Rigid Pipe Vent Systems: |
Simpson Dura-Vent® Direct Vent GS |
|
Selkirk Direct-Temp |
B
A
C |
D |
|
F |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
|
|
E |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
||||
Unit Dimensions |
Description |
|
|
|
|
P40 |
|||||||
|
|
|
|
|
|
|
|
|
|
||||
A |
Front Face Width |
|
|
|
|
40” (1016mm) |
|||||||
B |
Rear Firebox Width |
|
|
|
|
33-7/16” (889mm) |
|||||||
C |
Front Face Height |
|
|
|
|
34” (864mm) |
|||||||
D |
Height w/ Standoff |
|
|
|
|
42-1/2” (1080mm) |
|||||||
E |
Unit Depth |
|
|
|
|
20-1/16” (508mm) |
|||||||
F |
Height to Vent |
|
|
|
|
35-1/4” (826mm) |
|||||||
|
|
|
|
|
|
|
|
|
|
||||
Framing Dimensions |
Description |
|
|
|
|
P40 |
|||||||
|
|
|
|
|
|
|
|
|
|
||||
G |
Framing Width |
|
|
|
|
40-1/2” (1029mm) |
|||||||
H*** |
Framing Height*** |
|
|
|
42-1/2” (1080mm)*** + Hearth |
||||||||
I |
Framing Depth |
|
|
|
|
20-1/16” (508mm) |
|||||||
J |
Corner Wall Length |
|
|
|
|
50-5/8” (1286mm) |
|||||||
K |
Corner Facing Wall Width |
|
|
|
|
71-5/8” (1524mm) |
|||||||
L |
Minimum Height to Combustibles |
|
|
|
|
51-7/8” (1318mm) |
|||||||
M |
Vent Centerline Height |
|
|
|
|
45-3/8” (1153mm) |
|||||||
N |
Non-Combustible Facing Height |
|
|
|
|
10-1/4” (260mm) |
|||||||
O |
Gas Connection Height |
|
|
|
|
1-1/2” (38mm) |
|||||||
P |
Gas Connection Inset |
|
|
|
|
4-3/4” (121mm) |
|||||||
Q |
Gas Connection Width |
|
|
|
|
3-1/4” (102mm) |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Unit requires 120V to operate. See
“Wiring Diagram,” on page 17, for more details. Receptacle is included with manual.
L
|
Drywall |
|
|
(or other |
Top Header |
|
facing) |
|
|
|
(non-combustible) |
Top Header |
N |
|
(non-combustible) |
Non-Combustible Facing |
H
11" (279mm) dia. Hole through wall Vent.
G
I
M
J
O
P Q
K
Opening for gas connection
Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations.
***Important: Framing height requires consideration of the hearth depth. Dimension H = H + the thickness of installed hearth.
June 2007 Regency Product Specifications Book |
45 |
Fireplaces Gas
Gas Fireplaces
P40 Gas Fireplace
Framing and Finishing
1)Frame the enclosure for the unit with framing material. Use the determined total thickness of facing material (e.g. drywall plus ceramic tiles) to adjust the framing depth to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-1/4” (32mm) thick.
Note: Header for the P40 must be non combustible.
2)For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapor barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)
3)Ensure that all of the clearances listed below are met. Combustible material may be brought up to the sides of the unit and be covered with ceramic tiles, bricks, rock or other suitable combustible
fi nishing materials. Non-combustible facing is required above the unit. (See Dimension “N” on page 41)
Note: You must maintain proper clearances from the vent to combustible materials (See Below).
4)Use metal studs for framing where the minimum clearance from the vent to combustible material cannot be maintained.
Clearance Requirements
Required hearth must be non-combustible. (Page 43)
Required non-combustible facing above unit. (See Dimension “N” on page 41)
D
C
A
F
B
B
|
|
|
H |
|
||
|
|
|
|
|
|
|
|
I |
|
|
|
|
|
|
|
G |
|
|
E |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
Clearance: |
|
Dimension |
|
|
|
Measured From: |
A: Mantel Height |
|
12” (305mm) |
|
Minimum (Additional on this page) |
||
B: Sidewall |
|
8” (203mm) |
|
|
|
Side of installed front |
C: Ceiling |
|
39” (991mm) |
|
|
|
Top of installed unit |
D: Mantel Depth |
|
13” (330mm) |
|
Maximum (Additional on this page) |
||
E: Alcove Width |
|
56” (1422mm) |
|
Sidewall to Sidewall (Minimum) |
||
F: Alcove Depth |
|
36” (914mm) |
|
Front to back wall (Maximum) |
||
G: Hearth Height |
|
1-1/2” (39mm) |
|
Floor to top of Hearth. (Hearth must |
||
|
|
|
|
not be higher than base of fi rebox.) |
||
H: Hearth Width |
|
40” (1016mm) |
|
|
Edge to Edge of Hearth |
|
I: Hearth Depth |
|
16” (406mm) |
|
|
|
Front of Hearth to Wall |
46 |
|
|
|
|
|
|
Gas Fireplaces
Vent Clearances |
Clearance Dimension |
Horizontal - Top |
2-1/2” (64mm) |
Horizontal - Side |
1-1/2” (38mm) |
Horizontal - Bottom |
1-1/2” (38mm) |
Vertical (Flex or Rigid) |
1-1/4” (32mm) |
WARNING
Failure to maintain required clearances is a major cause of chimney related fires. Installation of this fireplace must comply with these clearances.
Hearth Requirements
A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm).
All measurements are from the bottom of the unit. Therefor the bottom of the unit would be fl ush with the top of a non-combustible hearth or 4” above the surface of a combustible fl oor.
Floor Mounted Fireplace
Raised Fireplace
Full Screen Door Facing Requirements
10-1/4” Above Fireplace
6”
6”
WARNING: When installing the Full Screen Doors
The Full Screen Front requires additionalnoncombustiblefacing and non-combustible framing. Ensure the 10-1/4" above the fireplace, 6" on both sides and both the header and side studs are non-combustible materials. All other clearances, including mantel, remain the same.
June 2007 Regency Product Specifications Book
Gas Fireplaces
Combustible Mantels
Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.
Mantel Clearances
14 |
12 |
10 |
8 |
6 |
4 |
2 |
0 |
|
|
|
|
13" (330mm) |
|
|
|
||
|
|
|
|
|
|
|
|
Drywall |
|
|
|
|
8”(203mm) |
|
|
||
|
|
|
|
|
1" (25mm) |
Non-Combustible |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Header |
|
|
B |
|
C |
|
|
|
Non-Combustible |
|
|
|
|
|
D |
|
Facing |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
Standoff |
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
Top of
A Louvers
To Floor |
Side View |
|
Mantel Clearances |
A |
B |
C |
D |
Front |
33” (838mm) |
21” (356mm) |
17” (254mm) |
12” (178mm) |
|
|
|
|
|
Note: If desired a non-combustible mantel may be installed at a lower height.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
Mantel Leg Clearances
Combustible mantel leg clearances as per diagram below: Clearances are from the fi nished edge of the unit or installed front.
P40
Maximum
1-1/2” projection at 2” minimum clearance.
8” Side Wall
Mantelleg |
1-1/2" |
Mantelleg |
2" |
|
|
|
|
6” |
|
7¼” |
|
Allowable mantel leg |
|
|
|
projection. |
|
Regency Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P40 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P40 using a flexible vent.
June 2007 Regency Product Specifications Book
|
|
|
P40 Gas Fireplace |
FPI Kit # |
Length |
Contains: |
|
#946-618 |
6 Feet |
1) |
8” fl exible outer liner (Kit length) |
|
|
2) |
5” fl exible inner liner (Kit length) |
|
|
3) |
spring spacers (3) |
|
|
4) |
thimble (2) |
|
|
5) |
AstroCap termination cap (1) |
|
|
6) |
screws (12) |
#946-616 |
10 Feet |
||
|
|
7) |
tube of Mill Pac (1) |
|
|
8) |
plated screws (8) |
|
|
9) |
S.S. screws #8 x 1-1/2” drill point, (4) |
|
|
10) |
vinyl siding standoff |
|
|
|
|
Notes:
1)Liner sections should be continuous without any joints or seams.
2)Only Flex pipe purchased from Regency may be used for Flex installations.
3)Horizontal sections must be supported every 3 feet.
AstroCap XL
(Part# 946-623/P)
Wall Thimble (required in Canada only)
|
Vinyl Siding |
|
|
Standoff |
|
5” dia. flue pipe |
|
|
8" dia. |
spring spacer |
|
Flue pipe |
||
|
Snorkel Terminations
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building, 14inch and 36-inch tall Snorkel Terminations are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.
47
Fireplaces Gas