Job:
Engineer:
Contractor:
Hi Delta SS™- Type H
Space Heating/Hot Water Boiler
Models HD101-HD401
Prepared By: |
|
Date: |
|
|
|
|
|
|
Model: |
|
Indoor/Outdoor: |
|
|
MBTUH Input: |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TruSeal® Direct Vent |
|
|
Sealed Combustion Chamber |
|
|
100% Factory Fire Tested |
|
|
Efficiency: 84% |
|
|
Maximum Outlet Temperature: 240°F |
|
|
Minimum Non-condensing Inlet Temperature: 105°F |
|
|
Thermal Shock Proof Heat Exchanger |
|
|
Limited Twenty-year Thermal Shock Warranty |
|
|
Limited Ten-year Closed-System Heat Exchanger Warranty |
|
|
Status Display LED’s |
|
|
PolyTuf Powder Coated Cabinet |
|
|
No Combustible Floor Shield Required |
|
|
Fan-assisted – Ultra Low NOx (<20 ppm Nat.) |
Patent No. 7,044,124 |
|
Patented Burner Security Blanket |
||
|
Heat Exchanger
H Stamp
Headers
Cast Iron, Glass-lined – Standard
Bronze – Option A-1
ASME Inspected and Stamped 160 PSIG Working Pressure
National Board Approved
Finned Tubing
Copper – Standard
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone High Temp O-Rings
Pressure Relief Valve - ASME
45 PSIG - Standard
PSIG - Optional
Temperature and Pressure Gauge (shipped loose)
Flow Switch - Mounted
Left-hand Water (Standard)
Right-hand water – Optional A-6
Controls
120V, 60Hz, 1 Power Supply
120/24V 60Hz Transformer
100% Shutoff/Lockout
Hot Surface Ignition
Remote Flame Sensor
Fixed High Limit Control, Manual Reset
On/Off Power Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches (2)
Economaster Style Pump Relay
Gas Train
4” WC Minimum Pressure
Combination Valve
Firing Mode
Two-stage (H3) - Standard
On/Off (H4) - Optional
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.13/CSA 4.9
Burner
Two-stage
Ultra-low NOx (<20 ppm Nat.)
Construction
Indoor/Outdoor Construction
Slide-out Controls Tray
Front Controls Enclosed
PolyTuf Powder Coat Finish
TruSeal® Direct Vent
Integral Combustion Air Filter
Venting
Vent Termination Cap
Outdoor – Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical – Option D-20
Combustion Air - Ducted
Air Intake Elbow – Option D-16
Extractor – Optional
By others
Not required
Temperature Controls
B-3 1-Stage Controller, 100-200°F
(Loose)
B-6 2-Stage Controller, 130-230°F
(Loose)
B-21 TempTracker Digital Controller
4-Stage (loose)
B-26 TempTracker Digital Controller,
2-Stage (Mtd)
B-27 TempTracker Digital Controller,
|
|
|
|
2-Stage, O/D (Mtd) |
|||
B-28 On/Off Digital Controller, (Mtd) |
|||||||
|
|
|
|
Remote Controller |
|||
|
|
|
|
By others: |
|||
Options |
|
|
|
|
|
||
|
|
|
|
|
|||
F-10 |
Low Water Cut-off, Remote |
||||||
|
|
|
Probe |
|
|||
I-1 |
Adjustable High Limit Control, |
||||||
|
|
|
Auto Reset |
|
|||
P- |
|
|
Pump: |
|
|
HP, 120V, 1, 60 Hz |
|
|
|
|
|
Bronze |
|
Mounted |
|
|
|
|
|
Cast Iron |
Loose |
P- Cold Water Protection (See
1000.19)
S-__ Low and High Gas Pressure
Switches, Manual
Catalog No.: 2000.181B |
Effective: 12-29-09 |
Replaces: 09-01-09 |