XTherm- Type H

Heating Boilers

Models 1005-2005

96% Thermal Efficiency at Full Rate; Up to 99% at Part Load 100% Factory Fire Tested

Maximum Outlet Water Temperature: 225°F

Minimum Inlet Water Temperature: 50°F

Full Safety Diagnostics with History

Footprint: Less Than 10.8 ft2

Limited Twenty-Five-Year Thermal Shock Warranty

Limited Ten-Year Primary Heat Exchanger Warranty

Limited Ten-Year Secondary Heat Exchanger Warranty

Full Electronic Modulation, Constant Ratio 4:1 Turndown

Modulating Controller with LCD Display

Status Display Lights

 

Proudly Made in the USA

 

 

 

 

 

Heat Exchanger

Control (cont.)

Multi-Boiler Digital Temp Controllers

Headers

Cast Iron – Standard

Bronze – Option A-1

ASME H Stamped; 160 PSIG MAWP

National Board Listed

Fin Tubing

Copper – Standard

Cupro Nickel – Option A-3

ASME Powder-Coated Tube Sheet

Silicone High Temp O-Rings

ASME Pressure Relief Valve

60 PSIG – Standard

PSIG – Optional

150 PSI Air Vent, Auto

T&P Gauge, Shipped Loose

Stainless Steel Secondary Heat Exchanger

Stainless Steel Evaporator Plate

Boiler Pump: 120V, 1 , 60Hz;

Cast Iron – Standard

Bronze – Option

Control

120V, 60Hz, 1Ø, Power Supply

120/24V 60Hz Transformer

Ignition Module

3-Try – Standard

Single-Try – Option C-6

Hot Surface Ignition (HSI)

Remote Flame Sensor

Fixed High Limit, Manual Reset, 240°F

On/Off Power Switch

Flow Switch

Blocked Vent Pressure Switch

Combustion Air Proving Switch

Freeze Protection

Alarm Dry Contact

Pump Switch

Pump Time Delay

Diagnostics Panel with LCD Display, 2 lines, 20 characters

Modulating Temperature Control

Water Temperature Sensors (3)

Cold Water Protection

Blocked Condensate Switch

Burner

Ultra-Low NOx: Less than 20 PPM (Natural Gas Only)

Gas Train

Fuel

Natural Gas

Propane

Zero Governor Regulator

Dual-Seat Combination Valve

Electronic Modulating Firing Mode (H7)

Construction

Indoor/Outdoor Construction

Enclosed Front Controls

PolyTuf Powder Coat Finish

Rear Connections (Water, Gas, Vent, Electrical, Comb. Air, Cond. Drain)

Combustion Air Filter

Design Certified ANSI Z21.13/CSA 4.9

Front Connection Low Voltage IWiring

Venting

Vent Termination, Cat IV

Outdoor or Indoor, Vertical –

Option D-11

Indoor, Horizontal – Option D-15

Extractor – Optional, Cat II

By others

Not required

B-36 TempTracker Mod+ Hybrid,

2-4 Boilers, OA Reset

B-37 TempTracker Mod+ Hybrid,

5-10 Boilers, OA Reset

B-38 TempTracker Mod+ Hybrid,

11-16 Boilers, OA Reset

B-45 Multi-Mod Platinum,

2-4 Boilers, OA Reset

B-46 Multi-Mod Platinum EMS,

2-4 Boilers, OA Reset

B-47 Multi-Mod Platinum BACNet,

2-4 Boilers, OA Reset

B-48 Multi-Mod Expansion Module,

1-8 Additional Boilers

Options

D-32 PVC Vent Adapter

(Includes 200ºF Manual High Limit) Maximum return water temperature allowed 170ºF.

F-10 Low Water Cut-Off, Remote Probe

I-1 High Limit, Auto Reset, Adj., 100-240°F

I-2 High Limit, Manual Reset, Adj., 100-240°F

S-1 Low Gas Pressure Switch, Manual Reset

S-2 High Gas Pressure Switch, Manual Reset

Z-12 Condensate Neutralizer Kit

Regulatory Agency Requirements

Catalog No.: 2000.61C

Effective: 12-01-10

Replaces: 07-10-09