Models: PM 13, PM 13S, PM 13W, PM 20, PM 20C, PM 20S, PM 20W , PM 27, PM 27C, PM 27S, PM 27W
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, call Peerless customer service at 1-800-729-0307.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never mount this product to a metal stud wall construction unless the stud can be verified to be constructed of 25 gauge steel minimum, the drywall is 1/2" thick minimum and you obtain and use the Peerless accessory kit for metal studs.
• Never exceed the Maximum UL Load Capacity .
• If mounting to wood wall stud wall construction, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws and nuts firmly , but do not overtighten. Overtightening can damage the items, greatly reducing their holding power. See suggested torque values where applicable within these instructions.
IMPORT ANT! Certain types of walls require additional mounting hardware...
WALL CONSTRUCTION ADDITIONAL HARDW ARE REQUIRED
Wood Stud, Wood Beam none Solid Concrete, Cinder Contact Customer Service for accessory kit
Block unless you have a PM 20C or PM 27C which
includes concrete fasteners
Metal Stud (Attachment to Do not attach except with Peerless accessory kit metal studs has not been for metal studs; Contact Customer Service for evaluated by UL and the Peerless accessory kit for metal studs. product is not UL listed if attached to metal studs.)
Other or unsure? Contact Customer Service
PM 13, PM 13S, PM 13W
PM 20, PM 20C, PM 20S, PM 20W
PM 27, PM 27C, PM 27S, PM 27W
The Maximum UL Load Capacity for this product is rated up to 13" TV, 125 lb
The Maximum UL Load Capacity for this product is rated up to 20" TV , 125 lb
The Maximum UL Load Capacity for this product is rated up to 27" TV , 125 lb
C
D
E
B
A
F
G
H
E
I
K
J
L
Before you start make sure all of the parts shown are included with your product. See page
5 for a complete parts list.
M
N
1 of 12
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 07-17-96 SHEET #: 170-9001-7 10-26-04
PLAN AHEAD! If you wish to mount TV as close to ceiling as possible measure TV height and use dimensions provided to calculate dimension X.
3" (76 mm)
X
13" (330 mm) *
16.5" (419 mm) * *
* PM 13, PM 13S, PM 13W, PM 20, PM 20S, PM 20W , PM 20C
** PM 27, PM 27S, PM 27W, PM 27C, PM 27WC
5/32" (4 mm)
B
A
3/8" (10 mm)
F
For Wood Stud Walls (for concrete skip to step 4) drill three 5/32" (4 mm) dia. holes 2 1/2" (65 mm) deep. Attach wall bracket (F) using #14 x 2.5 (6 mm x 65 mm) wood screws (A) and plastic bushings (B).
BE SURE TO DRILL INTO STUD CENTERS!
WARNING
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power .
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended.
2 of 12
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 07-17-96 SHEET #: 170-9001-7 10-26-04
WARNING
• If your model does not include concrete fasteners, contact customer service for the appropriate accessory kit to install the product on concrete or cinder block.
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete surface in the 5/16" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity .
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor .
• Make sure that the wall will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum UL Load Capacity .
For attachment to solid concrete or cinder block wall drill, 5/16" (8
mm) dia. holes 1.75" (45 mm) deep using a standard drill and masonry bit (DO NOT use a hammer drill). Attach wall bracket (F) using Concrete Anchor Kit as pictured below.
Tighten to 80 in. lbs. (9 N.M.) maxi­mum torque.
5/16" (8 mm)
5/16" (8 mm)
F
Insert and hammer in anchor.
Tighten to 80 in. lbs. (9 N.M.) maximum torque. The anchor will expand and grip inside the hole.
WARNING
• Tighten concrete anchor bolt firmly , but do not over­tighten. Overtightening can damage the bolt, greatly reducing its holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
FF
WARNING
• Always attach concrete expansion anchors directly to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing mate­rial. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored.
FINISHING SURFACE
F
CONCRETE
O
3 of 12
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 07-17-96 SHEET #: 170-9001-7 10-26-04
E
C
C
C
Complete the wall mount assembly as shown. Note: If install­ing a VCR mount refer
to that instruction before completing this step.
Choose from one of three tilt positions.
J
E
Snap bushings (E) into wall bracket (F).
F
F
K
Insert support arm (K) into wall bracket (F), then insert support arm retainer (C).
11/16"
(17 mm)
G H
I
D
K
Join support arm (K) and support arm retainer (C) with retainer pin (D). Note: A gentle tap with a hammer may be necessary to insert retainer pin (D).
F
K
Support arm retainer (C) will hold support arm (K) in place on wall bracket (F).
K
L
0
0
0
5
0
10
M
N
K
N
4 of 12
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
ISSUED: 07-17-96 SHEET #: 170-9001-7 10-26-04