Installation and Assembly - Universal Articulating |
Models: PLAV70-UNL, |
||
PLAV70-UNL-S, PLAV70-UNLP, |
|||
Swivel Double-Arm for 42" - 65" Plasma Screens |
|||
PLAV70-UNLP-S |
|||
|
|||
|
|
|
|
|
|
|
Max UL Load Capacity:
200 lb (91 kg)
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerless-av.com
ISSUED: 06-05-06 SHEET #: 202-9142-9 (2013-10-01)
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
•Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
•This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
•Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
•Never exceed the Maximum Load Capacity. See page one.
•If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud finder is highly recommended.
•Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
•Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
•This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
•This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION |
HARDWARE REQUIRED |
|
• |
Wood Stud |
Included |
• |
Wood Beam |
Included |
• |
Solid Concrete |
Included |
• |
Cinder Block |
Included |
• |
Metal Stud |
Do not attach except with Peerless Metal Stud Accessory Kit - ACC415; |
|
|
(not evaluated by UL) |
• |
Brick |
Contact Qualified Professional (not evaluated by UL) |
• |
Other or unsure? |
Contact Qualified Professional |
Tools Needed for Assembly
•stud finder ("edge to edge" stud finder is recommended)
•drill
•7/32" drill bit for wood studs
•3/8" masonry drill bit for concrete
•7/16" socket wrench with extension (recommended)
•level
•phillips screwdriver
•3/4" open-end wrench
Accessories
• External Wall Plate (WSP716, WSP716-S, WSP724, WSP724-S) (Metal Stud not evaluated by UL)
Table of Contents |
|
Parts List................................................................................................................................................................................. |
3 |
Installation to Double Wood Stud Wall ................................................................................................................................... |
5 |
Installation to Solid Concrete or Cinder Block ........................................................................................................................ |
6 |
2 of 14 |
ISSUED: 06-05-06 SHEET #: 202-9142-9 (2013-10-01) |
Wall Arm Parts List
|
|
|
PLAV70-UNL |
PLAV70-UNL-S |
|
|
|
PLAV70-UNLP |
PLAV70-UNLP-S |
|
Description |
Qty |
Part # |
Part # |
A |
wall plate |
1 |
201-1040 |
201-4040 |
B |
tilt-roll assembly |
1 |
201-1042 |
201-4042 |
C |
arm assembly |
1 |
201-1044 |
201-4044 |
D |
wall support arm axle |
2 |
201-1041 |
201-1041 |
E |
vinyl trim |
3 |
600-1012 |
600-1012 |
F |
M10 x 1.5 x 15 mm screw |
8 |
520-9262 |
520-9262 |
G |
.062" nylon washer |
1 |
540-1074 |
540-1074 |
H |
tilt adjustment knob |
1 |
560-0108 |
560-0108 |
I |
carriage bolt 3/8"-16 x 3.25" |
1 |
520-1315 |
520-1315 |
J |
.062" delrin washer |
4 |
540-1070 |
540-1070 |
K |
#8-32 x .375" socket head screw |
2 |
520-1210 |
520-1210 |
L |
plastic finishing cap |
6 |
590-1123 |
590-1123 |
M |
holding pin |
2 |
580-1166 |
580-1166 |
N |
retainer plug |
2 |
590-1007 |
590-1007 |
O |
5/16 x 3" wood screw |
8 |
520-1243 |
520-1243 |
P |
.068" metal washer |
8 |
540-1063 |
540-1063 |
Q |
9/64" allen wrench |
1 |
560-9728 |
560-9728 |
R |
cable management clips |
8 |
590-1166 |
590-1166 |
S |
cable tie |
8 |
590-1168 |
590-1168 |
T |
36" polyester mesh sleeve |
2 |
600-1015 |
600-1015 |
U |
6 mm allen wrench |
1 |
560-9716 |
560-9716 |
V |
concrete anchor |
8 |
590-0321 |
590-0321 |
Some parts may appear slightly different than illustrated.
A |
B |
C |
DE F
G
H I
J
K L
M N |
O |
P |
R |
S |
T |
|
V |
|
|
U |
|
|
|
|
Q |
|
|
|
|
|
|
|
3 of 14 |
ISSUED: 06-05-06 SHEET #: 202-9142-9 (2013-10-01) |
Adapter Bracket Parts List |
|
|
|
||
|
|
PLAV70-UNL |
PLAV70-UNL-S PLAV70-UNLP |
PLAV70-UNLP-S |
|
Description |
Qty |
Part # |
Part # |
Part # |
Part # |
AA adapter bracket |
1 |
201-1110 |
201-4110 |
201-1110 |
201-4110 |
BB shallow adapter bracket |
2 |
201-1511 |
201-4511 |
201-1514 |
201-4514 |
CC allen wrench |
1 |
560-9646 |
560-9646 |
560-0072 |
560-0072 |
AA |
|
|
BB |
|
CC |
Phillips Adapter Bracket Fasteners
M5 x 12 mm (4) |
|
M6 x 12 mm (4) |
|
|
|
||
(520-1027) |
|
|
(520-1128) |
M8 x 12 mm (4) |
.75" spacer (4) |
||
|
|
|
|
|
(520-9571) |
||
M5 x 25 mm (4) |
|
|
(540-1059) |
||||
M6 x 25 mm (4) |
M8 x 25 mm (4) |
||||||
|
|||||||
|
(520-9543) |
|
|
||||
|
|
|
(520-1208) |
(520-1031) |
Multi-washer (4) |
||
|
|
|
|
||||
|
|
|
|
|
|
(580-1398) |
Security Adapter Bracket Fasteners
M5 x 12mm (4) |
M6 x 12mm (4) |
M8 x 12mm (4) |
|
|
|
(520-1064) |
(520-1050) |
|
(520-1724) |
|
.75" spacer (4) |
|
|
|
|
|
|
M5 x 25mm (4) |
M6 x 25mm (4) |
M8 x 25mm (4) |
(540-1059) |
||
|
(520-1122) |
|
(520-1211) |
|
|
|
|
(520-1101) |
Multi-washer (4) |
||
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
(580-1398) |
|
|
|
4 of 14 |
ISSUED: 06-05-06 SHEET #: 202-9142-9 (2013-10-01) |
Installation to Wood Stud Wall
WARNING
•Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
•Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
•Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.
•Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
1 |
Wall plate (A) can be mounted to two studs that are 16" apart. Use a stud finder to locate the edges of the studs. |
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each |
stud’s center. Place wall plate on wall as a template. The top mounting slots should be located .43" below the desired screen center. Level plate, and mark the center of the eight mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill eight 7/32" dia. holes 3" deep. Make sure that the wall plate is level, secure it using eight 5/16 x 3" wood screws (O) and washers (P).
Skip to step 2 on page 7.
A
P
O
5 of 14 |
ISSUED: 06-05-06 SHEET #: 202-9142-9 (2013-10-01) |