Mitsubishi MCFH-A12WV- E1 (WH), MCFH-A18WV- E1 (WH), MCFH-A24WV- E1 (WH) Service Manual

SERVICE MANUAL
FLOOR AND CEILING TYPE AIR CONDITIONERS
Wireless type Models
(WH)
MCFH-A12WV­MCFH-A18WV-
E1
E1
(WH)
Revision A:
Power input of SPECIFICATION has modified.
Model name of remote controller has been
added to PARTS LIST.
Please void OB336.
No. OB336
REVISED EDITION-A
MCFH-A24WV-
Indication of model name
MCFH-A12WV­MCFH-A18WV­MCFH-A24WV-
E1
(WH)
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················2
3. SPECIFICATION·················································4
4. NOISE CRITERIA CURVES·······························5
E1
5. OUTLINES AND DIMENSIONS·························6
E1
6. WIRING DIAGRAM ············································7
E1
7. REFRIGERANT SYSTEM DIAGRAM················8
8. SERVICE FUNCTIONS ······································9
9. TROUBLESHOOTING ······································11
10. DISASSEMBLY INSTRUCTIONS·····················19
11. PARTS LIST ······················································21
12. OPTIONAL PARTS ···········································23
NOTE:
• This manual describes technical data of indoor units
• As for outdoor units MUCFH-A18/A24WV- , refer to the service manual OB337 REVISED EDITION-A.
• As for outdoor unit MUH-A12YV- , refer to the service manual OB331 REVISED EDITION-A.
• As for outdoor units MXZ-A18/A26/A32WV- , refer to the service manual OB319.
E1
E1
E1
(When installed on the floor)
(When the air inlet grille is opened.)
Deodorizing filter (gray sponge type)(option)
Air filter
Air inlet
Operation section
Air cleaning filter (white bellows type)(option)
Front panel
Receiving section
Operation indicator lamp
Horizontal vane
Vertical vanes
Emergency operation switch
(When installed on the ceiling)
ACCESSORIES
Item
Installation plate Unit fixing screw 5 o 12mm Wireless remote controller Remote controller mounting hardware Fixing screw for
3.5 o 16mm (Black) Battery (AAA) for remote controller Drain hose Drain pipe cover Knockout cover Screw for 4 o 10mm
2 2
1
1 2 2
1 1 1 2
Q'ty
Remote controller
Revision A:
•Power input of SPECIFICATION has modified.
•Model name of remote controller has been added to PARTS LIST.
1
MCFH-13NV- MCFH-A12WV-
1. Rated voltage has changed. (220-240V ➔ 230V)
2. Indoor electronic control P.C. board has changed.
3. Horizontal vane has changed.
4. Terminal block has changed.
5. Indoor heat exchanger has changed.
6. Remote controller has changed. Econo cool operation has been added.
7. Indoor fan motor has changed. (RB4V25-AB RB4V25-AC)
MCFH-24NV- MCFH-A24WV-
1. Rated voltage has changed. (220-240V ➔ 230V)
2. Indoor electronic control P.C. board has changed.
3. Horizontal vane has changed.
4. Terminal block has changed.
5. Indoor heat exchanger has changed.
6. Remote controller has changed. Econo cool operation has been added.
7. Liquid of union has changed. ({9.52 {6.35)
8. Indoor fan motor has changed. (RB4V36-AB RB4V36-DB)
2
TECHNICAL CHANGES
E1E4
E1E3
PART NAMES AND FUNCTIONS
MCFH-18NV- MCFH-A18WV-
1. Rated voltage has changed. (220-240V ➔ 230V)
2. Indoor electronic control P.C. board has changed.
3. Horizontal vane has changed.
4. Terminal block has changed.
5. Indoor heat exchanger has changed.
6. Remote controller has changed. Econo cool operation has been added.
7. Gas of union has changed. ({15.88 {12.7)
8. Indoor fan motor has changed. (RB4V36-AB RB4V36-AC)
E1E3
MCFH-A12WV - MCFH-A18WV - MCFH-A24WV -
INDOOR UNIT
E1E1E1
2
MCFH-A12WV -
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL
COOL
HEAT
DRY
PM
CLOCK
AM
RESET CLOCK
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Open the front lid.
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
TEMPERATURE buttons
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
ON-TIMER button
RESET button
ECONO COOL button
VANE CONTROL button
CLOCK SET button
HR. button
MIN. button
(TIME SET button)
Indication of remote controller model is on back.
MCFH-A18WV ­MCFH-A24WV -
REMOTE CONTROLLER
E1
E1
E1
3
3
Indoor model
Function
Power supply
Air flow(High/Med.W/LowW) Power outlet Running current Power input Auxiliary heater Power factor Fan motor current Model
Winding resistance(at20:)
Dimensions WOHOD Weight Air direction Sound level(High/Med.W/LowW) Fan speed(High/Med.W/LowW) Fan speed regulator Thermistor RT11(at25:) Thermistor RT12(at25:) Remote controller model
K /h
A A
W
A(kW)
%
A
"
mm
kg
dB
rpm
k" k"
Electrical
data
Fan
motor
Special
remarks
Capacity
MCFH-A12WV-
E1
MCFH-A18WV-
E1
MCFH-A24WV-
E1
Cooling
Heating
780/636W/492W
10
0.30 66
96
0.30
RB4V25-AC
WHT-BLK 182.2 BLK-YLW 68.9
YLW-BLU 47.5 BLU-BRN 31.5
BRN-RED 22.9
25
5
46/41W/36W
1,240/1,060/845
3 10 10
KG04C
Cooling
Heating
Single phase
230V, 50Hz
840/696W/570W
10
0.36 80
97
0.36
RB4V36-AC WHT-BLK 82.9 BLK-YLW 65.6 YLW-BLU 36.0 BLU-BRN 27.0
BRN-RED 13.7
1100 650 180
25
5
48/44W/39W
1,320/1,145/960
3 10 10
KG04C
Cooling
Heating
840/744W/642W
10
0.36 80
97
0.36
RB4V36-DB WHT-BLK 84.0 BLK-YLW 46.2 YLW-BLU 37.2 BLU-BRN 45.2
BRN-RED 13.6
25
5
48/45W/42W
1,320/1,190/1,060
3 10 10
KG04C
SPECIFICATION
NOTE: Test conditions are based on ISO 5151
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C WB 15°C
Outdoor DB35°C WB(24°C) Outdoor DB 7°C WB 6°C
Indoor-Outdoor piping length : 5 m
w Reference value
4
4
NOISE CRITERIA CURVES
MCFH-A12WV -
E1
SPL(dB
SPEED
High
(A)) LINE
46
Test conditions, Cooling : DB 27: WB 19:\
90
Heating : DB 20: WB 15:
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF HEARING FOR CONTINUOUS NOISE
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
10
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
MCFH-A18WV -
E1
SPL(dB
SPEED
High
(A)) LINE
48
Test conditions, Cooling : DB 27: WB 19:\
90
Heating : DB 20: WB 15:
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF HEARING FOR CONTINUOUS NOISE
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
10
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
MCFH-A24WV -
E1
SPL(dB
SPEED
High
(A)) LINE
48
Test conditions, Cooling : DB 27: WB 19:\
90
Heating : DB 20: WB 15:
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF HEARING FOR CONTINUOUS NOISE
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
10
63 125 250 500 1000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
INDOOR UNIT
MICROPHONE
1m
1m
WALL
5
5
(When installed on the floor)
(When installed on the ceiling)
50cm or more
50cm or more
50cm or more
50cm or more
100cm or more
650
616.5
80.8 906 112.8
114
16
1100
93
77
113
143
180
17042.5
12.7 (MCFH-A12/A18WV)
15.88 (MCFH-A24WV)
Gas line
6.35
Liquid line
Wireless remote controller
162
19
58
OUTLINES AND DIMENSIONS
MCFH-A12WV ­MCFH-A18WV ­MCFH-A24WV -
INDOOR UNIT
E1
E1
E1
Unit: mm
6
WIRING DIAGRAM6
SYMBOL
SR141~SR143
TB1, TB2
X144
SYMBOL
MV NR11 RT11 RT12
NAME
NAME NAME INDOOR FAN CAPACITOR FUSE (3.15A) DC/DC CONVERTER INDOOR FAN MOTOR(INNER FUSE)
VANE MOTOR VARISTOR ROOM TEMPERATURE THERMIST OR INDOOR COIL THERMISTOR
SOLID STATE RELAY TERMINAL BLOCK RELAY
1.About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
2.Use copper conductors only. (For field wiring)
3.Symbols below indicate. : Connector
: Terminal block
NOTES:
SYMBOL
C11
F11
HIC1
MF
MCFH-A12WV ­MCFH-A18WV ­MCFH-A24WV -
INDOOR UNIT
POWER SUPPLY
~/N 230V
50Hz
CIRCUIT BREAKER
TO OUTDOOR UNIT CONNECTING 12V
E1
MODELS WIRING DIAGRAM
E1
E1
TB1
PE
N
L
GRN/YLW
BLU RED
1 2 3
CN201
BRN
TB2
BLU
N
CN CN CN
3
113 151101
5
5
REMOTE CONTROLLER
DISP/ RECEIVER P.C.BOARD
TAB12
6 5
4
MV
SW/THERMO P.C.BOARD
HIC1
LDCOM
C11
TRANS
F11
ELECTRONIC CONTROL P.C BOARD
RT11
NR11
X144 SR143
SR142 SR141
CN
112
LDC11 LDC12 LDFH LDFM LDFL LDFVL
2
2
WHT ORN RED BLK YLW BLU BRN
WHT
1
ORN
2
RED
3
BLK
4
YLW
5
BLU
6
BRN
7 8
GRN/YLW
RT12
MF
7
REFRIGERANT SYSTEM DIAGRAM7
MCFH-A12WV-
INDOOR UNIT
E1
Refrigerant pipe [12.7 (with heat insulator)
MCFH-A18WV-
INDOOR UNIT
Unit : mm
E1
Refrigerant pipe [12.7 (with heat insulator)
Indoor heat exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
Distributor
MCFH-A24WV-
Flared connection
Flared connection
Refrigerant pipe [6.35 (with heat insulator)
E1
Indoor heat exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
Distributor
Flared connection
Flared connection
Refrigerant pipe [6.35 (with heat insulator)
INDOOR UNIT
Indoor heat exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
Distributor
Refrigerant pipe [15.88 (with heat insulator)
Flared connection
Flared connection
Refrigerant pipe [6.35 (with heat insulator)
Refrigerant flow in cooling Refrigerant flow in heating
8
Loading...