M360
Blackbody Calibration Source
MANUAL
Confidential Information
The material contained herein consists of information that is the property of LumaSense Technologies and intended solely for use by the purchaser of the equipment described in this manual. All specifications are subject to change without notice. Changes are made periodically to the information in this publication, and these changes will be incorporated in new editions.
LumaSense Technologies prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual, without the express written permission of LumaSense Technologies.
Copyright
© LumaSense Technologies 2014. All rights reserved.
Trademarks
Mikron is a trademark of LumaSense Technologies.
All other trademarks are trademarks, registered trademarks, and/or service marks of their respective holders.
|
Service Centers |
LumaSense Technologies, Inc. |
LumaSense Technologies GmbH |
North America |
Other Than North America |
Sales & Service |
Sales & Support |
Santa Clara, CA, USA |
Frankfurt, Germany |
Ph: +1 800 631 0176 |
Ph: +49 (0) 69 97373 0 |
Ph: +1 408 727 1600 |
Fax: +49 (0) 69 97373 167 |
Fax: +1 408 727 1677 |
|
Global and Regional Centers
Our Headquarters |
Americas, Australia, & Other Asia |
Europe, Middle East, Africa |
LumaSense Technologies, Inc. |
LumaSense Technologies, Inc. |
LumaSense Technologies GmbH |
Santa Clara, CA, USA |
Santa Clara, CA, USA |
Frankfurt, Germany |
Ph: +1 800 631 0176 |
Ph: +1 800 631 0176 |
Ph: +49 (0) 69 97373 0 |
Fax: +1 408 727 1677 |
Fax: +1 408 727 1677 |
Fax: +49 (0) 69 97373 167 |
Brazil |
India |
China |
LumaSense, Vendas Brasil |
LumaSense Technologies, India |
LumaSense Technologies, China |
Campinas, Brasil |
Mumbai, India |
Shanghai, China |
Ph: +55 19 3367 6533 |
Ph: + 91 22 67419203 |
Ph: +86 133 1182 7766 |
Fax: +55 19 3367 6533 |
Fax: + 91 22 67419201 |
Fax: +86 21 5877 2383 |
E-mail info@LumaSenseinc.com support@LumaSenseinc.com eusupport@LumaSenseinc.com supportdk@LumaSenseinc.com
Website http://www.LumaSenseinc.com
Part No 11180-43 EN
Revision J
August 2014
Contents
1 |
General Information...................................................................................................... |
5 |
||
|
1.1 |
Information about the user manual..................................................................... |
5 |
|
|
|
1.1.1 |
Legend ................................................................................................................. |
5 |
|
1.2 |
Safety |
..................................................................................................................... |
5 |
|
|
1.2.1 |
Safety Notifications/Warnings ............................................................................. |
5 |
|
1.3 |
Limit of ............................................................................Liability and Warranty |
6 |
|
|
1.4 |
Unpacking ....................................................................................the Instrument |
6 |
|
|
1.5 |
Service .....................................................................Request, Repair, or Support |
6 |
|
|
1.6 |
Shipments ....................................................................to LumaSense for Repair |
7 |
|
|
1.7 |
Transport, ..................................................................................Packing, Storage |
7 |
|
|
1.8 |
Disposal ................................................................................./ decommissioning |
7 |
|
2 |
Introduction................................................................................................................... |
9 |
||
|
2.1 |
Description............................................................................................................. |
9 |
|
|
2.2 |
Technical .......................................................................................................Data |
9 |
|
|
2.3 |
Dimensions .......................................................................................................... |
10 |
|
3 |
Installation .............................................................................................& Operation |
13 |
||
|
3.1 |
Installation........................................................................................................... |
13 |
|
|
3.2 |
Operation............................................................................................................. |
13 |
|
|
|
3.2.1 ........................................................................................................ |
Starting Up |
13 |
|
|
3.2.2 ...................................................................................... |
Changing the Setpoint |
13 |
|
|
3.2.3 .................................................................................... |
Other Controller Modes |
14 |
|
|
3.2.4 .................................................................................................. |
Shutting Down |
14 |
|
|
3.2.5 ............................................................................ |
Using Serial Communications |
14 |
|
|
3.2.6 ....................................................................................... |
Controller Calibration |
16 |
|
|
3.2.7 ................................................Switch Comm Mode from Ei Bisync to Modbus |
18 |
|
Index .................................................................................................................................. |
|
|
19 |
|
Appendix A: CE ............................................................................................Certification |
21 |
M360 Manual |
Contents iii |
To ensure consistent document formatting, this page was intentionally left blank.
M360 Manual |
Contents iv |
Congratulations on choosing the high quality and highly efficient Mikron blackbody.
This manual provides important information about the instrument and can be used as a work of reference for installing, operating, and maintaining your blackbody. It is important that you carefully read the information contained in this manual and follow all safety procedures before you install or operate the instrument.
To avoid handling errors, keep this manual in a location where it will be readily accessible.
Note: The note symbol indicates tips and useful information in this manual. All notes should be read to effectively operate the instrument.
Warnings and Cautions: The general warnings and cautions symbol signifies the potential for bodily harm or damage to equipment.
This manual provides important information on safely installing and operating the
M360 blackbody. Several sections of this manual provide safety warnings to avert danger. These safety warnings are specified with a warning symbol. You must read and understand the contents of this manual before operating the instrument even if you have used similar instruments or have already been trained by the manufacturer.
It is also important to continually pay attention to all labels and markings on the instrument and to keep the labels and markings in a permanent readable condition.
Warning: The blackbody is only to be used as described in this manual. It is recommended that you only use accessories provided by the manufacturer.
In addition to presenting a potential fire hazard, high voltage and high temperature can damage equipment and cause severe injury or death. When using this instrument, follow all instructions carefully.
Do not use the M360 for any purpose other than the function for which it was designed: a blackbody radiance temperature source.
Only replace the power cable with an equal, approved cable.
Only remove cabinet covers after unplugging the unit.
Warning: High voltages and currents are present inside the enclosure.
Do not attempt to operate with any of the safety features bypassed or disconnected.
Do not place this unit where it will be subject to excessive shock, vibration, dirt, moisture, oil, or other liquids.
M360 Manual |
General Information 5 |
All general information and notes for handling, maintaining, and cleaning this instrument are offered according to the best of our knowledge and experience.
All Mikron blackbodies from LumaSense Technologies have a regionally effective warranty period. Please check our website at http://info.LumaSenseinc.com/warranty for up-to-date warranty information. This warranty covers manufacturing defects and faults which arise during operation, only if they are the result of defects caused by LumaSense Technologies.
The warranty is VOID if the instrument is disassembled, tampered with, altered, or otherwise damaged without prior written consent from LumaSense Technologies; or if considered by LumaSense Technologies to be abused or used in abnormal conditions.
When unpacking and inspecting your system components, you need to do the following: 1. Check all materials in the container against the enclosed packing list.
Note: LumaSense Technologies cannot be responsible for shortages against the packing list unless a claim is immediately filed with the carrier. Final claim and negotiations with the carrier must be completed by the customer.
2.Carefully unpack and inspect all components for visible damage.
3.Save all packing materials, including the carrier’s identification codes, until you have inspected all components and find that there is no obvious or hidden damage.
Note: Before shipment, each instrument is assembled, calibrated, and tested at the LumaSense Factory. If you note any damage or suspect damage, immediately contact the carrier and LumaSense Technologies, Inc.
Contact LumaSense Technologies Technical Support in case of a malfunction or service request. Provide clearly stated details of the problem as well as the instrument model nµmber and serial nµmber. Upon receipt of this information, Technical Support will attempt to locate the fault and, if possible, solve the problem over the telephone.
If Technical Support concludes that the instrument must be returned to LumaSense Technologies for repair, they will issue a Return Material Authorization (RMA) nµmber.
Return the instrument upon receipt of the RMA nµmber, transportation prepaid. Clearly indicate the assigned RMA nµmber on the shipping package exterior. Refer to Section 1.6, Shipments to LumaSense for Repair, for shipping instructions.
Technical Support can be contacted by telephone or email:
Santa Clara, California
Telephone: +1 408 727 1600 or +1 800 631 0176
Email: support@LumaSenseinc.com
Frankfurt, Germany
Telephone: +49 (0) 69 97373 0
Email: eusupport@LumaSenseinc.com
Erstein, France
Telephone +33 (0)3 88 98 98 01
M360 Manual |
General Information 6 |
Email: eusupport@LumaSenseinc.com
All RMA shipments of LumaSense Technologies instruments are to be prepaid and insured by LumaSense assigned shipper. For overseas customers, ship units air-freight, priority one.
The instrument must be shipped in the original packing container or its equivalent. LumaSense Technologies is not responsible for freight damage to instruments that are improperly packed.
Contact us to obtain an RMA nµmber (if one has not already been assigned by Technical Support). Clearly indicate the assigned RMA nµmber on the shipping package exterior.
Send RMA Shipments to your nearest technical service center:
Santa Clara, California |
Frankfurt, Germany |
LumaSense Technologies, Inc. |
LumaSense Technologies GmbH |
3301 Leonard Court |
Kleyerstr. 90 |
Santa Clara, CA 95054 USA |
60326 Frankfurt |
Telephone: +1 408 727 1600 |
Germany |
+1 800 631 0176 |
Telephone: +49 (0)69-97373 0 |
Email: support@LumaSenseinc.com |
Email: eusupport@LumaSenseinc.com |
|
|
With faulty shipping, the instrument can be damaged or destroyed. To transport or store the instrument, please use the original box or a box padded with sufficient shock-absorbing material. For storage in hµmid areas or shipment overseas, the device should be placed in welded foil (ideally along with silica gel) to protect it from hµmidity.
The blackbody is designed for a storage temperature of -20 to 80 °C with non-condensing conditions. Storing the instrument out of these conditions can cause damage or result in malfunction of the blackbody.
Inoperable Mikron blackbodies must be disposed of in compliance with local regulations for electro or electronic material.
M360 Manual |
General Information 7 |