La Crosse Technology WS8300 User Manual

WIRELESS 868 MHz TEMPERATURE
STATION
INTRODUCTION:
Congratulations on purchasing this compact 868MHz Temperature Station which displays the time, indoor temperature, and up to three outdoor temperature and humidity readings. With only two keys, easy to use, this product is ideal for home or office.
LCD Display

Instruction Manual

Hanging Hole
Battery compartment cover
Function Keys
Foldout stand
25
« Instant Transmission+» is the up and coming state­of-the-art new wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. “IT +” offers you an immediate update of all your outdoor data measured from the transmitters: follow your climatic variations in real-time!
FEATURES:

The Temperature Station

Quartz clock in 12 or 24-hour time display (hour and
minute, manually set)
Indoor and outdoor temperature reading in Celsius (°C)
or Fahrenheit (°F) degree
Outdoor humidity reading in %RH
Can receive up to three outdoor transmitters
Minimum and Maximum records of indoor temperature,
outdoor temperature and outdoor humidity
Wireless transmission at 868 MHz
26
Signal reception intervals every 4.5 seconds
Low battery indicator
Wall mountable or table standing (foldout table stand)

The Outdoor Thermo-Hygro Transmitter

SETUP:

When one transmitter is used

1. First, insert the batteries into the transmitter (see “How
2. Within 2 minutes of powering up the transmitter, insert
Remote transmission of outdoor
temperature and humidity to Temperature Station by 868 MHz signals
Shower proof casing
Wall mounting stand
to install and replace batteries in the Thermo-hygro transmitter” below).
the batteries into the Temperature Station (see “How to install and replace batteries in the Temperature Station below). Once the batteries are in place, all
segments of the LCD will light up briefly. The indoor temperature and the time as 0:00 will then be displayed. If they are not shown in LCD after 60
27
seconds, remove the batteries and wait for at least 60 seconds before reinserting them. Once the indoor data is displayed, user may proceed to the next step.
3. After the batteries are inserted, the Temperature Station will start receiving data signal from the transmitter. The outdoor temperature and humidity should then be displayed on the Temperature Station. If this does not happen after 2 minutes, the batteries will need to be removed from both units and the setup restarted from step 1.
4. In order to ensure an optimal 868 MHz transmission, in good conditions, the distance between the Temperature Station and the transmitter should not be no more than 100 meters (see notes on “Positioning” and “868 MHz Reception”).

When more than one transmitter is used

1. User shall remove all the batteries from the Temperature
Station and the transmitter and wait 60 seconds (if setup has been done with one transmitter before).
2. Insert the batteries into the first transmitter.
3. Within 2 minutes of powering up the first transmitter,
insert the batteries into the Temperature Station. Once the batteries are in place, all segments of the LCD will light up briefly. The indoor temperature and the tim e as 0:00 will then be displayed. If they are not shown in LCD after 60 seconds, remove the batteries and wait for at least 60 seconds before reinserting them.
28
4. The outdoor temperature and humidity from the first
transmitter (channel 1) should then be displayed on the Temperature Station. Also, the signal reception icon will be displayed. If this does not happen after 2 minutes, the batteries will need to be removed from both units and the setup restarted from step 1.
5. Insert the batteries to the second transmitter as soon as
the outdoor temperature and humidity readings from the first transmitter are displayed on the Temperature Station.
Note: User shall insert the batteries into the second transmitter within 30 seconds of reception of the first transmitter.
6. The outdoor temperature and humidity from the second
transmitter and the "channel 2" icon should then be displayed on the Temperature Station. If this does not happen after 2 minute, the batteries will need to be removed from all the units and the setup restarted from step 1.
7. Insert the batteries into the third transmitter as soon as
the "channel 2" icon and outdoor data are displa yed on the Temperature Station. Within 2 minutes, the channel 3 outdoor data from the third transmitter will then be displayed and the channel icon will shift back to "1" once the third transmitter is successfully recognized. If this is not happen, user shall restart the setup from step 1.
29
Note: User shall insert the batteries into the third transmitter within 30 seconds of reception of the second transmitter.
8. In order to ensure an optimal 868 MHz tr ansmission, in
good conditions, the distance between the Temperatu re Station and the transmitter should not be no more than 100 meters (see notes on “Positioning” and “868 MHz
Reception”).
HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION
The Temperature Station uses 2 x AA, IEC LR6, 1.5V batteries. When batteries will need to be replaced, the low battery icon will appear on the LCD. To install and replace th e batteries, please follow the steps below:
1. Lift up the battery compartment cover.
2. Insert batteries observing the correct polarity (see marking).
3. Replace the compartment cover.
30
HOW TO INSTALL AND REPLACE BATTERIES IN THE THERMO-HYGRO TRANSMITTER
The Thermo-Hygro transmitter uses 2 x AA, IEC LR6, 1.5V batteries. When batteries will need to be replaced, the low battery icon will appear on the LCD of the Temperature Station. To install and replace the batteries, please follow the steps below:
Note:
In the event of changing batteries in any of the units, need to be reset by following the setup procedures. A random security code is assigned by the transmitter at start-up and this code must be received and stored by the Temperature Station within the first 3 minutes of power supplying.
1. Lift up the rain protector of the transmitter and remove the battery cover.
2. Insert the batteries, observing the correct polarity (see marking).
3. Replace the rain protector and battery cover on the unit.
all units
31
BATTERY CHANGE:
It is recommended to replace the batteries in all units at least every 24-month to ensure optimum accuracy of these units.

FUNCTION KEYS:

Temperature Station:
The Temperature Station has only two function keys, easy to use.
MIN/MAX/+
key
Set/ch key (Setting/Channel)
Press and hold for about 3 seconds to enter the
Manual setting mode.
Used to toggle between the data of different outdoor
transmitters (channel) "1", "2" and "3", when mor e than 1 transmitter is used.
Please participate in the preservation of the environment. Return used batteries to an authorised depot.
SET/ CH key
32
Min/max/+ key (Min/ Max temperature)
Used to toggle between the minimum and maximum recorded readings of indoor & outdoor temperature and outdoor humidity.
LCD SCREEN AND SETTINGS:
Outdoor
Temp. in °C
Outdoor
humidity %RH
Receiver
*When the signal is successfully received by the Temperature Station, the Outdoor reception icon will be switched on. (If not successful, the icon will not be shown). The user can ther efore easily see whether the last reception was successful (icon
Low b
attery
ndicator
i
Transmitter Low battery indicator
Transmitter identification (channel No.)
Time
Indoor Temp. in °C
Outdoor Reception Signal icon*
33
“ON”) or not (icon “OFF”). On the other hand, the flashing of the icon shows that a reception is being done now.
For a better legibility, the LCD screen is split into 4 sections, displaying the information for time, indoor temperature, and outdoor data.
Section 1 - Outdoor temperature Section 2 - Outdoor humidity Section 3 - Time Section 4 - Indoor temperature
MANUAL SETTING:
12 / 24- HOUR TIME DISPLAY SETTING AND TEMPERATURE UNIT (°C/°F) SETTING
User may choose to display the time in 12-hour or 24-hour format :
Note:
When the time display is in 12-hour mode, the temperature unit will be set to °F; when the time mode is in 24-hour, the temperature unit will be set to °C.
1. In normal display mode, press and hold the “set/ ch” key for about 3 second. The "12h" or "24h" digit will be flashing.
2. Press the “min/max/+” key to set the desired time display format.
34
3. Press shortly the “set” key to advance to the MANUAL TIME SETTING.
MANUAL TIME SETTING
User shall manually set the time of Temperature Station by the following steps:
1. The hour digit of the time display will be flashing.
2. Press the “min/max/+ “key to adjust the hour. Press “set” key to confirm and go to the minute setting.
3. The minute digit will be flashing. Press the “min/ma x/+” key to adjust the minute. Press “set” key once more to return to normal display.
VIEWING THE MINIMUM AND MAXIMUM READINGS :
User may view the minimum and maximum temperature and humidity data records of the indoor or outdoor channels by following these steps :
1. In normal display, press “set/ch” key to choose the
desired channel (transmitter).
2. Press the “min/max/+” key once to view the minimum
indoor temperature, minimum outdoor temperature and minimum outdoor humidity of the selected channel.
35
Minimum icon
3. Press the “min/max/+” key once more to view the
maximum indoor temperature, maximum outdoor temperature and maximum outdoor humidity of the selected channel.
Maximum icon
36
Selected channel No.
Selected channel No.
RESETTING THE MINIMUM AND MAXIMUM READINGS :
User may reset the minimum and maximum temperature and humidity data to the current value by following this step :
1. Press and hold the “min/max/+” key for about 3 seconds to reset all the minimum/ maximum data of all channels and the indoor sensor to the current values in a single action.
THERMO-HYGRO TRANSMITTER :
The outdoor temperature and humidity are measured and transmitted every 4.5 seconds. The range of the Thermo-Hygro transmitter may be affected by the temperature : at cold temperatures, the transmitting distance may be decreased. Please bear this in mind when placing the transmitter.

868 MHz RECEPTION CHECK

The Temperature Station should receive the temperature and humidity data within a few minutes after setup. If the temperature and humidity data is not received 5 minutes after setup (the display shows “- - -” after consecuti ve failures in receiving signal), please check the following points :
1. The distance of the Temperature Station or transmitter
should be at least 1.5 to 2 meters away from any interfering sources such as computer monitors or TV sets.
37
2. Avoid positioning the Temperature Station onto or in the
immediate proximity of metal window frames.
3. Using other electrical products such as headphones or
speakers operating on the same signal frequency (868MHz) may prevent correct signal transmission and reception.
4. Neighbours using electrical devices operating on the
868MHz signal frequency can also cause interference.
Note:
When the 868MHz signal is received correctly, do not re-open the battery cover of either the transmitter or Temperature Station, as the batteries may spring free from the contacts and force a false reset. Should this happen accidentally, reset all units (see “Setup” above), otherwise transmission problems may occur. The transmission range is about 100 m from the transmitter to the Temperature Station (in open space). However, this depends on the surrounding environment and interference levels. If no reception is possible despite the observation of these factors, all system units have to be reset (see “Setup”).
POSITIONING THE TEMPERATURE STATION :
The Temperature Station comes attached with a foldout table stand, which provides the option of table standing or wall mounting the unit. Before wall mounting, please check that th e outdoor temperature and humidity values can be received from the desired locations.
38
To attach to the wall, please follow the steps below :
1. Fix a s crew (not supplied) into the desired wall, leaving the head extended out by about 5mm.
2. Hang the Temperature Station onto the screw. Remember to ensure that it locks into place before releasing.

POSITIONING THE THERMO-HYGRO TRANSMITTER

The Thermo-hygro transmitter is supplied with a holder that may be attached to a wall with the two screws supplied. Bef ore securing the transmitter, ensure that the 868MHz signal is properly received. To attach to the wall, please follow the steps below :
1. Mark the wall using a pen through the holes in the holder to obtain the exact drilling position.
2. Drill holes in the wall at the marked points.
3. Screw the holder onto wall.
39
User may also use the double sided tape to install the transmitter onto the wall. On smooth surfaces this can be used instead of drilling holes. However, the mounting surface can affect the transmission range. If, for instance, the transmitter is attached to a piece of metal, it may then either reduce or increase the transmitting range. For this reason, we recommend not to place the transmitter on any metal surfaces or in any position where a large metal or highly polished surface is in the immediate vicinity (garage doors, double glazing, etc.). Before securing in place, please ensure that the Temperature Station can receive the 868MHz signal from the Thermo-hygro transmitter at the positions that you wish to place them.
CARE AND MAINTENANCE:
Extreme temperatures, vibrations a nd shocks should be
When cleaning the display and casing s, use a soft dam p
Do not submerge the unit in water. Furthermore, fix all
Immediately remove all low powered batteries to avoid
avoided as these may cause damage to the unit and give inaccurate forecasts and readings.
cloth only. Do not use solvents or scouring agents as they may mark the LCD and casings.
parts in place where the unit is adequately protected against moisture and rain.
leakage and damage. Replace only with new batteries of the recommended type.
40
Do not make any repair attempts to the unit. Return
them to their original point of purchase for repair by a qualified engineer. Opening and tampering with the unit may invalidate their guarantee.
Do not expose the units to extreme and sudden
temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS:
Temperature measuring range Indoor : -9.9ºC to +59.9ºC with 0.1ºC resolution (“OFL” displayed if outside this range) Outdoor : -39.9ºC to +59.9ºC with 0.1ºC resolution (“OFL” displayed if outside this range)
Outdoor Humidity measurement : from 1 to 99% (Displays "1%" when 1%; displays "99%" when 99%)
Indoor Temperature checking interval : every 15-second Outdoor data checking inerval : every 4.5-second
Power Supply Temperature Station : 2 x AA, IEC LR6, 1.5V Outdoor Thermo-hygro Transmitter : 2 x AA, IEC LR6, 1.5V
41
Battery life cycle : approximately 24 months (Alkaline batteries recommended)
Dimensions (L x W x H) Temperature Station : 147.1 x 23.6 x 139.1 mm Outdoor Thermo-hygro Transmitter : 57.3 x 62 x 135.6 mm
LIABILITY DISCLAIMER:
The electrical and electronic wastes contain hazardo us
substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment.
Please contact your local or/and regional authorities to
retrieve the addresses of legal dumping grounds with selective collection.
All electronic instruments must from now on be
recycled. User shall take an active part in the reuse, recycling and recovery of the electrical and electronic waste.
The unrestricted disposal of electronic waste may do
As stated on the gift box and labeled on the product,
The manufacturer and supplier cannot accept any
harm on public health and the quality of environment. reading the “User manual” is highly recommended f or
the benefit of the user. This product must however not be thrown in general rubbish collection points.
responsibility for any incorrect readings and any
42
consequences that occur should an inaccurate reading take place.
This product is designed for use in the home only as
indication of the temperature and/or other weather data.
This product is not to be used for medical purposes or
for public information.
The specifications of this product may change without
prior notice. This product is not a toy. Keep out of the reach of children. No part of this manual may be reproduced without written authorization of the manufacturer.
R&TTE Directive 1999/5/EC
Summary of the Declaration of Conformity : We hereby declare that this wireless transmission device does comply with the essential requirements of R&TTE Directive 1999/5/EC.
43