KEYENCE SL-T11R User Manual

96M00294
Installation environment
Dedicated Relay Terminal for SL-V
SL-T11R
Instruction Manual

Introduction

This instruction manual describes handling, operation, and precautionary information for the SL-T11R dedicated Relay Terminal for the SL-V Series Safety Light Curtain ("SL-V"). Read this instruction manual thoroughly before operating the SL-T11R along with the SL-V Instruction Manual in order to understand the features and functions of the SL-T11R, and keep this instruction manual readily available for reference. Ensure that the end user of this product receives this manual.
Safety Headings
Danger
Caution
NOTE
Reference

Safety Precautions

General Precautions
• You must verify that the SL-T11R is operating correctly in terms of functionality and performance before starting the machine and operating the SL-T11R.
• KEYENCE does not guarantee the function or performance of the SL-T11R if it is used in a manner that differs from the SL-T11R specifications contained in this instruction manual or if the SL-T11R is modified by the customer.
• When using the SL-T11R to protect machine operators against a hazard or hazardous zone or using the SL-T11R as a safety component for any purpose, always follow the applicable require­ments of the laws, rules, regulations and standards in the country or region where the SL-T11R is used. For such regulations, you should make direct contact with the regulatory agency responsi­ble for occupational safety and health in your country or region.
• Depending on the type of machine on which the SL-T11R is to be installed, there may be special safety regulations related to the use, installation, maintenance, and operation of the safety compo­nent, and such safety regulations must be fulfilled. The responsible personnel must install the SL-T11R in strict compliance with such safety regulations.
• The responsible personnel must do the training to the assigned personnel for the correct use, installation, maintenance, and operation of the SL-T11R. "Machine operators" refers to personnel who have received appropriate training from the responsible personnel and are qualified to oper­ate the machine correctly.
• Machine operators must have specialized training for the SL-T11R, and they must understand and fulfill the safety regulations in the country or region in which they are using the SL-T11R.
• When the SL-T11R fails to operate, machine operators must immediately stop the use of the machine and the SL-T11R and report this fact to the responsible personnel.
• The SL-T11R is designed with the assumption that it would be correctly installed in accordance with the installation procedures described in this instruction manual and correctly operated according to the instructions in this instruction manual. You must perform an appropriate installa­tion of the SL-T11R after conducting a sufficient risk assessment for the target machine.
• The SL-T11R should be processed as an industrial waste product when being disposed.
Precaution on Use
Operators
Danger
Failure to follow the instruction results in significant harm to the machine operators including serious injury or death.
Failure to follow the instruction may result in damage to the SL-V or to the machine on which it is installed.
Provides additional information for proper operation.
Provides advanced and useful information for operation.
• In order to operate the SL-T11R correctly, the responsible personnel and machine opera­tors must fulfill all of the procedures described in this instruction manual.
• No person other than the responsible personnel and machine operators should be allowed to install or test the SL-T11R.
• When performing electrical wiring, always fulfill the electrical standards and regulations for the country or region in which the SL-T11R is used.
Danger
• The SL-T11R is not designed to be explosion-proof. Never use it in the presence of flam­mable or explosive gases or elements.
• Do not use the SL-T11R in the presence of substances, such as heavy smoke, particulate matter, or corrosive chemical agents, that may induce deterioration in product quality.
• Be sure to confirm absolutely that there is nobody in the hazardous zone, before the inter­lock is released (i.e. the machine system restarts) by the interlock reset mechanism. Fail­ure to follow this warning may result in significant harm to the machine operators, including serious injury or death.
• Interlock reset mechanisms (such as switches) must be installed so that the whole hazard­ous zone can be checked by the responsible personnel. Interlock reset mechanisms should not be accessible from within the hazardous zone.
• Use the SL-T11R within the enclosure of IP54 or higher.
• Ensure the space around the unit for ventilation.
• Do not install the SL-T11R in the locations listed below:
• Locations with high humidity and a risk of condensation
• Locations where water will splash onto the SL-T11R
• Locations where there are corrosive gases
• Locations where any flammable gases or explosive gases exist
• Locations where the SL-T11R may be directly subjected to vibration or impact
• Locations where strong electromagnetic noises may affect the SL-T11R
Tar ge t ma ch in e
Danger
• The SL-T11R has not undergone the model certification examination in accordance with Article 44-2 of the Japanese Industrial Safety and Health Law. The SL-T11R, therefore, cannot be used in Japan as a “Safety Device for Press and Shearing machines” as estab­lished in Article 42 of that law.
• The machine on which the SL-T11R is to be installed must be susceptible to an emer­gency stop at all operating points during its operation cycle. Do not use the SL-T11R for machines with irregular stop times.
• Do not use the SL-T11R for power presses equipped with full-revolution clutches.
• The SL-T11R cannot be used as a PSDI because it does not fulfill the requirements of OSHA 1910.217(h). Refer to OSHA 1910.217 for the PSDI mode.
• Do not use the SL-T11R to control (stop forward motion, etc.) trains, cars and other trans­portation vehicles, aircraft, equipment for use in space, medical devices, or nuclear power generation systems.
Circuit design and wiring
Danger
• Always turn off the power to the SL-T11R when performing electrical wiring.
• You must fulfill the electrical standards and regulations in the country or region in which the SL-T11R is being used when you perform the electrical wiring.
• To avoid the risk of electric shock, do not connect any of the SL-T11R inputs/outputs except for FSD to DC power sources outside of the range of 24 V DC + 10% or to any AC power source.
• To avoid the risk of electric shock, be sure that the hazardous voltage is isolated from all wiring of the SL-T11R with reinforced insulation or double insulation except for FSD.
• In order to fulfill the requirements in IEC61496-1, UL61496-1, EN61496-1 and UL508, power supply for the SL-T11R must fulfill the conditions listed below.
A rated output voltage of 24 V DC (SELV, Overvoltage Category II) within + 10% and -20%.
(a) (b) Double insulation or reinforced insulation between the primary and secondary circuits. (c) Output holding time of 20 ms or more. (d) A power supply must fulfill the requirements of the electrical safety and
electromagnetic compatibility (EMC) regulations or standards in all countries and/or regions where the SL-T11R is used.
(e) A secondary circuit of power supply (output) must fulfill the requirements for Class 2
Circuits or Limited Voltage/Current Circuits specified in UL508, if the SL-T11R is used in the United States or Canada.
• Do not install the electric wiring of the SL-T11R together with or in parallel with high-volt­age electrical or power lines.
• Both of the two FSDs provided on the SL-T11R must be used to establish a safety-related machine control system. Establishing a safety-related machine control system with just one of the FSDs cannot stop the machine in the event of an FSD failure and may result in significant harm to the machine operators including serious injury or death.
• The Alert output, AUX output, Clear/Blocked Output, state information output and inter­lock-reset-ready output are not allowed to be used as safety outputs for safety-related machine control systems. Usage of these functions as safety outputs may result in signif­icant harm to the machine operators, including serious injury or death.
• The wait input is not allowed to be connected to the output from any components compris­ing a part of the safety-related machine control system. If the wait input is connected to the output of a safety component it may result in significant harm to the machine opera­tors, including serious injury or death.
• The transmitter and receiver cables of the SL-V connected to the SL-T11R must be within the lengths specified in this instruction manual. Usage of cables longer than the specified length may cause the improper operation of safety functions and may cause a dangerous situation.
Testing and Maintenance
• You must always perform the pre-check test in accordance with the pre-check test procedures, after maintenance, adjustment or alignment of the target machine or the SL-T11R and before the machine startup.
• If the SL-T11R does not operate properly when you perform pre-check test in accordance with the pre-check test procedures specified in this instruction manual, do not operate the machine.
• You must periodically examine the machine to verify that all brakes, other stop mechanisms, and control devices operate reliably and correctly in addition to checking the SL-T11R.
• The responsible personnel must perform maintenance procedures as specified in this instruction manual at least once every six months to ensure safety to the machine and SL-T11R.
• If the SL-V, which is connected to SL-T11R, goes to lockout condition with EDM error, the relay inside the SL-T11R may have a fault. In this case, replace the relay board according to "Replacing the relay board" of page 4.
1
SL-T11R-IM-E
Standards and Regulations
S

Cable Specification

1 The SL-T11R is a safety component as established by the EU Machinery Directive (2006/42/EC)
2 The SL-T11R complies with the following IEC Standards and has been certified by TÜV SÜD
3 The SL-T11R complies with the following UL (Underwriters Laboratories Inc.) and has been certi-
4 The SL-T11R also complies with the following EMI regulations in North America.
5
6 The SL-T11R has been designed in consideration of the following standards and regulations.

Checking the Package Contents

SL-T11R  u1 Instruction Manual (this document) u1

Cable

NOTE
n Unit connection cable.
n Junction cable
Pin No. Wire color Assigned function Pin No. Wire color Assigned function
Reference
Annex V. The SL-T11R complies with the following EU Directives and EN Standards and has been certified by TÜV SÜD Product Service GmbH.
EU Directives
• Machinery Directive (2006/42/EC)
• EMC Directive (2004/108/EC)
EN Standards
• EN61496-1 Type 4 ESPE
• EN55011 ClassA
• EN50178
Product Service GmbH.
• IEC61496-1 Type 4 ESPE
• ISO13849-1:2006 Category4, PL e
fied by UL. (CCN :NIPF/NIPF7)
• UL61496-1 Type 4 ESPE
• UL508
• FCC Part 15B Class A Digital Device
• ICES-003 Class A Digital Apparatus The SL-T11R has not obtained the model certification examination in accordance with Article 44-2
of the Japanese Industrial Safety and Health Law. Therefore, the SL-T11R cannot be used in Japan as a "Safety Devices for Presses and Shearing Machines" as established in Article 42 of that law.
For details regarding the following standards, contact the third-party certification organization, such as UL.
Corresponding standards
• EN60204-1
• EN692
• EN693
• OSHA 29 CFR 1910.212
• OSHA 29 CFR 1910.217
• ANSI B11.1 - B.11.19
• ANSI/RIA R15.06 - 1999
• SEMI S2
• "Guidelines for Comprehensive Safety Standards of Machinery", July 31, 2007, number 0731001 issued by Ministry of Health, Labor, and Welfare in Japan.
Be sure to use the following cables for the connection between the SL-V and the SL-T11R. The SL-T11R does not operate when combined with other SL-V cables.
Shape Model Length
φ
5.8
36.1
14.3
(Transmitter/receiver set)
45
M14 connector, male
SL-VPT3PM 3m
SL-VPT5PM 5m
φ
17
SL-VPT10PM 10 m
Shape Model Length
(Transmitter/receiver set)
φ
44
φ
17
M14 connector, female
5.8 45
M14 connector, male
SL-VCT10PM 10 m
φ
17
Transmitter Receiver
1PinkInterlock mode selection input 1WhiteOSSD 2
2Blue0 V 2Blue0V
3VioletWait in put 3BlackOSSD 1
4GreenInterlock-reset-ready output 4YellowRESET input
5 Orange
Orange/
6
Black
Communication cable 1 (RS485_+)
Communication cable 2 (RS485_-)
5Orange
6
Orange/
Black
Communication cable 1 (RS485_+)
Communication cable 2 (RS485_-)
7Brown+24 V 7Brown+24 V
8RedAUX (auxiliary) output 8RedEDM input
9GreyState infromation output 1 9Red/BlackOverride input
10 Grey/Black State infromat ion output 2 10
Ye l l o w /
Black
Muting lamp output
11 Pink/Black Alert output 11 Light blue Muting input 1
White/
12
Clear/Blocked Output 12
Black
Light blue/
Black
Muting input 2
M14 connector male pin assignment M14 connector female pin assignment
12
10
3
9
12
11
4
8
7
5
6
21
10
9
3
11
12
8
4
5
7
6
(1) Cable length
When using the unit connection cable and the junction cable together, the sum of the combined cable length must not be 30 m or less for the transmitter and receiver respectively.
Danger
(2) Minimum cable bending radius : 5 mm (10 mm for the part where the connector to the SL-T11R is
(3) Identification of connector cables
Cables can be identified by the colors of their connectors and their cable insulation.
1. Cable Insulation colors
2. Connector colors
NOTE
• Cables must be within the lengths specified. Failure to follow this specification may cause improper operation of safety function, and may cause dangerous situation.
attached)
2. Connector
1. Cable insulation
Cables for Transmitter : Cable insulation in grey Cables for Receiver : Cable insulation in black
Black connectors
Be sure to connect the unit connection cable for receiver to the SL-V receiver and the unit connection cable for transmitter to the SL-V transmitter.

Part Names

SL-V Series connector,
"T" side
L-V Series connector,
"R" side
Mode switch
cover fastener
Indicators
Front view Front view
POWER
FSD-ON
FSD-OFF
INTERLOCK
MUTE1
10 11 12 13 14 15 16 17 18 19 20 21
See Instruction Manual.
Hole for mounting screw (for M4)
T R T R
Mode switches
terminal block
MODE SWITCH 1
MANUAL RESET
2
AUTO RESET 3 not use 4 not use 5 not use 6 not use 7 not use 8 not use
POWER
FSD-ON
FSD-OFF
INTERLOCK
MUTE1
10 11 12 13 14 15 16 17 18 19 20 21
See Instruction Manual.
RESET
WAIT
EDM
O-RIDE
MUTE2
1
2
3
4
5
6
7
8
9
CAUTION
Electric shock
Relay circuit board replacement screw
Signal input/ou tput
Hole for mounting screw (for M4)
RESET
WAIT
EDM
O-RIDE
MUTE2
1
2
3
4
5
6
7
8
9
CAUTION
Electric shock
Ter m i n a l replacement screws
Relay output terminal block
Side Rear
DIN rail mating area
Din rail lock pin
SL-U2 connector *Covered by tape at time of shipment.
SL-U2, mounting holes
Bottom
Connector for the light interference prevention connection *Covered by tape at time of shipment.
Output connector A
A-1 A-2 A-3 B-1 B-2 B-3
Output connector B
SL-T11R-IM-E
2
Loading...
+ 4 hidden pages