Keyence IB, IG Series, I- SERIES Series Manual

NEW LINEUP
I
-
SERIES
Intelligent Sensor
Make Sensing Easy:
FROM SIMPLE DIFFERENTIATION TO HIGH SPEED,
IB S eries
IG S eries
NEW
NEW
Multi-Purpose CCD Laser Micrometer
IG Series
Thrubeam Type Laser Detection Sensor
IB Series
Low-cost High Performance
2
Detection of presence/absence
Low cost
Thrubeam Type Laser Detection Sensor IB Series
Light volume differentiated with high-accuracy
Light-receiving element PD
Through high-accuracy differentiation of the volume of light received, the photoelectric sensor allows a multitude of previously impossible applications to be achieved.
A PD (Photo Diode) is used within the light-receiving element. Even very small changes in received light intensity are sensed, making this sensor incredibly versatile.
High-Accuracy Differentiation Made Easy without being Influenced by the Target
Detecting cap tightness Differentiation of different films Determining chip gradient Liquid turbidity
Main applications
CHOOSE KEYENCE FOR ALL THRUBEAM TYPES
Photoelectric sensor
IB S eries
3
High-accuracy measurements
High end
Multi-Purpose CCD Laser Micrometer IG Series
High-accuracy differentiation using edge position
Light-receiving element CCD
Achieving high-accuracy differentiation without being influenced by the total light volume
A CCD (Charge Coupled Device) is used in the light-receiving element. High-accuracy differentiation is achieved by capturing the edge of the thrubeam laser light rather than the volume of received light.
Transparent glass
edge detection
Outer diameter
high-accuracy differentiation
Sheet edge control Roller gap measurement
Main applications
Thrubeam measuring instruments
SERIES
Intelligent
To ug h
Easy
I
I
-
SERIES
Intelligent Sensor
IG Series
4
Supports everything from simple differentiation to high-accuracy detection
Industrial application examples
IB
Within the various manufacturing processes of liquid crystal, the presence or absence of a glass plate is detected during transportation. As the light volume can be differentiated with high-accuracy, stable detection is possible.
This device definitively detects the chip gradient and/or the presence of a chip on even minute targets during the mounting process. Fur thermore, as the sampling occurs at 80 µs, detections on high-speed lines are also possible.
By sensing two locations simultaneously, the device detects the orientation of the paper feed and/or the skew angle during transportation. Continuous measurement is possible with the small type head and high-speed sampling.
Detects differences in various shafts within metal workings or during the assembly process. By using the included Hold function, this can be determined without stopping the target.
By sensing the thrubeam volume of laser light, the device definitively captures any differences in the transparent film. Fur thermore, by aligning multiple devices along the width, continuous detection of uneven coating over multiple points is possible.
By sensing the thrubeam volume of laser light through glass, the turbidity of factory waste water can be determined. Furthermore, judgment values can be set between 0 and 100%.
Detects the diameter and cap tightness when adding the caps onto the bottles. Due to high-speed sampling, detection can be conducted on the conveyer without stopping the target.
By sensing thrubeam volumes of the laser light, the liquid level can be detected with high accuracy. Furthermore, by using a compact head the device can be positioned in even the narrowest of spaces.
IB Series Applications
Liquid Crystal Industry
Detection of presence/absence of liquid crystal glass
IB
Electronic Industry
Detection of chip components
IB
Metal Industry
Differentiation of different metal shafts
IB
Electric Industry
Printer paper feed orientation detection
IB
Plastics Industry
Differentiation of different films
IB
Food and Pharmaceutical Industry
Bottle-neck diameter judgments and detection of cap tightness
IB
Food and Pharmaceutical Industry
Detecting the liquid level of test tubes
IB
Factories
Turbidity detection of factory waste water
IB
5
Detect s the notch position of a wafer with high ac curacy. The device exhibits a repeat accuracy of 5 μm and the differen tial ability that is top of its cl ass.
Conduc ts high-accuracy trans port position determination of liquid crystal glass. Inc orporating a new algorithm, stable detection of even transparent materials is pos sible.
Conduc ts edge control duri ng the winding proces s of electrode sheets, achieving uniform rolling.
Differentiates the coating line diamete r immediat ely after extrusion. By calcul ating the roundness d ifferentiati on between X-Y, this can be conduc ted simulta neously without exter nal softwar e.
Differentiates the positioning of the t arget during pressin g. The device is IP-67 rated, with the ability to withs tand use i n unfavorable env ironments over a l ong period of time.
Measur es the internal diameter or ga ps of pressed parts. By using the various Hold func tions you can also mea sure the m aximum inte rnal diamet er.
Conduc ts the edge control o f film dur ing windin g processes, and achieves a uniform roll. The level o f shielded light can be changed at will, allowing for the hi gh-accuracy determin ation of thin film.
Monito rs the gap of thin pl ate cold rolling. Mounting in narr ow spaces i s also p ossible thanks to a co mpact head.
X
Y
IG Series Applications
Semi-conductor Industry
Wafer notch detection
IG
Electrical Industry
Edge control of a lithium­ion electrode sheet
IG
Metal Industry
Target placement confirmation
IG
Plastics Industry
Edge control of a transparent sheet
IG
Electric Cable Industry
Exter nal diameter differentiation during coating extrusion processes
IG
Metal Industry
Inter nal diameter differentiation of punch press materials
IG
Iron and Steel Industry
Roll gap measurement
IG
Liquid Crystal Industry
Position determination of liquid crystal glass
IG
IG Series
6
Wide Variety of Application Modes
Achieving the Best Stability Multi-Purpose CCD Laser Micrometer
Reflecting mirror
Parallel light lens
Multi-wavelength laser
28mm type
IG- 028
10mm type
IG- 010
28 mm
10 mm
Edge Control Mode
The distance from the end of the measurement range to the edge of a target is measured.
Outer Diameter Measurement Mode
The outer diameter or width of a target is measured.
IG Series
Repeatability of 5 μm
Linearity of ± 0.1% (IG-028)
New function: Position Monitor