Keyence GV-H45, GV-H130, GV-H1000, GV-H450, GV-H45L Instruction Manual

...
1
GV-IM-E
Digital CMOS Laser Sensor
GV Series
Instruction Manual
Read this manual before using the software in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time.
The displayed values indicate guidelines for distances and should not be used in the actual applications for measurement.
*The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
Safety measures for the laser
Laser radiation emission indicator
The laser radiation emission indicator lights up after turning on the power and while the laser beam is being emitted.
Laser emission stop input
The laser emission stops when an emission stop (purple line) signal is input (for 20 ms or longer). The emission stops while the signal is input. The laser beam is emitted a maximum of 20 ms after the signal input is canceled. The control output functions according to the detection value even while laser emission stop is input.
Laser warning labels
The following diagrams show the type and position of laser warning labels according to the GV Series.
The IEC warning/explanatory labels are only included with Class 2 laser products. When using this product in the countries and/or regions other than U.S., use the IEC warning/explanatory label in the package of this product. In this case, it can be affixed on the FDA (CDRH) warning label, which has already been affixed to this product.
Check if the parts and equipment listed below are included in the package of the model you purchased before using the unit.
Sensor amplifier
Sensor head
We have thoroughly inspected the package contents before shipment. However, in the event of defective, broken or missing items, please contact your nearest KEYENCE office.
Safety Precautions
WARNING
!
The GV Series is intended for the detection of target objects. Do not apply the product to safety circuits for human protection.
!
This product is not of explosion-proof construction. Do not use it in a location where any flammable gases, liquid, or powder exist.
Safety Precautions on Laser Products
WARNING
!
This product employs a semiconductor laser for its light source.
!
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
!
Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result.
!
Do not disassemble this product. Laser emission from this product is not automatically stopped when it is disassembled.
Precautions on class /2 laser products
! Do not stare into the beam. ! Do not direct the beam at other people or into areas
where other people unconnected with the laser work might be present.
! Be careful of the path of the laser beam.
If there is a danger that the operator may be exposed to the laser beam reflected by specular or diffuse reflection, block the beam by installing an enclosure with the appropriate reflectance.
! Install the products so that the path of the laser beam is
not as the same height as that of human eye.
Precaution on class 1 laser products
! Do not stare into the beam.
Item
Description
Model
GV-H45, GV-H130,
GV-H450, GV-H1000
GV-H45L, GV-H130L,
GV-H450L, GV-H1000L Wavelength 655nm
FDA (CDRH) Part 1040.10
Laser Class
Class Laser Product
Class 1 Laser Product*
Output 560µW 220µW
IEC 60825-1
Laser Class Class 2 Laser Product Class 1 Laser Product Output 560µW 220µW
Note
OUT
LASER
1
2
CLP
OUT
LASER
TIM
BANK
SET
SEL
MODE
1 2
1
2
1 spotDATUM
series
Laser radiation emission indicator
Sensor amplifier Sensor head
Checking the Package Contents
GV-H45(L)/GV-H130(L) GV-H450(L)/GV-H1000(L)
Aperture label
Aperture label
Laser transmitter
FDA (CDRH) warning label (Class )*
Aperture label
Aperture label
Laser transmitter
FDA (CDRH) warning label (Class )*
* Not included with GV-H45L/H130L/H450L/H1000L.
z Aperture label
z IEC warning/explanatory label (CLASS 2)
z FDA (CDRH) warning label (CLASS )
The FDA (CDRH) warning labels are only affixed to Class laser products.
MODE
SEL
SET
LASER
1
2
OUT
1 2
TIM
1spot
CLP
BANK
DATUM
MODE
SEL
SET
LASER
1
2
OUT
1 2
TIM
1spot
CLP
BANK
DATUM
series
series
GV-21/GV-21P (main unit)
GV-22/GV-22P (expansion unit)
Amplifier x1 Instruction manual x1
Amplifier x1
GV-H45(L)/H130(L)
GV-H450(L)/H1000(L)
Sensor head x1 Insulating sheet x1 Mounting bracket x1 Board nut x1 M3 x L30 screw x2 Laser warning sticker* x1
Sensor head x1 Insulating sheet X1 Mounting bracket x1 Board nut x1 M4 x L35 screw x2 Laser warning sticker* x1
* This is not included with GV-H45L/H130L/H450L/H1000L.
96M11664
2
GV-IM-E
Mounting the sensor amplifier
Mounting the GV-21/GV-21P (main unit)
1 Align the claw at the bottom of the
main body with the DIN rail. While pushing the main body in the direction of the arrow 1, slant it in the direction of the arrow 2.
2 To dismount the sensor, raise the
main body in the direction of the arrow 3 while pushing the main body in the direction of the arrow 1.
When using the amplifier mounting bracket (OP-76877) (sold separately), mount it as shown in the diagram to the right.
Mounting the GV-22/GV-22P (expansion unit)
Several expansion units can be used in connection with the main unit. Up to three expansion units can be connected to one main unit.
Expansion units with different output types (such as a PNP output main unit to an NPN output expansion unit) cannot be connected together.
1 Remove the expansion
protective cover from the GV-21/GV-21P (main unit)
2 Install the amplifiers (expansion units) on the DIN rail.
For more information about mounting, see "Mounting the GV-21/GV-21P (main unit)".
3 Push the expansion unit into
the main unit connector until a clicking sound can be heard.
4
Install the end units (OP-26751: 2 units in a set) (sold separately) on either side of the amplifiers (main or expansion units). Secure the end units in place with screws on top (2 on each end unit).
The end units are mounted in the same way as the amplifiers.
Amplifier wiring
The following information shows the I/O cable. For more information about the I/O circuit, see page 9 of this Instruction Manual.
*1
GV-22/GV-22P (expansion unit) do not have brown or blue lines. Power is supplied to the expansion units through GV-21/GV­21P (main unit).
*2 The external input switches as shown
below depending on the amplifier OPTIONAL settings.
! oFF. ........Inp ut off
! SFt.......... External shi ft
! bnK.... .....Ba nk switching
! tim........... Timing input
Sensor head part names
Connecting the sensor head
1 Unlock the sensor head
connector and insert it into back of the amplifier.
2
Turn the round part of the connector clockwise until a clicking sound is heard to lock it.
When shortening the sensor head cable, follow the instructions given in the "Sensor Head Connector Assembly Manual" included with the sensor head.
Mounting the sensor head
Use the dedicated mounting bracket to mount the sensor head. When not using the dedicated mounting bracket, the included insulating sheet must be inserted between the mounting surface and the sensor head as shown in the diagram. (When using the dedicated mounting bracket, the insulating sheet is not necessary.)
Mounting and Wiring the Sensor Amplifier
CAUTION
!
When connecting multiple amplifiers (expansion units), first check to make sure that the power is turned off to all of the main and expansion units. Connecting the units with the power turned on may cause damage to the units.
!
Push the amplifiers (expansion units) as far as possible into the main unit. If they are connected at a slant or not inserted securely, the units may be damaged.
!
Only GV Series amplifier can be connected (DL Series cannot be connected). Connecting other amplifiers may cause damage to the units.
(1)
(3)
(2)
Amplifier mounting bracket
Note
GV-21/ GV-21P
Expansion protective cover
Main unit
Expansion unit
Connector
End unit
End unit
Control output 1
Brown
*1
Blue
*1
Black
White
Pink
*2
Purple
Control output 2
External input
Laser emission stop input
10-30 V DC
Connecting and Mounting the Sensor Head
Laser receiver Mounting area
LASER
(Laser radiation
emission indicator)
OUT
(Control output
indicator)
Mounting area
1spot
(Spot reflection
indicator)
Laser
Connector
Connector
Unlocked
Locked
Note
z Mounting when detecting
targets close to a wall
z Mounting when detecting
targets in a hole
Receives little effect from stray laser light.
Variations in the detection value with effects from stray laser light.
The target cannot be detected when the transmitter or receiver are blocked.
Sensor head
Insulating sheet
Hexagon socket bolt (Accessory)
z When detecting uneven workpieces
! Stable detection
even on uneven areas.
! Incorrect values
can be detected on the uneven areas.
3
GV-IM-E
Sensor amplifier part names
*1 The reference surface (DATUM) detection indicator lights up when performing
reference surface detection. For more information, see "Reference surface detection (DATUM) method (Application)" on page 5 of this Instruction Manual.
*2
The spot reflection indicator lights up during normal detection and turns off during multiple reflection (when multiple peaks of received light intensity occurs due to diffuse reflection), insufficient light intensity, and when the target is out of the detection range.
*3 For more information about the CLP (clamp) function indicator, see "4. Clamp
function setting" on page 8 of this Instruction Manual.
*4 For more information about the timing input indicator, see "8. External input
setting" on page 8 of this Instruction Manual.
Main screen
The main screen can be switched between "Current/setting value display" and "Peak/ bottom value display". The main screen can be switched even during keylock.
Pressing the [Up] and [Down] arrow buttons simultaneously on the main screen forces the current value (red) to 0*. * With the default settings. For details, see "9. Shift target value setting" on page 9 of
this Instruction Manual.
When the channel No. 1 indicator is lit, the control output 1 (black line) setting value is displayed. When the channel No. 2 indicator is lit, the control output 2 (white line) setting value is displayed. Operations are different in F-2 mode. (See page 5 of this Instruction Manual.)
z Current value and display resolution
In the default state, the current value shows 0 when the workpiece is located at the maximum detection distance. Bringing the workpiece closer to the sensor head gradually increases the value and displays it up to the minimum detection distance.
The displayed values indicate guidelines for distances and should not be used in the actual applications for measurement.
When using sensor head GV-H130
For example, when using the defaults with the setting value (green) at 500, the comparator output turns on when the current value is 500 or greater and turns off when it is less than 500. If multiple reflection (when multiple peaks of received light intensity occurs due to diffuse reflection) occurs during F-1, F-2, or A-1 modes, the value immediately before the current value is held.
z Setting value
The following table shows the default setting values for each channel.
z Peak/bottom values
Peak value
: Resets when the detection value exceeds the setting value
and holds the maximum value (peak value) until the detection value falls below the setting value again.
Bottom value
: Resets when the detection value falls below the setting value
and holds the minimum value (bottom value) until the detection value exceeds the setting value again.
The held peak and bottom values can be cleared by pressing and
hold the [Up] arrow button.
Sensor Amplifier
Item
Current value
GV-H45 (L) GV-H130 (L) GV-H450 (L)
GV-H1000 (L)
Detecting range (mm)
20.0 to 45.0
55.0 to 130.0
160 to 450 200 to 1000 Digital display (initial) 250 to 0 750 to 0 290 to 0 800 to 0 Display resolution 1 2 1 5
CLP
OUT
LASER
TIM
BANK
SET
SEL
MODE
1 2
1
2
1 spotDATUM
series
Reference surface (DATUM) detection indicator
*1
(red)
Current value display (red)
Setting value display
(green)
Spot reflection (1spot) indicator*2
(green)
Arrow buttons
Output status indicator
(red)
Laser radiation emission indicator (green)
[SET] button
Channel No. indicator (green)
LED bar
CLP function indicator*3 (red)
[MODE] button
Bank input indicator (green)
Timing input indicator*4 (red)
DATUM
DATUM
DATUM
Setting value/current value display
Setting value (green)
Peak value (green) Bottom value (red)
Channel No. indicators
Current value (red)
Pressing the [MODE] button switches the channels (channel No. indicators).
Peak value/bottom value display
Pressing the [UP] arrow button resets the peak and bottom values.
Alternate
1 2
1 2
1 2
or
SET
MODE
SET
MODE
SET
MODE
Note
Note
Operation
mode
Item
Default value
GV-H45 (L) GV-H130 (L) GV-H450 (L) GV-H1000 (L)
F-1, A-1, A-2
Control output
1 (black)
(Channel 1 lit)
150 500 200 500
Control output
2 (white)
(Channel 2 lit)
125 400 150 400
F-2
Control output 1 (black) HIGH (Channel 1 lit)
150 500 200 500
Control output 1 (black) LOW (Channel 2 lit)
100 300 100 300
Control output 2 (white) HIGH (Channel 1
flashing
)
125 400 150 400
Control output 2 (white) LOW (Channel 2 flashing)
75 200 50 200
Example
750
0
0mm
55mm
130mm
Current value
Distance
Minimum detection distance
Maximum detection distance
Reference
4
GV-IM-E
Detection method
The GV Series has two type of detection methods: "Distance detection method" and "Reference surface (DATUM) detection method". The reference surface (DATUM) detection method can only be used when performing reference surface calibration.
Control output 2 is fixed to distance detection method for all operation modes.
Distance detection method (Normal)
Detects the distance between the detection target and the sensor head, and then performs control output. The following table shows each operation mode and the auto calibration that can be used.
z Area detection mode (F-2 mode)
Operation image
When using the F-2 mode, the channel No. indicator switches in the following order each time the [MODE] button is pressed.
Configure the sensitivity setting in F-1 mode (with the default settings).
2-point calibration
The setting is automatically calculated as the mean value detected from two points: with the workpiece and without the workpiece.
1 Press the [SET] button once
without a workpiece in place.
The current value without the workpiece is read.
2 Place a workpiece in the
detection position, and quickly press the [SET] button once again.
This concludes 2-point calibration and the sensor returns to the detection state.
If there is very little difference between the values obtained in
Step 1 and Step 2, then "---" flashes in the setting value display area after calibration is complete. The setting value is still updated.
Fine-tune setting value
Use the [Up] and [Down] arrow buttons to fine-tune the setting value.
Reference surface (DATUM) calibration
Use DATUM calibration when comparator output cannot be performed correctly during 2-point calibration (due to problems such as chattering from the surface of the workpiece).
3 Press the [SET] button once without a workpiece in place
(reference surface).
4 Using the same conditions,
Item Setting range
Setting
value fine-
tuning
-199 to 999
Reference
DATUM
SET
MODE
1 2
Increases the setting value
Decreases the setting value
Using Basic Operations
Configuring the Sensitivity Setting and Operation Mode
Operation mode Description
Usable
auto calibration
General F-1
Normal detection mode
The most general mode. ON/OFF judgment is performed based on one setting value.
2-point calibration Full auto calibration Maximum sensitivity setting
Special
F-2
Area detection mode
On/OFF judgment is performed on an area based on two settings.
2-point area calibration 1-point area calibration
A-1
Edge hold mode
Detects the change in distance (derivation) to the target and holds the display.
2-point calibration Full auto calibration Maximum sensitivity setting
A-2
Surface detection mode
When multiple beams of light are reflected from the detection target, the closest reflected light is judged as the detection value.
2-point calibration Full auto calibration Maximum sensitivity setting
Note
OFF
OFF
ON
LOW setting value
HIGH setting value
Only this will turn ON.
1 2
1 2
1 2
1 2
MODE
Press once.
MODE
Press once.
MODE
Press once.
MODE
Press once.
Control output 1 (black) HIGH setting value ! Channel No. 1
indicator lights up
Control output 1 (black) LOW setting value ! Channel No. 2
indicator lights up
Control output 2 (white) HIGH setting value ! Channel No. 1
indicator flashes
Control output 2 (white) LOW setting value ! Channel No. 2
indicator flashes