Friedrich MR36TQY3JM User Manual

5 (1)
Friedrich MR36TQY3JM User Manual

Multi Zone Air Conditioner

SVC MANUAL(Exploded View)

CAUTION

Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

MODEL : MR36TQY3JM

960-920-04

1. Specification

Outdoor Unit

 

 

 

 

 

 

Outdoor Unit

 

MR36TQY3JM

 

 

 

 

 

Capacity(*)

 

 

Btu/h Class

34,000

Power Input

Cooling

 

kW

0.77~2.72~ 3.92

(Min.~Rated~ Max.)

Heating

 

kW

1.12~3.58~4.1

Running Current

Cooling

 

A

3.3~11.8~17.0

 

Heating

 

A

4.9~15.5~17.8

Starting Current

Cooling/Heating

 

A

-

Power Supply

 

 

Ø / V / Hz

1/208 - 230/60

Power Supply Cable (Outdoor)

 

No.x AWG

3 × 12

Transmission Cable (Outdoor to Indoor unit )

 

No.x AWG

4 x 18 (Including Earth)

Dimensions

W x H x D

 

mm(inch)

900 x 1,165 x 370

 

(35 7/16 x 45 7/8 x 14 9/16)

 

 

 

 

Net Weight

 

 

kg(lbs)

95(209.4)

Max. Number of Connectable Indoor Units

 

4

Compressor

Type

 

Twin-Rotary

 

Qty x Model

 

GPT425DBA

 

Motor type

 

BLDC

 

Oil charge volume

 

cc

1300

 

Oil Type

 

FVC68D

Refrigerant

Cycle A Charge (at 7.5m)

 

g(oz)

3,500(123.46)

 

Cycle B Charge (at 7.5m)

 

g(oz)

-

 

Type

 

R410A

 

Control

 

EEV

Heat Exchanger

(Rows x Column x FPI) x No.

 

(2R x 26C x 17) x 2

 

Coil tube dia.

 

mm(inch)

7(0.276)

 

Defrosting Method

 

Reversing cycle

Fan motor

Capacitor

 

μF/Vac

-

 

Drive

 

Direct (DC)

 

Discharge Direction(Side/Top)

Side

 

Air Flow Rate x No. of Fan

 

CMM(CFM)

60(2,118) x 2EA

Sound Level(H)

Sound Pressure

 

dB(A)+3

57

Piping Connections

Liquid(Cycle A)

 

mm(inch)

6.35(1/4) × 4EA

 

Gas(Cycle A)

 

mm(inch)

9.52(3/8) × 4EA

 

Liquid(Cycle B)

 

mm(inch)

-

 

Gas(Cycle B)

 

mm(inch)

-

Piping length spec.

Max. total piping

 

m(ft.)

75(246.1)

 

Max. OD~ID piping

 

m(ft.)

25(82.0)

 

Piping length(no add'l refrigerant)

 

m(ft.)

30(123.0)

Max. Elevation

Outdoor Unit~Indoor Unit

 

m(ft.)

15(49.2)

Difference

Indoor Unit~Indoor Unit

 

m(ft.)

7.5(24.6)

Operation Range

Cooling

 

°C(°F)

-10 ~ 46 (14~114.8)

(Outdoor)

Heating

 

°C(°F)

-15 ~ 24 (5~75.2)

Note:

1.Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27C(80.6F) DB/19C(66.2F) WB

-Outdoor Temperature 35C(95F) DB/24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB/15C(59F) WB

-Outdoor Temperature 7C(44.6F) DB/6C(42.8F) WB

Piping Length - Interconnecting Piping Length 7.5m

-Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.The specification may be subject to change without prior notice for purpose of improvement.

Conversion Formula

kW = Btu/h x 0.0002931 cfm = CMM x 35.3

- 2 -

2. Function Table

Category

Function

A4UW363FA2 [MR36TQY3JM]

 

 

 

 

Defrost / Deicing

O

 

High Pressure Switch

X

 

Low Pressure Switch

X

Reliability

Phase protection

X

Restart Delay (3-minutes)

O

 

 

Self Diagnosis

O

 

Soft Start

O

 

Test Function

X

Convenience

Auto operation(Artificial intelligence)

O

Auto Restart Operation

O

 

CAC Network

Central control(LGAP)

X

PDI(Power Distribution Indicator)

X

Function

PI485

X

 

Special function kit

Low ambient operation

O

Others

Thermistor

-

Note :

O: Applied, • X: Not applied, • - : No relation,

Option: Model name & price are different according to options, and assembled in factory with main unit.

Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.

- 3 -