Eppendorf Micro Test Tubes User Manual

Eppendorf Micro Test Tubes /
Eppendorf Reaktionsgefäße
Instruction Manual · Bedienungsanleitung
Eppendorf Micro Test Tubes

Principle of operation

Safety information

Reagents can cause corrosive burns and other health hazards. Samples can be infective or
contain other health hazards. When using toxic, aggressive or radioactive liquids or patho­logical bacteria, the appropriate national regulations should be observed. Reagents, test
Eppendorf Micro Test Tubes
tubes contaminated with reagent, and materials used for cleaning or disinfecting must be disposed of in accordance with laboratory regulations.
When transporting and/or storing outside of the laboratory, suitable safety precautions must
be made to prevent the material in the container from escaping.
Protect test tubes from falling over: Keep in a tube-rack or test tube holder.
Close the test tube lids before centrifuging. Open lids can be ripped off during centrifuging
and damage the centrifuge. When using centrifuges, only use the recommended accesso­ries and observe the operating instructions for the device and the maximum allowable centrifugation capacity.
When using the tubes with devices, only use the recommended accessories and observe
the operating instructions for the device.
In exceptional cases (e.g. high reagent vapor pressure) the test tube lids may open at higher
temperatures, particularly if the lid has not be properly closed or if the leakage seal has been damaged.
Please observe the maximum fill volume. When opening the tube, liquid in the lid may
escape.
The micro test tubes may not be used with liquid nitrogen, as the usage temperature range
extends only from -80 °C to +100 °C (see page 3 of "Technical Data"). In addition, the tube lid may spring open during thawing and propel the contents out of the tube when the tubes have previously been frozen in liquid nitrogen. The tube lids may not be submerged into the liquid phase. No liquid nitrogen may penetrate into the tubes.
Only use optically perfect and undamaged test tubes. When closing the tube, do not
damage the leakage seal.
®
When using Eppendorf Biopur
contamination after opening the blister pack, and use the test tube immediately. Please do not use test tubes from damaged blister packs.
After opening the bag of PCR clean micro test tubes, please use suitable measures to
prevent contamination.
micro test tubes, apply suitable measures to prevent
2
Eppendorf Micro Test Tubes

Operation

To fill the test tube, please bend back the lid and then close the tube.

Technical data

Safe-Lock micro test tubes: Test tubes with a guaranteed hinged lid clip for additional
Micro Test Tubes 3810X: Standard tubes fulfill high requirements for centrifugal stress and
®
Eppendorf Biopur
: Individually blister-packed Safe-Lock micro test tubes,
Eppendorf PCR clean: Safe-Lock micro test tubes, free of RNase, DNase, human DNA
Material: Polypropylene, autoclavable (121 °C, 20 min) when opened.
Resistance to chemicals: See Application No. 56: The best material for Eppis!
Centrifugability: Tubes can be centrifuged in a 45°-fixed-angle rotor at 40 °C
Storage: Keep out of sun- and UV light; store in a dry place at room
®
Shelf-life Biopur
: Minimum expiry date: Refer to the label on the box.
Application temperature: – 80 °C bis + 100 °C, autoclavable at 121 °C
Technical specifications are subject to change and errors!
protection against undesired opening during temperature control processes.
temperature- and chemical stability. They are easy to open and close.
sterile, free of pyrogen, RNase, DNA and ATP.
and PCR inhibitors.
In case of doubt please contact Eppendorf Application Support.
(sample temperature) for 90 min with aqueous saline solution (density 1.0 g/ml) up to the following RCF:
Tube Volume Standard Biopur Safe-Lock micro test tubes 0.5 ml 30,000 x g 22,000 x g Safe-Lock micro test tubes 1.5 ml 30,000 x g 22,000 x g Safe-Lock micro test tubes 2.0 ml 25,000 x g 22,000 x g Micro test tubes 3810X 1.5 ml 30,000 x g
With the use of an air-cooled centrifuge the sample temperature can exceed 40 °C. The centrifugation stability depends on the temperature. The mechanical resilience of the tubes is reduced by the use of organic solvents. In case of doubt and for LoBind Tubes please contact Eppendorf Application Support.
temperature.
Eppendorf Micro Test Tubes
3
Eppendorf Micro Test Tubes

Ordering information

Article Order no.
Safe-Lock micro test tubes
colorless
Color assortment in yellow, red, blue, green, colorless yellow red blue green amber (light-protected)
Eppendorf Micro Test Tubes
®
Biopur
colorless, individually packed
Safe-Lock micro test tubes PCR clean
colorless
Micro test tubes 3810X
colorless also available as colored tubes
Micro test tubes 3810X PCR clean colorless
Protein LoBind Tubes
colorless, PCR clean
DNA LoBind Tubes
colorless, PCR clean
Safe-Lock micro test tubes
0.5 ml
500 pcs. 0030 121.023
0030 121.708 0030 121.112 0030 121.120 0030 121.139 0030 121.147 0030 121.155
50 pcs. 0030 121.570
500 pcs. 0030 123.301
100 pcs. 0030 108.094
250 pcs. 0030 108.035
Order no.
1.5 ml
1000 pcs. 0030 120.086
0030 121.694 0030 120.159 0030 120.167 0030 120.175 0030 120.183 0030 120.191
100 pcs. 0030 121.589
1000 pcs. 0030 123.328
1000 pcs. 0030 125.150
1000 pcs. 0030 125.215
100 pcs. 0030 108.116
250 pcs. 0030 108.051
Order no.
2.0 ml
1000 pcs. 0030 120.094
0030 121.686 0030 120.205 0030 120.213 0030 120.221 0030 120.230 0030 120.248
100 pcs. 0030 121.597
1000 pcs. 0030 123.344
100 pcs. 0030 108.132
250 pcs. 0030 108.078
4
In touch with life
Your local distributor: www.eppendorf.com/worldwide
Eppendorf AG · 22331 Hamburg · Germany · Tel. +49 40 538 01-0 · Fax +49 40 538 01-556
E-Mail: eppendorf@eppendorf.com
Eppendorf North America, Inc. · One Cantiague Road · P.O. Box 1019 · Westbury, N.Y. 11590-0207 · USA
Tel. +1 516 334 7500 · Toll free phone 800 645 3050 · Fax +1 516 334 7506 · E-Mail: info@eppendorf.com
Application Support
Europe, International: Tel. +49 1803 666 789 · E-Mail: support@eppendorf.com
North America: Tel. 800 645 3050 ext. 2258 · E-Mail: support_NA@eppendorf.com
Asia, Pacific: Tel. +603 8023 2769 · E-Mail: support_AsiaPacific@eppendorf.com
eppendorf is a registered trademark.
B 0012 557.019-03/1207 · Printed in Germany