The company reserves the right to change information in this document without notice. Updates to
information in this document reflect our commitment to continuing product development and
improvement.
®
Eppendorf
and the Eppendorf logo are registered trademarks of Eppendorf AG, Germany.
New Brunswick™ and the New Brunswick™ logo are trademarks of Eppendorf AG, Germany.
®
Excella
is a registered trademark of Eppendorf, Inc., USA.
Carefully read this operating manual before using the device for the first time.
Also observe the operating manual enclosed with the accessories.
The operating manual should be considered as part of the product and stored in a location that is easily
accessible.
When passing the device on to third parties, be sure to include this operating manual.
If this manual is lost, please request another one. The latest version can be found on our website
www.eppendorf.com (international) or www.eppendorfna.com (North America).
1.2Danger symbols and danger levels
1.2.1Hazard icons
5
Electric shockCrushing
Material damageHazard point
Heavy loadsExplosion
1.2.2Degrees of danger
The following danger levels are used in safety messages throughout this manual.
DANGERWill lead to severe injuries or death.
WARNINGMay lead to severe injuries or death.
CAUTIONMay lead to light to moderate injuries.
NOTICEMay lead to material damage.
Operating instructions
New Brunswick Excella® E-1 Open Air Shaker
6
English (EN)
1.3Symbols used
ExampleMeaning
You are requested to perform an action.
1.
2.
• List.
Perform these actions in the sequence described.
References useful information.
2Safety
2.1User profile
CAUTION!
This equipment must be operated as described in this manual. If operational guidelines are
not followed, equipment damage and personal injury can occur. Please read the entire
Operating Manual before attempting to use this unit.
Do not use this equipment in a hazardous atmosphere or with hazardous materials for
which the equipment was not designed.
Eppendorf is not responsible for any damage to this equipment that may result from the
use of an accessory not manufactured by Eppendorf.
Safety
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
7
2.2Warnings for intended use
WARNING!
Never use the shaker to mix, stir, or shake a flammable liquid.
CAUTION! Heavy loads!
Only lift the device with another person or using a suitable aid. Be sure to use a transport
aid for transportation over long distances.
CAUTION!
A minimum load is required to safely operate the shaker.
Safety
New Brunswick Excella® E-1 Open Air Shaker
8
English (EN)
3Product description
3.1Main illustration
Abb. 3-1: Excella E-1 front and back view
Product description
New Brunswick Excella® E-1 Open Air Shaker
2
9
English (EN)
1
Fig. 3-1:Excella E-1 front and back view
1 Speed dial
2 Electrical specification plate
3 ON/OFF Switch
4 Fuse holder
5 Power connector
3
5
4
3.2Overview
The Excella E-1 is a portable benchtop shaker utilizing a UniCentric™ single eccentric counterbalanced
drive to provide horizontal plane rotary motion in a 1.91 cm (¾ in) circular orbit. The shaker is operated
continuously over a range of 50 rpm – 400 rpm .
A wide variety of platforms can be used with the E-1. Dedicated platforms are available for a variety of flask
sizes. Universal platforms, and test tube racks are also available.
10
Product description
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Installation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
4Installation
4.1Inspection and unpacking
Inspection of Boxes
After you receive your order from Eppendorf, inspect the boxes carefully for any damage that may have
occurred during shipping. Report any damage immediately to the carrier and to your local Eppendorf Sales
Order Department.
Packing List Verification
Verify against your packing list that you have received the correct materials.
Do not position the equipment so that it is difficult to unplug from the mains/power.
Physical Location
It is essential that the instrument be situated in a area where there is sufficient space for the shaker and
platform to clear walls and obstructions during operation.
The surface on which the E-1 is placed must be smooth, level, and able to support the shaker under full
load operating conditions.
Operating Environment
The shaker is designed to operate optimally in the following ambient conditions:
• 5 – 45 °C
• 20 – 80 % Relative Humidity non-condensing
• Up to 2000 m
12
Installation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
4.3Installing a platform
A platform must be installed on the shaker prior to use.
1. Loosen the four knobs on the SPILL COVER that is bolted to the bearing housing.
Abb. 4-1: Platform installation (top view)
1
2
3
Fig. 4-1:Platform installation (top view)
1 Knobs (4)
3 Speed dial
2 Spill cover
2. Aligning the four slots in the platform with the four holes in the SPILL COVER, place the platform on
the SPILL COVER.
3. Tighten the knobs to secure the platform.
4.4Install flask clamp
Flask clamps purchased for use with universal platforms require installation. All clamps are shipped
complete with hardware.
Installation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
NOTICE! Damage to shaker
Do not over fill flasks.
1. Clamps are installed by securing the base of the clamp to the platform with the correct type and number
of screws.
Eppendorf flask clamps are used on a variety of shaker platforms. Flat head screws of different lengths and
thread pitch are used to secure the clamp. To identify the proper screw for your shaker application by
reference to the head style, consult the following table, find the proper screws, and set the others aside.
DescriptionPart No.QuantityApplication
S2116-305115/16 in (7.9 mm) thick
aluminum, phenolic and
10 – 24 × 5/16 in (7.9 mm)
flat Phillips head screw
stainless steel platforms.
13
The previous table also applies to 2800 ml Fernbach Flask Clamps.
4.5Electrical connections
CAUTION!
A detachable main power cord has been provided with your unit. Only use the cord
provided and do not replace cord with an inadequately rated cord.
CAUTION!
Make sure the speed dial is set to 0 % before turning on the power.
Before making electrical connections, verify that the power source voltage matches the voltage on the
ELECTRICAL SPECIFICATION PLATE and that the ON/OFF SWITCH is on the OFF position. The
ELECTRICAL SPECIFICATION PLATE and the ON/OFF SWITCH are located on the rear panel (see
Fig. 3-1 on p. 9).
Connect the MAINS/POWER CORD to the MAINS/POWER CONNECTOR on the rear panel and the other
end to a suitable, grounded receptacle.
14
Installation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Operation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
5Operation
5.1Starting the E-1
WARNING!
Make sure the speed dial is set to 0 % before turning on the power.
1. Verify that the SPEED DIAL is set to 0 %.
The shaker is turned on or off by the ON/OFF POWER SWITCH located on the rear panel of
the unit, not by the 0% setting of the SPEED DIAL. The 0% setting is the minimum speed at
which the shaker operates. We recommend starting and stopping the shaker at this speed.
2. Set the ON/OFF POWER SWITCH on the side of unit to the ON position.. The shaker will start shaking
at its minimum speed.
3. Adjust speed as desired.
15
The graduations around the SPEED DIAL are for reference only. They do not correspond to
specific speeds or any particular percent of maximum speed.
5.2Stopping the Shaker
To stop the shaker:
1. Turn the SPEED DIAL to the zero position.
2. Set the ON/OFF switch on the side of unit to the OFF position. The shaker will stop shaking.
5.3Power failure
In the event of a power failure, the Excella E-1 is equipped with an automatic restart function. If the shaker
was in operation at the time of the power interruption, the shaker will begin to operate at its last setpoint.
16
Operation
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Troubleshooting
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
6Troubleshooting
6.1Troubleshooting guide
If any problems occur with your shaker, do not attempt to perform any service on the shaker other than
specified in this manual. Unauthorized servicing may void the warranty. Please contact your local
Eppendorf Service Department.
In any correspondence with Eppendorf, please refer to the Model Number and Serial Number of your
shaker. This information is on the ELECTRICAL SPECIFICATION PLATE.
There are some problems that you can investigate and correct yourself. Refer to the following
Troubleshooting Guide:
SymptomsProbable Causes and Solutions
Shaker does not run.Power cord is not plugged in and/or power switch is off: plug in power cord (to
working electric outlet), and turn on power switch.
On/Off switch is not working: call for service.
Blown fuse: call for service.
Defective speed controller board: call for service
Jammed shaking mechanism: call for service
Defective motor: call for service
Drive belt out of alignment or worn: call for service.
Shaker runs slowly and/
or no speed indication.
Shaker does not run at
set speed.
Operating noiseLoad out of balance: unload all contents, then reload.
Blown fuse: call for service.
Drive belt out of alignment or worn: call for service.
Incorrect speed calibration: call for service
Defective speed control board: call for service.
Defective motor: call for service.
Defective motor: call for service.
Drive belt out of alignment or worn: call for service.
Loose components in platform, subplatform and/or drive assembly: call for
service.
17
18
Troubleshooting
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Maintenance
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
7Maintenance
7.1Cleaning external surfaces
WARNING!
Always turn off the shaker and disconnect the power cord from the power supply before
performing any maintenance on the shaker.
A detachable main power cord has been provided with your unit. Only use the cord
provided and do not replace cord with an inadequately rated cord.
Use a cloth dampened with water or any standard, household or laboratory cleaner to wipe down the
shaker’s outer surfaces.
Never use abrasive or corrosive compounds to clean this instrument, as they may damage the shaker and
void the warranty.
19
20
Maintenance
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
New Brunswick Excella® E-1 Open Air Shaker
8Technical data
8.1Specifications
Shaking
Speed50 rpm – 400 rpm
Motion1.91 cm (¾ in) diameter circular orbit
Drive
UniCentric™ single eccentric counterbalanced ball bearing drive
Operating ambient environment
•5 – 45 °C
•20 – 80 % humidity, non-condensing
• Up to 2000 m
Technical data
21
English (EN)
Automatic restart
• Shaker will automatically restart after undesired power interruption.
Electrical service
• 110V/120V AC, 50/60 Hz, 1320 VA
• 220V/240V AC, 50/60 Hz, 1320 VA
Dimensions
Width37 cm (14.5 in)
Depth44.5 cm (17.5 in)
Height18.8 cm (7.4 in)
Platform dimensions
Width × Depth33 cm (13 in) × 28 cm (11 in)
Weight
Net16 kg (35 lb)
Gross22.7 (50 lb)
22
Technical data
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Ordering information
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
9Ordering information
9.1Parts and accessories
When ordering replacement or accessory parts, or requesting service, please provide the Model Number
and Serial Number of your shaker. This information is on the ELECTRICAL SPECIFICATION PLATE
located on the rear of the shaker.
9.1.1Relacement parts
Part descriptionQuantityPart number
V-Belt1R-243
Fuse, Slo-Blo
®
4 A, 250 V
9.1.2Dedicated platforms
1P0380-3780
23
Platform descriptionFlask capacityPart number
10 ml Erlenmeyer Flasks60AG2-10
25 ml Erlenmeyer Flasks32M1190-9919
50 ml Erlenmeyer Flasks20M1194-9915
125 ml Erlenmeyer Flasks12M1194-9916
250 ml Erlenmeyer Flasks8M1194-9917
500 ml Erlenmeyer Flasks6M1194-9918
9.1.3Universal platform flask capacity
The following is a list of flask capacities for Universal Platform number M1001-0240. Flask clamps are
ordered separately.
Flask typeCapacity
10 ml Erlenmeyer60
25 ml Erlenmeyer Flasks20
50 ml Erlenmeyer Flasks15
125 ml Erlenmeyer Flasks11
250 ml Erlenmeyer Flasks6
500 ml Erlenmeyer Flasks4
9.1.4Accessory flask clamps
Clamp typePart number
10 ml Erlenmeyer Clamp, stainless steelACE-10S
24
Ordering information
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Clamp typePart number
25 ml Erlenmeyer Clamp, stainless steelM1190-9004
50 ml Erlenmeyer Clamp, stainless steelM1190-9000
125 ml Erlenmeyer Clamp, stainless steelM1190-9001
250 ml Erlenmeyer Clamp, stainless steelM1190-9002
500 ml Erlenmeyer Clamp, stainless steelM1190-9003
9.1.5Utility carrier, utility tray and test tube rack capacities
Accessory DescriptionPart Number
Utility Carrier with rubber mat and 2 bars for captivating
glassware
Utility tray with rubber mat for shaking 96-well plates, petri
dishes and other labware at low speeds
Test Tube Racks*
Test Tubes/RackTest Tube Diameter
488 – 11 mmM1285-0001
3412 – 15 mmM1285-0002
2415 – 18 mmM1285-0003
1818 – 21 mmM1285-0004
1322 – 26 mmM1285-0005
1226 – 30 mmM1285-0006
AG2-UT
AG2-00
* Limit 3 racks per shaker
Transport, storage and disposal
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
10Transport, storage and disposal
10.1Disposal
In case the product is to be disposed of, the relevant legal regulations are to be observed.
Information on the disposal of electrical and electronic devices in the European Community:
Within the European Community, the disposal of electrical devices is regulated by national regulations
based on EU Directive 2012/19/EU pertaining to waste electrical and electronic equipment (WEEE).
According to these regulations, any devices supplied after August 13, 2005, in the business-to-business
sphere, to which this product is assigned, may no longer be disposed of in municipal or domestic waste. To
document this, they have been marked with the following identification:
25
Because disposal regulations may differ from one country to another within the EU, please contact your
supplier if necessary.
In Germany, this is mandatory from March 23, 2006. From this date, the manufacturer has to offer a
suitable method of return for all devices supplied after August 13, 2005. For all devices supplied before
August 13, 2005, the last user is responsible for the correct disposal.
26
Transport, storage and disposal
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Declaration of conformity
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
11Declaration of conformity
The E-1 shaker has been tested to the appropriate standards as attested in the following Declaration of
Conformity.
27
28
Declaration of conformity
New Brunswick Excella® E-1 Open Air Shaker
English (EN)
Declaration of Conformity
The product named below fulfills the requirements of directives and standards listed. In the case of
unauthorized modifications to the product or an unintended use this declaration becomes invalid.
Product name:
Excella® E1
including accessories
Product type:
Benchtop open air shaker
Relevant directives / standards:
2006/95/EC: EN 61010-1, UL-61010-1, CAN/CSA-C22.2 No. 61010-1-12
2004/108/EC: EN 61326-1, EN 61000-3-2, EN 61000-3-3
2011/65/EU
2012/19/EU
Date: November 25, 2013
Your local distributor: www.eppen dorf.com/cont act
Eppendorf AG · 22331 Hamburg · Germany
eppendorf@eppendorf.com