EMERSON NTQ123 Service Manual

0 (0)
EMERSON NTQ123 Service Manual

70-120 Watts

NTQ123 Series

Special Features

Active power factor correction

EN61000-3-2 compliance

Remote sense on outputs one and two

Power fail and remote inhibit

Single wire current sharing on outputs one and two

Adjustable main outputs

Built-in Class B EMI filter

Overvoltage protection

Overload protection

Thermal overload protection

Environmental

Operating temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from

50° to 70°C

Electromagnetic susceptibility: Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3

Humidity: Operating; non-condensing 5% to 95%

Vibration: Three orthogonal axes, sweep at

1 oct/min, 5 min. dwell at four major resonances

0.7 G peak 5 Hz to 500 Hz, operational

Storage temperature: -40° to 85°C

Temperature coefficient: ± .04% per °C

MTBF demonstrated: >1 million hours at full load and 25°C ambient conditions

Total Power: 70-120 Watts

Input Voltage: 85-264 VAC

# of Outputs: Quad

Electrical Specs

Input

Input range

85-264 VAC

Frequency

47-63 Hz

Inrush current

38 A max., cold start @ 25°C

Efficiency

65% typical at full load

EMI filter

FCC Class B conducted and radiated,

 

CISPR 22 Class B conducted and

 

radiated, EN55022 Class B conducted

 

and radiated, VDE 0878 PT3 Class B

 

conducted and radiated.

Power factor

0.99 typical

Safety ground leakage

 

current

<1 mA @ 50/60 Hz, 264 VAC input

Output

Maximum power

70 W convection,

 

120 W with 30 CFM forced air

Adjustment range

±5% minimum on outputs one and two

Hold-up time

20 ms @ 120 W load, 120 VAC input

Overload protection

Short circuit protection on all outputs.

 

Case overload protected @ 110-145%

 

above peak rating

Overvoltage protection

3.3 V and 5 V output: 20% to 35%

Logic Control

above nominal output

 

Power failure

TTL logic signal goes high 100-500

 

msec after 5 V output; it goes low at

 

least 4 msec before loss of regulation

Remote inhibit

Requires an external TTL Signal to

 

inhibit outputs

Remote sense

Compensates for 0.5 V lead drop

 

minimum, will operate without remote

 

sense connected. Reverse connection

 

protection.

Safety

VDE

0805/EN60950 (IEC950)

21310-3336-0004

UL

UL1950

E186249

CSA

CSA 22.2-234 Level 3 LR109492C

NEMKO

EN 60950/EMKO-TUE P98100870

 

(74-sec) 203

 

BABT

EN60950/EN41003

608497

CB

Certificate and report

5009

CE

Mark (LVD)

 

 

Technical Support: (888) 41-ASTEC or (407) 241-2752

106

Americas: (760) 930-4600

Europe (UK) 44 (1384) 842-211

Asia (HK) 852-2437-9662

 

 

 

rev 10.19.04