Eaton Transmission TRIG0910 User Manual

Installation Guide
Eaton Automated Transmission Engine Configuration Settings Guide
TRIG0910 EN-US
September 2015
Table of Contents
Configuration Settings . . . . . . . . . . . . . . . . . . 1

Caterpillar

AutoShift Medium-Duty / Heavy-Duty . . . . . . . . 1
UltraShift ASW . . . . . . . . . . . . . . . . . . . . . . . . . 1
UltraShift Medium-Duty DM . . . . . . . . . . . . . . . 2
UltraShift Heavy-Duty DM . . . . . . . . . . . . . . . . 3
UltraShift PLUS Heavy-Duty . . . . . . . . . . . . . . . 3
Cummins
AutoShift Medium-Duty / Heavy-Duty . . . . . . . . 4
UltraShift ASW . . . . . . . . . . . . . . . . . . . . . . . . . 5
UltraShift Medium-Duty DM . . . . . . . . . . . . . . . 5
UltraShift Heavy-Duty DM . . . . . . . . . . . . . . . . . 6
Procision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Medium-Duty Hybrid. . . . . . . . . . . . . . . . . . . . . 8
UltraShift PLUS Heavy-Duty . . . . . . . . . . . . . . . 9
Hino
Ultrashift Medium Duty DM. . . . . . . . . . . . . . . . 11
International
EPA 2007 Emission Engine HT-570
AutoShift Heavy-Duty. . . . . . . . . . . . . . . . . . 11
EPA 2007 Emission Engine Maxx Force DT (DT-466)
UltraShift ASW . . . . . . . . . . . . . . . . . . . . . . . 11
UltraShift Medium-Duty DM. . . . . . . . . . . . . 11

EPA 2010 Emission Engine MaxxForce DT (DT-466)

UltraShift Medium-Duty DM. . . . . . . . . . . . . 12
Hybrid (HEV) . . . . . . . . . . . . . . . . . . . . . . . 12
EPA 2007 Emission Engines MaxxForce 11 and 13
UltraShift Heavy-Duty DM . . . . . . . . . . . . . . 13
UltraShift PLUS Heavy-Duty. . . . . . . . . . . . . 13
EPA 2010 Emission Engines MaxxForce 11 and 13
UltraShift Heavy-Duty DM . . . . . . . . . . . . . . 14
UltraShift PLUS Heavy-Duty. . . . . . . . . . . . . 14
International MaxxForce
Hybrid (HEV) . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Detroit Diesel Pre 2007
AutoShift Heavy-Duty . . . . . . . . . . . . . . . . . . 17
UltraShift Heavy-Duty DM . . . . . . . . . . . . . . . 17
EPA 2010 Emission Engines DD13, DD15, DD16
AutoShift - Heavy-Duty . . . . . . . . . . . . . . . . . 18
UltraShift - Heavy-Duty DM. . . . . . . . . . . . . . 19
UltraShift PLUS Heavy-Duty . . . . . . . . . . . . . 20
Detroit Diesel/Mercedes
EPA 2007 Emission Engines
AutoShift - Heavy-Duty . . . . . . . . . . . . . . . . . 19
UltraShift - Heavy-Duty DM. . . . . . . . . . . . . . 21
UltraShift PLUS Heavy-Duty . . . . . . . . . . . . . 22
Mercedes
Pre 2007
AutoShift Medium-Duty. . . . . . . . . . . . . . . . . 23
AutoShift Heavy-Duty . . . . . . . . . . . . . . . . . . 24
UltraShift ASW . . . . . . . . . . . . . . . . . . . . . . . 24
UltraShift Medium-Duty DM . . . . . . . . . . . . . 25
UltraShift Heavy-Duty . . . . . . . . . . . . . . . . . . 26
PACCAR MX 12.9L Engine
Configuration Settings . . . . . . . . . . . . . . . . . . .27
Volvo/Mack Engine Configuration
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Volvo/Mack Body Builder Module
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Change Control Log . . . . . . . . . . . . . . . . . . . . .28
Table of Contents
i
Engine Configuration

Automated Transmission Engine Configuration Settings

These engine configurations are for the following Fuller® Automated Transmissions.
AutoShift / UltraShift Gen 2 and Gen 3

Caterpillar

AutoShift Medium-Duty / Heavy-Duty
Programmable Parameter Table Required Setting
Engine Gear Parameters (Note: Gear RPM Limits disabled in Drive.)
Transmission Style
Governor Type Min/Max
Top Gear Ratio 0.780 for 6A, 0.740 for 10B, 0.730 for 10C,
Top Gear Minus one ratio 1.00 for 6A, 1.00 for 10B & 10C, 0.860 for 18A
Top Gear Minus two ratio 1.59 for 6A, 1.36 for 10B, 1.38 for 10C, 1.00 for 18A
Data Link Parameters
Powertrain Data Link J1939
Input Selections (2007 and Later Engines) Recommended
Transmission Neutral Switch J1939
Manual Option 1 (2006 and Earlier Engines)
Manual (2007 and Later Engines)
0.730 for 18A
UltraShift ASW
Programmable Parameter Table Required Setting
Engine Gear Parameters (Note: Gear RPM Limits disabled in Drive.)
Transmission Style
Governor Type Min/Max
Top Gear Ratio 0.780 for 6A
1
Automatic Option 1 (2006 and Earlier Engines)
Automatic (2007 and Later Engines)
Engine Configuration
Programmable Parameter Table Required Setting
Top Gear Minus one ratio 1.00 for 6A
Top Gear Minus two ratio 1.59 for 6A
Data Link Parameters
Powertrain Data Link J1939
Input Selections (2007 and Later Engines)
Transmission Neutral Switch J1939
UltraShift Medium-Duty DM
Programmable Parameter Table Required Setting
Engine Gear Parameters (Note: Gear RPM Limits disabled in Drive.)
Transmission Style
Governor Type Min/Max
Top Gear Ratio 0.780 for 6A HV OD, 1.00 for 5A HV DIR
Top Gear Minus one ratio 1.00 for 6A HV OD, 1.59 for 5A HV DIR
Configuration
Engine
Automatic Option 1 (2006 and Earlier Engines)
Automatic (2007 and Later Engines)
Top Gear Minus two ratio 1.59 for 6A HV OD, 2.52 for 5A HV DIR
Low Idle Engine RPM 700 rpm max
Data Link Parameters
Powertrain Data Link J1939
Input Selections (2007 and Later Engines)
Transmission Neutral Switch J1939
2
UltraShift Heavy-Duty DM
Programmable Parameter Table Required Setting
Engine Gear Parameters (Note: Gear RPM Limits disabled in Drive.)
Transmission Style
Governor Type Min/Max
Top Gear Ratio 0.740 for 10B LST OD, 1.00 for 10B LST DIR,
Top Gear Minus one ratio 1.00 for 10B LST OD, 1.34 for 10B LST DIR,
Top Gear Minus two ratio 1.36 for 10B LST OD, 1.83 for 10B LST DIR,
Low Idle Engine RPM 625 rpm max (Until further notification)
Engine Configuration
Automatic Option 1 (2006 and Earlier Engines)
Automatic (2007 and Later Engines)
0.730 for 13 LHP & LEP
0.860 for 13 LHP & LEP
1.00 for 13 LHP & LEP
Data Link Parameters
Powertrain Data Link J1939
Input Selections (2007 and Later Engines)
Transmission Neutral Switch J1939
UltraShift PLUS Heavy-Duty
Programmable Parameter Table Required Setting
Engine Gear Parameters (Note: Gear RPM Limits disabled in Drive.)
Transmission Style Automatic (2007 and Later Engines)
Governor Type Min/Max
Top Gear Ratio 0.74 for 8LL VCS
0.73 for 9ALL VMS
1.00 for 10B LAS DD
0.73 for 10C LAS OD
0.73 for 13A MHP
0.73 for 18B MXP
0.73 for 18B VXP
3
Engine Configuration
Programmable Parameter Table Required Setting
Top Gear Minus one ratio 1.00 for 8LL VCS
1.00 for 9ALL VMS
1.35 for 10B LAS DD
1.00 for 10C LAS OD
0.86 for 13A MHP
0.86 for 18B MXP
0.86 for 18B VXP
Top Gear Minus two ratio 1.36 for 8LL VCS
1.38 for 9ALL VMS
1.83 for 10B LAS DD
1.38 for 10C LAS OD
1.00 for 13A MHP
1.00 for 18B MXP
1.00 for 18B VXP
Configuration
Engine
Data Link Parameters
Powertrain Data Link J1939

Cummins

AutoShift Medium-Duty / Heavy-Duty
Features and Parameters Required Setting
Accelerator (or Governor) Type
Accelerator (or Governor) Type Automotive
Adjustable Low Idle Speed
Low Idle Speed
Low Idle Speed Adjustment Switch
Transmission Setup
Clutch Pedal Position Switch Installed
Transmission Type Fully Automated with Clutch Pedal (or Fully Automated if
clutch pedal distinction not present)
Gear down transmission ratio 1.00 for 6A, 1.00 for 10B & 10C, 0.860 for 18A
Top Gear Transmission ratio 0.780 for 6A, 0.740 for 10B, 0.730 for 10C,
0.730 for 18A
4
Engine Configuration
Features and Parameters Required Setting
Switched Maximum Engine Operating Speed
Maximum Switched Engine Speed Highest allowable rpm (min of high idle) Or Disable
PTO/Remote PTO Recommended
Service Brake Override in PTO Enable
Clutch Override in PTO Enable
UltraShift ASW
Features and Parameters Required Setting
Accelerator (or Governor) Type
Accelerator (or Governor) Type Automotive
Transmission Setup
Clutch Pedal Position Switch Not Installed
Transmission Type Fully Automated without Clutch Pedal
Gear down transmission ratio 1.00 for 6A
Top Gear Transmission ratio 0.78 for 6A
Switched Maximum Engine Operating Speed
Maximum Switched Engine Speed Highest allowable rpm (min of high idle) Or Disable
UltraShift Medium-Duty DM
Features and Parameters Required Setting
Accelerator (or Governor) Type
Accelerator (or Governor) Type Automotive
Remote Accelerator Disable
5
Engine Configuration
Features and Parameters Required Setting
Adjustable Low Idle Speed
Low Idle Speed 700 rpm max
Low Idle Speed Adjustment Switch Disable
Transmission Setup
Clutch Pedal Position Switch Not Installed
Transmission Type Fully Automated without Clutch Pedal
Gear down transmission ratio 1.00 for 6A HV OD, 1.59 for 5A HV DIR
Top Gear Transmission ratio 0.780 for 6A HV OD, 1.00 for 5A HV DIR
Switched Maximum Engine Operating Speed
Maximum Switched Engine Speed Highest allowable rpm (min of high idle) Or Disable
If PTO/Remote PTO is Enabled Required
PTO/Remote PTO
Service Brake Override in PTO Enable
Configuration
Engine
PTO/Remote PTO
PTO Resume Switch Speed 1000 rpm minimum
Clutch Override in PTO Disable
UltraShift Heavy-Duty DM
Features and Parameters Required Setting
Accelerator (or Governor) Type
Accelerator (or Governor) Type Automotive
Adjustable Low Idle Speed
Recommended
6
Engine Configuration
Features and Parameters Required Setting
Low Idle Speed 625 rpm max (2009 and earlier engines)
700 rpm max (2010 and later engines)
Low Idle Speed Adjustment Switch Disable
Transmission Setup
Clutch Pedal Position Switch Not Installed
Transmission Type Fully Automated without Clutch Pedal
Gear down transmission ratio 1.00 for 10B LST OD, 1.34 for 10B LST DIR,
0.860 for 13 LHP & LEP
Top Gear Transmission ratio 0.740 for 10B LST OD, 1.00 for 10B LST DIR,
0.730 for 13 LHP & LEP
Switched Maximum Engine Operating Speed
Maximum Switched Engine Speed Highest allowable rpm (min of high idle) Or Disable
If PTO/Remote PTO is Enabled Required
PTO/Remote PTO
Service Brake Override in PTO Enable
PTO/Remote PTO
PTO Resume Switch Speed 1000 rpm minimum
Clutch Override in PTO Disable
Procision
Features and Parameters Required Setting
Recommended
Transmission Setup
Transmission Type Duel Clutch Transmission (DCT)
Gear Down Transmission Ratio 0.76
Top Gear Ratio 0.64
7
Engine Configuration
Features and Parameters Required Setting
Aftertreatment Enable
Diesel Particulate Filter Regeneration Allowed in PTO and Other Modes
Fan Control
Fan on with Engine Braking Disable
Fast Idle Warmup
Fast Idle Warmup Enable
Fast Idle Warmup Idle Speed 1250 RPM
Adjustable Low Idle Speed
Low Idle Speed 750 RPM
Variable Rate Vehicle Acceleration Management Disable
Disable
Recommended Setting
Configuration
Engine
Medium-Duty Hybrid
Features and Parameters Required Setting
Accelerator Options
Remote Accelerator Pedal or Lever Disable, unless Approved by Eaton Application
Governor Type
Governor Type Automotive
Transmission Setup Enable
Transmission Type Fully Automated without Clutch Pedal
Gear Down Transmission Ratio 1.00 for 6A OD
Top Gear Transmission ratio 0.780 for 6A OD
Engineering
8
Engine Configuration
Features and Parameters Required Setting
Clutch Pedal Position Switch Not Installed
Switched Maximum Engine Operating Speed
Maximum Switched Engine Speed Disable
SAE J1939 Multiplexing
Auxiliary Shutdown Switch Enable
-Source Address 239
Clutch Pedal Position Switch Disable
If PTO is Enabled
Clutch Override Disable
Remote PTO Disable
Service Brake Override Enable
UltraShift PLUS Heavy-Duty
Features and Parameters Required Setting
Governor Type
Governor Type Automotive
Powertrain Protection Disable
Transmission Setup
Clutch Pedal Position Switch Not Installed
Transmission Type Fully Automated without Clutch Pedal
Gear Down Transmission Ratio 1.00 for 8LL VCS
1.00 for 9ALL VMS
1.35 for 10B LAS DD
1.00 for 10C LAS OD
0.86 for 13A MHP
0.86 for 18B MXP
0.86 for 18B VXP
9
Engine Configuration
Features and Parameters Required Setting
Top Gear Transmission Ratio 0.74 for 8LL VCS
0.73 for 9ALL VMS
1.00 for 10B LAS DD
0.73 for 10C LAS OD
0.73 for 13A MHP
0.73 for 18B MXP
0.73 for 18B VXP
Switched Maximum Engine Operating Speed Disable
If PTO/Remote PTO is Enabled
Service Brake Override Enable
Clutch Override Disable
Configuration
Engine
Vehicle Speed Anti-Tampering (If Enabled) 8LL VCS and 9ALL VMS ONLY
Tampering Sensitivity Level Low
SmartCoast Enable, if customer has purchased feature from
Cummins
10
Engine Configuration

Hino

Ultrashift Medium Duty DM
Please work with an authorized Hino dealer to verify engine configuration.

International (EPA 2007 Emission Engine HT-570)

AutoShift Heavy-Duty
Programmable Parameter Table Required Setting
Engine Parameters
Transmission Type Manual
Engine Family Rating Code 6122-330/1150

International (EPA 2007 Emission Engine MaxxForce DT (DT-466))

UltraShift ASW
Programmable Parameter Table Required Setting
Engine Parameters
Transmission Type Allison-MD
Engine Family Rating Code 2141-255/660
2131-245/620
2132-245/660
UltraShift Medium-Duty DM
Programmable Parameter Table Required Setting
11
Engine Gear Parameters
Transmission Type Allison-MD
Engine Family Rating Code 1121-210/520
1141-225/560
Engine Configuration
Programmable Parameter Table Required Setting
1122-225/620
2141-255/660
2131-245/620
2132-245/660

International (EPA 2010 Emission Engine MaxxForce DT (DT-466))

UltraShift Medium-Duty DM
Programmable Parameter Table Required Setting
Engine Gear Parameters
Transmission Type Allison-MD
Engine Family Rating Code 1121-210/520
1141-225/560
1122-225/620
2141-255/660
2131-245/620
2132-245/660
Configuration
Engine
Hybrid (HEV)
Programmable Parameter Table Required Setting
Engine Parameters
Transmission Type Eaton Hybrid (Allison-MD in Service Tool)
EFRC: ENgine Family Rating Code 1121-210/560
PTO: Remote Pedal Off, Unless Approved by Eaton Application Engineering
1131-225/560
1141-225/620
1151-230/620
2121-245/620
2131-255/660
12
Engine Configuration

International (EPA 2007 Emission Engines MaxxForce 11 and 13)

UltraShift Heavy-Duty DM
Features and Parameters Required Setting
Engine Family / Transmission
Transmission Type 8: Eaton Ultrashift
Low Idle Engine Speed 700 rpm maximum
Low Idle Speed Adjustable Maximum 700 rpm maximum
Vehicle Configuration
Speed Governor Enable 0: Torque Governor Enabled
Engine Fan Control
Engine Fan Control Mode 3: Variable Engine Fan Speed Control
Enable the fan on with engine braking feature 1: Enable (Navistar Requirement)
UltraShift PLUS Heavy-Duty
Features and Parameters Required Setting
Engine Family / Transmission
Transmission Type 8: Eaton Ultrashift
Vehicle Configuration
Speed Governor Enable 0: Torque Governor Enabled
Engine Fan Control
Engine Fan Control Mode 3: Variable Engine Fan Speed Control
13
Enable the fan on with engine braking feature 1: Enable (Navistar Requirement)
Engine Configuration

International (EPA 2010 Emission Engines MaxxForce 11 and 13)

UltraShift Heavy-Duty DM
Features and Parameters Required Setting
Engine Family / Transmission
Transmission Type 8: Eaton Ultrashift
Low Idle Engine Speed 700 rpm maximum
Low Idle Speed Adjustable Maximum 700 rpm maximum
Engine Fan Control
Engine Fan Control Mode 1.0: On/Off Control OR
UltraShift PLUS Heavy-Duty
Features and Parameters Required Setting
Engine Family / Transmission
Transmission Type 8: Eaton Ultrashift
Vehicle Configuration
Configuration
Engine
2.0: Variable Engine Fan Speed Control
High Idle Engine Speed 2100-2200 rpm
Engine Fan Control
Engine Fan Control Mode 1.0: On/Off Control OR
2.0: Variable Engine Fan Speed Control
14
UltraShift PLUS Heavy-Duty
Engine Gear Parameters
Engine Configuration
ID Gear
Number Calcula-
tion
Gear #
82201 1 GNCG1 18
Abbrevi-
ation
Value ID Gear
Number Calcula-
tion
Ratio #
82431 1 GNCR1 NA NA 0.73 NA NA NA NA NA
Abbrevi-
ation
10C LAS
10B LAS
MXP
VXP
VMS VCS MHP 10-Sp
DM3
10B LST
82211 2 GNCG2 17 82441 2 GNCR2 NA NA 0.86 NA NA NA NA NA
82221 3 GNCG3 16 82451 3 GNCR3 NA NA 1.00 NA NA NA NA NA
82231 4 GNCG4 15 82461 4 GNCR4 NA NA 1.17 NA NA NA NA NA
82241 5 GNCG5 14 82471 5 GNCR5 NA NA 1.38 NA NA NA NA NA
82251 6 GNCG6 13 82481 6 GNCR6 NA NA 1.62 NA NA 0.73 NA NA
82261 7 GNCG7 12 82491 7 GNCR7 NA NA 1.94 NA NA 0.86 NA NA
82271 8 GNCG8 11 82501 8 GNCR8 NA NA 2.28 0.73 NA 1.00 NA NA
82281 9 GNCG9 10 82511 9 GNCR9 0.73 1.00 2.73 1.00 0.74 1.17 0.74 1.00
82291 10 GNCG10 9 82521 10 GNCR10 1.00 1.34 3.20 1.38 1.00 1.38 1.00 1.34
82301 11 GNCG11 8 82531 11 GNCR11 1.38 1.83 3.74 1.95 1.36 1.62 1.36 1.83
82311 12 GNCG12 7 82541 12 GNCR12 1.89 2.46 4.38 2.77 1.83 1.95 1.83 2.46
82321 13 GNCG13 6 82551 13 GNCR13 2.61 3.30 5.16 3.79 2.53 2.29 2.46 3.31
82331 14 GNCG14 5 82561 14 GNCR14 3.58 4.67 6.05 5.23 3.40 3.20 3.32 4.46
82341 15 GNCG15 4 82571 15 GNCR15 4.90 6.28 7.29 7.41 4.63 4.38 4.46 6.00
82351 16 GNCG16 3 82581 16 GNCR16 6.76 8.55 8.51 11.85 6.24 6.05 6.07 8.17
82361 17 GNCG17 2 82591 17 GNCR17 9.25 11.52 12.29 16.30 9.42 8.51 8.18 11.00
82371 18 GNCG18 1 82601 18 GNCR18 12.80 15.42 14.40 26.08 14.56 12.29 10.96 14.78
82381 19 GNCG19 -2 82611 19 GNCR19 NA NA NA NA NA NA NA NA
Gear Number Values on Left Correspond to Ratio Values on Right
82391 20 GNCG20 -2 82621 20 GNCR20 NA NA NA NA NA NA NA NA
82401 21 GNCG21 -2 82631 21 GNCR21 NA NA NA NA NA NA NA NA
82411 22 GNCG22 -2 82641 22 GNCR22 NA NA NA NA NA NA NA NA
82421 23 GNCG23 -2 82651 23 GNCR23 NA NA NA NA NA NA NA NA
Note: For engine parameters not listed above, please refer to the engine manufactures programming guide.
Note: In order for Progressive Shift and Gear Down protection to work correctly, the gear number and ratio information must be
set correctly. Progressive Shift and Gear Down protection settings can effect transmission operation and should be reviewed when diagnosing a shift complaint.
15

International MaxxForce

Hybrid (HEV)
Programmable Parameter Table Required Setting
Engine Parameters
Engine Configuration
Transmission Type Eaton Hybrid (Allison-MD in Service Tool)
EFRC: ENgine Family Rating Code 1121-210/560
1131-225/560
1141-225/620
1151-230/620
2121-245/620
2131-255/660
PTO: Remote Pedal Off, Unless Approved by Eaton Application Engineering
Configuration
Engine
16

Detroit Diesel (pre 2007)

AutoShift Heavy-Duty
Calibration Parameters Required Setting
Transmission Type 16 – AutoShift J1939 Transmission
UltraShift Heavy-Duty DM
Calibration Parameters Required Setting
Transmission Type 14 – Automatic w/magnetic speed sensor
Engine Configuration
33 – Eaton Fuller Automatic w/J1939 Speed
(Setting the listed transmission types above sets a maximum warmup speed of 700 rpm.)
Enable_VSG_switch OFF or limit below
VSG_max_rpm 650 rpm
Analog D1 510 (DDEC IV) NONE (No analog PTO input allowed)

Detroit Diesel (EPA 2010 Emission Engines DD13, DD15, DD16)

AutoShift - Heavy-Duty
Parameter Group Parameters Required Setting
MCM2 Trans Limp Home Mode 1- Automatic
2 Transmission Type DIRECT ENGINE START
2 - Eaton AutoShift Direct Start MCM ENGINE START 5 - Eaton AutoShift MCM Start
3 Max Engine Speed 3000 rpm (to allow for engine
protection upshift)
5 LIM0, LIM1, LIM2 1800 rpm or higher
10 Eng Brk Driveline Clsd Min Spd 800 rpm
10 Min Eng Spd for Engine Brakes 1100 rpm
13 Clutch Switch Config 1 - Clutch Switch
13 4 08 DI Selection 1 - Clutch Switch
13 Trans Neutral Input Config 1 - Info from J1939
17
Engine Configuration
UltraShift - Heavy-Duty DM
Parameter Group Parameters Required Setting
MCM2 Trans Limp Home Mode 1= Automatic
2 Transmission Type DIRECT ENGINE START
2 = Eaton UltraShift Direct Start MCM ENGINE START 5 = Eaton UltraShift MCM Start
3 Adjusted Idle Configuration 0 = Disabled
3 = Enabled if Neutral and Park Brake
3 Max Adjusted Idle Speed <700 rpm
3 Max Engine Speed 3000 rpm (to allow for engine
protection upshift)
3 Min Engine Speed <700 rpm
5 LIM0, LIM1, LIM2 1800 rpm or higher
Configuration
Engine
6 Fast Idle Spd Air Cond Input <700 rpm
7 Configuration PTO Speed Control 3 = Enable if Neutral and park brake
0 = Disable
7 Max Road Speed in PTO Mode 10.0 km/h or 6 mi/h (default)
7 PTO Droptout Serv Brk Prk Brk If PTO is enabled,
2 = PTO Drops out on Service Brake Activation
8 Anti Tamper (Vehicle Speed Tamper) 0 = Disabled
8 Vehicle Speed Sensor 3 = J1939 (ETC1)
10 Eng Brk Driveline Clsd Min Spd 800 rpm
10 Min Eng Spd for Engine Brakes 1100 rpm
13 Clutch Switch Config 0 = Disabled (No Clutch Switch)
13 4 08 DI Selection 0 = Disabled
13 Trans Neutral Input Config 1 = Info from J1939
15 Enabled Cruise Auto Resume 3 = Resume AMT Style
UltraShift PLUS Heavy-Duty
Parameter Group Parameters Required Setting
2 Transmission Type MCM ENGINE START
5 = Eaton UltraShift MCM2 Start
3 Max Engine Speed > 2000 rpm
18
Engine Configuration
Parameter Group Parameters Required Setting
5 Limiter0 Max Eng Speed Enabled > 2000 rpm
5 Limiter1 Max Eng Speed Enabled > 2000 rpm
7 Configuration PTO Speed Control 3 = Enable if Neutral and park brake
0 = Disable
8 Vehicle Speed Sensor 3 = J1939 (ETC1)
10 Eng Brk Driveline Clsd Min Spd 800 rpm
10 Min Eng Spd for Engine Brakes 1100 rpm
13 Clutch Switch Config 0 = Disabled (No Clutch Switch)
13 4 08 DI Selection 0 = Disabled
13 Trans Neutral Input Config 1 = Info from J1939 (Multiplexed)
15 Enabled Cruise Auto Resume 3 = Resume AMT Style
MCM2 4_1_EngineConfig
Trans Limp Home Mode 1 = Automatic

Detroit Diesel/Mercedes (EPA 2007 Emission Engines)

AutoShift - Heavy-Duty
Parameter Group Parameters Required Setting
MCM Trans Limp Home Mode 1- Automatic
2 Transmission Type DIRECT ENGINE START
2 - Eaton AutoShift Direct Start MCM ENGINE START 5 - Eaton AutoShift MCM Start
3 Max Engine Speed 3000 rpm (to allow for engine
protection upshift)
5 LIM0, LIM1, LIM2 1800 rpm or higher
10 Eng Brk Stage 1 Off Delay Time 60 ms - Series 60DD15 Engine
240ms - MBE 900/4000
10 Eng Brk Stage 2 Off Delay Time 60 ms - Series 60/DD15 Engine
240 ms - MBE 900/4000
10 Eng Brk Stage 3 Off Delay Time 60 ms - Series 60/DD15 Engine
240 ms - MBE 900/4000
10 Stage 1 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
19
Engine Configuration
Parameter Group Parameters Required Setting
10 Stage 2 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
10 Stage 3 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
10 Eng Brk Driveline Clsd Min Spd 800 rpm
10 Min Eng Spd for Engine Brakes 1100 rpm
10 Trans Mask Engine Brake Series 60 - 81 : decompression valve
and turbo brake or Jake Brake 3rd stage DD15 Engine - 64: decompression valve only or Jake Brake 1st Stage MBE 4000 - 0: no engine brake activation
Configuration
Engine
10 Trans Factor Engine Brake 100
13 Clutch Switch Config 1 - Clutch Switch
13 4 08 DI Selection 1 - Clutch Switch
13 Trans Neutral Input Config 1 - Info from J1939
22 0 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 1 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 2 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 3 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
23 Acceleration Limiter Ramp Up Rate 160 rpm/sec (default) or higher (Al
Guide states S60 should be 120 rpm/ sec)
44 Mode Shift ECAN Status Enable 0 - Disable - Series 60/MBE 900/
DD15 1 - Enable - MBE 4000
UltraShift - Heavy-Duty DM
Parameter Group Parameters Required Setting
MCM Trans Limp Home Mode 1- Automatic
20
Engine Configuration
Parameter Group Parameters Required Setting
2 Transmission Type DIRECT ENGINE START
2 - Eaton UltraShift Direct Start MCM ENGINE START 5 - Eaton UltraShift MCM Start
3 Adjusted Idle Configuration 0 - Disabled
3 - Enabled if Neutral and Park Brake
3 Max Adjusted Idle Speed <650 rpm
3 Max Engine Speed 3000 rpm (to allow for engine
protection upshift)
3 Min Engine Speed <650 rpm
5 LIM0, LIM1, LIM2 1800 rpm or higher
6 Fast Idle Spd Air Cond Input <700 rpm
7 Configuration PTO Speed Control 3 - Enable if Neutral and park brake
0 - Disable
7 Max Road Speed in PTO Mode 10.0 km/h or 6 mi/h (default)
7 PTO Droptout Serv Brk Prk Brk If PTO is enabled,
2 - PTO Drops out on Service Brake Activation
8 Anti Tamper (Vehicle Speed Tamper) 0 - Disabled
8 Vehicle Speed Sensor 3 - J1939 (ETC1)
10 Trans Mask Engine Brake Series 60 - 81 : decompression valve
and turbo brake or Jake Brake 3rd stage DD15 Engine - 64: decompression valve only or Jake Brake 1st Stage MBE 4000 - 0: no engine brake activation
10 Trans Factor Engine Brake 100
10 Eng Brk Stage 1 Off Delay Time 60 ms - Series 60DD15 Engine
240 ms - MBE 900/4000
10 Eng Brk Stage 2 Off Delay Time 60 ms - Series 60/DD15 Engine
240 ms - MBE 900/4000
10 Eng Brk Stage 3 Off Delay Time 60 ms - Series 60/DD15 Engine
240 ms - MBE 900/4000
10 Stage 1 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
21
Engine Configuration
Parameter Group Parameters Required Setting
10 Stage 2 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
10 Stage 3 Eng Brk Off Delta Spd 250 rpm - Series 60
200rpm - DD15 100rpm - MBE 900/4000
10 Eng Brk Driveline Clsd Min Spd 800 rpm
10 Min Eng Spd for Engine Brakes 1100 rpm
13 Clutch Switch Config 0 - Disabled (No Clutch Switch)
13 4 08 DI Selection 0 - Disabled
13 Trans Neutral Input Config 1 - Info from J1939
15 Enabled Cruise Auto Resume 1- Enable automatic resume function
after clutch has been released once
Configuration
Engine
22 0 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 1 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 2 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
22 3 Speed Gov TSC1 Condition 0 - Series 60/DD15/MBE 4000
16 - MBE 900
23 Acceleration Limiter Ramp Up Rate 160 rpm/sec (default) or higher (Al
Guide states S60 should be 120 rpm/ sec)
23 AL Conditions 1 - No AL During Shift
44 Mode Shift ECAN Status Enable 0 - Disable - Series 60/MBE 900/
DD15 1 - Enable - MBE 4000
UltraShift PLUS Heavy-Duty
Parameter Group Parameters Required Setting
MCM Trans Limp Home Mode 1- Automatic
2 Transmission Type DIRECT ENGINE START
2 - Eaton UltraShift Direct Start MCM ENGINE START 5 - Eaton UltraShift MCM Start
22
Engine Configuration
Parameter Group Parameters Required Setting
3 Adjusted Idle Configuration 0 - Disabled
3 - Enabled if Neutral and Park Brake
3 Maximum Engine Speed 3000 rpm (to allow for engine
protection upshift)
5 LIMO, LIM1, LIM2 1800 rpm or higher
7 Configuration PTO Speed Control 0 - Disable
3 - Enable if Neutral and Park Brake
8 Anti-Tamper (Vehicle Speed Tamper) 0 - Disabled
8 Vehicle Speed Sensor 3 - J1939 (ETC1)
13 Clutch Switch Config 0 - Disabled (No Clutch Switch)
13 4 08 DI Selection 0 - Disabled
13 Trans Neutral Input Config 1 - Info from J1939
15 Enable Cruise Auto Resume 1 - Enable automatic resume function
after clutch has been released once
22 0 Speed Gov TSC1 Condition 0 - Series 60/DD15 Engine/MBE 4000
16 - MBE 900
22 1 Speed Gov TSC1 Condition 0 - Series 60/DD15 Engine/MBE 4000
16 - MBE 900
22 2 Speed Gov TSC1 Condition 0 - Series 60/DD15 Engine/MBE 4000
16 - MBE 900
22 3 Speed Gov TSC1 Condition 0 - Series 60/DD15 Engine/MBE 4000
16 - MBE 900
23 Acceleration Limiter Ramp Up Rate 160 rpm/sec (default) or higher
(AI Guide states S60 should be 120 rpm/sec)
23 AL Conditions 1 - No AL During Shift
44 Mode Shift
ECAN Status Enable
0 - Series 60/MBE 900/DD15 Engine 1 - MBE 4000

Mercedes (pre 2007)

AutoShift Medium-Duty
Calibration Parameters Required Setting
1 02 01 Transmission Type 1 (Automated with clutch switch)
1 05 xx LIM0, LIM1, LIM2 1800 rpm or higher
23
Engine Configuration
Calibration Parameters Required Setting
1 03 02 Maximum Engine Speed 3000 rpm (to allow for engine protection upshift)
1 10 20 Engine Brake Transmission Mask 16, if exhaust flap otherwise 64, decompression
1 13 07 Enable Transmission Neutral Input 0, J1939
Engine Brake Transmission Factor Parameter 19 = 100
1 23 06, 07 Progressive Shift Limiters No Limits (leave 3000 rpm default)
1 19 01 Enable Automatic Fan on Engine brk. 0, disable
1 23 10 Acceleration Limiter Ramp Rate 160 rpm/sec or higher
AutoShift Heavy-Duty
Calibration Parameters Required Setting
1 02 01 Transmission Type 1 (Automated with clutch switch)
1 05 xx LIM0, LIM1, LIM2 1800 rpm or higher
1 03 02 Maximum Engine Speed 3000 rpm (to allow for engine protection upshift)
1 10 20 Engine Brake Transmission Mask 16, if exhaust flap otherwise 64, decompression
1 13 07 Enable Transmission Neutral Input 0, J1939
Engine Brake Transmission Factor Parameter 19 = 100
1 23 06, 07 Progressive Shift Limiters No Limits (leave 3000 rpm default)
Configuration
Engine
1 19 01 Enable Automatic Fan on Engine brk. 0, disable
1 23 10 Acceleration Limiter Ramp Rate 160 rpm/sec or higher
UltraShift ASW
Calibration Parameters Required Setting
PLD Group 0 01 02 Manual/Automatic Trans 0 MANUAL
1 02 01 Transmission Type 2 (Automatic Trans without clutch switch)
1 03 01 Minimum Engine Speed 800-900 rpm
1 03 02 Maximum Engine Speed 3000 rpm (to allow for engine protection upshift)
(NOT 1 Automatic; engine speed may go to 1300 rpm with CAN failure.)
Allison name may appear for this setting
24
Calibration Parameters Required Setting
1 03 10 Max Adj. Idle Speed 900 rpm
1 05 xx LIM0, LIM1, LIM2 2200 rpm or higher
1 08 10 Anti Tamper (Vehicle Speed Tamper) 0, disabled
1 13 07 Enable Transmission Neutral Input 0, J1939
1 23 06, 07 Progressive Shift Limiters No Limits (leave 3000 rpm default)
1 23 10 Acceleration Limiter Ramp Rate 160 rpm/sec or higher
UltraShift Medium-Duty DM
Calibration Parameters Required Setting
Engine Configuration
PLD Group 0 01 02 Manual/Automatic Trans 0 MANUAL
(NOT 1 Automatic; engine speed may go to 1300 rpm with CAN failure.)
1 02 01 Transmission Type 2 (Automatic Trans without clutch switch)
Allison name may appear for this setting
1 03 02 Maximum Engine Speed 3000 rpm (to allow for engine protection upshift)
1 03 10 Max Adj. Idle Speed 650 rpm or lower
1 05 xx LIM0, LIM1, LIM2 1800 rpm or higher
1 06 01 Enable Fast Idle on AC 1, enable fast idle only in Neutral
1 07 01 Configuration PTO Speed Control 3, enable if neutral and park brake – or 2, neutral
1 07 08 PTO Max Vehicle Speed 2 mph
1 07 06 PTO Dropout on Service Brake 2, Dropout on service brake
1 08 10 Anti Tamper (Vehicle Speed Tamper) 0, disabled
1 10 20 Engine Brake Transmission Mask 16, if exhaust flap otherwise 64, decompression
Engine Brake Transmission Factor 100 (parameter 19)
25
1 13 07 Enable Transmission Neutral Input 0, J1939
1 19 01 Enable Automatic Fan on Engine brk. 0, disable
1 23 06, 07 Progressive Shift Limiters No Limits (leave 3000 rpm default)
1 23 10 Acceleration Limiter Ramp Rate 160 rpm/sec or higher
UltraShift Heavy-Duty
Calibration Parameters Required Setting
PLD Group 0 01 02 Manual/Automatic Trans 0 MANUAL
1 02 01 Transmission Type 2 (Automatic Trans without clutch switch)
1 03 02 Maximum Engine Speed 3000 rpm (to allow for engine protection upshift)
1 03 10 Max Adj. Idle Speed 650 rpm or lower
1 05 xx LIM0, LIM1, LIM2 1800 rpm or higher
1 06 01 Enable Fast Idle on AC 1, enable fast idle only in Neutral
Engine Configuration
(NOT 1 Automatic; engine speed may go to 1300 rpm with CAN failure.)
Configuration
Engine
Allison name may appear for this setting
1 07 01 Configuration PTO Speed Control 3, enable if neutral and park brake – or 2, neutral
1 07 08 PTO Max Vehicle Speed 2 mph
1 07 06 PTO Dropout on Service Brake 2, Dropout on service brake
1 08 10 Anti Tamper (Vehicle Speed Tamper) 0, disabled
1 10 20 Engine Brake Transmission Mask 16, if exhaust flap otherwise 64, decompression
Engine Brake Transmission Factor 100 (parameter 19)
1 13 07 Enable Transmission Neutral Input 0, J1939
1 19 01 Enable Automatic Fan on Engine brk. 0, disable
1 23 06, 07 Progressive Shift Limiters No Limits (leave 3000 rpm default)
1 23 10 Acceleration Limiter Ramp Rate 160 rpm/sec or higher
For engine parameters not listed above, please refer to the engine manufactures programming guide.
Other applicable documents:
1. • Maximum Engine Load in PTO
–Eaton FUL-169 & FUL-169U requirements
2. • Maximum PTO Speed
–Eaton FUL-169 & FUL-169U requirements
26
Engine Configuration

PACCAR MX 12.9L Engine Configuration Settings

Feature and Parameters Required Setting
Auto-Retard Vehicle Speed Offset (N014) 4 MPH, if NeutralCoast is active on Transmission
Please work with an Authorized Kenworth or Peterbilt Dealer to verify engine configuration.
Any feature change may be specified during the vehicle order process. Changing transmission features require new engine soft­ware. Dealers will need to submit a SupportNet case to the PACCAR Engine Support Center to obtain updated software.
If there is a question, the dealer can call the PACCAR Engine Support Center to determine the proper vehicle configuration.

Volvo/Mack Engine Configuration Settings

Please work with an Authorized Volvo or Mack Dealer to verify engine configuration.
The dealer can refer to the COLA system that can associate the proper sub-data set for the transmission/engine combination. Using Professional Tech Tool (PTT) or VCADS service tool, the dealer can confirm that the vehicle is configured properly. If there is a question, the dealer can call Volvo’s eService help desk to determine the original sub-data sets for proper vehicle configura tion.
-

Volvo/Mack Body Builder Module Settings

Parameter ID: DXM (EngSpd Limit) must be set to 0 (OFF)
Please work with an Authorized Volvo or Mack Dealer to verify all other Body Builder Module Settings.
27
Change Control Log
Change Control Log
Change Control Log
Last Revised Date Description of Clarifications and Updates
Sep 2015 Added SmartCoast settings for Cummins UltraShift PLUS Heavy-Duty
Added Procision Transmission settings Updated PACCAR MX 12.9L Engine Configuration Settings
Nov 2014 Changed all settings for UltraShift PLUS MHP from 13B to 13A.
Oct 2011 Added High Idle Engine Speed to the UltraShift PLUS Heavy-Duty section, along with the Engine Gear
Parameters Table Added UltraShift PLUS Heavy-Duty Parameters Table to Detroit Diesel (EPA 2010 Emission Engines DD13, DD15, DD16 Section Moved the Detroit Diesel (EPA 2010 Emission Engines DD13, DD15, DD16) AutoShift - Heavy-Duty Ta­ble to be before the Detroit Diesel (EPA 2010 Emission Engines DD13, DD15, DD16) UltraShift - Heavy­Duty DM Table Rearranged the engine Configuration types for usability
Dec 2010 Added sections for 2010 Maxxforce DT engine, Hino, and Maxxforce 11 & 13 for 2010
Sep 2010 Updated Engine Configuration Settings for Volvo and Mack
Dec 2009 Change ECA to UltraShift PLUS, minor changes to UltraShift PLUS tables, add 2010 Detroit Diesel /
Mercedes engine information, add International EPA 2007 engine information
Feb 2009 Add Heavy-Duty ECA tables for Cummins, Caterpillar, and Detroit Diesel / Mercedes
July 2008 Updated International/Maxxforce with Hybrid engine configuration settings, Added Cummins with
Hybrid engine configuration settings, Added DDEC/MBE engine configuration settings for 2007 and later
May 2008 Changed title from Installation Guide to Engine Configuration
Jun 2007 Updated Caterpillar and Cummins engine configuration settings pages 1, 3, 4, 5, 7, and 8
Jan 2007 Update Engine Configuration Settings, Add new covers, Add Change Control Log
28
Copyright Eaton, 2015. Eaton hereby grant their customers, vendors, or distributors permission to freely copy, reproduce and/or distribute this document in printed format. It may be copied only in its entirety without any changes or modifications. THIS INFORMATION IS NOT INTENDED FOR SALE OR RESALE, AND THIS NOTICE MUST REMAIN ON ALL COPIES.
Note: Features and specifications listed in this document are subject to change without notice and represent the maximum capabilities of the software and products with all options installed. Although every attempt has been made to ensure the accuracy of information contained within, Eaton makes no representation about the completeness, correctness or accuracy and assumes no responsibility for any errors or omissions. Features and functionality may vary depending on selected options.
For spec’ing or service assistance, call 1-800-826-HELP (4357) or visit www.eaton.com/roadranger. In Mexico, call 001-800-826-4357.
Roadranger: Eaton and trusted partners providing the best products and services in the industry, ensuring more time on the road.
Eaton
Vehicle Group P.O. Box 4013 Kalamazoo, MI 49003 USA 800-826-HELP (4357) www.eaton.com/roadranger
Printed in USA
Loading...