CALYBOX
Energy manager
6050391 |
6050392 |
CALYBOX 220 or 230 - 2 or 3 domotics zones |
6050394 |
6050395 |
CALYBOX 420 or 430 - 2 or 3 domotics zones |
|
|
with alarm control |
CALYBOX
*2701543_Rev.1*
Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore.
Presentation
This unit optimizes the energy management of your home:
•Comfort or Economy programming for the heating in 2 zones (CALYBOX 220 or 420) or 3 zones (CALYBOX 230 or 430),
•reduction in the subscription costs by preventing the circuit-breakers from tripping when the electricity consumption is too great (load shedding),
•indication of the electricity consumption of the system.
This unit is compatible with the domotics products of the Delta Dore range (door/window magnetic contacts, remote controls, control unit, transmitter, etc.).
The CALYBOX 420 or 430 can control your alarm by means of a badge, ref.: 6413224 (supplied).
To control the heat emitters, the programmer uses the Pilot Wire.
Heat emitters
Programmer
Pilot Wire orders
Pilot wire
Independent from the power supply of the heat emitter,
the Pilot Wire is used to send the Comfort ,
Economy , Frost Protection or Shutdown orders requested by the programmer.
The required temperature is set on the thermostat of each heat emitter (convectors, panel heaters, underfloor heating or radiant ceiling heating, towel warmer radiators, storage heaters, etc.)..
Pilot Wire |
|
Room |
||||||
order |
Setting on the heat emitter |
|||||||
temperature |
||||||||
(mode) |
|
|||||||
|
|
|||||||
Comfort |
Comfort setting (thermostat knob) |
19°C |
||||||
|
|
|
|
|
|
example : 19°C |
||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
Economy |
Economy setting (thermostat knob) |
|
||||||
|
|
|
|
|
|
example : 16°C |
16°C |
|
|
|
|
|
|
|
or Comfort –X°C |
||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
(depending on heat emitter model) |
|
|
|
|
|
|
|
|
|
|
|
Absence |
Frost protection set to 7°C or 8°C |
|
||||||
|
|
|
|
|
|
(depending on model) |
7°C or 8°C |
|
|
|
|
|
|
|
|
|
|
Shutdown |
Heating shutdown |
No heating |
||||||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IMPORTANT: The heat emitter must be in automatic mode (PROG, AUTO, , etc. depending on model).
- 2 - |
- 3 - |
Warnings
•Carefully read these instructions prior to use.
•Do not attempt to repair the unit yourself; aftersales service is available.
Options
TYWATT 500 (ref. : 6110014)
Depending on your installation, the TYWATT 500, together with the CALYBOX, allows you to know the electricity consumption (in euros) of the heating, the water heater (DHW) and other electrical appliances (lights, household appliances, etc).
TYPHONE 500 (ref. : 6201029)
Combined with the CALYBOX, the TYPHONE 500 is used to control the heating system and the water heater (DHW) remotely by telephone.
MINOR 500 (ref : 6151041)
Regulates an underfloor heating or radiant ceiling heating system. In combination with the CALYBOX, this unit is used to control the set points and determine the room temperature measured by each probe.
Radio outdoor probe (ref.: 6300036)
Combined with the CALYBOX, the radio outdoor probe is used to know the outside temperature.
- 4 -
Contents
Description . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Automatic mode . . . . . . . . . . . . . . . . . . . . . . . .7 Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Timer mode . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Continuous mode . . . . . . . . . . . . . . . . . . . . . .10 Absence mode . . . . . . . . . . . . . . . . . . . . . . . .11 Shutdown mode . . . . . . . . . . . . . . . . . . . . . . .12 Information button . . . . . . . . . . . . . . . . . . . .12 Time setting . . . . . . . . . . . . . . . . . . . . . . . . .15 Programming . . . . . . . . . . . . . . . . . . . . . . . . .16
1. Create your program . . . . . . . . . . . . . . . . . . . . |
.16 |
2. Copy the program . . . . . . . . . . . . . . . . . . . . . . |
.16 |
3. Confirm the program . . . . . . . . . . . . . . . . . . . . . |
16 |
MINOR 500 option . . . . . . . . . . . . . . . . . . . . .19 Domotics functions . . . . . . . . . . . . . . . . . . . .20 Night time overventilation . . . . . . . . . . . . . . . 26 CALYBOX 420/430: alarm control . . . . . . . . . . 27 Tempo tariff . . . . . . . . . . . . . . . . . . . . . . . . .30 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 31
Description
This guide is common to the CALYBOX 220, 230, 420 or 430.
CALYBOX
Modification buttons
Selector knob position
Selector knob
Shutdown mode |
Time setting |
Absence mode |
Programming |
Timer mode |
|
Automatic mode |
|
Continuous mode |
|
Automatic mode
Turn the knob to AUTO.
CALYBOX 220 or 420 follows the programming in both zones.
|
Current mode in |
Time |
zones 1 and 2 |
Current day |
Override for zone 1 |
|
|
|
Override for zone 2 |
Room |
|
temperature |
|
Information button
Display in automatic mode
CALYBOX 230 or 430 follows the programming in the 3 zones.
|
Current mode in |
Time |
zones 1, 2 and 3 |
Current day |
Override for zone 1 |
|
|
|
Override for zone 2 |
Room |
|
temperature |
Override for zone 3 |
|
Information button |
Display in automatic mode |
- 6 - |
- 7 - |
Override
In automatic mode, override is used to go from Comfort to Economy mode (or conversely) until the next program change.
Example: it is 15:30 and you would like to switch to Comfort mode before the set time (17:00).
00:00 |
6:00 |
8:00 |
15:30 |
17:00 |
23:00 00:00 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current day programming on zone 1
Press the override button of zone 1.
Current override on zone 1.
To cancel the current override, |
At 17:00, the program will |
press the button once more. |
return to its usual program. |
Timer mode
This mode is used to select a mode for a given time and for one zone only. Turn the knob to
Zone selection
(the other zones are in AUTO mode)
Confirm
Selection of the Economy or Comfort mode
Confirm
Adjustment of the duration from 15 minutes to 72 hours (in increments of 15 minutes)
Confirmation and start of the countdown
To cancel the current |
|
|
|
|
|
|
|
|
Return to AUTO mode at |
||||||||
timer mode, turn the knob. |
||||||||
the end of the countdown |
- 8 - |
- 9 - |
Continuous mode
This mode allows you to choose a continuous mode for each of the zone.
Turn the knob to , then press the modification button of the relevant zone to select the Comfort , or Economy , mode.
CALYBOX 220 or 420
Room temperature
CALYBOX 230 or 430
Room temperature
Current modes in zones 1 and 2
Modification of the mode in zone 1
Modification of the mode in zone 2
Current modes
in zones 1, 2 and 3
Modification of
the mode in zone 1
Modification of
the mode in zone 2
Modification of
the mode in zone 3
To exit this mode, turn the knob.
Absence mode
This mode lets you place your home under Frost Protection if you need to leave for several days.
Turn the knob to .
Adjustment of the number of days (1 to 365)
Example: for a departure on 1 March
and a return on 10 March, program 9
days of absence.
Automatic operation will resume on 10 March at midnight.
Confirm and start the calendar
countdown.
To cancel the current absence |
Return to AUTO mode at the |
mode, turn the knob. |
end of the countdown |
Note: The water heater (DHW) is shutdown during the absence mode. If you want the water heater to be in automatic mode, refer to the “installation guide” or contact your installer or our customer service department
- 10 - |