Chauvet DJ Data Stream 4 Quick Start Guide

0 (0)
Chauvet DJ Data Stream 4 Quick Start Guide

Quick Reference Guide

Data Stream 4 QRG

EN

About This Guide The Data Stream 4 Quick Reference Guide (QRG) has basic product information such as mounting and operation. For more information, download the User Manual from the Chauvet website http://www.chauvetlighting.com/product-manuals-literature/.

Disclaimer The information and specifications contained in this QRG are subject to change without notice.

Safety Notes The following Safety Notes include important information about installation, use, and maintenance.

·Always connect the product to a grounded circuit.

·Make sure the power cord is not crimped or damaged.

·Always disconnect the product from the power source before cleaning it or replacing the fuse.

·Never disconnect the product from the power source by pulling or tugging on the cord.

·If mounting the product overhead, make sure there is adequate support for the product’s weight and always secure the product using a safety cable.

·Make sure there are no flammable materials close to the product when it is operating.

·The product is not intended for permanent installation.

·The product is for indoor use only. It is rated at IP20.

·Do not expose the product to rain or moisture.

·Always connect the product to a power source that is within the voltage range stated on the label or rear panel of the product.

·Make sure to replace the fuse with another of the same type and rating.

·Always install the product in a location with adequate ventilation.

·Do not operate the product at an ambient temperature higher than 104 °F (40 °C).

·Never carry the product by the power cord.

·If there is a serious operating problem, stop using the product immediately.

·Never try to repair the product. Repairs carried out by untrained people can lead to damage or malfunction.

·To eliminate wear and improve its lifespan, during periods of non-use completely disconnect from power via breaker or by unplugging it.

Contact

·

From outside the U.S., UK, Ireland, Mexico, or Benelux, contact the

 

 

distributor of record to request support or return a product.

 

· From inside the U.S., UK, Ireland, Mexico, or Benelux, use the information

 

 

in Contact Us at the end of this QRG.

 

What Is Included

·

Data Stream 4

·

Warranty card

 

·

Power Cord

·

Quick Reference Guide

2

Data Stream 4 QRG

EN

To Begin Carefully unpack the Data Stream 4 and check that all the parts are in the package, and are in good condition.

If the box, or any of the contents, appear damaged from shipping, or show signs of mishandling, save all the packaging and file a claim with the carrier immediately, do not notify Chauvet. Failure to report damage to the carrier immediately, or failure to have all the packaging available for inspection, could invalidate the claim.

For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery. For information on contacting Chauvet, see Contact Us at the end of this QRG.

Description The Data Stream 4 is a universal DMX-512 optical splitter designed to distribute/boost the incoming DMX signal into 4 separate outputs. Each of the 4 outputs is electronically isolated from the others, with the exception of the DMX Thru (throughput) or Link Out. Each output has 3- and 5-pin XLR ports. Increase operation by linking other Data Stream 4 units together.

DMX Signal

DMX In

Link Out/DMX

 

 

Ears for

 

3- and 5-pin

Throughput 3- and 5-pin

 

 

Rackmount

 

Indicator

 

 

 

Power

 

 

 

 

 

Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicator

DMX Out

 

 

 

View

 

 

3- and 5- pin

Overview

M10

Power In

Rear

Mounting

View

 

Hole

 

Fuse Holder

 

 

3

Data Stream 4 QRG

EN

AC Power Data Stream 4 has an auto-ranging power supply that works with a voltage range of 100–240 VAC, 50/60 Hz.

To eliminate wear and improve its lifespan, during periods of non-use completely disconnect from power via breaker or by unplugging it.

Fuse Replacement 1. Disconnect the product from power.

2.Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.

3.Pry the fuse holder from its housing.

4.Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type and rating.

5.Re-insert the fuse holder and reconnect power.

Disconnect the product from power before replacing the fuse.

DMX Linking

The

Data

Stream

4 works with

DMX

controllers. For

information

 

about

configuring

Data

Stream

4 for

additional

DMX

operation,

 

download

the

User

Manual

from

the

Chauvet

website:

http://www.chauvetlighting.com/product-manuals-literature/. For information about

DMX download the Chauvet DMX Primer, from the Chauvet website:

http://www.chauvetlighting.com/downloads/DMX_Primer_rev05_WO.pdf.

Mounting Before mounting the Data Stream 4, read the Safety Notes in this QRG. The Data

Stream 4 conveniently mounts in a single rack space (1U). If mounting overhead, make sure the mounting clamps (such as CLP-15 clamps from Chauvet) are capable of supporting the weight of the product. Always use a mounting point and at least one safety cable per product. For the Chauvet line of mounting clamps, go to www.chauvetlighting.com/cables-clamps-main.html.

Mounting Clamp

(such as CLP-15 from Chauvet)

Rear View

Safety Cable

(such as CH-05 from Chauvet)

Overhead Mounting Diagram

Bottom View

4

Data Stream 44 GRR

ES

Acerca de Esta

Guía

Exención de

Responsabilidad

Notas de Seguridad

La Guía de Referencia Rápida (GRR) del Data Stream 4 contiene información básica sobre el producto, tales como montage y operación. Para más información, descargue el Manual de Usuario del sitio web de Chauvet http://www.chauvetlighting.com/product-manuals-literature/.

La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.

Las siguientes notas de seguridad incluyen información importante sobre la instalación, uso y mantenimiento.

·Conecte siempre el producto a un circuito con toma de tierra.

·Asegúrese de que el cable de alimentación no está retorcido ni estropeado.

·Desconecte siempre el producto de la fuente de alimentación antes de limpiarlo o cambiar el fusible.

·Nunca desconecte el producto de la fuente de alimentación agarrando o tirando del cable.

·Si monta el producto en altura, asegúrese de que el soporte es adecuado para el peso del producto y asegure siempre el producto con un cable de seguridad.

·Asegúrese de que no hay materiales inflamables cerca del producto cuando esté en funcionamiento.

·El producto no está concebido para una instalación permanente.

·El producto es para uso en interiores solamente. Está clasificado como IP20.

·No exponga el producto a lluvia o humedad.

·Conecte siempre el producto a una fuente de alimentación que esté en el rango de tensión especificado en la etiqueta del panel posterior del producto.

·Nunca conecte el producto a un atenuador o reostato.

·Asegúrese de sustituir el fusible con otro del mismo tipo y categoría.

·Instale siempre el producto en un lugar con ventilación adecuada.

·Deje al menos 20 in (50 cm) entre el producto y superficies adyacentes.

·No haga funcionar el producto a una temperatura ambiente superior a

104 °F (40 °C).

·Nunca mueva el producto agarrándolo por el cable de alimentación o por cualquier parte móvil.

·Si hay un problema grave de funcionamiento, deje de usar el producto inmediatamente.

·Nunca intente reparar el producto. Las reparaciones llevadas a cabo por personal no cualificado pueden provocar averías o funcionamiento defectuoso.

·Para evitar un desgaste innecesario y alargar su vida útil, desconecte complemente el producto de la alimentación, mediante el interruptor o desenchufándolo, durante los periodos en los que no se use.

Contacto · Desde fuera de EE.UU, Reino Unido, Irlanda, México o Bénelux póngase en contacto con su distribuidor oficial para solicitar asistencia o devolver el producto.

·Desde dentro de EE.UU, Reino Unido, Irlanda, México o Bénelux, utilice la información de Contact Us (contáctenos) al final de esta GRR.

5

Data Stream 44 GRR

ES

Qué va Incluido ·

Data Stream 4

·

Tarjeta de garantía

·

Cable de alimentación

·

Guía de referencia rápida

Para Empezar Desembale el Data Stream 4 con cuidado y compruebe que todas las piezas están en el paquete y en buen estado.

Si la caja o alguno de los contenidos parecen dañados a causa del transporte, o muestran signos de manipulación inadecuada, guarde todo el paquete y tramite una reclamación con el transportista inmediatamente; no lo notifique a Chauvet. Si no informa al transportista del daño inmediatamente o no dispone todo el paquete para inspección podría quedar anulada la reclamación.

Para otras incidencias, como componentes o piezas que falten, daños no relacionados con el transporte o daños no evidentes, presente una reclamación a Chauvet en el plazo de 7 días desde la entrega. Para información sobre cómo contactar con Chauvet, vea la sección Contact Us (contáctenos) al final de esta GRR.

Descripción El Data Stream 4 es un splitter óptico DMX-512 universal diseñado para distribuir/amplificar la señal DMX entrante en 4 salidas independientes. Cada una de las 4 salidas está aislada electrónicamente de las demás, con excepción de la DMX Thru (envío de señal) o Link Out (enlace de salida). Cada salida tiene conectores XLR de 3 y 5 pines. Aumente el funcionamiento enlazando otras unidades Data Stream 4.

Indicador de

Entrada DMX

Enlace de salida/Envío de

Orejas Para

señal DMX

3 y 5 pines

señal DMX 3 y 5 pines

Montaje en Rack

Indicador de

Salida DMX

Vista

Alimentación

Frontal

 

3 y 5 pines

Vista General

Entrada de

 

 

 

 

Alimentación

 

Agujero de

 

Vista

Montaje a Rosca

Portafusibles

Posterior

de M10

 

 

6

Loading...
+ 14 hidden pages