Amana GCSS920804CN, GCSS920603BN, ACSS920603BN, ACSS921005CN, GCSS921005CN Technical Manual

...
0 (0)
TECHNICAL MANUTECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANUTECHNICAL MANU
ALAL
AL
ALAL
*MSS92, *CSS92
34.5" SINGLE STAGE
UP TO 92% AFUE
Refer to Service Manual RS6612012 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person.
and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
RT6612029
August 2014
is a registered trademark of Maytag Corporation or its related companies
® Copyright 2014 Goodman Company, L.P.
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
* M S S 92 060 3 B N A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Brand Minor Revision A- A mana® Brand G- Goodman® Brand A - Initial Release
Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Release K - Dedicated Upflow B - 1st Revision D - Dedicated Downfl ow
Airflow N - Natural Gas C - V ariable Speed/Co mfortNet X - Low Nox E - High Ef ficiency S - Single Speed Cabinet Width
Gas Valve Stages B - 17.5" M - Mo dul ating C - 21" V - 2 Stage D - 24.5" H - Convertible 2 Stage S - Single Stage Max im um CF M
AFUE 4 - 1600 CFM 92 - 92% AFUE 5 - 2000 CFM
B - 1st Revision
Nox
A - 14"
3 - 1200 CFM
MBTU/ h 040 - 40, 000 060 - 60, 000 080 - 80, 000 100 - 100,000 120 - 120,000
WARNING
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
WARNING
WARNING
Goodman will not be responsible
for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.
2
WARNING
WARNING
Installation and repair of this unit should be performed
ONLY by indi­viduals meeting the requirements of an "entry level tech­nician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
ACSS920402BN** GCSS920402BN** ACSS920603BN** GCSS920603BN** ACSS920804CN** GCSS920804CN** ACSS921005CN** GCSS921005CN** AMSS920402BN** GMSS920402BN** AMSS920603BN** GMSS920603BN** AMSS920803BN** GMSS920803BN** AMSS920804CN** GMSS920804CN** AMSS920805CN** GMSS920805CN** AMSS921004CN** GMSS921004CN** AMSS921005CN
**
AMSS921205DN** GMSS921205DN**
DANGER
GMSS921005CN**
CARBON MONOXIDE POISONING HAZARD
Specia l warning for inst allation of furnaces or air handling units in enclo s ed area such as g arages, utility r ooms or parking a reas. Carbon monox id e pr od uc ing devices (such as automobile, space heater, gas water heater, etc.) Should not be operated in enclosed areas such as unventilated garage s or util ity r ooms because of the danger of carbon monoxide (CO) poi s oning resulting from the exhaust emissions. If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein, there must be adequate direct outside ventilation. Carbon monoxide emissions can be (re)circulated throughout the structure if the furnace or air handler is operating in any mode. CO can cause serious illne ss includin g permanent brain damage or death.
RISQUE D'EMPOISONNEMENT AU MONOXYDE DE CARBONE
Avertissement special au sujet de l'installation d'appareils de chauffage ou de traitement d'air dans des endroits clos, tets les garages, les locaux d'en treti en et les
stationnements. Evitez de mettre en marche les appareils produisant du monoxyde de carbone (tels que les automobile, les appareils de chauffag e auton ome,etc.) dans des endroits non ventilés tels que les d'empoisonnement au monoxyde de carbone. Si vous devez faire fonctionner ces appareils dans un endroit clos, assures-vous qu'il y ait une ventilation directe provenant de l'exterie . Les émissions de monoxyde de carbone peuvent etre recircules dans les endro i ts cl os , si l'appareil de chauffage ou de traitement d'air sont en marche. Le monoxyde de carbone peut causer des maladies graves telles que des dommages permanents au cerveau et meme la mort.
DANGER
PELIGRO
RIESGO DE INTOXICACIÓN PO R MONÓXIDO DE CARBONO
Advertencia especial para la instalación de calentadores ó maneja oras de aire en áreas cerradas como estacionamientos ó cuartos de servicio. Los equipos ó aparatos que producen monóxido de carbono (tal como automóvil, calentador de gas, calentador de agua por medio de gas, etc) no deben se r operados en áreas cerradas debido al riesgo de envenenamiento por monóxido de carbono (CO) que resulta de las emisiones de gases de combustión. Si el equipo ó aparato se opera en dichas áreas, debe existir una adecuada ventilac ón directa al exter ior. Las emisiones de monóxido de carbono pueden circular a través del aparat o cu a nd o se op er a en cualquier modo. El monó x i do de carbono puede cau sar enf er medades severas com o daño cereb ra l perm a nente ó muerte.
WARNING
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations re­garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
0140M00020-D
WARNING
WARNING
Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.
Do not connect or use any device that is not design certified by Goodman for use with this unit.
WARNING
WARNING
do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.
To prevent the risk of property damage, personal injury, or death,
3
Loading...
+ 7 hidden pages