Installation and Instruction Manual For:

CFS01 Series, CFS02 Series,

CFS11 Series, and CFS12 Series Housings

Installer: Please leave this manual with owner/operator.

Owner/Operator: Please retain for operation and future maintenance instructions.

3M CFS12, CFS01, CFS02, CFS11 User Manual

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CFS Series Housings. Retain these instructions for future reference.

Intended Use:

The CFS Series Housings are intended for use in fiiltering potable water in the foodservice industry and have not been evaluated for other uses. These systems are typically installed at the point-of-entry, and must be installed as specifiied in the installation instructions.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or

 

property damage.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or

 

property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking:

• Do not allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with the ingestion of contaminants:

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of installation:

Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the filter bracket.

To reduce the risk of physical injury:

• Depressurize system as shown in manual prior to cartridge removal.

CAUTION

To reduce the risk associated with property damage due to water leakage:

Read and follow Use Instructions before installation and use of this system.

Installation and Use MUST comply with all state and local plumbing codes.

Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40°F (4.4°C);

Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C).

Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.

On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.

Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs.

Do not install in direct sunlight or outdoors.

Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.

Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.

Ensure that the location and fasteners will support the weight of the system when installed.

Ensure all tubing and fittings are secure and free of leaks.

The disposable filter cartridge MUST be replaced every 6 months or at the rated capacity or if a noticeable reduction in flow rate occurs.

IMPORTANT NOTES

Failure to follow instructions may void warranty.

Allow a minimum of 2” (5 cm) clear space under filter to facilitate cartridge change.

Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.

The filter system may be used with metallic or non-metallic piping systems. Any non-metallic fittings used for the installation must be of adequate rating for the line pressure.