These respirators are specifically designed to offer versatility, comfort and long life. They are available in multiple sizes and in half-orfull-faceconfigurations. Suitable for either negative or positive pressure uses, they can use filters and/or cartridges in a wide range of combinations to provide protection in numerous applications. All are available with complete spare parts.

3M respirators offer users an effective way of meeting OSHA requirements. Depending on your workplace application, 3M has a respirator with innovative features and technologies that workers will wear.

Features & Benefits

Available in 3 sizes (small, medium, large) to comfortably fit many faces.

Half facepieces have a four-pointstrap attachment with convenientfront-strapadjustment.

N95, P95 or P100 filters can be used in combination with chemical cartridges.

Extra large inhalation and exhalation valves for easier breathing.

The full facepiece has doubleflange face seal and six adjustable straps to help provide a secure fit, and improved fit-testresults.

The full facepiece is available in 11 different modes from air purifying to SCBA.

Fax on Demand: 1 800 646-16557000 Series Document #4018

Suggested Applications

Painting

Welding

Abatement

Wood-working

Metal-working

Automotive manufacturing

Chemical manufacturing

Pharmaceutical manufacturing

Petrochemical

Nuclear

Utilities

Primary metals

WARNING !

These respirators help reduce exposure to certain airborne contaminants. Misuse may result in sickness or death. Before use, the wearer must read and understand User Instructions provided as a part of product packaging. Time use limitations may apply. Call 3M OH&ESD Technical Service.

1 800 243-4630.

Important

Before using these respirators, you must determine the following:

1.The type of contaminant(s) for which the respirator is being selected.

2.The concentration level of contaminant(s).

3.Whether the respirator can be properly fitted on the wearer’s face. All respirator instructions, warnings and use and time limitations must

also be read and understood by the wearer before use.

Before use of these respirators, a written respiratory protection program must be implemented, meeting all the requirements of OSHA 29 CFR 1910.134, including training and fit testing.

United States

 

Canada

Technical Service 1 800 243-4630

C114

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

3MHalf and Full Facepiece Respiratorswith Bayonet Attachment 7000 Series

Facepieces

7001 Small

7800S Small

7002 Medium

7800S Medium

7003 Large

7800S Large

Cartridges & Filters

 

 

 

NEW!

 

 

 

C

2071

6001

60921

 

P95 Filter

OV

P100/OV

Respiratory

 

Filter Retainers

 

 

 

 

 

& Adapters

 

Protection

2076*

6002

60922

HF/P95 Filter

AG

P100/AG

 

 

502 Adapter

 

Solutions

 

 

 

2078**

6003

60923

 

P95 Filter

OV/AG

P100/OV/AG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

501 Retainer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2091

 

 

 

 

 

 

 

6004

 

60924

 

 

P100 Filter

 

 

 

 

 

 

 

 

 

 

 

AM/MA

 

 

P100/AM/MA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2096***

5N11

5P71

6005

60925

P100 Filter

N95 Filter

P95 Filter

Form

P100/Form

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*P95 filter with hydrogen fluoride and

2097****

nuisance level acid gas relief.

6006

60926

** P95 filter with nuisance level organic

P100 Filter

Multi Gas

P100/Multi Gas

vapor/acid gas relief.

 

 

 

***P100 filter with nuisance level acid gas relief.

****P100 filter with nuisance level organic vapor relief.

#OSHA regulations require that gas-proofgoggles be

7093

worn with half facepiece respirators when used against

6009

60929

formaldehyde.

P100 Filter

 

Merc

P100/Merc

OV

= NIOSH approval: Certain organic vapors.

AG

= NIOSH approval: Chlorine, hydrogen

 

chloride, and sulfur dioxide or chlorine

 

dioxide or hydrogen sulfide (escape only).

OV/AG = NIOSH approval: Certain organic vapors, chlorine, hydrogen chloride, and sulfur

dioxide or hydrogen sulfide (escape only) or hydrogen fluoride.

AM/MA = NIOSH approval: Ammonia and methylamine.

Form = NIOSH approval: Formaldehyde # and certain organic vapors

Multi-Gas=NIOSH approval: Certain organic vapors,

chlorine, hydrogen chloride, chlorine

Fax on Demand: 1 800 646-1655

dioxide, sulfur dioxide, hydrogen sulfide E-mail: occsafety@mmm(escape only) ammonia/methylamine,.com

formaldehyde # or hydrogen fluoride.

Web Site: www.3M m/occsafety

Merc = NIOSH approval: Mercury vapor or chlorine gas.

United States

 

Canada

Technical Service 1 800 243-4630

C115

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

C

Respiratory Protection Solutions

Half and Full Facepiece Respirators with Bayonet Attachment 7000 Series

Checklist for Building a Complete Respirator Assembly

 

1.

Select full or half facepiece and

• Do you need cartridges?

3. Select needed accessories based

 

determine size: small, medium or large.

See pages C119-C120.

on your application.

2.

Determine protection requirements.

• If you need filters and cartridges, review

See pages C121-C122.

Do you need filters, retainers or

pages C117-C120.

4. For replacement parts,

 

adapters? See pages C117-C118.

 

see pages C123-C124.

 

 

 

 

Half Facepiece Respirators with Bayonet Attachment 7000 Series 7001 (small), 7002 (medium), 7003 (large)

These facepieces can be used with 2000 Series, 5000 Series, and 6000 Series cartridges, filters, retainers and adapters. Note: These facepieces also can be used as a dual airline respirator system. For more information on dual airline systems, see page D57.

Photo#4962 (small), 4970 (medium), 4961 (large)

Ordering Information

Model

Description

Packaging

UPC Code

National Stock #

7001

Size: small

1 facepiece/box

10/case

5 00 51138 29324 1

4240-01-342-2852

 

 

 

 

 

 

7002

Size: medium

1 facepiece/box

10/case

5 00 51138 29326 5

4240-01-342-2853

 

 

 

 

 

 

7003

Size: large

1 facepiece/box

10/case

5 00 51138 29328 9

4240-01-342-2854

 

 

 

 

 

Filters, Retainers, Adapters See page C117

 

 

 

 

 

 

 

 

 

 

Cartridges

See page C119

 

 

 

 

 

 

 

 

 

 

Accessories

See page C121

 

 

 

 

 

 

 

 

 

 

Replacement Parts

See page C124

 

 

 

 

 

 

 

 

 

 

Full Facepiece Respirators with Bayonet Attachment 7000 Series 7800S(S) (small), 7800S(M) (medium), 7800S(L) (large)

These facepieces can be used with: 3M2000, 5000, 6000 and 7000 Series cartridges, filters and adapters, 3M™ Powered Air PurifyingRespirators—seepage D1; 3M Supplied AirRespirators—seepage D1; and 3M Self Contained Breathing Apparatus see page F1.

Photo#4991 (small), 4993 (medium), 4973 (large)

Ordering Information

Model

Description

Packaging

UPC Code

National Stock #

7800S(S)

Size: small

1 each/case

5 00 51138 54257 8

N/A

 

 

 

 

 

7800S(M)

Size: medium

1 each/case

5 00 51138 54258 5

N/A

 

 

 

 

 

7800S(L)

Size: large

1 each/case

5 00 51138 54259 2

N/A

 

 

 

 

Filters, Retainers, Adapters See page C117

 

 

 

 

 

 

 

 

Cartridges

See page C119

 

 

 

 

 

 

 

 

Accessories

See page C121

 

 

 

 

 

 

 

 

Replacement Parts

See page C123

 

 

 

 

 

 

 

 

Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest you, simply call 1 800 896-4223.

United States

 

Canada

Technical Service 1 800 243-4630

C116

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

3M

2000 Series Filters for 3MRespiratorswith Bayonet Attachment 7000 Series

 

 

 

2071 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P95 filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

2071

100 filters/case

5 00 51138 54356 8

4240-1-372-3403

 

 

Photo#4909

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2076HF Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P95 filter with hydrogen fluoride and nuisance level acid gas relief.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

2076HF

100 filters/case

5 00 51138 54369 8

N/A

 

 

Photo#4912

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2078 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P95 filter with nuisance level organic vapor/acid gas relief.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2078

100 filters/case

5 00 51138 54368 1

N/A

 

Photo#4910

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2091 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P100 filter for 3M™ Half-FacepieceRespirator

6000 Series assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

Photo#4911

 

 

 

 

 

 

 

 

 

 

 

 

2091

100 filters/case

5 00 51138 46201 2

4240-01-320-1954

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2096 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P100 filter with nuisance level acid gas relief.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

 

 

 

 

 

Photo#4913

 

 

2096

100 filters/case

5 00 51138 54295 0

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2097 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P100 filter with nuisance level organic vapor relief.*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

Photo#4914

 

 

2097

100 filters/case

5 00 51138 54296 7

N/A

 

 

 

 

 

 

 

 

 

 

 

 

Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest you, simply call 1 800 896-4223.

 

 

Fax on Demand: 1 800 646-1655

* Nuisance levels refer to concentrations below the OSHA PEL.

 

E-mail:occsafety@mmm.com

 

 

Web Site: www.3M.com/occsafety

 

 

 

United States

 

Canada

Technical Service 1 800 243-4630

C117

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

C

Protection Respiratory

Solutions

C

Respiratory Protection Solutions

Filters,Adapters, Retainers for 3M

Respirators with Bayonet Attachment7000 Series

 

5N11 Filter

 

 

 

 

 

 

 

 

 

 

 

 

N95 filter for use with the 501 filter retainer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

 

 

 

 

 

5N11

100 filters/case

5 00 51138 46464 1

N/A

 

 

 

Photo#5062

5P71 Filter

P95 filter for use with the 501 filter retainer.

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

5P71

100 filters/case

5 00 51138 54331 5

4240-01-452-8678

 

 

Photo#5042

 

 

 

 

 

 

 

 

 

7093 Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P100 filter.

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

Photo#4989

 

 

7093

60 filters/case

0 00 51138 46474 5

N/A

 

 

 

 

 

 

 

 

 

 

 

501 Filter Retainer

Filter retainer for use with the 5N11 or 5P71 filters.

 

 

 

Ordering

Information

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

501

100/case

0 00 51138 17668 6

4240-01-302-5290

 

Photo#5030

 

 

 

 

 

 

502 Filter Adapter

Filter adapter for use with the 2000 Series or 7093 filters.

 

 

 

Ordering

Information

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

502

100/case

0 00 51138 21511 8

4240-01-320-1956

 

Photo#5031

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest you, simply call 1 800 896-4223.

United States

 

Canada

Technical Service 1 800 243-4630

C118

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

3MCartridges 6000 Series for 3MRespiratorswith Bayonet Attachment 7000 Series

To determine end-of-servicelife for 3Mcartridges, use 3M Respirator Service Life Software. See page C122. 6001 Organic Vapor Cartridge

NIOSH approval: Certain organic vapors.

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

6001

60 cartridges/case

0 00 51138 21674 0

4240-01-342-2857

 

Photo#4971

 

 

 

 

 

 

 

 

 

 

6002 Acid Gas Cartridge

 

 

 

 

 

 

 

 

 

 

 

 

NIOSH approval: Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or

 

 

 

hydrogen sulfide (escape only).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

Photo#4972

 

 

 

 

 

 

 

6002

60 cartridges/case

0 00 51138 28880 8

4240-01-342-2858

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6003 Organic Vapor and Acid Gas Cartridge

 

 

 

 

 

 

 

 

 

 

NIOSH approval: Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or

 

 

 

hydrogen sulfide (escape only) or hydrogen fluoride.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

Photo#5259

 

 

 

 

 

 

6003

60 cartridges/case

0 00 51138 28881 5

4240-01-342-2859

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6004 Ammonia and Methylamine Cartridge

 

 

 

 

 

 

 

 

 

 

NIOSH approval: Ammonia and methylamine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

 

 

 

 

 

 

6004

60 cartridges/case

0 00 51138 28882 2

4240-01-342-2860

 

Photo#4974

 

 

 

 

 

 

 

 

 

 

 

6005 Formaldehyde and Organic Vapor Cartridge

 

 

 

 

 

 

 

 

 

 

NIOSH approval: Formaldehyde** and certain organic vapors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

 

 

 

 

 

 

 

 

 

6005

60 cartridges/case

0 00 51138 28883 9

4240-01-342-2861

 

Photo#4976

 

 

 

 

 

 

 

 

 

 

 

 

6006 Multi-Gasand Vapor Cartridge

 

 

 

 

 

 

 

 

 

 

 

 

NIOSH approval: Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide,

 

 

 

hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde** or hydrogen fluoride.

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

Photo#5260

 

 

 

 

 

 

6006

60 cartridges/case

0 00 51138 54186 1

N/A

 

 

 

 

 

 

 

 

 

 

 

 

6009 Mercury Vapor Cartridge

NIOSH approval: Mercury vapor or chlorine gas.

 

 

 

Ordering

Information

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

6009

60 cartridges/case

0 00 51138 29148 3

4240-01-394-6341

 

Photo#4977

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fax on Demand: 1 800 646-1655

** OSHA regulations require that gas-proofgoggles be worn with half facepiece respirators when used against formaldehyde. E-mail: occsafety@mmm.com

Web Site: www.3M.com/occsafety

United States

 

Canada

Technical Service 1 800 243-4630

C119

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

C

Protection Respiratory

Solutions

NEW!

C

Respiratory Protection Solutions

Cartridges 6000 Series for 3MRespiratorswith BayonetAttachment 7000 Series

To determine end-of-servicelife for 3Mcartridges, use 3M Respirator Service Life Software. See page C122.

60921 Cartridge

NIOSH approval: P100/certain organic vapors.

 

Ordering

Information

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

60921

60 cartridges/case

5 00 51138 46465 8

4240-01-342-2857

 

 

 

 

 

 

 

60922 Cartridge

NIOSH approval: P100/chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only).

 

Ordering

Information

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

60922

60 cartridges/case

5 00 51138 46466 5

4240-01-342-2858

 

 

 

 

 

 

 

60923 Cartridge

NIOSH approval: P100/certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride.

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

60923

60 cartridges/case

5 00 51138 46467 2

4240-01-342-2859

 

 

 

 

 

 

 

 

 

 

 

 

 

60924 Cartridge

 

 

 

 

 

 

NIOSH approval: P100/ammonia and methylamine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

60924

60 cartridges/case

5 00 51138 46468 9

4240-01-342-2860

 

 

 

 

 

 

 

 

 

 

 

 

60925 Cartridge

 

 

 

 

 

 

NIOSH approval: P100/formaldehyde** and certain organic vapors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering

Information

 

 

 

 

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

 

 

60925

60 cartridges/case

5 00 51138 46469 6

4240-01-342-2861

 

 

 

 

 

 

 

 

 

 

 

 

 

60926 Cartridge

NIOSH approval: P100/certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde** or hydrogen fluoride.

 

Ordering

Information

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

60926

60 cartridges/case

0 00 51138 54187 8

N/A

 

 

 

 

 

 

 

60929 Cartridge

NIOSH approval: P100/mercury vapor or chlorine gas.

 

Ordering

Information

 

 

 

 

Model

Packaging

UPC Code

National Stock #

 

60929

60 cartridges/case

5 00 51138 46471 9

4240-01-394-6341

 

 

 

 

 

 

 

** OSHA regulations require that gas-proofgoggles be worn with half facepiece respirators when used against formaldehyde.

United States

 

Canada

Technical Service 1 800 243-4630

C120

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

3M

Accessories for 3M

Respirators with Bayonet Attachment

7000 Series

 

 

 

3MFit Test Kits

 

 

 

 

 

 

 

 

 

 

 

 

FT-10Qualitative Fit Test Apparatus (sweet solution)

 

 

 

 

 

Includes FT-11Sensitivity Solution (sweet),FT-12Fit Test Solution (sweet)FT-14

 

 

 

Fit Test Hood, FT-15Collar, FT13 Nebulizer (2 pack)

 

 

 

 

 

FT-20Training and Fit Testing Case (sweet solution)

 

 

 

 

 

Includes FT-10Materials, Universal Fitting Video, Animated Guide to Respiratory

 

 

 

Protection Video, Fitting Posters

 

 

 

 

 

 

FT-30Qualitative Fit Test Apparatus (bitter solution)

 

 

 

 

 

Includes FT-31Sensitivity Solution (bitter),FT-32Fit Test Solution (bitter),FT-14

 

 

 

Fit Test Hood, FT-15Collar,FT-13Nebulizer (2 pack)

 

 

 

 

 

 

 

 

 

Photo#5531

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information

 

 

 

 

 

Model

Description

Packaging

UPC Code

National Stock #

 

FT-10

qualitative fit test apparatus: sweet solution

1/box 1box/case

0 00 51138 16358 7

4240-01-248-8146

 

 

FT-20

training and fit testing case: sweet solution

1/box 1box/case

5 00 51138 29137 7

N/A

 

 

FT-30

qualitative fit test apparatus: bitter solution

1/box 1box/case

5 00 51138 54203 5

N/A

 

 

 

 

 

 

 

 

 

 

3MQuantitative Fit Test Adapter 601

 

 

 

 

 

 

 

 

 

 

For use with 3M Respirators 6000 Series and 7000 Series with Bayonet Attachment.

 

 

 

 

 

 

 

 

Photo#5019

 

Ordering

Information

 

 

 

 

 

Model

Description

Packaging

UPC Code

National Stock #

 

601

one size

1/case

5 00 51138 29018 9

4240-01-372-3079

 

 

 

 

 

 

 

 

3MRespirator Cleaning Wipes 504

These 8”x10” towelettes are alcohol-freeand will not damage the facepiece materials. They are individually wrapped to hold moisture and are stored in a convenient dispenser box.

 

 

Ordering

Information

 

 

 

 

 

 

 

Model

Description

Packaging

UPC Code

National Stock #

 

 

 

504

Individually packaged

500/case

0 00 51138 28909 6

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fax on Demand: 1 800 646-1655

 

 

Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest

 

you, simply call 1 800 896-4223.

 

E-mail:occsafety@mmm.com

 

 

Web Site: www.3M.com/occsafety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

United States

 

 

Canada

 

 

 

 

Technical Service 1 800 243-4630

C121

Technical Service 1 800 267-4414

 

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

C

Protection Respiratory

Solutions

Accessories for Use with 3MRespiratorswith BayonetAttachment 7000 Series

3M™ Respirator Service Life Software

This software calculates respirator service life based on workplace conditions. Download the free software from our website: www.3M.com/occsafety.

C

Respiratory Protection Solutions

3M™ Personal Air Monitoring System

3M air monitors are simple and effective devices that collect certain airborne contaminants using the scientific principle of diffusion. They meet or exceed ±25% accuracy at a confidence level for many workplace contaminants. for Air Monitoring Systems, see page B1.

Photo#5240, 5241

Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest you, simply call 1 800 896-4223.

United States

 

Canada

Technical Service 1 800 243-4630

C122

Technical Service 1 800 267-4414

Sales Assistance 1 800 896-4223

Sales Assistance 1 800 265-1840ext. 6137

2000 Resource Guide

3MReplacement Parts Respiratorswith Bayonet Attachment 7000 Series

 

 

 

9

 

30

 

 

 

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

5

 

1

12

 

14

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

11

2

 

 

 

 

 

 

 

 

 

 

 

 

 

34

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

17-18

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

21

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

31

3

4

24-27

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Photo#7950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information—ReplacementParts: Full Facepiece Respirator 7800S

 

 

 

 

 

ID #

Model

 

Description

Packaging

UPC Code

National Stock #

 

 

 

1

701

Cartridge/Filter Adapter

2 each/bag

10 bag/case

5 00 51138 29113 1

4240-01-389-7449

 

 

 

 

2

6895

Inhalation Gasket

20 each/bag

4 bag/case

5 00 51138 54298 1

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

7282

 

Inhalation Valve

50 each/bag

4 bag/case

5 00 51138 08742 9

4240-01-248-2607

 

 

 

4

7283

 

Exhalation Valve

10 each/bag

5 bag/case

5 00 51138 08743 7

4240-01-248-2608

 

 

 

 

5

7881S

Nose Cup Assembly, Silicone

1 each/bag

5 bag/case

5 00 51138 21341 6

N/A

 

 

 

 

6

7882

Nose Cup Valve Assembly

2 each/b0x 10 box/case

5 00 21200 60339 1

N/A

 

 

 

 

7

7883

Neck Strap Assembly

1each/bag 10 bag/case

0 00 21200 60332 7

N/A

 

 

 

 

8

7884

 

Lens

 

1 each/box 5 box/case

5 00 51138 29114 8

4240-01-2478929

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

7885

 

Lens Frame Kit

1 each/box

5 box/case

5 00 21200 60334 6

4240-01-380-4962

 

 

 

 

10

7886

Removable DIN Connector

1 each/box 5 box/case

5 00 51138 21420 8

4240-01-320-1947

 

 

 

 

11

7887

Inhalation Valve Gasket 2 each/pack

10 pack/case

0 00 21200 60328 5

N/A

 

 

 

 

12

7890

 

Full Face Plug

4 each/box

5 box/case

5 00 21200 60331 5

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

7891

 

Cartridge Holder

2each/bag 10 bag/case

5 00 21200 60327 8

4240-01-302-5291

 

 

 

14

7893S

Head Strap Assembly, Silicone 1 each/box

2 box/case

5 00 51138 21340 9

N/A

 

 

 

 

15

7894

Eyeglass Frame and Mount

1 each/box 1 box/case

0 00 21200 60379 2

4240-01-3010728

 

 

 

 

16

7895

Speaking Diaphragm Kit

1 each/kit 2 each/case

5 00 51138 17494 6

N/A

 

 

 

 

17

7899-25

Lens Cover (25 pack)

25 each/box

4 box/case

5 00 21200 60417 6

4240-01-248-6434

 

 

 

 

18

7899-100

Lens Cover (100 pack)

100 each/box 1 box/case

5 00 21200 60418 3

4240-01-248-6435

 

 

 

 

19

7914

 

Band Clamp

5 each/box 1 box/case

5 00 51138 21426 0

N/A

 

 

 

 

20

7915-5

 

Tyvek® Shroud

5 each/bag 1 bag/case

5 00 51138 21555 7

4240-01-320-1957

 

 

 

 

21

7916-5

Breathing Room Assembly

5 each/bag 1 bag/case

5 00 51138 21563 2

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Not shown in photo

 

 

 

Continued next page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fax on Demand: 1 800 646-1655

 

 

Please contact your local 3M distributor to place an order. To determine the locationE-mail:ofoccsafety@mmmthe3M distributor.comnearest

 

 

you, simply call 1 800 896-4223.

 

 

 

Web Site: www.3M.com/occsafety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

United States

 

 

 

 

 

Canada

 

 

 

 

Technical Service 1 800 243-4630

 

C123

Technical Service 1 800 267-4414

 

 

Sales Assistance 1 800 896-4223

 

Sales Assistance 1 800 265-1840ext. 6137

 

2000 Resource Guide

C

Protection Respiratory

Solutions